PERFECT CARE WITH PERFECT AIR OPRAGON 8 FOR OPERATING THEATRES Unique Technology for Ultra-clean air in Operating theatres “Each person sheds around 10,000 skin particles per minute into the air when they walk, and around 10% of these particles carry bacteria. An individual will therefore spread between 1,000 and 8,000 bacterial particles per minute”. Source “Att förebygga vårdrelaterade infektioner - ett kunskapsunderlag” [“Preventing healthcarerelated infections – supporting documentation”]. Swedish National Board of Health and Welfare, 2006 USING THE LAWS OF NATURE TO PREVENT INFECTIONS The unique TAF technology (Temperature-controlled Airflow) enables us to combine safe function with a comfortable working environment. Instead of introducing a new LAF system – which takes up even more space and uses an even greater airflow than previous versions of LAF systems – we are focusing on increasing efficiency. Instead of using a HEPA filter as both a filter and air distributor we are separating these functions. When installing the Opragon, the filter is placed in connection to the operating room, and inside the operating room there is only the appropriate and highly efficient air distributors (“air showers”). Whilst traditional LAF ceilings require high air speeds to counteract the convection currents from staff, operating lights et cetera, we introduce a system, which adheres to the fundamental laws of nature, and which breaks the convection currents in an effective and energy efficient way. TAF TECHNOLOGY The TAF technology – slightly cooled, HEPA-filtered air – thanks to its higher density, falls to the floor at a speed dictated by the difference in temperature between the added air and the ambient air level with the operating table. This technology gives very stable and accurate control of the fall speed past the patient and the sterile dressed staff. It also gives us the option of keeping the balance between high enough speed to break the body convection of staff and patient, and at the same time avoiding unnecessary turbulence and draughts. Example of a TAF installation in a surgical environment In a TAF-installation (Temperature controlled Air Flow) the Opragon is surrounded with external air showers. The primary function is to ensure a constant room temperature with regards to varying heat loads in the room B A C D A C A External air showers: Control the room temperature. HEPAfiltered air facilitates sedimentation. B Opragon: Cooled HEPA-filtered air provides an ultra-clean operative zone. C Air curtains: Cooled HEPA-filtered air reduces entry of particles. D Exit air: All exit air is evacuated symmetrically at floor level. OPRAGON 8 Opragon 8 is designed for installation in the false ceiling in operating rooms that are used for infectionsensitive surgery. The unit is supplied with cooled, HEPA-filtered air from an external air treatment unit equipped with a heating/cooling battery. The air is supplied to the room through the eight air showers, their unique design combined with the cooler air’s higher density creates an area of ultra-clean air under the Opragon. This is made possible by effectively breaking the convection currents from staff and actively transporting away the bacteria carrying particles before the can whirl round in the room and contaminate the operation wound or the sterile instruments. In a complete TLA installation (see example on page 1), <5 or 10 cfu/m3 can be maintained in the surgical working area and in other parts of the theatre (provided that other hygiene and clothing requirements are also met). SPACE REQUIREMENTS Opragon takes up so little space in the ceiling that it is best to place the attachment for the surgical lights asymmetrically outside of the Opragon. In this way, the falling air stream is affected as little as possible. TECHNICAL SPECIFICATION Number of air showers: 8 in the Opragon Diameter: 1,970 mm. Normal flow m3/h: 2,800 Height: 250 – 350 mm. Connection: adapted individually Weigh: 100 kg Compliant with the latest European regulation. Opragon is laser cut in sheet metal, which is welded and powder-coated in the desired colour. It is also available in stainless steel. It can be connected from above or from the side, with circular or rectangular channels to suit the conditions in the room. The number of connections, their type and their location is customized for each project. Low ceiling height, ceiling mounted equipment is normally perfectly possible to combine with an Opragon installation since the installation. We offer tailor-made solutions for your specific requirements. Do you have specific requirements, do you need better ventilation in the entire surgical department, or is it simply a solution for specific operating rooms that you require? You may have an existing system that you want to make more effective. With our technology, we can help you in all of these situations. PERFECT CARE WITH PERFECT AIR Avidicare AB, Medicon Village Scheelevägen 2, SE-223 81 Lund, Sweden Phone +46 46 275 61 50 [email protected] www.avidicare.com
© Copyright 2024 ExpyDoc