DeboBase 3 T/F Alu200 *Alu3*

TECNICAL DATA SHEET
1/2
DeboBase 3 T/F Alu200
*Alu3*
DeboBase
DE BOER WATERPROOFING SOLUTIONS NV
Metropoolstraat 33, B-2900 SCHOTEN
mixture of talcum and sand
1 Upper coating : oxidised bitumen
2 Aluminium foil of 200 g/m²
3 Undercoating : oxidised bitumen
** sacrificial film
DESCRIPTION AND APPLICATION
A flexible waterproofing membrane consisting of an oxidised bitumen and a reinforcement with an aluminium foil of 200 g/m². The
upper side is finished with a mixture of talcum and sand and the underside is covered with a sacrificial film. It is used as a vapour
barrier class E4, for a highly humid interior climate for torched application.
TECHNICAL APPROVALS
NL-BSB-BD 007
BC2-310-0296-0123-01
BENOR/PTV 46-002
listed in BBA n° 98/3537
PACKING
Length (m)
Weight (kg)
Rolls / pallet
100 x 120 cm
10
30
25
Other dimensions and packing are possible on specific demand.
CONSUMER INFORMATION
Rolls have to be stored vertically. For instructions for use and specific roofing specifications we refer to our website: www.deboer.be .
De Boer Waterproofing Solutions NV - Metropoolstraat 33 - BE 2900 Schoten - Belgium - VAT BE 0403 711 030 - www.deboer.be
TECNICAL DATA SHEET
2/2
DeboBase 3 T/F Alu200
*Alu3*
DeboBase
TECHNICAL CHARACTERISTICS
Characteristics
Length x width
Thickness
Visual defects
Straightness
External fire performance
Reaction to fire
Tensile strength (L/T)
Elongation (L/T)
Resistance to root penetration
Water vapour properties (µ)
(µ)eq (*)
Resistance to static loading
Resistance to impact
Resistance to tearing (nail shank) (L/T)
Dimensional stability
Flexibility at low temperature
- initial
- after ageing (EN 1296)
- under UV (EN 1927)
Flow resistance at elevated temperature
- initial
- after ageing (EN 1296)
- under UV (EN 1927)
Joint strength: peel resitance
Joint strength: shear resitance
Watertightness
Test method /
classification
EN 1848-1
EN 1849-1
EN 1850-1
EN 1848-1
ENV 1187
EN 13501-1
EN 12311-1
EN 12311-1
EN 13948
EN 1931-method A
EN 1931-method A
EN 12730
EN 12691
EN 12310-1
EN 1107-1
EN 1109
EN 1110
EN 12316-1
EN 12317-1
EN 1928
Units
Expression of result
mxm
mm
N/50 mm
%
m
kg
mm
N
%
MLV ≥
MDV ± 5 %
Pass/no pass
Pass/no pass
in accordance with EN 13501-5
in accordance with EN 13501-1
MDV ± 20 %
MDV ± 15 abs
Pass/no pass
MLV ≥
MLV ≥
MLV ≥
MLV ≥
MDV ± 50
MLV ≤
°C
°C
°C
MLV ≤
Value / statement
10 x 1 m
3
Pass
Pass
NA
F
NPD / NPD
NPD / NPD
NA
650000
1950
NA
NA
NA / NA
NA
3
NA
NA
°C
°C
°C
N/50 mm
N/50 mm
-
MDV ± 50
MDV ± 250
Pass/no pass
80
NA
NA
NA
NA
Pass
MLV ≥
Watertightness after stretching at low
temperature
EN 13897
%
MLV ≥
NA
Adhesion of granules
EN 12039
%
MDV ± 10 %
NA
(*) Test report SGS INTRON Laboratory
MDV:
MLV:
NPD:
NA:
Manufacturer's Declared Value
Manufacturer's Limiting Value
No Performance Declared
Not Appicable
JOHAN PASTUER - Responsible Knowledge Centre Roof Techniques
Last modification: 2014-03-10
Version: 9
De Boer Waterproofing Solutions NV - Metropoolstraat 33 - BE 2900 Schoten - Belgium - VAT BE 0403 711 030 - www.deboer.be