Voltage Transducer LV 200-AW/2/3200 VPN = 3200 V For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Electrical data VPN VP RM Primary nominal r.m.s. voltage Primary voltage, measuring range Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd @ ± 3200 Vmax @ ± 4800 Vmax @ ± 3200 Vmax @ ± 4800 Vmax 3200 0 .. ± 4800 R M min R M max V V 0 0 60 60 Ω Ω Ω Ω 120 60 220 110 Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 80 mA 3200 V / 80 mA ± 15 .. 24 V 30 (@ ± 24 V) + IS mA 12 1) kV 1 2) kV R.m.s. voltage for partial discharges extinction @ 50 pC 4.8 kV Ve Accuracy - Dynamic performance data XG ε Overall Accuracy @ VPN , TA = 25°C Linearity L ± 1.0 < 0.1 Typ IO IOT Offset current @ IP = 0, TA = 25°C Thermal drift of IO tr Response time @ 90 % of VP max - 25°C .. + 70°C ± 0.3 % % Max ± 0.3 ± 0.6 200 mA mA µs Features •Closed loop (compensated) voltage transducer using the Hall effect •Insulated plastic case recognized according to UL 94-V0 •Accessible electronic circuit •Shield between primary and secondary circuit •Primary resistor R 1 incorporated into the housing. Advantages •Good accuracy •Very good linearity •Low thermal drift •High immunity to external interference •Current overload capability. Applications •AC variable speed drives and servo motor drives •Static converters for DC motor drives •Uninterruptible Power Supplies General data (UPS) TA TS N P R1 RS m Notes : Ambient operating temperature Ambient storage temperature Turns ratio Total primary power loss Primary resistance @ TA = 25°C Secondary coil resistance @ TA = 70°C Mass Standards 3) 1) 2) 3) - 25 .. + 70 - 40 .. + 85 80000 : 2500 8 1280 40 2 EN 50178 °C °C W kΩ Ω kg •Power supplies for welding applications •Railway overhead line voltage measurement. Between primary and secondary + shield Between secondary and shield A list of corresponding tests is available 980710/2 LEM Components w w w .lem.com Dimensions LV 200-AW/2/3200 (in mm. 1 mm = 0.0394 inch) Front view Left view Secondary terminals Terminal Terminal Terminal Terminal + M E - : : : : supply voltage + 15 .. 24 V measure shield supply voltage - 15 .. 24 V Connection or Top view Mechanical characteristics •General tolerance •Fastening •Connection of primary •Connection of secondary •Fastening torque Remarks ± 0.5 mm 4 holes ∅ 6.5 mm M5 threaded studs M5 threaded studs 2.2 Nm or 1.62 Lb. -Ft. •IS is positive when VP is applied on terminal +HT. •The primary circuit of the transducer must be linked to the connections where the voltage has to be measured. •This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
© Copyright 2024 ExpyDoc