Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Contents Unpack your device ..................................................................................................................................................... 3 Prerequisites ................................................................................................................................................................... 3 Unpacking your device ............................................................................................................................................... 3 Rack-mount your device ................................................................................................................................................ 4 Site preparation............................................................................................................................................................. 4 Prerequisites ................................................................................................................................................................... 5 Rack-mounting rail kit................................................................................................................................................. 5 Install the EBOD enclosure on the rails ................................................................................................................. 5 Mounting the EBOD enclosure in the rack .......................................................................................................... 7 Mounting the primary enclosure in the rack ...................................................................................................... 8 Cable your device ............................................................................................................................................................. 9 Prerequisites ................................................................................................................................................................... 9 SAS cabling ..................................................................................................................................................................... 9 Power cabling ............................................................................................................................................................... 11 Network cabling...........................................................................................................................................................13 Serial port cabling .......................................................................................................................................................15 Unpack your device This section provides clear, detailed instructions on how to unpack your Microsoft Azure StorSimple 8600 storage device. This device is shipped in two separate boxes, one for the primary enclosure and other for the EBOD enclosure. Prerequisites To unpack your device, follow these guidelines. WARNING! %HIRUH\RXEHJLQHQVXUHWKDW\RXKDYHWZRSHRSOHDYDLODEOHWRKDQGOHWKHZHLJKWLQFDVH\RX DUHKDQGOLQJLWPDQXDOO\$IXOO\FRQÀJXUHGHQFORVXUHFDQZHLJKXSWRNJOEV 6HWWKHWZRER[HVRQDÁDWOHYHOVXUIDFH Unpacking your device Perform the following steps to unpack your device. 1. Inspect the boxes and the packaging foam for crushes, cuts, water damage, or any other obvious damage. If the box or packaging is severely damaged, do not open the box. Please contact technical support to help you assess whether the device is in good working order. 2SHQWKHWZRER[HVDQGXQSDFNWKHSULPDU\DQG(%2'HQFORVXUHV7KHIROORZLQJÀJXUHVKRZV the unpacked view of your storage device. 6 5 4 3 AC CE SS OR IES AN D CA BL ES 2 1 Figure 1 Unpacked view of your storage device 3 Label 1 3 4 5 6 Description Packing box 6$6&DEOHVLQDFFHVVRULHVDQGFDEOHVWUD\ Bottom foam Device Top foam Accessory box 3. After unpacking the two boxes, ensure you have: D SULPDU\HQFORVXUHWKHSULPDU\HQFORVXUHDQG(%2'HQFORVXUHDUHLQWZRVHSDUDWHER[HV b. 1 EBOD enclosure. F SRZHUFRUGVLQHDFKER[ G 6$6FDEOHVWRFRQQHFWWKHSULPDU\HQFORVXUHWR(%2'HQFORVXUH e. 1 crossover Ethernet cable. I VHULDOFRQVROHFDEOHV g. 1 serial-USB converter for serial access. K VLQJOH46)3WR6)3DGDSWHUV L UDFNPRXQWNLWVVLGHUDLOVZLWKPRXQWLQJKDUGZDUHHDFKIRUWKHSULPDU\HQFORVXUH DQG(%2'HQFORVXUHLQHDFKER[ j. 1 tamper-proof T10 screw driver k. Getting started documentation. If you did not receive any of the items listed above, contact technical support. The next step is to rack-mount your device. See the Rack-mount your device for details. Rack-mount your device This section includes the steps required to install your Microsoft Azure StorSimple 8600 storage device in a standard 19-inch rack with front and rear posts. This device comes with two enclosures: a primary enclosure and an EBOD enclosure. Both of these need to be rack mounted. The installation consists of multiple steps each of which is discussed in the following procedures. Site preparation The enclosures must be installed in a standard 19-inch rack that has both front and rear posts. To prepare for rack installation, ensure that: 7KHSULPDU\DQG(%2'HQFORVXUHVDUHUHVWLQJVDIHO\RQDÁDWVWDEOHDQGOHYHOZRUNVXUIDFH RUVLPLODU 7KHVLWHZKHUH\RXLQWHQGWRVHWXSKDVVWDQGDUG$&SRZHUIURPDQLQGHSHQGHQWVRXUFHRUD UDFN3RZHU'LVWULEXWLRQ8QLW3'8ZLWKDQXQLQWHUUXSWLEOHSRZHUVXSSO\836 2QH8;8VORWLVDYDLODEOHLQWKHUDFNZKHUH\RXLQWHQGWRPRXQWWKHHQFORVXUHV 4 WARNING! Ensure you have two people available to handle the weight in case you are handling it manually. $IXOO\FRQÀJXUHGHQFORVXUHFDQZHLJKXSWRNJ Prerequisites The enclosures are designed for installation into a standard 19-inch rack cabinet with: 0LQLPXPGHSWKRILQFKHVIURPUDFNSRVWWRSRVW 0D[LPXPZHLJKWRINJIRUWKHGHYLFH 0D[LPXPEDFNSUHVVXUHRI3DVFDOPPZDWHUJDXJH Rack-mounting rail kit A set of mounting rails will be provided to use with the 19-inch rack cabinet. The rails have been tested to handle the maximum enclosure weight. These rails will also allow installation of multiple enclosures ZLWKRXWORVVRIVSDFHZLWKLQWKHUDFN6WDUWZLWKWKHLQVWDOODWLRQRIWKH(%2'HQFORVXUHÀUVW Install the EBOD enclosure on the rails )ROORZWKHVHVWHSVWRVDIHO\LQVWDOOWKH(%2'HQFORVXUHRQWKHUDLOV :LWKWKHHQFORVXUHRQWKHZRUNVXUIDFHUHPRYHWKHOHIWDQGULJKWIURQWÁDQJHFDSVE\SXOOLQJ WKHFDSVIUHH7KHÁDQJHFDSVVLPSO\VQDSRQWRWKHÁDQJHV 7KHVHUDLOVDUHLQVWDOOHGDWWKHIDFWRU\,IWKHVHDUHQRWWKHQLQVWDOOWKHOHIWUDLODQGULJKWUDLO slides to the sides of the enclosure chassis. They attach using six metric screws on each side. To KHOSZLWKRULHQWDWLRQWKHUDLOVOLGHVDUHPDUNHG´/+)URQWµDQG´5+²)URQWµDQGWKHHQGWKDW LVDIÀ[HGWRZDUGVWKHUHDURIWKHHQFORVXUHKDVDWDSHUHGHQG 1 2 Figure 2 Attaching rail slides to the sides of the enclosure 5 Label 1 Description 0;EXWWRQKHDGVFUHZV Chassis slides 3. Attach the left-rail and right-rail assemblies to the rack cabinet vertical members. The brackets DUHPDUNHG´/+µ´5+µDQG´7KLVVLGHXSµWRJXLGHWKHXVHUWKURXJKFRUUHFWRULHQWDWLRQ D /RFDWHWKHUDLOSLQVDWWKHIURQWDQGUHDURIWKHUDLODVVHPEO\([WHQGWKHUDLOWRÀWEHWZHHQ the rack posts and insert the pins into the front and rear-rack post vertical member holes. Be sure the rail assembly is level. b. Secure the rail assembly to the rack vertical members using two of the metric screws provided. Use one screw on the front and one on the rear. c. Repeat these steps for the other rail assembly. 4 2 5 1 3 Figure 3 Attaching rail assemblies to the rack Label 1 3 4 5 6 Description Clamping screw Square hole front rack post Left front-rail location pins Clamping screw Right front-rail location pins Mounting the EBOD enclosure in the rack Perform the following steps to mount the EBOD enclosure in the rack using the rack rails that were just installed. 1. Using an assistant, lift the enclosure and align it with the rack rails. &DUHIXOO\LQVHUWWKHHQFORVXUHLQWRWKHUDLOVDQGSXVKLWFRPSOHWHO\LQWRWKHUDFNFDELQHW Figure 4 Mounting the enclosure in the rack 3. Secure the enclosure into the rack by installing one provided Phillips-head screw through each ÁDQJHOHIWDQGULJKW ,QVWDOOWKHÁDQJHFDSVE\SUHVVLQJWKHPLQWRSRVLWLRQDQGVQDSSLQJWKHPLQWRSODFH 7 1 )LJXUH,QVWDOOLQJWKHÁDQJHFDSV Label 1 Description Enclosure fastening screw Mounting the primary enclosure in the rack $IWHU\RXKDYHÀQLVKHGPRXQWLQJWKH(%2'HQFORVXUH\RXZLOOQHHGWRPRXQWWKHSULPDU\ enclosure following the same steps. NOTICE It is possible to have a few empty slots in the rack between the primary enclosure and the EBOD HQFORVXUH8VHWKHSURYLGHGP6$6FDEOHWRFRQQHFWWKHSULPDU\HQFORVXUHWRWKH(%2'HQFORVXUH NOTICE There are no constraints in terms of the relative placement of the head unit with respect to the EBOD. As such, the primary enclosure can be placed in the top slot and the EBOD enclosure below—or vice versa. The next step is to cable your device for power, network, and serial access. See Cable your device for detailed steps. 8 Cable your device This section includes instructions to cable your device for power, network, and serial connection. Prerequisites Before you begin the cabling of your device, you will need: <RXUSULPDU\HQFORVXUHDQGWKH(%2'HQFORVXUHFRPSOHWHO\XQSDFNHG SRZHUFDEOHVHDFKIRUWKHSULPDU\DQGWKH(%2'HQFORVXUHWKDWFDPHZLWK\RXUGHYLFH 6$6FDEOHVVXSSOLHGZLWKWKHGHYLFHWRFRQQHFWWKH(%2'HQFORVXUHWRWKHSULPDU\HQFORVXUH $FFHVVWR3RZHU'LVWULEXWLRQ8QLWV3'8VUHFRPPHQGHG 1HWZRUNFDEOHV 3URYLGHGVHULDOFDEOHV 6HULDO86%FRQYHUWHUZLWKWKHDSSURSULDWHGULYHULQVWDOOHGRQ\RXU3&LIQHHGHG 3URYLGHGVLQJOH46)3WR6)3DGDSWHUV 6)3FDEOHV SAS cabling <RXUGHYLFHKDVDSULPDU\DQGDQ(%2'HQFORVXUH7KHVHHQFORVXUHVQHHGWREHFRQQHFWHG together using the SAS cables. Perform the following steps to connect the primary enclosure to the EBOD enclosure. ,GHQWLI\WKHSULPDU\DQGWKH(%2'HQFORVXUH7KHWZRHQFORVXUHVFDQEHLGHQWLÀHGE\ORRNLQJ DWWKHUHVSHFWLYHEDFNSODQHV6HHWKHIROORZLQJÀJXUHIRUJXLGDQFH 1 2 1 II I 4 3 ID Host Fabric Host Fabric 2 3 3 1 ID 4 2 II 1 4 I A B 1 2 3 4 C 1 2 3 4 2 A 1 2 3 4 B 1 2 3 4 C 1 2 3 4 Figure 6 Back plane view of the primary and EBOD enclosures Label 1 Description Primary enclosure EBOD enclosure 9 /RFDWHWKHVHULDOQXPEHUVRQERWKWKHSULPDU\DQGWKH(%2'HQFORVXUH7KHVHULDOQXPEHU VWLFNHULVDIÀ[HGRQWKHEDFNHDURIHDFKHQFORVXUH7KHVHULDOQXPEHUVPXVWEHidentical on both enclosures. Contact technical support immediately if the serial numbers do not match. 6HHWKHIROORZLQJÀJXUHWRKHOS\RXORFDWHWKHVHULDOQXPEHUV FC: XX-XXXX-X-XXXXX-XXX HLA SN: ZZVPPPPPPPSSSSS Rev. X HLA P/N: PPPPPPP-XX 1 ID 3 2 1 4 II Hos I t Fa bric bric t Fa I Hos II 1 2 3 4 ID Figure 7 Rear view of the enclosure showing the location of the serial number sticker Label 1 Description Ear of the enclosure 3. The EBOD enclosure now needs to be connected to the primary enclosure using the provided SAS cables. Perform the following steps. D ,GHQWLI\WKHIRXU6HULDO$WWDFKHG6&6,6$6SRUWVRQSULPDU\HQFORVXUHDQG(%2' enclosure. The SAS ports are labeled as EBOD on primary enclosure and CTRL on the (%2'HQFORVXUHDVVKRZQLQ)LJXUH b. Use provided SAS cables to connect EBOD ports to CTRL ports. c. The EBOD port on Controller 0 should be connected to the CTRL port on EBOD controller 0. The EBOD port on Controller 1 should be connected to the CTRL port on EBOD FRQWUROOHU6HH)LJXUHIRUJXLGDQFH 10 4 3 2 1 EBOD 4 3 2 1 II I ID 5 1 EBOD A Host Fabric 2 Host Fabric EBOD 2 3 ID 4 2 1 1 II A 4 3 I 7 6 B 1 2 3 4 C CTRL L CTRL A 1 2 3 4 B 1 B 1 2 3 3 4 4 8 2 3 4 C 1 2 3 4 A 1 2 3 4 CTRL Figure 8 SAS cabling for your device Label A B 1 3 4 5, 6 7, 8 Description Primary enclosure EBOD enclosure Controller 0 Controller 1 EBOD Controller 0 EBOD Controller 1 SAS ports on primary enclosure ODEHOHG(%2' 6$6SRUWVRQ(%2'HQFORVXUHODEHOHG&75/ Power cabling <RXUGHYLFHKDVDSULPDU\HQFORVXUHDQGDQ(%2'HQFORVXUH%RWKHQFORVXUHVLQFOXGHUHGXQGDQW 3RZHUDQG&RROLQJ0RGXOHV3&0V,QHDFKHQFORVXUHHDFK3&0PXVWEHLQVWDOOHGDQGFRQQHFWHG to different power sources to ensure high availability. Perform the following steps to cable your device for power. (QVXUHWKDWWKHSRZHUVZLWFKHVRQDOOWKH3&0VDUHLQWKH2))SRVLWLRQ )RUWKHSULPDU\HQFORVXUHFRQQHFWWKHSRZHUFRUGVWRERWK3&0V7KHSRZHUFRUGVDUH 11 LGHQWLÀHGLQUHGLQWKHIROORZLQJGLDJUDP 3. Ensure that the two PCMs of the primary enclosure use separate power sources. $WWDFKWKHSRZHUFRUGVWRWKHUDFNSRZHUGLVWULEXWLRQXQLWVDVVKRZQLQWKHIROORZLQJÀJXUH 5HSHDWVWHSVIRUWKH(%2'HQFORVXUH 7XUQRQWKH(%2'HQFORVXUHE\ÁLSSLQJHDFK3&0·VSRZHUVZLWFKWRWKH21SRVLWLRQ 9HULI\WKDWWKH(%2'HQFORVXUHLVWXUQHGRQE\FKHFNLQJWKDWWKH(%2'FRQWUROOHU/('VJUHHQ /('VRQWKHEDFNRIWKHFKDVVLVKDYHWXUQHG21 1RZWXUQRQWKHSULPDU\HQFORVXUHE\ÁLSSLQJHDFK3&0VZLWFKWRWKH21SRVLWLRQ 9. Verify that the system is up by ensuring the device controller LEDs have turned ON. 10. Verify that the connection between EBOD controller and device controller is active by ensuring WKH6$6/('V/('VQH[WWRWKH6$6SRUWRQWKH(%2'FRQWUROOHUDUHJUHHQ NOTICE To ensure high availability of your system, you are advised to strictly adhere to the power cabling scheme shown in the following diagram. Figure 9 Power cabling for your device Label 1 3 4 5 6 7 8 9 Description Primary enclosure PCM 0 PCM 1 Controller 0 Controller 1 EBOD controller 0 EBOD controller 1 EBOD enclosure PDUs Network cabling <RXUGHYLFHLVLQDQDFWLYHVWDQGE\FRQÀJXUDWLRQDWDQ\JLYHQWLPHRQHFRQWUROOHUPRGXOHLV active and processing all disk and network operations while the other controller module is standby. In the event of a controller failure, the standby controller immediately activates and continues all the disk and networking operations. To support this redundant controller failover, you need to cable your device network as shown in the following steps. <RXUGHYLFHKDVVL[QHWZRUNLQWHUIDFHVRQHDFKFRQWUROOHUIRXU*ESVDQGWZR*ESV(WKHUQHW ports. Identify the various data ports in the backplane of your device. Figure 10 Back plane of your device showing the data ports Label 0, 1, 4, 5 6 Description 1 Gbps network interfaces 10 Gbps network interfaces Serial ports 13 )RUKLJKDYDLODELOLW\WKHGHYLFHUHTXLUHVDPLQLPXPRIWZRFRQQHFWLRQVIRUHDFKFRQWUROOHU D 7KH'$7$SRUWLVDXWRPDWLFDOO\HQDEOHGDQGFRQÀJXUHGYLDWKHVHULDOFRQVROHRIWKH GHYLFH$SDUWIURP'$7$DQRWKHUGDWDSRUWDOVRQHHGVWREHFRQÀJXUHGWKURXJKWKH Management Portal. E ,GHQWLI\LGHQWLFDOQHWZRUNLQWHUIDFHVRQHDFKFRQWUROOHU)RULQVWDQFHLI\RXFKRRVH to connect DATA 0 and DATA 3 for one of the controllers, you need to connect the corresponding DATA 0 and DATA 3 on the other controller. )RU+$HQVXUHWKDW\RXFRQQHFW a. Identical interfaces on each controller to the relevant network to ensure availability through a controller failure. b. Interfaces from each controller to at least two different switches to ensure availability through a switch failure. F '$7$SRUWWRWKHSULPDU\/$1QHWZRUNZLWK,QWHUQHWDFFHVV7KHRWKHUGDWDSRUWVFDQEH FRQQHFWHGWR6$1L6&6,/$19/$1VHJPHQWRIWKHQHWZRUNGHSHQGLQJRQWKHLQWHQGHGUROH $WDPLQLPXPFRQÀJXUHRQHQHWZRUNLQWHUIDFHIRUFORXGDFFHVVDQGRQHIRUL6&6,)RU+$DQG SHUIRUPDQFHFRQÀJXUHWZRSDLUVRIQHWZRUNLQWHUIDFHVRQHDFKFRQWUROOHU6HHWKHIROORZLQJ GLDJUDPIRUQHWZRUNFDEOLQJ7KHPLQLPXPQHWZRUNFRQÀJXUDWLRQLVVKRZQE\VROLGEOXHOLQHV )RU+$DQGSHUIRUPDQFHDGGLWLRQDOFRQÀJXUDWLRQUHTXLUHGLVVKRZQE\GRWWHGOLQHV Figure 11 Network cabling for your device 14 Label A B C D E ) G H, I 0-5 6 7 Description LAN with Internet access Controller 0 PCM 0 Controller 1 PCM 1 EBOD controller 0 EBOD controller 1 +RVWVIRUH[DPSOHÀOHVHUYHUV Network interfaces Primary enclosure EBOD enclosure Serial port cabling Perform the following steps to cable your serial port. <RXUGHYLFHKDVDVHULDOSRUWRQHDFKFRQWUROOHULGHQWLÀHGE\DZUHQFKLFRQ/RFDWHWKHVHULDO SRUWVLQWKHEDFNSODQHRI\RXUGHYLFHXVLQJ)LJXUH ,GHQWLI\WKHDFWLYHFRQWUROOHULQ\RXUGHYLFHEDFNSODQH$EOLQNLQJEOXH/('LQGLFDWHVWKH controller is active. 8VHWKHSURYLGHGVHULDOFDEOHLIQHHGHGWKH86%VHULDOFRQYHUWHUIRU\RXUODSWRSDQGFRQQHFW \RXUFRQVROHRUFRPSXWHUZLWKWHUPLQDOHPXODWLRQWRWKHGHYLFHWRWKHVHULDOSRUWRIWKH active controller. 4. Install the serial-USB drivers shipped with this device on your computer. 5. Set up the serial connection as follows: 115,200 baud, 8 data bits, 1 stop bit, noSDULW\ÁRZ control set to None. 6. Verify the connection is working by pressing Enter in the console. A serial console menu should be presented. NOTICE Lights-Out Management: When the device is installed in a remote data center or in a computer room with limited access, ensure that the serial connections to both controllers are always connected to a serial console switch or similar equipment. This allows out-of-band remote control and support operations in case of network disruption or unexpected failures. <RXKDYHFRPSOHWHGFDEOLQJ\RXUGHYLFHIRUSRZHUQHWZRUNDFFHVVDQGVHULDOFRQQHFWLRQ 15 0LFURVRIW&RUSRUDWLRQ;
© Copyright 2024 ExpyDoc