1 Panel-Mountable Multifunctional Displays DA 221/223, DA 230 • • • • Red LED display with 13 mm Housing size for panel mounting 48 x 96 mm Feed voltage 24 V DC Supply voltage 115–230 V/50–60 Hz, Optional 24 V AC/DC Multifunctional Display DA 230 • Conversion of analogue input signals in ASCII Format for transference to a PC via RS 485/RS 232 I N F R A R E D T E M P E R A T U R E SOL UT ION S Type Input Analogue output DA 221 0(4)–20 mA (switchable) 0(4)–20 mA (switchable) charge ≤ 500 Ω optional DA 223 DA 230 Adjustable to the following measuring signals: 0(4)–20 mA, Ri = 50 Ω 0(2)–10 V, Ri ≥ 100 KΩ Range user-definable Thermocouples type K, S, J and T with cold junction compensation, Pt 100 0(4)–20 mA, charge ≤ 500 Ω 0(2)–10 V, charge ≥ 1 KΩ with automatic current/ voltage change-over RS 485 with point to point communication 2 binary inputs 24 V DC for controlling additional functions 3 potential-free contacts as make-or-break contact, breaking capacity 250 V/4 A, status indication via LED 0(4)–20 mA (switchable) charge ≤ 500 Ω optional Serial interface Control inputs Limit contacts Power supply Power consumption Measuring cycle Measuring range 2 switchpoints, adjustable via potentiometers on the front, configurable as min. or max. contact, or as make-or-break contact, breaking capacity 250 V AC/2A 115–230 V AC ± 10 %, 50–60 Hz, 5 V A 5 VA 400 m/sec Can be preset at out plant according to customer specifications 115–230 V/48–62 Hz Tolerance +10 %, -15 % opt. 24 V/0–62 Hz (AC/DC) 8 VA 20 m/sec Selectable: zero point, final value, decimal point and offset 3.5-digit/7 segment LED display, 4-digit/7 segment LED display, 13 mm, red 13 mm, red -1999 to +1999 -9999 to +9999 H 48 x W 96 x D 135 mm H 48 x W 96 x D 157 mm Cut-out for mounting 92 x 45 mm (depth with clamps 170 mm) Cut-out for mounting 92 x 45 mm 0.3 kg 0.5 kg IP 40 IP 54 24 V DC/50 mA to supply power to connected pyrometers 0 to +50 °C Display Display range Dimensions of unit Weight Protection class Feed voltage Ambient operating temperature Storage temperature Accuracy Electromagnetic compatibility Adjustable functions and parameters -25 to +85 °C ≤ 0.3 % of measuring range, at least ± 1 digit Conforming to EU Directive 89/336/EWG Switch point (limit contacts) Special function Special function (DA 230/S) The special software provides for the automatic recording of measurements during discontinuing processes, such as when measuring a pouring stream. The I N F R A R E D T E M P E R A T U R E SOL UT ION S measurement begins automatically when the set limit is exceeded. The recorded value is displayed when the time required for the measurement is over. Smoothing time constant Min. and max. value memory with internal or external reset. Switch point and hysteresis (limit contacts) Linearisation function with up to 10 inflection points. Validity check Type DA 230/S for automatic recording of measured values Optional Accessory ”CellaMevis“ PC software for transmission, display and storage of measured values with a single PC. KELLER HCW GmbH · Division MSR · Carl-Keller-Straße 2-10 · 49479 Ibbenbüren · Germany Tel. +49 (0) 54 51 85 0 · Fax +49 (0) 54 51 89 73 92 · www.keller-msr.de · [email protected] MSR072 1212/W/E · Technical changes reserved · Printed in Germany Technical Data
© Copyright 2024 ExpyDoc