Low Emission AC/DC-Converter 19"/3U 100W Single Output CAA 5.20 Ordering Information Type Output ( ) Power Boost Input Voltage * CAA 5.20 O1 = 5V ; 20A 115/230 Vac * automatic mains shift Dimensions 12HP/3U 175-000-02 in mm + Sense Lead + Output Load Share - Sense Lead - Output PA I/O External ON/OFF Live L1 Neutral N Earth PE 07/2014 Article No. *1 *1 Front panel: front side anodized, backside chromatized Connector Pin Assignment H15 1 Installation Width Free pins may not be connected external! Pin 4 6, 8 10 12 14, 16 18 20 28 30 32 leading Doc.: 96350679.04 - also effective: description no.: 95930018 --- KNIEL does not accept any liability for typographical or other errors. All specifications are subject to change without prior notice. --- Low Emission AC/DC-Converter 19"/3U 100W Single Output CAA 5.20 Technical Data Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit`s output. Output O1 Output Voltage Adjustment Range (±) Output Current Nominal Current Limiting Characteristic Curve Type of Regulation Efficiency Voltage Deviation for Load Change 0... 100% (static) Mains Voltage Change Vin min-Vin max Residual Ripple (100Hz) Operating Frequency Ripple (50-190kHz) Superimposed Switching Spikes Dynamic Voltage Deviation for ∆Io = 65...100% Inom Regulation Time for ∆Io = 65...100% Inom Starting Delay Overvoltage Protection Output Factory Setting (tol.+0.5V) Residual Voltage after Tripping Sense Lead Operation (load line compensation) Overload Protection Temperature Coefficient [Vdc] [V] [A] [A] [%] [mV] [mV] [mVpp] [mVpp] [mVpp] 5 0.5 20 21 approx. V-I resonant conv. ≥ 77 ≤ 10 ≤ 5 <3 <4 <6 [mV] ≤ 150 [µs] [ms] ≤ 250 ≤ 800 [V] [V] [V] [ppm/K] 6.5 0 max. 0.25 per load line continuous short-circuit-proof 200 Input Voltage Nominal [Vac] 100-120 205-240 Operating Range (automatic mains shift) [Vac] +6%/-10% ≈ 90-127 +6%/-10% Frequency [Hz] 50-400 ±10% ≈ 45-440 50-400 ±10% in the Event of Mains Failure at Nominal Load: Buffer Time tBuff [ms] ≥ 40 Max. Input Current (nominal range) [A] 2.5 1.5 Starting Inrush Current ∫ i 2 dt ; I p [A2 s] ; [A] ≤ 1.7 ; ≤ 35 Unit Cold 2 ∫ i dt ; I p [A2 s] ; [A] ≤ 4.0 ; ≤ 70 Worst Case Unit Fuse (primary, internal) [A] T 3.15 Operating Temperature Range (measured 5mm from the side wall) [ºC] - 25… + 50 Max. allowed Case-/Radiator-Temperature [ºC] + 70 Storage Temperature Range [ºC] - 40… + 85 Weight approx. [kg] 0.9 For definitions, informations about electrical safety, EMC and mechanical stressability see description. Doc.: 96350679.04 - also effective: description no.: 95930018 ≈ 185-255 ≈ 45-440 07/2014 2
© Copyright 2024 ExpyDoc