Voltage Transducer LV 200-AW/2/3200

Voltage Transducer LV 200-AW/2/3200
VPN =
3200 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
VPN
VP
RM
Primary nominal r.m.s. voltage
Primary voltage, measuring range
Measuring resistance
with ± 15 V
with ± 24 V
ISN
KN
VC
IC
Vd
@ ± 3200 Vmax
@ ± 4800 Vmax
@ ± 3200 Vmax
@ ± 4800 Vmax
3200
0 .. ± 4800
R M min
R M max
V
V
0
0
60
60
Ω
Ω
Ω
Ω
120
60
220
110
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
80
mA
3200 V / 80 mA
± 15 .. 24
V
30 (@ ± 24 V) + IS mA
12 1)
kV
1 2)
kV
R.m.s. voltage for partial discharges extinction @ 50 pC 4.8
kV
Ve
Accuracy - Dynamic performance data
XG
ε
Overall Accuracy @ VPN , TA = 25°C
Linearity
L
± 1.0
< 0.1
Typ
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
tr
Response time @ 90 % of VP max
- 25°C .. + 70°C
± 0.3
%
%
Max
± 0.3
± 0.6
200
mA
mA
µs
Features
•Closed loop (compensated) voltage
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0
•Accessible electronic circuit
•Shield between primary and
secondary circuit
•Primary resistor R 1 incorporated into
the housing.
Advantages
•Good accuracy
•Very good linearity
•Low thermal drift
•High immunity to external
interference
•Current overload capability.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Uninterruptible Power Supplies
General data
(UPS)
TA
TS
N
P
R1
RS
m
Notes :
Ambient operating temperature
Ambient storage temperature
Turns ratio
Total primary power loss
Primary resistance @ TA = 25°C
Secondary coil resistance @ TA = 70°C
Mass
Standards 3)
1)
2)
3)
- 25 .. + 70
- 40 .. + 85
80000 : 2500
8
1280
40
2
EN 50178
°C
°C
W
kΩ
Ω
kg
•Power supplies for welding
applications
•Railway overhead line voltage
measurement.
Between primary and secondary + shield
Between secondary and shield
A list of corresponding tests is available
980710/2
LEM Components
w w w .lem.com
Dimensions LV 200-AW/2/3200
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal
Terminal
Terminal
Terminal
+
M
E
-
:
:
:
:
supply voltage + 15 .. 24 V
measure
shield
supply voltage - 15 .. 24 V
Connection
or
Top view
Mechanical characteristics
•General tolerance
•Fastening
•Connection of primary
•Connection of secondary
•Fastening torque
Remarks
± 0.5 mm
4 holes ∅ 6.5 mm
M5 threaded studs
M5 threaded studs
2.2 Nm or 1.62 Lb. -Ft.
•IS is positive when VP is applied on terminal +HT.
•The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.