Catalogue 04|2014 Domestic hot water modules Domestic hot water technology Valid for the UK PAW - Modular systems for domestic hot water technology and solar thermal installations - Contents Friwa Item Short name Product range Friwa - Introduction Overview product range Friwa Dimensioning product range Friwa Function overview controller FC3.8 Domestic hot water module Domestic hot water module Domestic hot water module Tank heat transfer module Domestic hot water module Equipment domestic hot water installation Product range Friwa Product range Friwa Product range Friwa FC3.8 FriwaMini FriwaMidi and cascade FriwaMaxi and cascade Tank heat transfer module Maxi FriwaMega and cascade Page 136 137 138 139 140 - 141 142 - 143 144 - 145 146 - 147 148 - 149 150 - 151 Product range Solex - Introduction Overview product range Solex HZ (heating installation) Function overview controller SC3.6 Function overview controller SC4.16 / SC8.24 Function overview controller SC5.14 Solar transfer station for buffer tanks up to 25 m² Solar transfer station for buffer tanks up to 50 m² Solar transfer station for buffer tanks up to 100 m² Solar transfer station for buffer tanks up to 200 m² Solar transfer station for buffer tanks up to 400 m² Solar transfer station for domestic hot water storage tanks up to 25 m² Solar transfer station for domestic hot water storage tanks up to 50 m² Solar transfer station for domestic hot water storage tanks up to 100 m² Solar transfer station for domestic hot water storage tanks up to 200 m² Solar transfer station for domestic hot water storage tanks up to 400 m² Product range Solex Product range Solex SC3.6 SC4.16 / SC8.24 SC5.14 SolexMini HZ SolexMidi HZ SolexMaxi HZ SolexMega HZ SolexMega-Kaskade HZ SolexMini TW SolexMidi TW SolexMaxi TW SolexMega TW SolexMega-Kaskade TW 154 - 155 156 157 158 159 160 - 161 162 - 163 164 - 165 166 - 167 168 - 169 170 - 171 172 - 173 174 - 175 176 - 177 178 - 179 Product range SolarBloC - Introduction Overview product range SolarBloC Function overview controller SC3.6 DrainBloC® Solar station SolarBloC midi Premium with controller Solar station SolarBloC midi Basic with optional controller Solar station SolarBloC midi 3-line station 2S Solar station SolarBloC midi 3-line station 2D Solar station SolarBloC midi Basic return station Stagnation cooler Mounting equipment SolarBloC midi - DN 20 Solar station SolarBloC maxi Premium with controller Solar station SolarBloC maxi Basic with optional controller Solar station SolarBloC maxi Basic return station Mounting equipment SolarBloC maxi - DN 25 Product range SolarBloC Product range SolarBloC SC3.6 DrainBloC® SolarBloC midi Premium SolarBloC midi Basic 3-line 2S 3-line 2D Return station Stagnation cooler SolarBloC midi SolarBloC maxi Premium SolarBloC maxi Basic Return station SolarBloC maxi 182 183 184 186 - 187 188 - 189 190 - 191 192 - 193 194 - 195 196 - 197 198 199 - 201 202 - 203 204 - 205 206 - 207 208 - 210 Solar station SolarBloC mega for large systems SolarBloC mega Friwa Mega / Maxi / Midi / Mini DHW modules Solex Solex HZ / TW Cascade/ Mega / Maxi / Midi / Mini Solar transfer stations SolarBloC mega Index Item number index General Terms and Conditions / Manufacturer's warranty Fax order 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu SolarBloC maxi 211 212 - 214 215 - 217 218 - 220 226 SolarBloC mega SolarBloC maxi Index DrainBloC / SolarBloC midi SolarBloC midi Solar stations 135 Product range Friwa Domestic hot water technology Product range Friwa Friwa modules comfortably and hygienically heat potable water using the principle of a flow-type heater. In a different way from normal domestic water, domestic water as food is not used for energy storage and stored for hours. An efficient plate heat exchanger heats it when necessary. The energy for heating the domestic water comes from a buffer storage tank which can be heated by various systems: solar installations as well as solid combustibles, conventional oil or gas boilers or other systems. FriwaMini The Friwa modules are very well suited for the application in a solar thermal installation. The excellent cooling of heating water in the efficient plate heat exchanger improves the efficiency of the solar circuit as the cold return reduces the medium temperature of the solar circuit. In case of large withdrawal differences the Friwa modules guarantee a constant outlet temperature at the hot water tap. The efficient control optimally sets the current withdrawal capacity of the heating flow rate by means of high-efficiency speed-controlled EC pumps. The control receives the required information to control the system via a new developed ultrasonic flow rate sensor and rapid temperature sensors, which immediately detect smallest temperature differences. The circulation pumps used in the Friwa modules meet the energy efficiency guidelines (EuP / ErP READY) of 2015. The control operates the pumps in different circulation modes which are adapted to the individual customer system requirements. FriwaMidi / FriwaMaxi Of course the Friwa modules correspond to the requirements of the German Drinking Water Ordinance (TrinkwV 2011). The required flame-treated valves can be mounted in the Friwa, thus there is no need for an external withdrawal. You can set the circulation return temperature individually during commissioning, so that the DVGW 551 requirements (German association for gas and water) of a maximum circulation cooling of 5 K are met in a transparent way and can be logged. The Friwa modules offer you a perfect comfort, optimum hygiene and a forward-looking energy saving operation. FriwaMega 136 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Overview product range Friwa Domestic hot water technology Design data FriwaMini DN 15 - up to 30 l/min (LK 1*), cold water inlet temperature = 10 °C Set hot water temperature Withdrawal of hot water with 45 °C at the preset hot water temperature Transmission capacity Primary flow temperature necessary Basic: 45 °C 19 l/min 26 l/min 47 kW 63 kW 60 °C (LK 1)* 70 °C Basic: 60 °C Premium: 45 °C Premium: 60 °C 19 l/min 48 kW 30 l/min 38 l/min 73 kW 92 kW 70 °C (LK 2)* 60 °C (LK 1)* 70 °C 30 l/min 74 kW 70 °C (LK 2)* For further information on the product see page 140/141. Design data FriwaMidiDN 20 - up to50 l/min (LK 1*), cold water inlet temperature = 10 °C Set hot water temperature Withdrawal of hot water with 45 °C at the preset hot water temperature Transmission capacity Primary flow temperature necessary 45 °C 50 l/min 64 l/min 121 kW 155 kW 60 °C (LK 1)* 70 °C 60 °C 53 l/min 129 kW 70 °C (LK 2)* For further information on the product see page 142/143. Design data FriwaMaxi DN 25 - up to 67 l/min(LK 1*), cold water inlet temperature = 10 °C Set hot water temperature Withdrawal of hot water with 45 °C at the preset hot water temperature Transmission capacity Primary flow temperature necessary 45 °C 67 l/min 86 l/min 163 kW 208 kW 60 °C (LK 1)* 70 °C 60 °C 72 l/min 176 kW 70 °C (LK 2)* For further information on the product see page 144/145. Design data FriwaMega DN 32 - up to 123 l/min (LK 1*), cold water inlet temperature = 10 °C Set hot water temperature Withdrawal of hot water with 45 °C at the preset hot water temperature Transmission capacity Primary flow temperature necessary 45 °C 123 l/min 130 l/min 300 kW 316 kW 60 °C (LK 1)* 70 °C 60 °C 133 l/min 324 kW 70 °C (LK 2)* For further information on the product see page 148/149. * Indication of performance as per SPF test procedure LK 1 = performance indicator 1 at a set hot water temperature of 45 °C at a primary flow temperature of 60 °C LK 2 = performance indicator 2 at a set hot water temperature of 60 °C at a primary flow temperature of 70 °C 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 137 Dimensioning product range Friwa Domestic hot water technology Dimensioning Friwa The performance of Friwa primarily depends on the temperature in the buffer tank, which delivers the energy to heat up the DHW. The demand of hot water depends on the flow and the number of consumers. In larger apartment buildings a statistic distribution of withdrawals can be detected. The following table shows a basic overview of the application range of Friwa module variants. Housing unit 70 °C / 60 °C / 10 °C 60 °C / 45 °C / 10 °C *** 52 °C / 45 °C / 10 °C *** Single-family house FriwaMini FriwaMini FriwaMini Two-family house FriwaMidi FriwaMidi FriwaMidi 3 FriwaMidi FriwaMidi FriwaMidi 5 FriwaMidi FriwaMidi FriwaMidi 10 FriwaMidi FriwaMidi FriwaMidi 15 FriwaMidi FriwaMidi FriwaMaxi 20 FriwaMidi FriwaMidi FriwaMaxi 30 FriwaMidi FriwaMaxi FriwaMaxi 50 FriwaMega FriwaMega FriwaMega 70 2x FriwaMaxi 2x FriwaMaxi 2x FriwaMega 100 2x FriwaMega 2x FriwaMega / *** During operation, a DHW temperature below 60 °C does not accord to DVGW 551 requirements (German association for gas and water). The compliance with water quality standards must be observed. 70 °C / 60 °C / 45 °C flow temperature 70 °C / DHW temperature 60 °C / DHW temperature 10 °C Basis of calculation is the DHW demand of max. 12 l/min and the simultaneity factor according to DIN 4708 Overview Friwa modules and equipment Range of application* Station/type Item no. Module with circulation** up to 19 l/min up to 30 l/min up to 50 l/min up to 67 l/min up to 123 l/min FriwaMini Basic FriwaMini Premium FriwaMidi FriwaMaxi FriwaMega 6404320 6404332 6405640 6406660 6407660 / 6404331 (external circulation) 6405641 (internal circulation) 6406661 (internal circulation) 6407661 + 6407662 (internal circulation) Enlarged range of application due to double cascade Range of application* Station/type / / up to 100 l/min up to 146 l/min up to 260 l/min FriwaMini Basic FriwaMini Premium FriwaMidi FriwaMaxi FriwaMega Module and pipe set necessary for double cascade: Basic modules / / 2 x 6405640 2 x 6406660 2 x 6407660 Pipe set for cascade / / 64042942 64042952 64042962 Optional: external circulation / / 6404136GH7 6404136GH10 6404136GH7 6404136GH10 6404136GH12 6404136GH7 6404136GH10 6404136GH12 See page 143. See page 145. See page 149. Other equipment See page 141. *Range of application at performance indicator 1 (LK 1, as per SPF test procedure): storage tank 60 °C, hot water = 45 °C, cold water = 10 °C **Friwa modules can be subsequently equipped with internal circulation sets - see equipment / = not possible 138 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Function overview controller - FC3.8 Domestic hot water technology Controller FC3.8 Friwa for DHW stations: for FriwaMini up to 30 l/min (as per SPF LK 1*) for FriwaMidi up to 50 l/min (as per SPF LK 1*) for FriwaMidi-Kaskade up to 100 l/min (as per SPF LK 1*) for FriwaMaxi up to 67 l/min (as per SPF LK 1*) for FriwaMaxi-Kaskade up to 146 l/min (as per SPF LK 1*) for FriwaMega up to 123 l/min (as per SPF LK 1*) for FriwaMega-Kaskade up to 260 l/min (as per SPF LK 1*) The controller FC3.8 sets the hot water temperature of the Friwa module via the speed control of the primary pump. The control functions are adjusted continuously during operation to the system conditions via an auto-adaptive algorithm. A circulation control and operation of the return distribution valve are additional functions of the controller. Different circulation modes are possible which can be adapted to the system requirements. The pumps are actuated via a PWM signal. An output for switching the return distribution valve is available. Self-explanatory pictograms indicate the active controller mode. Overview controller functions Controller FC3.8 Display Display with pictograms Operation 4 (5) pushbuttons Relay outputs 2 x 230 V, semiconductor relays 1 x 230 V, switching relay 1 x SELV (max. 24 V), potential-free relay 2 x PWM signal for speed control Sensor inputs 4 x PT1000 Flow rate sensors yes Heat quantity yes Circulation (dep. on time / temperature) yes Return distribution yes Preset systems: * Indication of performance as per SPF test procedure LK 1 = performance indicator 1 at a set hot water temperature of 45 °C at a primary flow temperature of 60 °C Friwa basic system Friwa basic system with circulation and return distribution Friwa basic system with circulation, return distribution and bypass 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 139 FriwaMini Basic/Premium Basic up to 19 l/min / Premium up to 30 l/min (as per SPF LK 1)* • Domestic hot water preparation using the principle of a flow-type water heater FriwaMini The compact and completely premounted station for comfortable and hygienic domestic hot water preparation using the principle of a flow-type heater. The water is heated up only at the moment when it is needed - a quick, safe and clean solution. Fresh hot and hygienically clean water is always available at any time without domestic hot water tank. The energy for heating the domestic water comes from a buffer storage tank which can be heated by various systems: solar installations as well as solid combustibles, conventional oil or gas boilers or other systems. The FriwaMini modules are very well suited for the application in a solar thermal installation. Connections: Primary circuit ¾" internal thread, domestic hot water circuit ¾" external thread Premounted on steel wall bracket - can be easily mounted to the wall Fully assembled with flat gaskets Full port ball valves Check valve in the return of the primary circuit, can be opened, Basic: 800 mm wc, Premium: 200 mm wc, prevents gravity circulation Domestic hot water circuit with piston valves easy handling, ball valves in the primary circuit key-activated FriwaMini Basic FriwaMini Premium Wilo Star-ST 15/4 3-speed Grundfos UPM2 15-75 CIL, High-efficiency pump Power consumption: 28-48 W Power consumption: 5-63 W optional: Circulation set Grundfos UPM2 15-75 CIL Item no. 640411 Heat exchanger 20 plates Heat exchanger 30 plates Controller FC3.8 Controller FC3.8 Sensors: 2 x Pt1000, 1 x VFS 2-40 l/min Sensors: 2 x Pt1000, 1 x VFS 2-40 l/min 140 Differential pressure diagram FriwaMini Pressure [kPa] Pressure [m wc] Technical data FriwaMini Basic/Premium - DN 15 Materials Valves and fittings Brass Gaskets Klingersil / EPDM Insulation EPP Heat exchanger Plates + connecting pieces: 1.4401 (AISI 316) Solder: 99.99 % copper Technical data Max. pressure primary 3 bars secondary 10 bars Max. operating 95 °C temperature Equipment Check valves, Basic 800 mm wc, primary Check valves, Premium 200 mm wc, primary Heat exchanger, Basic 20 plates, Type IC15 Heat exchanger, Premium 30 plates, Type IC15 Dimensions Connections primary ¾" int. thread secondary ¾" ext. thread Width 344 mm Height 645 mm Depth 249 mm Flow rate [l/h] 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu ontroller FC3.8 C The controller FC3.8 sets the hot water temperature of the Friwa module via the speed control of the primary pump. The control functions are adjusted continuously during operation to the system conditions via an auto-adaptive algorithm. A circulation control and operation of the return distribution valve are additional functions of the controller. Different circulation modes are possible which can be adapted to the system requirements. The pumps are actuated via a PWM signal. An output for switching the return distribution valve is available. Self-explanatory pictograms indicate the active controller mode. FriwaMini Friwa basic system Overview controller functions Controller FC3.8 isplay D Operation Relay outputs Display with pictograms 4 (5) pushbuttons 2 x 230 V, semiconductor relay 1 x 230 V, switching relay 1 x SELV (max. 24 V), potential-free relay 2 x PWM signal for speed controll 4 x PT1000 yes yes yes Sensor inputs Flow rate sensors Heat quantity Circulation (depending on time / temperature) Return distribution yes Friwa basic system with circulation and return distribution Friwa basic system with circulation, return distribution and bypass Design data FriwaMini, cold water inlet temperature = 10 °C Set hot water temperature Withdrawal of hot water with 45 °C at the preset hot water temperature Basic: 45 °C 19 l/min 26 l/min 47 kW 63 kW 60 °C (LK 1)* 70 °C Basic: 60 °C Premium: 45 °C Premium: 60 °C * Indication of performance as per SPF test procedure LK 1 = performance indicator 1 at a set hot water temperature of 45 °C at a primary flow temperature of 60 °C Illustration Transmission capacity Primary flow temperature necessary 19 l/min 48 kW 30 l/min 38 l/min 73 kW 92 kW 70 °C (LK 2)* 60 °C (LK 1)* 70 °C 30 l/min 74 kW 70 °C (LK 2)* LK 2 = performance indicator 2 at a set hot water temperature of 60 °C at a primary flow temperature of 70 °C FriwaMini DN 15 - DN 15 Item no. € / piece FriwaMini Basic - up to 19 l/min prim.: Wilo Star-ST 15/4, 3-speed 6404320 FriwaMini Premium - up to 30 l/min prim.: Grundfos UPM2 15-75 CIL, high-efficiency pump 6404332 FriwaMini Premium with circulation - up to 30 l/min prim.: Grundfos UPM2 15-75 CIL, high-efficiency pump sec.: Grundfos UPM2 15-75 CIL, high-efficiency pump 6404331 Circulation set for FriwaMini Premium 6404332 for external installation - with pump Grundfos UPM2 15-75 CIL - with piston valve and non return valve - connections: top: piston valve ¾" external thread bottom: ¾" union nut and ¾" external thread Circulation set for FriwaMini Premium 6404332 for external installation Return distribution set 1" internal thread for FriwaMini 3-way valve with actuator, Kvs value: 11 640411 Return distribution set 1" internal thread for FriwaMini Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 640425 141 FriwaMidi up to 50 l/min (as per SPF LK 1)* FriwaMidi-Kaskade up to 100 l/min (as per SPF LK 1)* • Domestic hot water preparation using the principle of a flow-type water heater FriwaMidi The compact and completely premounted station for comfortable and hygienic domestic hot water preparation using the principle of a flow-type heater. The water is heated up only at the moment when it is needed - a quick, safe and clean solution. Fresh hot and hygienically clean water is always available at any time without domestic hot water tank. FriwaMidi with integrated circulation set offers additional comfort and the possibility of thermal disinfection. The Friwa module without circulation set can be extended to a double cascade using a pipe set to realise higher tap flow rates. A circulation set for an external retrofitting can be subsequently mounted, if required. Circulation pump (optional) for maximum comfort impulse driven (operated on demand), dependent on time or temperature Full port ball valves Domestic hot water circuit with piston valves easy handling, ball valves in the primary circuit key-activated Pump can be isolated so that it can be replaced without draining Flow sensor in the hot water outlet for electronic flow rate and heat quantity measurement (cannot be calibrated) Optionally available: Flame-treated valves for sterile withdrawal of water according to German Drinking Water Ordinance (TrinkwV 2011) For information on dimensioning and controller functions, see pages 137-139. FriwaMidi FriwaMidi with circulation Grundfos UPM2 25-75, high-efficiency pump Grundfos UPM2 25-75, high-efficiency pump Power consumption: 5-63 W Power consumption: 5-63 W optional: Circulation set Grundfos UPM2 15-75 CIL Item no. 640412 (see page 150) Circulation: Grundfos UPM2 15-75 CIL Heat exchanger 40 plates Heat exchanger 40 plates Controller FC3.8 Controller FC3.8 Sensors: 1 temperature sensor primary, 2 temperature sensors secondary 142 optional: Pipe set DN 25 for FriwaMidi-Kaskade Item no. 64042942 Differential pressure diagram FriwaMidi Pressure [kPa] Pressure [m wc] Technical data FriwaMidi - DN 20 Materials Valves and fittings Brass Gaskets Klingersil / EPDM Insulation EPP Heat exchanger Plates + connecting pieces: 1.4401 (AISI 316) Solder: 99.99 % copper Technical data Max. pressure primary 3 bars secondary 10 bars Max. operating 95 °C temperature Kvs value primary 4.1 Kvs value secondary 3.4 Equipment Check valves 2 x 800 mm wc, primary Heat exchanger 40 plates, Type IC25 Dimensions Connections primary 1 ½" ext. thread secondary 1" ext. thread Optional: circulation line ¾" ext. thread Width 602 mm Height 795 mm Depth 298 mm Sensors: 1 temperature sensor primary, 2 temperature sensors secondary Flow rate [m³/h] 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Mounting example FriwaMidi Mounting example FriwaMidi-Kaskade FriwaMidi Illustration FriwaMidi DN 20 - DN 20 Item no. € / piece FriwaMidi - up to 50 l/min, basis module for double cascade prim.: Grundfos UPM2 25-75, high-efficiency pump 6405640 FriwaMidi with circulation - up to 50 l/min prim.: Grundfos UPM2 25-75, high-efficiency pump sec.: Grundfos UPM2 15-75 CIL, high-efficiency pump 6405641 Return distribution set 1¼" internal thread for FriwaMidi 3-way valve with actuator, Kvs value: 11 Return distribution set 1¼" internal thread for FriwaMidi 640423 Withdrawal valve for FriwaMidi/Maxi/Mega Flame-treated valves for sterile withdrawal of water. For additional installation inside the Friwa module, installation onto every piston valve in the domestic hot water circuit. Withdrawal valve for FriwaMidi/Maxi/Mega 640422 Accessories FriwaMidi-Kaskade - DN 20 Pipe set DN 25 for FriwaMidi-Kaskade Pipe set for cascading of two Friwa modules 6405640 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 25 for FriwaMidi-Kaskade 64042942 Circulation set in combination with pipe set for cascade, item no. 64042942 / 64042952 / 64042962 - with high-efficiency pump (different types) - with piston valves, non return valves and drain valve - connections: 6404136GH7 top: piston valve 1" external thread bottom: 1" union nut and transition to 1½'' - connections: 6404136GH10 top: piston valve 1½'' ext. thread bottom: 1½" union nut for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPM2 15-75 CIL for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPML 25-105 N 6404136GH7 6404136GH10 3-way switch valve with actuator - DN 40 for switching between single storage tanks, DN 40, 1½" internal thread, setting time for 90°: 35 sec., Kvs value = 25 3-way switch valve with actuator - DN 40 Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 6404242 143 FriwaMaxi up to 67 l/min (as per SPF LK 1)* FriwaMaxi-Kaskade up to 146 l/min (as per SPF LK 1)* • Domestic hot water preparation using the principle of a flow-type water heater FriwaMaxi The compact and completely premounted station for comfortable and hygienic domestic hot water preparation using the principle of a flow-type heater. The water is heated up only at the moment when it is needed - a quick, safe and clean solution. Fresh hot and hygienically clean water is always available at any time without domestic hot water tank. FriwaMaxi with integrated circulation set offers additional comfort and the possibility of thermal disinfection. The Friwa module without circulation set can be extended to a double cascade using a pipe set to realise higher tap flow rates. A circulation set for an external retrofitting can be subsequently mounted, if required. Circulation pump (optional) for maximum comfort impulse driven (operated on demand), dependent on time or temperature Full port ball valves Domestic hot water circuit with piston valves easy handling, ball valves in the primary circuit key-activated Pump can be isolated so that it can be replaced without draining Flow sensor in the hot water outlet for electronic flow rate and heat quantity measurement (cannot be calibrated) Optionally available: Flame-treated valves for sterile withdrawal of water according to German Drinking Water Ordinance (TrinkwV 2011) For information on dimensioning and controller functions, see pages 137-139. FriwaMaxi FriwaMaxi with circulation Grundfos UPM GEO 25-85, high-efficiency pump, PWM signal Grundfos UPM GEO 25-85, high-efficiency pump, PWM signal Power consumption: 8-87 W Power consumption: 8-87 W optional: Circulation set Grundfos UPM2 15-75 CIL Item no. 640412 (see page 150) Circulation: Grundfos UPM2 15-75 CIL Heat exchanger 60 plates Heat exchanger 60 plates Controller FC3.8 Controller FC3.8 Sensors: 2 temperature sensors primary, 2 temperature sensors secondary 144 optional: Pipe set DN 32 for FriwaMaxi-Kaskade Item no. 64042952 Differential pressure diagram FriwaMaxi Pressure [kPa] Pressure [m wc] Technical data FriwaMaxi - DN 25 Materials Valves and fittings Brass Gaskets Klingersil / EPDM Insulation EPP Heat exchanger Plates + connecting pieces: 1.4401 (AISI 316) Solder: 99.99 % copper Technical data Max. pressure primary 3 bars secondary 10 bars Max. operating 95 °C temperature Kvs value primary 5.6 Kvs value secondary 5.2 Equipment Check valves 2 x 800 mm wc, primary Heat exchanger 60 plates, Type IC25 Dimensions Connections primary 2" ext. thread secondary 1 ¼" ext. thread Optional: circulation line ¾" ext. thread Width 602 mm Height 795 mm Depth 298 mm Sensors: 2 temperature sensors primary, 2 temperature sensors secondary Flow rate [m³/h] 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Mounting example FriwaMaxi-Kaskade FriwaMaxi Mounting example FriwaMaxi Illustration FriwaMaxi DN 25 - DN 25 Item no. € / piece FriwaMaxi - up to 67 l/min, basis module for double cascade prim.: Grundfos UPM GEO 25-85, high-efficiency pump 6406660 FriwaMaxi with circulation - up to 67 l/min prim.: Grundfos UPM GEO 25-85, high-efficiency pump sec.: Grundfos UPM2 15-75 CIL, high-efficiency pump 6406661 Return distribution set 1¼" internal thread for FriwaMaxi 3-way valve with actuator, Kvs value: 16 Return distribution set 1¼" internal thread for FriwaMaxi 640424 Withdrawal valve for FriwaMidi/Maxi/Mega Flame-treated valves for sterile withdrawal of water. For additional installation inside the Friwa module, installation onto every piston valve in the domestic hot water circuit. Withdrawal valve for FriwaMidi/Maxi/Mega 640422 Accessories FriwaMaxi-Kaskade - DN 25 Pipe set DN 32 for FriwaMaxi-Kaskade Pipe set for cascading of two Friwa modules 6406660 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 32 for FriwaMaxi-Kaskade 64042952 Circulation set in combination with pipe set for cascade, item no. 64042942 / 64042952 / 64042962 - with high-efficiency pump (different types) - with piston valves, non return valves and drain valve - connections: 6404136GH7 top: piston valve 1" ext. thread bottom: 1" union nut and transition to 1½'' - connections: 6404136GH10 top: piston valve 1½'' external thread bottom: 1½" union nut - connections: 6404136GH12 top: piston valve 1½'' external thread bottom: 1½" union nut for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPM2 15-75 CIL for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPML 25-105 N for FriwaMaxi-/Mega-Kaskade, Grundfos UPM XL 25-125 N 6404136GH7 6404136GH10 6404136GH12 3-way switch valve with actuator - DN 40 for switching between single storage tanks, DN 40, 1½" internal thread, setting time for 90°: 35 sec., Kvs value = 25 3-way switch valve with actuator - DN 40 Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 6404242 145 Tank heat transfer module Maxi up to 63 l/min Tank heat transfer module Maxi • for charging/preheating small domestic hot water tanks via large buffer tank systems with high tap performances The compact and completely premounted tank heat transfer module, completely insulated, with generously dimensioned and high-efficiency stainless steel plate heat exchanger, with adjustable controller, assures a simple and quick installation as well as a safe commissioning. Premounted on steel wall bracket can be easily mounted to the wall with snap-in mechanism Full port ball valves, in the primary circuit key-activated Domestic hot water circuit with piston valves piston valves with drain valve in the secondary circuit Pumps can be completely isolated, no draining during servicing Integrated drain valves Fill and drain valve at the heat exchanger to drain the primary and secondary circuit, vent valve at the highest point at the heat exchanger in the primary and secondary circuit Pressure relief valve 10 bars to protect the station Flow sensor in the hot water outlet for electronic flow rate and heat quantity measurement (cannot be calibrated). Optionally available: Flame-treated valves for sterile withdrawal of water according to German Drinking Water Ordinance (TrinkwV 2011) Tank heat transfer module Maxi - DN 25 Pump primary: Grundfos UPML 25-105, high-efficiency pump, PWM-C Power consumption: 3-140 W Pump secondary: Grundfos UPML 25-105 N high-efficiency pump, PWM Power consumption: 3-140 W Heat exchanger 60 plates Controller FC4.13 Sensors: 1 temperature sensor primary, 2 temperature sensors secondary 146 Differential pressure diagram Tank heat transfer module Maxi Pressure [kPa] Pressure [m wc] Technical data Tank heat transfer module Maxi - DN 25 Materials Valves and fittings Brass Gaskets Klingersil / EPDM Insulation EPP Heat exchanger Plates + connecting pieces: 1.4401 (AISI 316) Solder: 99.99 % copper Technical data Max. pressure primary 3 bars secondary 10 bars Max. operating 95 °C temperature Kvs value primary 5.5 Kvs value secondary 5 Equipment Check valves 2 x 200 mm wc Heat exchanger 60 plates, Type IC25 Dimensions Connections primary 1 ½" ext. thread secondary 1 ¼" ext. thread Width 602 mm Height 795 mm Depth 298 mm Flow rate [m³/h] 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Controller FC4.13 The controller FC4.13 sets the hot water temperature of the tank heat transfer module via the speed control of the primary pump. The control functions are adjusted continuously during operation to the system conditions via an autoadaptive algorithm. The operation of the return distribution valve is an additional function of the controller. Different operating modes are possible which can be adapted to the system requirements. The pumps are actuated via a PWM signal. An output for switching the return distribution valve is available. Self-explanatory pictograms indicate the active controller mode. Tank heat transfer module Maxi Tank heat transfer module Maxi - Basic system Overview controller functions Controller FC4.13 Display Operation Relay outputs Display with pictograms 7 pushbuttons 3 x 230 V, semiconductor relays 1 x potential-free relay 4 x PWM / 0-10 V 9 (10) x Pt1000 1 x impulse input V40 yes yes yes Outputs Sensor inputs Flow rate sensors Heat quantity Return distribution Tank heat transfer module Maxi - Basic system with return distribution Design data - Tank heat transfer module Maxi- DN 25 et hot water S temperature Cold water inlet temperature 50 °C Buffer tank flow temperature 10 °C Max. transferrable power Buffer tank return temperature 55 °C 127.8 kW *1) 46.0 l/min 23.9 °C 60 °C 162.9 kW *1) 58.7 l/min 20.4 °C 70 °C 174.7 kW *2) 63.0 l/min 15.8 °C 60 °C 140.1 kW *1) 44.9 l/min 26.0 °C 70 °C 196.6 kW *2) 63.0 l/min 19.4 °C 70 °C 190.1 kW *1) 54.9 l/min 23.6 °C 55 °C 10 °C 60 °C 10 °C 50 °C 45 °C 55 °C 21.6 kW *2) 63.0 l/min 45.2 °C 55 °C 50 °C 60 °C 21.6 kW *2) 63.0 l/min 50.2 °C 60 °C 55 °C 70 °C 21.6 kW *2) 63.0 l/min 55.1 °C Recharging *1) *2) Max. flow rate primary = 60 l/min corresponds to 2.0 m of residual head of the primary pump Max. flow rate secondary = 63 l/min corresponds to 2.0 m of residual head of the primary pump Illustration Tank heat transfer module Maxi- DN 25 Item no. € / piece prim.: Grundfos UPML 25-105, high-efficiency pump, PWM-C sec.: Grundfos UPML 25-105 N, high-efficiency pump, PWM 6436465 eturn distribution set DN 32 R 3-way valve with actuator, Kvs value: 16 Return distribution set DN 32 640424 ithdrawal valve W Flame-treated valves for sterile withdrawal of water. For additional installation inside the tank heat transfer module, for tank heat transfer module 2 x necessary. Withdrawal valve Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 640422 147 FriwaMega up to 123 l/min (as per SPF LK 1)* FriwaMega-Kaskade up to 260 l/min • Domestic hot water preparation using the principle of a flow-type water heater FriwaMega The compact and completely premounted station for comfortable and hygienic domestic hot water preparation using the principle of a flow-type heater. The water is heated up only at the moment when it is needed - a quick, safe and clean solution. Fresh hot and hygienically clean water is always available at any time without domestic hot water tank. FriwaMega circulation sets for internal retrofitting offer additional comfort and the possibility of thermal disinfection. The Friwa module without circulation set can be extended to a double cascade using a pipe set to realise higher tap flow rates. A circulation set for an external retrofitting can be subsequently mounted, if required. Circulation pump (optional) for maximum comfort impulse driven (operated on demand), dependent on time or temperature Full port ball valves Domestic hot water circuit with piston valves easy handling, ball valves in the primary circuit key-activated Pump can be isolated so that it can be replaced without draining Flow sensor in the cold water supply for electronic flow rate and heat quantity measurement (cannot be calibrated) Optionally available: Flame-treated valves for sterile withdrawal of water according to German Drinking Water Ordinance (TrinkwV 2011) For information on dimensioning and controller functions, see pages 137-139. FriwaMega Grundfos Magna 25-100, high-efficiency pump Power consumption: 10-185 W optional: Circulation set I Grundfos UPM2 15-75 CIL Item no.: 6404134GH7 (see page 150) Circulation set II Grundfos UPML 25-105 N Item no.: 6404135GH10 (see page 150) Power consumption: 5 - 63 W Power consumption: 6 - 87 W Heat exchanger:2 x 60 plates, Type IC25 Controller FC3.8 148 Sensors: 2 temperature sensors primary, 2 temperature sensors secondary Differential pressure diagram FriwaMega Pressure [kPa] Pressure [m wc] Technical data FriwaMega - DN 32 Materials Valves and fittings Brass Gaskets: o-rings EPDM Flat gaskets AFM 34, asbestos-free Insulation EPP Heat exchanger Plates + connecting pieces: 1.4401 (AISI 316) Solder: 99.99 % copper Technical data Max. pressure prim.: 3 bars, sec.: 10 bars Max. operating 95 °C temperature Kvs value primary 11.8 Kvs value secondary 10 Equipment Check valves 2 x 800 mm wc, primary Heat exchanger 2 x 60 Plates, Type IC25 Dimensions Connections prim.: 1 ½" int. thread, sec.: 1 ½" ext. thread top: 1" ext. thread, Circulation set I bottom: 1¾" top: 1 ¼" ext. thread, Circulation set II bottom: 1¾" Width 710 mm Height 1430 mm Depth 920 mm Flow rate [m³/h] 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Mounting example FriwaMega-Kaskade FriwaMega Mounting example FriwaMega Illustration FriwaMega - DN 32 Item no. € / piece FriwaMega - up to 123 l/min, basis module for double cascade prim.: Grundfos Magna 25-100, high-efficiency pump 6407660 FriwaMega mit Zirkulation - up to 123 l/min prim.: Grundfos Magna 25-100, high-efficiency pump sec.: Grundfos UPM2 15-75 CIL, high-efficiency pump prim.: Grundfos Magna 25-100, high-efficiency pump sec.: Grundfos UPMLGEO 25-105 N, high-efficiency pump 6407662 6407661 3-way switch valve with actuator - DN 40 for switching between single storage tanks, DN 40, 1½" internal thread, setting time for 90°: 35 sec., Kvs value = 25 3-way switch valve with actuator - DN 40 6404242 Withdrawal valve for FriwaMidi/Maxi/Mega Flame-treated valves for sterile withdrawal of water. For additional installation inside the Friwa module, installation onto every piston valve in the domestic hot water circuit. Withdrawal valve for FriwaMidi/Maxi/Mega 640422 Accessories FriwaMega-Kaskade - DN 32 Pipe set DN 40 for FriwaMega Pipe set for cascading of two Friwa modules 6407660 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 40 for FriwaMega 64042962 Circulation set in combination with pipe set for cascade, item no. 64042942 / 64042952 / 64042962 - with high-efficiency pump (different types) - with piston valves, non return valves and drain valve - connections: - connections: 6404136GH7 6404136GH10 top: piston valve 1" ext. thread top: piston valve 1½'' external bottom: 1" union nut and thread transition to 1½'' bottom: 1½" union nut - connections: 6404136GH12 top: piston valve 1½'' external thread bottom: 1½" union nut for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPM2 15-75 CIL for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPML 25-105 N for FriwaMaxi-/Mega-Kaskade, Grundfos UPM XL 25-125 N 6404136GH7 6404136GH10 6404136GH12 -way switch valve with actuator - DN 50 3 for switching between single storage tanks, DN 50, 2" internal thread, setting time for 90°: 35 sec., Kvs value = 40 3-way switch valve with actuator - DN 50 Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 6404244 149 Domestic hot water equipment Illustration PU Item no. € / piece Friwa Service water mixing valve The PAW service water mixing valve is used for setting a constant temperature of the water withdrawn from solar or buffer storage tanks between 30 °C and 70 °C. With this valve, the danger of scalding due to hot water from the storage tank is reduced considerably. A must-have for each correctly designed service water solar system. Housing: Precision of settings: Max. operating temperature: Max. operating pressure: Range of setting: Withdrawal: Connections 56311: Connections 56321: Brass, insensitive to calcification, resistant to dezincification +/- 2 °C 98 °C PN 10 30-70 °C 39 l/min (DP = 1.5 bars) thread connection with ¾" external thread solder sleeve d = 22 mm Service water mixing valve ¾" ext. thr. Service water mixing valve with 22 mm solder sleeve 1 1 56311 56321 1 563907 1 5639071 1 640411 1 640412 Circulation set for FriwaMega 6407660 for an internal retrofitting, Grundfos UPM2 15-75 CIL 1 6404134GH7 Circulation set for FriwaMega 6407660 for an internal retrofitting, Grundfos UPML 25-105 N 1 6404135GH10 Domestic hot water safety group ¾" Safety group for hot water storage tank, with shut off and adjustable check valve. For horizontal installation. With seat made of stainless steel. Brass housing. Chromed. Certified in conformity to EN 1487. Opening pressure 7 bars, max. power 10 kW Domestic hot water safety group ¾" Discharge tundish for domestic hot water safety group The discharge tundish absorbs water splashes during draining via the pressure relief valve and leads them into the drain line. Discharge tundish for domestic hot water safety group Circulation set for FriwaMini Premium 6404332 for external installation - with pump Grundfos UPM2 15-75 CIL - with piston valve and non return valve - connections: top: piston valve ¾" external thread bottom: ¾" union nut and ¾" external thread Circulation set for FriwaMini Premium 6404332 for external installation Circulation set for FriwaMidi 6405640 / Maxi 6406660 for internal installation - with pump Grundfos UPM2 15-75 CIL - with piston valve and non return valve - connections: top: ½" external thread, self-sealing bottom: piston valve 1" external thread Circulation set for FriwaMidi 6405640 / Maxi 6406660 for internal installation Circulation set for FriwaMega 6407660 for an internal retrofitting - with high-efficiency pump (different types) - piston valve with non retorn valve: DN 20 (6404134GH7), DN 25 (6404135GH10) - connections: top: double nipple 1" ext. thr. (6404134GH7), 1¼" ext. thr. (6404135GH10) bottom: 1¾" union nut 150 Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu Illustration PU Item no. € / piece Circulation set in combination with pipe set for cascade, item no. 64042942 / 64042952 / 64042962 - with high-efficiency pump (different types) - with piston valves, non return valves and drain valve - connections: 6404136GH7 - connections: 6404136GH10 - connections: 6404136GH12 top: piston valve 1" ext. thr. top: piston valve 1½'' ext. thr. top: piston valve 1½'' ext. thr. bottom: 1" union nut and bottom: 1½" union nut bottom: 1½" union nut transition to 1½'' for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPM2 15-75 CIL 1 6404136GH7 for FriwaMidi/Maxi/Mega-Kaskade, Grundfos UPML 25-105 N 1 6404136GH10 for FriwaMaxi-/Mega-Kaskade, Grundfos UPM XL 25-125 N 1 6404136GH12 1 640425 1 640423 1 640424 1 6404242 Return distribution set 1" internal thread for FriwaMini 3-way valve with actuator, Kvs value: 11 Return distribution set 1" internal thread for FriwaMini Return distribution set 1¼" internal thread for FriwaMidi 3-way valve with actuator, Kvs value: 11 Return distribution set 1¼" internal thread for FriwaMidi Return distribution set 1¼" internal thread for FriwaMaxi 3-way valve with actuator, Kvs value: 16 Return distribution set 1¼" internal thread for FriwaMaxi 3-way switch valve with actuator - DN 40 for switching between single storage tanks, DN 40, 1½" internal thread, setting time for 90°: 35 sec., Kvs value = 25 3-way switch valve with actuator - DN 40 3-way switch valve with actuator - DN 50 for switching between single storage tanks, DN 50, 2" internal thread, setting time for 90°: 35 sec., Kvs value = 40 3-way switch valve with actuator - DN 50 1 6404244 1 640422 1 64042942 1 64042952 1 64042962 Withdrawal valve for FriwaMidi/Maxi/Mega Flame-treated valves for sterile withdrawal of water. For additional installation inside the Friwa module, installation onto every piston valve in the domestic hot water circuit. Withdrawal valve for FriwaMidi/Maxi/Mega Pipe set DN 25 for FriwaMidi-Kaskade Pipe set for cascading of two Friwa modules 6405640 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 25 for FriwaMidi-Kaskade Pipe set DN 32 for FriwaMaxi-Kaskade Pipe set for cascading of two Friwa modules 6406660 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 32 for FriwaMaxi-Kaskade Pipe set DN 40 for FriwaMega-Kaskade Pipe set for cascading of two Friwa modules 6407660 - with 2 two-way valves for switching - with mounting rail for an easy wall assembly - pipe set insulated Pipe set DN 40 for FriwaMega-Kaskade Prices excl. VAT • 04/2014 • Printed in Germany PAW GmbH & Co. KG • D-31789 Hameln • Germany • Tel.: +49-5151-9856-0 • Fax: +49-5151-9856-98 • [email protected] • www.paw.eu 151
© Copyright 2025 ExpyDoc