Testing Device for 0-10 V GLT / BMS Controls Ord.no. 533996) Important User Instructions: ! Prerequisite for warranty claims is the professional use of the device in accordance with instructions of the manufacturer. Use device only if very familiar with operating mode of device to be tested (see product description for GLT control unit). We explicitly deny any and all liability for damages due to improper use of this testing device. Establish and remove any and all plug and socket connections only with power turned off. Ensure that device is not exposed to humidity or high temperatures. Note: There is an inherent danger (of crushing or clamping) from electromotively operated windows controlled by this testing device ! Mode of operation The testing device serves to test and adjust 24 V DC ventilation control units with a variable controlling or measuring-signal from 0 - 10 V DC (e.g. for operating timer GLT-LZM 2 or for ventilation control unit module with GLT control). Scope of delivery of testing device: 4 connecting cables with banana jacks ( 2 x red (+), 2 x black (-)). Connection, Displays and Control Elements Dispense set output voltage? 0 = no / = yes setting output voltage display output voltage (+) red (+) red 0 - 10 V DC 24 V DC (0 - 100 % stroke) (-) black (-) black Power supply e.g. from EMB SHEVS or ventilation control unit operation on / off display Operation Technical Data Ensure that unit is turned off when making any connections (see above). Power supply 24 - 32 V DC Current consumption: approx. 80 mA Operating switch set to ON (green display lights up). With the GLT / BMS voltage switched to output (switch position ), the setting control follows. When switch is set to “0” position there is no output (Output voltage = 0 V). Output voltage 0 - 10 V DC (adjustable) Setting accuracy: 1 % of full scale 10 V Output load max. 2 mA Display: 3,5 decimals (resolution 10 mV) If the output voltage is set to a specific value a change of the switch position from “0” to makes it possible to move the drive from the closing position to the desired opening position (e.g. 5 V = 50 % stroke). By switching to “0” ( = 0 V), the drive moves back to the closing position without having to change the set output voltage. Connections 4 x banana jacks Operating temperature range: +20 - 30 °C 115-10-0-1-8 aumüller aumatic gmbh Steinerne Furt 58a • 86167 Augsburg Postfach 52 12 61 • 86095 Augsburg Tel.: +49 (0)821 27 09 30 • Fax: +49 (0)821 70 98 42 www.aumueller-aumatic.de [email protected] 115-10-0-1-1.0 SP 12.07
© Copyright 2024 ExpyDoc