2 Automotive PLC and programming tools with CAN .................................................. 5 CAN I/O & CAN PLC .......................................................................... 5 CAN I/O & CAN PLC Waterproof ................................................................... 8 CAN I/O & CAN PLC Waterproof PRO .............................................................. 10 M2600 CAN PLC ............................................................................. 12 M2600 ECO CAN PLC ......................................................................... 14 Micro PLC CAN .............................................................................. 16 Micro PLC CAN 4 I/O .......................................................................... 18 Micro PLC CAN 4 ANA ......................................................................... 19 Micro PLC CAN LIN ........................................................................... 21 CAN Relay Box .............................................................................. 22 MRS Developers Studio ........................................................................ 24 Automotive PLC and programming tools .......................................................... 25 Micro PLC ................................................................................. 25 Controller M3 ............................................................................... 28 Controller M4 ............................................................................... 30 Controller M1 ............................................................................... 31 Programming tool MRS Realizer I .................................................................. 33 Z-graph ................................................................................... 34 Gateways .................................................................................. 35 CAN Gateway Module ......................................................................... 35 Universal Gateway ............................................................................ 37 Universal Gateway 5x CAN ...................................................................... 39 Micro Gateway .............................................................................. 40 CAN/RS485 Gateway .......................................................................... 42 Controller .................................................................................. 44 PROP CAN ................................................................................ 44 Motorcontroller 5A CAN ........................................................................ 46 Motorcontroller 10A CAN ....................................................................... 48 6-fold PROP CAN ............................................................................ 50 Proportional amplifier .......................................................................... 51 Reference voltage-DC/DC converter ................................................................ 53 Referenzspannung-DC/DC converter 2A .............................................................. 55 Touch Panel ................................................................................ 56 Touch Panel ................................................................................ 56 Time Relay ................................................................................. 58 Time relay switch-on delay ....................................................................... 58 Time relay switch-on delay compact................................................................. 60 Time relay switch on delay adjustable................................................................ 62 Time relay switch-off delay ....................................................................... 65 Time relay switch-off delay compact................................................................. 67 Time relay switch-off delay adjustable ............................................................... 69 Time relay switch-on and off delay .................................................................. 72 Time relay switch-on and off delay compact ............................................................ 74 Impulse Relay ............................................................................... 76 Impulse relay ............................................................................... 76 Impulse relay compact ......................................................................... 78 Impulse relay adjustable ........................................................................ 80 Toggle relay ................................................................................ 82 Toggle relay ................................................................................ 82 Toggle relay 2 ............................................................................... 84 Toggle relay compact .......................................................................... 86 Toggle relay time limited ........................................................................ 88 Toggle relay time limited compact .................................................................. 90 Voltage monitor Relay ........................................................................ 92 Voltage range monitor.......................................................................... 92 Voltage monitor relay with reset ................................................................... 95 Frequency monitor ........................................................................... 97 Frequency monitor ............................................................................ 97 Flasher Unit ................................................................................ 99 Flasher unit ................................................................................ 99 3 Universal flasher unit ......................................................................... 101 Universal flasher LED.......................................................................... 103 Standard Relay.............................................................................. Standard relay ............................................................................... Standard relay with special terminals................................................................ Micro Relay................................................................................ Power relay................................................................................ Power relay with screw terminals ................................................................... Relay with special contacts...................................................................... Solid state relay .............................................................................. Special Relays.............................................................................. Special relays............................................................................... Relay Accessories........................................................................... Diode combinations........................................................................... Relay sockets for flat pin........................................................................ DIN rail adaptor .............................................................................. Load dump protection module ..................................................................... Housing and Baseplates ....................................................................... Housing and baseplates........................................................................ 4 106 106 109 111 113 115 116 118 120 120 123 123 125 126 127 128 128 CAN I/O & CAN PLC DESCRIPTION The compact automotive CAN I/O & CAN PLC module serves for the extension of existing CAN controllers, but can also used as standalone PLC controller. Optional it can be equipped with RS485 or RS232 interface. Graphic programming with the Softwaretool CANgraph and suitable Flash program tool or programming with a C-development system. FUNCTION CANopen E/A-module Freescale HCS08 processor with flash-technology (Option to write many times) CAN high- / low-speed, RS485 or RS232 bus can be used to communicate with further systems and offer an easy integration in existing systems 6 digital outputs and/or analog inputs (programmable) 2 digital outputs and/or digital inputs (programmable) 6 analog inputs additionally Protected from polarity and electrical transient ones Outputs: Power-Highside-Driver, overload-proof, with digital status By use of the powerful processor, the module is CANopen- und SAE J1939-compliant Software compatible to CAN I/O Waterproof APPLICATION EXAMPLES Independent PLC controller Output expansion Input expansion Control of operating unit Light control Inquiry of sensors TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V DC Connector 22pol. Molex Mini Fit Junior Protection class IP 53 Housing dimensions 60 x 60 x 30 mm e1 approval number 03 5385 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 5 ORDER TABLE Technical Data Ausführung Housing Ordering Nr. CAN I/ O & CAN PLC 6 analog inputs, 8 I/ Os G7 1.033.300.00E CAN I/ O & CAN PLC - RPM 6 analog inputs, 8 I/ Os (2x frequency input) G7 1.033.302.00E CAN I/ O & CAN PLC - Current In 6 analog inputs, 8 I/ Os (3x current input) G7 1.033.303.00E CAN I/ O & CAN PLC - PWM Out 6 analog inputs, 8 I/ Os (6x PWM) G7 1.033.304.00E CAN I/ O & CAN PLC - 5V Output 6 analog inputs, 8 I/ Os (5V output) G7 1.033.305.00E CAN I/ O & CAN PLC - Current In, PWM Out 6 analog inputs, 8 I/ Os (3x current input, 6x PWM) G7 1.033.306.00E CAN I/ O & CAN SPS - ANAs 30V 6 analog inputs, 8 I/ Os (ANAs 30V) G7 1.033.308.00E CAN I/ O & CAN PLC - RPM, PWM 6 analog inputs, 8 I/ Os (2x RPM, 6x PWM) G7 1.033.309.00E CAN I/ O & CAN PLC - Low Speed 6 analog inputs, 8 I/ Os (low speed) G7 1.033.310.00E CAN I/ O & CAN PLC - Current In 6 analog inputs, 8 I/ Os (4x Current-Input) G7 1.033.30A.00E CAN I/ O & CAN PLC mit 5V Output + Pull ups 6 analog inputs, 8 I/ Os (3x Pull up) G7 1.033.30B.00E CAN I/ O & CAN PLC - Pull up 6 analog inputs, 8 I/ Os (3x Pull up) G7 1.033.30C.00E CAN I/ O & CAN PLC - PT1000 6 analog inputs, 8 I/ Os (3x PT1000) G7 1.033.30D.00E CAN I/ O & CAN PLC - RPM 4,5V / PWM 6 analog inputs, (2x RPM 4,5V / G7 2x PWM) 1.033.30E.00E CAN I/ O & CAN PLC - PWM IN 6 analog inputs, (2x PWM IN / / PWM OUT PWM OUT) G7 1.033.30G.00E CAN I/ O & CAN PLC - PU / Freq-IN 6 analog inputs, 8 I/ Os (PU / Freq-IN) G7 1.033.30H.00E CAN I/ O & CAN PLC - PT1000 / RS232 6 analog inputs, 8 I/ Os (5x PT1000 / RS232) G7 1.033.30J.00E CAN I/ O & CAN PLC - RPM, PWM, VRef 6 analog inputs, (2x RPM, 6 x PWM, VRef) G7 1.033.30K.00E CAN I/ O CAN/ RS485 Gateway 6 analog inputs, 8 I/ Os (RS485) G7 1.033.320.00E CAN I/ O CAN/ RS232 Gateway 6 analog inputs, 8 I/ Os (RS232) G7 1.033.330.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit CAN I/O 1.100.110.00 Programming tool MRS Developers Studio 1.100.100.00 6 Technical Data Ordering Nr. PCAN-USB Interface 105358 Cable set for CAN I/O 106817 Plug package for CAN I/O 106940 Spout for cable set 102892 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 7 CAN I/O & CAN PLC Waterproof DESCRIPTION The compact automotive suited CAN I/O & CAN PLC Waterproof module serves for the extension of existing CAN controllers. The high protection class IP 68 (permanently waterproof and dust-tight) and the free graphical programmability allows multiple uses in automotive application. FUNCTION CANopen E/A-module 6 analog inputs 8 digital inputs / digital outputs 6 PWM-outputs with 2,5 A 1 reference voltage 5 V Protected against polarity and electrical transients CANopen and SAE J1939 able Software compatible to CAN I/O & CAN PLC APPLICATION EXAMPLES Independent PLC controller Input and output expansion TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V DC Connector Sicma 211 PL249S0005 Protection class IP 68 Housing dimensions without connector 60 x 60 x 30 mm Housing dimensions with connector 60 x 80 x 30 mm E1 approval number 04 7181 Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ausführung Housing Ordering Nr. CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os of G7 1.053.300.0000E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; RPM + of 5 Vref G7 1.053.302.0000E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; current of inputs G7 1.053.303.0000E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; RPM, of RPM+5V / Perm.?ON 5V / Perm. ON G7 1.?053.?302.?1200E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; RPM, of RPM+5VRef III 5V G7 1.?053.?304.?1200E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; RPM, of RPM+8V 8V G7 1.?053.?305.?0000E CAN I/ O & CAN PLC Waterpro- 6 analog inputs; 8 I/ Os; Pull-up G7 1.?053.?306.?0000E 8 Technical Data Ausführung Housing of Pull-Up Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit CAN I/O Waterproof 1.100.110.32 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set CAN I/O Waterproof 112342 Connector package for CAN I/O Waterproof 110421 Crimp contacts 2,8 mm / 1,0 - 2,5 mm² 109947 Crimp contacts 1,5 mm / 1,3 - 2,0 mm² 109949 Blanking plugs FCI Filler Plug 110268 Lens cap 111441 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 9 Ordering Nr. CAN I/O & CAN PLC Waterproof PRO DESCRIPTION The compact automotive suited CAN I/O & CAN PLC Waterproof PRO module serves for the extension of existing CAN controllers. The high protection class IP68 (permanently waterproof and dust-tight) and the free graphical programmability allows multiple uses in automotive application. FUNCTION CANopen E/A-module CAN high- or low-speed or RS485 bus can be used to communicate with further systems and offer an easy integration in existing systems Vref as option possible 2 digital inputs 6 analog inputs (Pull-up & Pull-down software selectable) 8 analog inputs or digital-/PWM outputs Protected from polarity and electrical transient ones Outputs: Power-Highside-Driver, overload-proof, with digital status By use of the powerful processor, the module is CANopen- und SAE J1939-compliant APPLICATION EXAMPLES Harvesting machines Tractors and equipment for farming Snowmobiles and snow groomers Hydraulic control for commercial vehicles Cranes, lifting platforms TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V Protection class IP 68 Compact housing 60 x 60 x 30 mm e1 approval number 03 6710 Design may be subject of change – no guarantee for this information. DESIGN ORDER TABLE Technical Data Ausführung Housing 10 Ordering Nr. CAN I/ O & CAN PLC Waterpro- 5 V Vref, Wake-up, CAN-HS, of PRO RS232 G7 1.041.301.1000 CAN I/ O & CAN PLC Waterpro- 5 V Vref, Wake-up, CAN-HS, of PRO RS485 G7 1.041.321.1000 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit CAN I/O Waterproof PRO 1.100.110.19 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for CAN I/O Waterproof PRO 110490 Plug package for CAN I/O Waterproof PRO 110421 Crimp contacts 2,8 mm / 1 - 2,5 mm² 109947 Crimp contacts 1,5 mm / 1,3 - 2 mm² 109949 Blanking plugs FCI Filler Plug 110268 Lens cap 111441 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 11 M2600 CAN PLC DESCRIPTION The M2600 CAN PLC module is main an efficient controller in the robust and compact metal housing for automotive applications. A broad pallet an inputs and outputs as well the flexibility to integrate additional modules opens a broad and universal application scope also in other industries. FUNCTION CANopen E/A-module CAN-bus at ISO11898 26 configurable inputs and outputs Max. 12 digital outputs Max. 6 digital inputs Max. 8 analog inputs 2 reference voltages Operating voltage 9 - 30 V DC Graphically programmable with MRS Developers Studio Housing dimensions 160 x 120 x 50 mm APPLICATION EXAMPLES Asphalt milling machines Forestry equipment Communal vehicles and additional components Winter vehicles and snowcats Tractors and attachments Harvesters TECHNICAL DATA Technical Data Value Operating voltage 9 - 30 V DC Operating temperature -40 °C to 85 °C Connector 42 pol. Tyco MT2 / JPT Protection class IP 65 Housing dimensions 160 x 120 x 50 mm E1 approval number 04 7279 Design may be subject of change – no guarantee for this information. DESIGN ORDER TABLE Type Ausführung Ordering Nr. 12 M2600 CAN PLC 2 x CAN High-Speed, RS232 1.260.300.00E M2600 CAN PLC 3 x CAN High-Speed 1.?260.?303.?00E M2600 CAN PLC 3 x CAN High-Speed with terminator 1.260.343.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit M2600 CAN PLC 1.100.110.09 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for M2600 108890 Plug package for M2600 108888 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 13 M2600 ECO CAN PLC DESCRIPTION The M2600 ECO CAN PLC is a main efficient controller in the compact V2A half shell. A broad pallet an inputs and outputs as well the flexibility to integrate additional modules opens a broad and universal application scope also in other industries. FUNCTION CANopen E/A-module CAN-bus at ISO11898 26 configurable inputs and outputs max. 12 digital outputs max. 6 digital inputs max. 8 analog inputs 4 sensor inputs, 2 reference voltages operating voltage 9 - 30 V DC graphically programmable with MRS Developers Studio APPLICATION EXAMPLES Asphalt milling machines Forestry equipment Communal vehicles and additional components Winter vehicles and snowcats Tractors and attachments Harvesters TECHNICAL DATA Technical Data Value Operating voltage 9 - 30 V DC Operating temperature -40 °C to 85 °C Connector 42 pol. Tyco MT2 / JPT Protection class IP 65 Housing dimensions 150 x 110 x 45 mm E1 approval number 04 7279 Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ausführung Ordering Nr. M2600 ECO CAN PLC 2 x CAN high speed, RS232 1.261.300.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Softwaretool MRS Developers Studio 1.100.100.09 Cable set for M2600 ECO CAN SPS 108890 Connector package 108888 14 Technical Data Ordering Nr. PCAN-USB Interface 105358 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 15 Micro PLC CAN DESCRIPTION The mirco PLC CAN is a very small controller for automotive applications. Thanks to its free configurability and programmability, many different applications can be implemented. Control and readout run via CAN-bus (ISO 11898-2). FUNCTION Freescale microcontroller with flash memory (option to write many times). There are available 2 analog and/or 1 analog input/1 digital output as well as 2 overload protected highside power outputs - alternatively 1 relay output. More complex applications can be realised in C code. The functions as well as the measurement values can be controlled and readout via CAN-bus. The programming is possible via the software MRS Developers Studio and graphically with CANgraph. By use of the powerful processor, the Micro PLC is CANopen- und SAE J1939-compliant. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES CANopen E/ A-module Seat contact check Pressure monitoring Special vehicles, machine automation Decentralized extension of function Door control TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Quiescent current less than 250 µA (stand by) Quiescent current 30 mA (idle) Cont. current relay 10 A / 15 A (no/ nc) Status output C Control lamp (max. 2W) Bus system CAN-bus (High-Speed) at ISO 11898-2 Protection class IP 53 E1 approval number 04 7362 Design may be subject of change – no guarantee for this information. DESIGN 16 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Micro PLC CAN 12 V A relais, two-way contact S2/ G2/ T 1.107.110.00E Micro PLC CAN 12 V B relais, two-way contact S3/ G2/ T 1.107.112.00E Micro PLC CAN 24 V A relais, two-way contact S2/ G2/ T 1.107.210.00E Micro PLC CAN 24 V B relais, two-way contact S3/ G2/ T 1.107.212.00E Micro PLC CAN 9-30 V A 2 x Highside driver S1/ G2/ T 1.107.310.001E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit Micro PLC CAN 1.100.110.22 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for Micro PLC CAN 109446 Flat pin socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 103064 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 17 Micro PLC CAN 4 I/O DESCRIPTION The micro PLC CAN is a very small controller for automotive applications. Thanks to its free configurability and programmability, many different applications can be implemented. Control and readout run via CAN-bus. FUNCTION CANopen E/A-module TECHNICAL DATA Technical Data Value Operating temperature -40 °C up to 85 °C Operating voltage 9 - 30 V DC Bus-system CAN-bus (high-speed) Protection class IP 53 E1 approval number 04 7199 Housing dimensions 30 x 30 x 40 mm Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ausführung Ordering Nr. Micro PLC CAN 4 I/ O S1/ G2/ T 1.111.311.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Developers Studio 1.100.100.09 Flat pin socket 1.017.002.00 Cable set Micro PLC CAN 109446 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 6,3 mm 1,0 mm² 102355 Faston terminal 2,8 mm 0,5-1,0 mm² 105292 Bracket for housing 1.017.080.00 PCAN-USB Interface 105358 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 18 Micro PLC CAN 4 ANA DESCRIPTION The Micro PLC CAN 4 ANA is a small controller for automotive applications. Thanks to its free configurability and programmability, many different applications can be implemented. FUNCTION 9 - 30 V DC 4 digial inputs, 2 of them usable as frequency inputs 4 analog inputs 0 - 10 V / 0 - 30 V or 0 - 20 mA 4 analog inputs 0 - 10 V / 0 - 30 V or 0 - 20 mA CAN high-speed, SAEJ1939 and CANopen APPLICATION EXAMPLES Sensor control Pressure monitoring Special vehicles, machine automation Decentralized extension of function TECHNICAL DATA Technical Data Value Operating temperature -40 °C up to 85 °C Operating voltage 9 - 30 V DC Bus-system CAN-bus (high-speed) Protection class IP 53 E1 approval number in preparation Housing dimensions 30 x 30 x 40 mm Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ordering Nr. Micro PLC CAN 4 ANA 1.112.300.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Developers Studio 1.100.100.09 Socket 1.017.002.00 Cable set 109446 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 6,3 mm 1,0 mm² 102355 19 Technical Data Ordering Nr. Faston terminal 2,8 mm 0,5-1,0 mm² 105292 Bracket for housing 1.017.080.00 PCAN-USB Interface 105358 Cable FLRY 2x0.50 mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 20 Micro PLC CAN LIN DESCRIPTION The Micro PLC CAN LIN is a very small controller for automotive applications. Thanks to its free configurability and programmability, many different applications can be implemented. Control and readour run via CAN-bus. APPLICATION EXAMPLES CANopen E/ A-module Seat contact check Pressure monitoring Special vehicles, machine automation Decentralized extension of function Door control TECHNICAL DATA Technical Data Value Operating temperature -40 °C - 85 °C Quiescent current less than 250 µA (stand by) Quiescent current 30 mA (idle) Continuous current 500 mA Bus system CAN-bus (high-speed) Bus system LIN Specification 2.1 Protection class IP 53 E1 approval number 04 7069 Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ordering Nr. Micro PLC CAN LIN 1.113.111.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for Micro PLC CAN 109446 Flat pin socket 1.017.002.00 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 2,8 mm 0,5-1,0 mm² 105292 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 21 CAN Relay Box DESCRIPTION The CAN relay box is a compact PLC with CAN-bus. Free graphical programming offers a wide range of applications in the automotive sector. FUNCTION 9 - 30 V DC 13 analog inputs 3 status LEds for CAN-bus and status Free programmable via MRS Developers Studio CANopen and SAEJ1939-able Housing dimensions: 95 x 85 x 35 mm CAN high-speed interface (optional CAN low-speed) 12 potential free relays for switching software (4 A continuous load) CAN wake-up selectable via Dip-switch CAN termination resistor selectable via Dip-switch Dip-switch for CAN ID change with the same software and multiple devices (2 dip-switch --> 4 addresses) APPLICATION EXAMPLES CANopen E/ A-module Towing vehicles Vehicle conversions Special vehicles DESIGN ORDER TABLE Technical Data Type Ordering Nr. CAN Relay Box HS high-speed 1.047.300.00E CAN Relay Box LS low-speed 1.047.310.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit CAN Relay Box HS 1.100.110.24 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set CAN Relay Box 109639 Connector package CAN Relay Box 109637 Cable FLRY 2x0.50mm² white/green SL20 113085 22 Technical Data Ordering Nr. Design may be subject of change – no guarantee for this information. 23 MRS Developers Studio DESCRIPTION By means of the graphic softwaretool MRS Developers Studio one can easily and quick create programs for MRS CAN products. The programms are downloaded by using the CAN bootloader. FUNCTION No knowledge of C-programming is necessary, only basic knowledge in digital technic are necessary for creating programs with the MRS Developers Studio© First step is to create a project and select the corresponding product (hardware) After defining the CAN IDs the necessary logic- and function-blocks can be selected with CANgraph© and connected After that analysis of the programm follows and if necessary modifications of the program Last step is to generate the software by push button By means of the USB- to CAN adapter via CAN-bus, the new programme is downloaded CANgraph© needs Eagle® light. The attached Eagle® light version is meant only for exercise and test purposes and must become licensed with the manufacturer. You receive the license under http://www.cadsoft.de/ 24 Micro PLC DESCRIPTION The Micro PLC is a very small controller for automotive applications. Thanks to its free configurability and programmability, many different applications can be implemented. FUNCTION MSP430 16 Bit microcontroller with flash memory (option to write many times) In the maximum version 1 analog, 3 digital inputs and 2 overload protected highside power outputs - alternatively 1 relay output - are available Low quiescent current of 250 µA By means of the programming station and Z-graph one can easily change standard functions and parameters More complex applications can be realised in C code Quick realization of customers specification Realization of special programs on demand Housing dimensions 30 x 30 x 40 mm For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Door control Pressure monitoring Seat contact check Control of vegetable oil switch-over TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Limiting continuous current 10/ 15 A (no/ nc) Semiconductor output each 60W with 12 V, 75W with 24V Status output C Control lamp (max. 2W) Protection class IP 53 Only Quiescent current 250 µA EMC 2006/ 96 EG e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. DESIGN 25 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Micro SPS / PLC 9-30V E1 EA1 1x442 A 3 digital 1 analog input, 1 S1/ G2/ T highside output 1.005.355.00E Micro SPS / PLC 9-30V EA1 2x442 A 3 digital 1 analog input, 2 S1/ G2/ T highside outputs 1.005.365.00E Micro SPS / PLC 9-30V EA1 2x442 C A 3 digital 1 analog input, 2 S1/ G2/ T highside outputs 1.005.371.00E Micro SPS / PLC 12V E3 A EA1 OR1 3 digital 1 analog input, 1 S2/ G2/ T relay output 1.005.151.00E Micro SPS / PLC 24V E3 A EA1 OR1 3 digital 1 analog input, 1 S2/ G2/ T relay output 1.005.251.00E Micro SPS / PLC 12V E3 A EA1 OR1 C 3 digital 1 analog input, 1 S2/ G2/ T relay output, 1 open collector output 1.005.150.00E Micro SPS / PLC 24V E3 A EA1 OR1 C 3 digital 1 analog input, 1 S2/ G2/ T relay output 1.005.250.00E Micro SPS / PLC 12V E3 B EA1 OR1 3 digital 1 analog input, 1 S3/ G2/ T relay output 1.005.154.00E Micro SPS / PLC 24V E3 B EA1 OR1 3 digital 1 analog input, 1 S3/ G2/ T relay output 1.005.254.00E Micro SPS / PLC 12V E3 C EA1 OR1 C 3 digital 1 analog input, 1 S4/ G2/ T relay output 1.005.153.00E Micro SPS / PLC 24V E3 C EA1 OR1 C 3 digital 1 analog input, 1 S4/ G2/ T relay output, 1 open collector output 1.005.253.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES 26 Housing Ordering Nr. Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 27 Controller M3 DESCRIPTION The controller M3 is a powerful and attractive priced controller. Besides the unprogrammed controller there are programmed versions available such as impulse relay, toggle relay, flasher unit and other functions on demand. The mentioned functions are available by default and have only to be configured and parameterized. It goes without saying that all functions also can be ordered directly. FUNCTION MSP430 16 Bit microcontroller with flash memory (write many times) 1 digital input and 1 digital output are available Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage Llow quiescent current of 1 mA By means of the programming station and Z-graph one can easily change standard functions and parameters More complex applications can be realised in C code Quick realization of customers specification Realization of special programs on demand Housing dimensions 30 x 30 x 40 mm For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Rear window heating Delayed switching off of lights Delayed switch-on of a load Fan switch-off delay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Protection class IP 53 E1 approval number 04 7282 Design may be subject of change – no guarantee for this information. DESIGN 28 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Controller M3 LB1 12V A S1/ G2/ E 1.036.101.00E Controller M3 LB1 24V A S1/ G2/ E 1.036.201.00E Controller M3 LB3 12V B S2/ G2/ Y 1.036.102.00E Controller M3 LB3 24V B S2/ G2/ Y 1.036.202.00E Controller M3 LB2 12V C S3/ G2/ E 1.036.103.00E Controller M3 LB2 24V C S3/ G2/ E 1.036.203.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm 103064 102355 2 105292 Design may be subject of change – no guarantee for this information. 29 Controller M4 DESCRIPTION The controller M4 is a powerful and attractive priced controller. Besides the unprogrammed controller there are programmed versions available such as impulse relay, toggle relay, flasher unit and other functions on demand. The mentioned functions are available by default and have only to be configured and parameterized. It goes without saying that all functions also can be ordered directly. APPLICATION EXAMPLES Construction machines Agricultural machinery Winter service Communal vehicles TECHNICAL DATA Technical Data Value Operating temperature -40 °C up to 85 °C Continuous current 10 / 15 A (NO/ NC) Protection class IP53 E1 approval number 04 7283 Housing dimensions 30 x 30 x 30 mm Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Type Ordering Nr. Controller M4 12 V Relay output 1.039.100.00E Controller M4 24 V Relay output 1.039.200.00E Controller M4 9 - 30 V 2 highside outputs 1.039.300.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 30 Controller M1 DESCRIPTION The controller M1 is a smaller, more powerful, better priced controller. Besides the time relay compact there are further compact relays available like impulse relay, toggle relay, flasher unit and other functions on demand. The mentioned functions are available by default and have only to be configured and parameterized. It goes without saying that all functions also can be ordered directly. FUNCTION MSP430 16 Bit microcontroller with flash memory (option to write many times) 1 digital input and 1 digital output are available Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage Low quiescent current of 1 mA By means of the programming station and z-graph one can easily change standard functions and parameters More complex applications can be realised in C code Quick realization of customer´s specification Realization of special programs on demand Housing dimensions 30 x 30 x 30 mm For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Rear window heating Delayed switching off of lights Fan switch-off delay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Protection class IP 53 E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. DESIGN 31 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Controller M1 compact OR1 12V A S1/ G1/ E 1.028.101.00E Controller M1 compact OR1 24V A S1/ G1/ E 1.028.201.00E Controller M1 compact OR1 12V B S2/ G1/ Y 1.028.102.00E Controller M1 compact OR1 24V B S2/ G1/ Y 1.028.202.00E Controller M1 compact OR1 12V C S3/ G1/ E 1.028.103.00E Controller M1 compact OR1 24V C S3/ G1/ E 1.028.203.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 32 Programming tool MRS Realizer I DESCRIPTION The tool can be used for the easy and quick programming respectively of the Micro PLC. The programming is done via the relay contacts, thus no mechanical intervention is necessary. FUNCTION The software MRS Realizer I and Z-graph is part of the programming station. By means of the MRS Realizer one can programm basic functions like voltage monitoring relay or time relay. The limits and times can easily be changed. Special PLC programs can be quickly programmed with the graphical programming tool Z-graph. Complex programms can be written in C-Code. On demand we program your control function. ORDER TABLE Technical Data Ordering Nr. Programming Tool MRS Realizer I 1.100.000.01 Design may be subject of change – no guarantee for this information. 33 Z-graph DESCRIPTION MRS Electronic offers with Z-graph an easy and cost-efficient graphic programming tool. By means of Z-graph one can easily program the Micro PLC without deeper programming knowledge. One can quickly realize different applications without the knowledge of C-programming, just by graphical creation of a function plan (FUP). FUNCTION Z-graph© is part of the programming station Z-graph© uses the circuit diagram module of Eagle® in order to create the function plan (FUP). With the existing library functions one can easily generate the custom application. Very easy to learn. No profound programming knowledge is necessary Low development costs. Low costs since it is part of the MRS Realizer I Z-graph© needs Eagle® light. The attached Eagle® light version is meant only for exercise and test purposes and must become licensed with the manufacturer. You receive the license under http://www.cadsoft.de/ 34 CAN Gateway Module DESCRIPTION The compact vehicle suitable CAN gateway module with PLC function is to easily extend existing vehicle functions with low wiring costs. It is freely programmable and equipped with three CAN interfaces. APPLICATION EXAMPLES CANopen E/ A-module Vehicle customizings, which data from the CAN bus receiveor activate functions via CAN Additional control points in vehicles (e.g. Driving Schools) Vehicle customizings for construction equipment Transfer of vehicle secondary functions (e.g. wheelchairs) TECHNICAL DATA Technical Data Value Operating temperature - 40 °C up to 85 °C Operating voltage 12 V DC Inputs 20 analog inputs Outputs 4 digital outputs / 6 relay outputs CAN-bus CAN high- and low-speed, CANopen able Housing dimensions 85 x 95 x 35 mm e1 approval number 03 6588 Design may be subject of change – no guarantee for this information. DESIGN ORDER TABLE Technical Data Ausführung Ordering Nr. CAN gateway module HS 3 x high-speed 1.042.100.00E CAN gateway module LS 2 x low-speed, 1 x high-speed 1.042.110.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter Kit - CAN Gateway module 1.100.110.17 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for CAN Gateway module 109639 35 Technical Data Ordering Nr. Plug package for CAN Gateway module 109637 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 36 Universal Gateway DESCRIPTION The Universal Gateway of MRS makes data exchange possible between different bus environments. The open and flexible design cut to automotive applications permits a fast adjustment on customized requirements even with smaller numbers of items. FUNCTION basic configuration with 2 x CAN interfaces, 1 x RS485, 1 x RS232 optional up to 5 x CAN interfaces universal configuration with 3 additional boards e.g. USB, Ethernet, data logger, digital Inputs and Outputs, special performances etc. graphically programmable with MRS Developers Studio package dimensions 95 x 65 x 35 mm APPLICATION EXAMPLES CANopen E/ A-module Transmission of Modbus (RS485) on CAN and in reverse Freely programmable data logger with real-time clock and large storage volume Data exchange between different bus systems e.g. CAN - USB Uncoupling of CAN bus systems with different Baud rate or different functions/ hierarchies DESIGN ORDER TABLE Technical Data Ordering Nr. Universal Gateway with slots 1.032.301.00E Universal Gateway without slots 1.032.302.00E Universal Gateway with slots and with SD-card 1.032.303.00E Universal Gateway without slots and with SD-card 1.032.304.00E Universal Gateway without slots HS + LS 1.032.305.00E Universal Gateway without slots with SD-card HS + LS 1.032.306.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter Kit - Universal Gateway without slots 1.100.110.14 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for Universal Gateway 109260 37 Technical Data Ordering Nr. Plug package for universal gateway 109203 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 38 Universal Gateway 5x CAN DESCRIPTION The Universal Gateway of MRS makes data exchange possible between CAN bussystems. The open and flexible design cut to automotive applications permits a fast adjustment on customized requirements even with smaller numbers of items. FUNCTION basic configuration with 5 x CAN interfaces optional up to 5 x CAN interfaces as assembly High- / Low-Speed graphically programmable with MRS Developers Studio package dimensions 95 x 65 x 35 mm APPLICATION EXAMPLES CANopen E/ A-module Data exchange between CAN bus systems Uncoupling of CAN bus systems with different Baud rate or different functions/ hierarchies ORDER TABLE Technical Data Ordering Nr. Universal Gateway 5x CAN 1.057.300.00E Universal Gateway 5x CAN FREQ-IN 1.057.300.01E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Developers Studio 1.?100.?100.?09 PCAN-USB Interface 105358 Cable set for Universal Gateway 5x CAN 109260 Plug package for Universal Gateway 5x CAN 109203 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 39 Micro Gateway DESCRIPTION The Micro Gateway is the smallest gateway for automotive applications. Due to its small size and easy installation it offers a wide variety of applications. FUNCTION Filter functions for CAN messages CAN high-speed 11898-5 according to CAN2.0A or CAN2.0B The module is programmable via CAN-bus (CAN-bootloader) CAN to LIN gateway Graphical programming with MRS Developers Studio APPLICATION EXAMPLES CANopen E/ A-module Data exchange between vehicle- and diagnosticbus Cross-linking of LIN and CAN-bus Decoupling of CAN-bus systems with different baud rate or different functions / hierarchies TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage CAN-CAN 9 - 30 V DC Operating voltage CAN-CAN-LIN 12 V DC Input 1 analog input CAN-bus CAN-high-speed LIN-Bus LIN Specification 2.1 Housing dimensions 30 x 30 x 50 mm E1 approval number 04 7139 Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Micro Gateway CAN-CAN-LIN A 2 x CAN-bus, LIN S1/ G3/ T 1.114.110.00E Micro Gateway CAN-CAN B 2 x CAN-bus S2/ G3/ T 1.114.300.00E Micro Gateway CAN-CAN 2x120R B 2 x CAN-Bus & 2x120R S2/ G3/ T 1.114.300.0011E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Developers Studio 1.100.100.09 Socket 1.017.002.00 40 Technical Data Ordering Nr. Cable set Micro Gateway 109446 PCAN-USB Interface 105358 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 6,3 mm 1,0 mm² 102355 Faston terminal 2,8 mm 0,5-1,0 mm² 105292 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 41 CAN/RS485 Gateway DESCRIPTION The compact automotive CAN/RS485 module serves for the extension of existing CAN controllers, but can also used as standalone PLC controller. Graphic programming with the Softwaretool CANgraph and suitable Flash program tool or programming with a C-development system. FUNCTION Freescale HCS08 processor with flash-technology (Option to write many times). CAN high- or low-speed or RS485 bus can be used to communicate with further systems and offer an easy integration in existing systems. 6 digital outputs and/or analog inputs (programmable). 2 digital outputs and/or digital inputs (programmable). 6 analog inputs additionally. Protected from polarity and electrical transient ones. Outputs: Power-Highside-Driver, overload-proof, with digital status. By use of the powerful processor, the module is CANopenund SAE J1939-compliant. APPLICATION EXAMPLES CANopen E/ A-module Output expansion Input expansion Control of operating unit Light control Inquiry of sensors Independent PLC controller TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V DC Connector 22pol. Molex Mini Fit Junior Protection class IP 53 Compact housing 60 x 60 x 30 mm e1 approval number 03 5385 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 42 ORDER TABLE Technical Data Ausführung Housing CAN/ RS485 Gateway 6 analog inputs, 8 I/ Os (RS485) G7 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit CAN RS485 Gateway 1.100.110.01 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for CAN RS485 Gateway 106817 Plug package for CAN RS485 Gateway 106940 Spout for cable set 102892 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 43 Ordering Nr. 1.033.320.00E PROP CAN DESCRIPTION The proportional valve controller with CAN-bus serves to regulate the flow rates of a proportional valve. It can be used for many hydraulic applications. CAN high- or low-speed (alternatively RS485) Bus can be used to communicate with further systems and offer an easy integration in existing systems. FUNCTION The micro controller's current control is direct proportional to the set-point 0 - 10 Volt or 0 - 20 mA. Contolling and read/write of all values by CAN Bus possible. Fluctuations in supply voltage and temperature are compensated. Thereby a constant flow rate is ensured. In order to avoid a determining of the valve, a Dither frequency (overlaid rectangle with smaller frequency) can be adjusted. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES CANopen E/ A-module TECHNICAL DATA Technical Data Value Operating voltage 9 - 30 V DC Quiescent current less than 250 µA (stand by), 30 mA (idle) Continuous current max. 3 A Protection class IP 53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Ausführung Proportional amplifier CAN 9-30 Desired voltage / Current with 44 Housing Ordering Nr. S1/ G2/ E 1.108.310.00E V CAN-bus Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit - Prop CAN 1.100.110.03 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for Prop CAN 109446 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm 103064 102355 2 Cable FLRY 2x0.50mm² white/green SL20 105292 113085 Design may be subject of change – no guarantee for this information. 45 Motorcontroller 5A CAN DESCRIPTION The motor controller 5A CAN is a micro-controller steered modul e.g. for automotives applications. Free configuring and programmability make the realization possible of most different applications. The motor controller 5A CAN module is conceived very compact and can be used thus variously. FUNCTION 9 - 30 V DC load current 5 A (short 5 A / duration 3 A) short-circuit-proof integrable performance for motor control CAN-BUS at ISO11898 reversion of rotation, start -and stopramp arbitrary current limiting via CAN-BUS free adjustable 3 analog inputs, free programmable protection class IP53 APPLICATION EXAMPLES CANopen E/ A-module Vehicle modifications Fan control Flap control Mirror controller TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V DC Protection class IP53 Housing dimensions 30 x 30 x 40 mm E1 approval number 04 6879 Design may be subject of change – no guarantee for this information. DESIGN ORDER TABLE Type Ausführung Ordering Nr. Motorcontroller 5A CAN Power on Pin 15 1.037.300.00E 46 Type Ausführung Ordering Nr. Motorcontroller 5A CAN Power on Pin 30 1.037.300.10E Motorcontroller 5A CAN Power on Pin 30 & frequency-inputs on X,C 1.037.300.11E Motorcontroller 5A CAN Power on Pin 15 & frequency-inputs on X,C 1.037.300.01E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit motorcontroller 5A CAN 1.100.110.08 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 cable set for motorcontroller 5A CAN 109446 Flat pin socket 1.017.002.00 Faston terminal 6,3 mm 1,5-2,5mm² 103064 Faston terminal 6,3 mm 1mm² 102355 Faston terminal 2,8 mm 0,5-1,0 mm² 105292 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 47 Motorcontroller 10A CAN DESCRIPTION The Motorcontroller 10 A CAN is a microcontroller-steered module e.g. for automotive applications. Free configuring and programmability make the realization possible of most different applications. The Motorcontroller 10 A CAN is very compact and can be used thus variously. FUNCTION 9 - 30 V DC 3 analog inputs or digital inputs 1 fullbridge-motoroutput CAN high- / low-speed CANopen and SAEJ1939-able APPLICATION EXAMPLES CANopen E/ A-module Vehicle modifications Fan control Flap control Mirror controller TECHNICAL DATA Technical Data Value Operating temperature -40 °C to 85 °C Operating voltage 9 - 30 V DC Protection class IP 53 Housing dimensions 30 x 30 x 40 mm E1 approval number 04 7515 Design may be subject of change – no guarantee for this information. ORDER TABLE Technical Data Ausführung Ordering Nr. Motorcontroller 10 AN CAN with poti 1.117.300.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programmin tool MRS Developers Studio 1.100.100.09 Socket 1.017.002.00 Cable set 109446 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 6,3 mm 1,0 mm² 102355 48 Technical Data Ordering Nr. Faston terminal 2,8 mm 0,5-1,0 mm² 105292 PCAN-USB Interface 105358 Cable FLRY 2x0.50 mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 49 6-fold PROP CAN DESCRIPTION The economical and automotive suited 6-fold proportional amplifier serves for the flow rate regulation of proportional valves. By the use of a micro controller the current and ditherfrequency parameter can be adjusted freely. FUNCTION 9 - 30 V DC 1 digital output 8 analog inputs CAN High Speed; SAEJ1939; CANopen able 6 PWM outputs with 2,5 A (only 3 outputs at the same time usable) current control housing dimensions 95 x 65 x 35 mm APPLICATION EXAMPLES CANopen E/ A-module Agricultural machinery Industry/ equipment construction Public utilities vehicles Special vehicles Mechanical engineering Construction machines ORDER TABLE Type Ordering Nr. 6-fold Prop CAN 1.109.300.00E 6-fold Prop CAN - 2 x freq.-input 1.109.300.01E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Starter-Kit - 6-fold Prop CAN 1.100.110.15 Programming tool MRS Developers Studio 1.100.100.09 PCAN-USB Interface 105358 Cable set for 6-fold Prop CAN 109291 Plug package for 6-fold Prop CAN 109383 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 50 Proportional amplifier DESCRIPTION The proportional valve controller serves to regulate the flow rates of a proportional valve. It can be used for many hydraulic applications. FUNCTION The micro controller's current control is direct proportional to the set-point 0 - 10 Volt or 0 - 20 mA. Thus fluctuations in supply voltage and temperature are compensated. Thereby a constant flow rate is ensured. In order to avoid a determining of the valve, a Ditherfrequenz (overlaid rectangle with smaller frequency) can be adjusted. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Construction machines Agriculture machines Communal vehicles Special vehicles Machine automation Industrial applications TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Operating voltage 9-30 V Quiescent current 250 µA continuous current max. 3 A Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 51 ORDER TABLE Technical Data Housing Ordering Nr. Proportional amplifier 9-30V Vin Desired voltage without poti Ausführung S1/ G2/ E 1.030.310.00E Proportional amplifier 9-30V Iin S1/ G2/ E 1.030.320.00E Proportional amplifier 9-30V Vin Desired voltage with poti + Poti S1/ G2/ E 1.030.311.00E Proportional amplifier 9-30V Iin + Poti S1/ G2/ E 1.030.321.00E Desired current without poti Desired current with poti Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm bracket for housing 103064 102355 2 105292 1.017.080.00 Design may be subject of change – no guarantee for this information. 52 Reference voltage-DC/DC converter DESCRIPTION Sensors are supplied by the reference voltage Vref / Vout at the output. FUNCTION If at terminal 30 an input supply of 9 - 30 V applied, it is clear to terminal Vref the reference voltage of 5 V or 12 V. TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Input voltage 9 - 30 V -- 5 V Vref Input voltage 15 - 30 V -- 12 V Vref Output voltage 5 V / 12 V Current limit 500 mA Protection class IP53 E1 approval number 04 7308 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE 53 Technical Data Type Housing Ordering Nr. Reference voltage 5 V A S1/ G1/ S 1.038.300.05E Reference voltage 12 V A S1/ G1/ S 1.038.300.12E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Design may be subject of change – no guarantee for this information. 54 Referenzspannung-DC/DC converter 2A DESCRIPTION Sensors are supplied by the reference voltage Vref / Vout at the output. FUNCTION If at terminal 30 an input supply of 9 - 30 V applied, it is clear to terminal Vref the reference voltage of 5 V / 10 V or 5 V / 17 V. ORDER TABLE Technical Data Ordering Nr. DC/ DC 2A with 10 V / 5 V Ref. 1.044.300.00E DC/ DC 2A with 17 V / 5 V Ref. 1.044.300.17E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin socket 1.017.002.00 Design may be subject of change – no guarantee for this information. 55 Touch Panel DESCRIPTION The Touch Panel is a user-friendly keybord specially designed for use in commercial vehicles. The Touch Panel has a glass front window and is therefore resistant to liquids, oils, as well as stain-resistant and shock-resistant. The LED backlight allows a free choice of color for the light-symbols. FUNCTION CAN high speed interface Inputs: up to 10 capacitive buttons Outputs: signal transmitter as acoustic feedback Housing example: 155 x 96 x 24 mm Individual design and size of the display area by customer request CAN wake-up / CAN terminating resistor selectable via dip-switch To connect only 4 cables are required (KL30, KL31, CAN-H, CAN-L) Optional front plate version in Makrolon APPLICATION EXAMPLES CANopen E/ A-module Towing and recovery vehicles Snow mobiles and snow groomers Emergency vehicles Agricultural vehicles and technology TECHNICAL DATA Technical Data Value Operating voltage 9 - 30 V DC Operating temperature -40 °C to 85 °C Connector Molex MicroFit 8 pol. Protection class IP 54 Housing dimensions 155 x 96 x 24,2 mm E1 approval number 04 7140 Design may be subject of change – no guarantee for this information. DESIGN ORDER TABLE Technical Data Ordering Nr. Touch Panel 1.046.300.00 Design may be subject of change – no guarantee for this information. 56 ACCESSOIRES Technical Data Ordering Nr. Connector Package for Touch Panel 112321 Cable set Touch Panel 113131 Cable FLRY 2x0.50mm² white/green SL20 113085 Design may be subject of change – no guarantee for this information. 57 Time relay switch-on delay DESCRIPTION Timer relay switch-on delay M3 can be used to switch on a consumer time delayed . Please specify the reqested switch-on delay time in your order . FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon as signal voltage is applied to terminal 15 the relay switches on after the given delay time has elapsed. If signal voltage is removed from terminal 15 the relay switches-off immediatly. Diagram S2 and S3: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Compressor Air conditioning systems Switch on-delayed engines TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C continuous current 30 A max. switching volt. 75 VDC max. switching curr. 60 A max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 IP65 on customers request Delay time custom defined E1 approval number 04 7282 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 58 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M3 switch-on 12V A S1/ G2/ E 1.003.194.00E Time-relay M3 switch-on 24V A S1/ G2/ E 1.003.294.00E Time-relay M3 switch-on 12V B S2/ G2/ Y 1.003.195.00E Time-relay M3 switch-on 24V B S2/ G2/ Y 1.003.295.00E Time-relay M3 switch-on 12V C S3/ G2/ E 1.003.193.00E Time-relay M3 switch-on 24V C S3/ G2/ E 1.003.293.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm 103064 102355 2 105292 Design may be subject of change – no guarantee for this information. 59 Time relay switch-on delay compact DESCRIPTION Timer relay switch-on delay compact can be used to switch on a consumer time delayed . Please specify the reqested switch-on delay time in your order . FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon as signal voltage is applied to terminal 15 the relay switches on after the given delay time has elapsed. If signal voltage is removed from terminal 15 the relay switches-off immediatly. Diagram S2 and S3: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Compressor Air conditioning systems Switch on-delayed engines TECHNICAL DATA Technical Data Value Housing dimension 30 x 30 x 30 mm Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Delay time custom defined Ingress protection IP53 IP65 on customers request E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 60 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M1 switch-on 12V A S1/ G1/ E 1.003.184.00E Time-relay M1 switch-on 24V A S1/ G1/ E 1.003.284.00E Time-relay M1 switch-on 12V B S2/ G1/ Y 1.003.185.00E Time-relay M1 switch-on 24V B S2/ G1/ Y 1.003.285.00E Time-relay M1 switch-on 12V C S3/ G1/ E 1.003.183.00E Time-relay M1 switch-on 24V C S3/ G1/ E 1.003.283.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 61 Time relay switch on delay adjustable DESCRIPTION Time relay switch-on delay adjustable offer a time adjustment via poti within the given time period. One can choose betweeen 5 time spans (see table below). Different time periods can be defined on demand. Please specify the required switch-on delay time (time period) in your order. FUNCTION All diagrams: The supply voltage is applied to terminal 30/87z. If the signal voltage is applied to terminal 15 the relay switches after the delay time has elapsed. If voltage is removed the relay switches off immediatly. Diagram S2:The contacts are seperated from the trigger, therefore they can be used in combinations. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Air conditioning switch-on delay Compressors switch-on delay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 10A/ 15 A (no/ nc) Time tolerance +/ - 1 % Ingress protection IP53 (with poti cover) Quiescent current 250 µA e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 62 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay adjust. switch-on 12V A S1/ G2/ E 1.022.112.XXE Time-relay adjust. switch-on 24V A S1/ G2/ E 1.022.212.XXE Time-relay adjust. switch-on 12V C S2/ G2/ E 1.022.110.XXE Time-relay adjust. switch-on 24V C S2/ G2/ E 1.022.210.XXE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. FUNCTION TABLE Time interval Time indication XX = 01: 0.5 - 5 sec. XX = 02: 1 - 30 sec. XX = 03: 0.5 - 60 sec. 63 XX = 04: 30 - 900 sec. XX = 05: 0,5 - 4000 sec. Design may be subject of change – no guarantee for this information. 64 Time relay switch-off delay DESCRIPTION This relay can be used to switch-off a consumers time delayed . Please specify the required switch-off delay time in your order. FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon as signal voltage is applied to terminal 15 the relay switches on immediatly. If signal voltage is removed from terminal 15 the relay switches off after the defined delay time. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. Diagram S3: Due to the diode the relay needs no quiescent current after it has switched-off. Variant S3 only 10/15A (O/C) For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Defrost Delayed switching off of lights Follow-up control TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A (S3 = 10/ 15 A) Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on current 100 A Quiescent current 1 mA Delay time custom defined Ingress protection IP53 IP65 on customers request S1+S2: E1 approval number 04 7282 S3: e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 65 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M3 switch-off 12V A S1/ G2/ E 1.003.191.00E Time-relay M3 switch-off 24V A S1/ G2/ E 1.003.291.00E Time-relay M3 switch-off 12V B S2/ G2/ Y 1.003.192.00E Time-relay M3 switch-off 24V B S2/ G2/ Y 1.003.292.00E Time-relay switch-off 12V C S3/ G2/ E 1.003.120.00E Time-relay switch-off 24V C S3/ G2/ E 1.003.220.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 66 Time relay switch-off delay compact DESCRIPTION This time relay compact can be used to switch-off a consumers time delayed . Please specify the required switch-off delay time in your order. FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon as signal voltage is applied to terminal 15 the relay switches on immediatly. If signal voltage is removed from terminal 15 the relay switches off after the defined delay time. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Defrost Delayed switching off of lights TECHNICAL DATA Technical Data Value Housing dimension 30 x 30 x 30 mm Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on current 100 A Quiescent current 1 mA Delay time custom defined Ingress protection IP53 IP65 on customers request E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 67 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M1 switch-off 12V A S1/ G1/ E 1.003.181.00E Time-relay M1 switch-off 24V A S1/ G1/ E 1.003.281.00E Time-relay M1 switch-off 12V B S2/ G1/ Y 1.003.182.00E Time-relay M1 switch-off 24V B S2/ G1/ Y 1.003.282.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 68 Time relay switch-off delay adjustable DESCRIPTION Time relay switch-off delay adjustable offer a time adjustment via poti within the defined time period. One can choose betweeen 5 time spans (see table below). Different time periods can be defined on demand. Please specify the required switch-off delay time (time period) in your order. FUNCTION All diagrams: The supply voltage is applied to terminal 30/87z. If the signal voltage is applied to terminal 15, the relay switches on. Is signal removed the relay switches off after the delay time has elapsed. Diagram S3: Due to the integrated decoupling diodes, the relay needs no quiescent current after it has dropped out. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Fan switch-off delay Lights switch-off delay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 10 A/ 15 A (Ö/ S) Time tolerance +/ - 1 % Ingress protection IP53 (with poti cover) Quiescent current 250 µA e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 69 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay adjust. switch-off 12V A S1/ G2/ E 1.022.113.XXE Time-relay adjust. switch-off 24V A S1/ G2/ E 1.022.213.XXE Time-relay adjust. switch-off 12V B S2/ G2/ Y 1.022.116.XXE Time-relay adjust. switch-off 24V B S2/ G2/ Y 1.022.216.XXE Time-relay adjust. switch-off 12V D S3/ G2/ E 1.022.111.XXE Time-relay adjust. switch-off 24V D S3/ G2/ E 1.022.211.XXE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm Bracket for housing 103064 102355 2 105292 1.017.080.00 Design may be subject of change – no guarantee for this information. FUNCTION TABLE Time interval Time indication 70 XX = 01: 0.5 -5 sec. XX = 02: 1 - 30 sec. XX = 03: 0.5 - 60 sec. XX = 04: 30 - 900 sec. XX = 05: 0,5 - 4000 sec. Design may be subject of change – no guarantee for this information. 71 Time relay switch-on and off delay DESCRIPTION Time relay switch-on and off delay M3 can be used to switch on and off a consumer time delayed . Please specify the required switch-on and -off delay time in your order. FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon a signal voltage is applied to terminal 15 the relay switches on after the given delay time has elapsed. Is the signal voltage removed from terminal 15 the relay switches off after the defined delay time. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Timer Fan switch-off delay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A (S3 = 10/ 15 A) Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 IP65 on customers request Delay time custom defined S1+S2: E1 approval number 04 7282 S3: e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 72 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M3 switch-on and off A 12V S1/ G2/ E 1.003.196.00E Time-relay M3 switch-on and off A 24V S1/ G2/ E 1.003.296.00E Time-relay M3 switch-on and off B 12V S2/ G2/ Y 1.003.197.00E Time-relay M3 switch-on and off B 24V S2/ G2/ Y 1.003.297.00E Time-relay switch-on and off 12V C S3/ G2/ E 1.003.190.00E Time-relay switch-on and off 24V C S3/ G2/ E 1.003.290.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm Bracket for housing 2 105292 1.017.080.00 Design may be subject of change – no guarantee for this information. 73 Time relay switch-on and off delay compact DESCRIPTION Time relay switch-on and off delay compact can be used to switch on and off a consumer time delayed . Please specify the required switch-on and -off delay time in your order. FUNCTION All diagrams: To terminal 30/87z supply voltage is applied. As soon a signal voltage is applied to terminal 15 the relay switches on after the given delay time has elapsed. Is the signal voltage removed from terminal 15 the relay switches off after the defined delay time. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Timer Fan switch-off delay TECHNICAL DATA Technical Data Value Housing dimension 30 x 30 x 30 mm Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Delay time custom defined Ingress protection IP53 IP65 on customers request E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 74 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Time-relay M1 switch-on and off A 12V S1/ G1/ E 1.003.186.00E Time-relay M1 switch-on and off A 24V S1/ G1/ E 1.003.286.00E Time-relay M1 switch-on and off B 12V S2/ G1/ Y 1.003.187.00E Time-relay M1 switch-on and off B 24V S2/ G1/ Y 1.003.287.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 75 Impulse relay DESCRIPTION Impulse relays M3 are used to switch on and off consumer for defined time period. Please specify the required pulse length in your order . FUNCTION Diagram S1 and S2: To terminal 30, the supply voltage is applied. If a control voltage is applied to terminal 15, the relay switches-on for the given time period and switches-off afterwards. The duration of the input impulse has no impact on output impulse duration. Diagram S3: Supply voltage is applied to terminal 87z. If a control voltage is applied to terminal 15, the relay switches-on for the given time period and switches-off afterwards. Is control voltage taken away before, the relay switches-off directly. The duration of the input impulse has no impact on output impulse duration. Diagram S2 and S3: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Preheat controller TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 IP65 on customers request Impulse time custom defined E1 approval number 04 7282 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 76 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Impulse relay M3 12V A S1/ G2/ E 1.002.191.00E Impulse relay M3 24V A S1/ G2/ E 1.002.291.00E Impulse relay M3 12V B S2/ G2/ Y 1.002.192.00E Impulse relay M3 24V B S2/ G2/ Y 1.002.292.00E Impulse relay M3 12V C S3/ G2/ E 1.002.193.00E Impulse relay M3 24V C S3/ G2/ E 1.002.293.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 77 Impulse relay compact DESCRIPTION Impulse relays compact are used to switch on and off consumer for defined time period. Please specify the required pulse length in your order. FUNCTION Diagram S1 and S2: To terminal 30, the supply voltage is applied. If a control voltage is applied to terminal 15, the relay switches-on for the given time period and switches-off afterwards. The duration of the input impulse has no impact on output impulse duration. Diagram S3: Supply voltage is applied to terminal 87z. If a control voltage is applied to terminal 15, the relay switches-on for the given time period and switches-off afterwards. Is control voltage taken away before, the relay switches-off directly. The duration of the input impulse has no impact on output impulse duration. Diagram S2 and S3: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 and S3 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Preheat controller windshield wiper TECHNICAL DATA Technical Data Value Housing dimension 30 x 30 x 30 mm Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 Impulse time custom defined IP65 on customers request E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 78 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Impulse relay M1 12V A S1/ G1/ E 1.002.181.00E Impulse relay M1 24V A S1/ G1/ E 1.002.281.00E Impulse relay M1 12V B S2/ G1/ Y 1.002.182.00E Impulse relay M1 24V B S2/ G1/ Y 1.002.282.00E Impulse relay M1 12V C S3/ G1/ E 1.002.183.00E Impulse relay M1 24V C S3/ G1/ E 1.002.283.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 79 Impulse relay adjustable DESCRIPTION Impulse relay are applied to switch on and off consumer for defined time period. One can choose betweeen 5 time spans (see table below). Different time periods we offer on demand. Please specify the required pulse length in your order. FUNCTION Diagram S1:To terminal 30 supply voltage is applied. If signal voltage is applied to terminal 15 shortly or permanent, the relay switches for the given time period and switches off afterwards. Diagram S2: Supply voltage is applied at terminal 87z. If signal voltage is applied at terminal 15 shortly or permanent the relay switches for the given time period and switches off afterwards. Is control voltage taken away before, the relay switches-off directly.The contacts are seperated from the trigger, therefore they can be used in combinations. All diagrams: The duration of the input signal has no impact on output pulse duration. The exact pulse length can be adjusted via Poti within the given time period. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Preheat time TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Impulse time see time intervalls Continuous current 10A/ 15 A (no/ nc) Time tolerance +/ - 1 % Ingress protection IP53 (with poti cover) Quiescent current 250 µA e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 80 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Housing Ordering Nr. Impulse relay adjust. 12V A S1/ G2/ E 1.022.115.XXE Impulse relay adjust. 24V A S1/ G2/ E 1.022.215.XXE Impulse relay adjust. 12V C S2/ G2/ E 1.022.114.XXE Impulse relay adjust. 24V C S2/ G2/ E 1.022.214.XXE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. FUNCTION TABLE Time interval Time indication XX = 01: 0.5 - 5 sec. XX = 02: 1 - 30 sec. XX = 03: 0.5 - 60 sec. XX = 04: 30 - 900 sec. XX = 05: 0,5 - 4000 sec. Design may be subject of change – no guarantee for this information. 81 Toggle relay DESCRIPTION The application range of toggle relay M3 is the switch-on and -off of loads by impulse operation. FUNCTION Diagram S1: Using toggle relay a load can be switched on and off via push button. If a positive / negative impulse is applied at terminal 15, the relay switches its state (on or off). Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Lighting TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Continuous current 30 A (S3 = 10A/ 15 A) Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 IP65 on customers request E1 approval number 04 7282 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 82 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Toggle relay M3 12V 30A A positive edge triggered S1/ G2/ E 1.001.191.00E Toggle relay M3 24V 30A A positive edge triggered S1/ G2/ E 1.001.291.00E Toggle relay M3 12V 30A A negative edge triggered S1/ G2/ E 1.001.192.00E Toggle relay M3 24V 30A A negative edge triggered S1/ G2/ E 1.001.292.00E Toggle relay M3 12V 30A B positive edge triggered S2/ G2/ Y 1.001.193.00E Toggle relay M3 24V 30A B positive edge triggered S2/ G2/ Y 1.001.293.00E Toggle relay M3 12V 30A B negative edge triggered S2/ G2/ Y 1.001.194.00E Toggle relay M3 24V 30A B negative edge triggered S2/ G2/ Y 1.001.294.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm 103064 102355 2 105292 Design may be subject of change – no guarantee for this information. 83 Toggle relay 2 DESCRIPTION The application range of toggle relay is the switch-on and -off of loads by impulse operation. FUNCTION Using toggle relay a load can be switched on and off via push button. If a positive / negative impulse is applied at terminal 15, the relay switches its state (on or off). For different housing please see in the chapter housing and baseplates. Toggle relay 2 are mechanical and therefore not programmable. TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Max switching curr. off 30 A/ 60 A (no/ nc) Max switching curr. on less than 3 sec. 30 A/ 100 A (no/ nc) Continuous current 10 A/ 20 A (no/ nc) Ingress protection IP53 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 84 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Toggle relay 12V 20/ 10A A positive edge triggered G2/ E 1.001.100.00E Toggle relay 24V 20/ 10A A positive edge triggered G2/ E 1.001.200.00E Toggle relay 12V 20/ 10A A negative edge triggered G2/ E 1.001.102.00E Toggle relay 24V 20/ 10A A negative edge triggered G2/ E 1.001.202.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm² 103064 Faston terminal 6,3 mm 1mm² 102355 Faston terminal 2,8mm 0,5-1,0mm² 105292 Design may be subject of change – no guarantee for this information. 85 Toggle relay compact DESCRIPTION The application range of toggle relay compact is the switch-on and -off of loads by impulse operation. FUNCTION Diagram S1: Using toggle relay compact a load can be switched on and off via push button. If a positive / negative impulse is applied at terminal 15, the relay switches its state (on or off). Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. TECHNICAL DATA Technical Data Value housing dimension 30 x 30 x 30 mm operating temp. -40 °C to 85 °C continuous current 30 A max. switching volt. 75 VDC max. switching curr. 60 A max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 86 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Toggle relay M1 12V 30A A positive edge triggered S1/ G1/ E 1.001.181.00E Toggle relay M1 24V 30A A positive edge triggered S1/ G1/ E 1.001.281.00E Toggle relay M1 12V 30A A negative edge triggered S1/ G1/ E 1.001.182.00E Toggle relay M1 24V 30A A negative edge triggered S1/ G1/ E 1.001.282.00E Toggle relay M1 12V 30A B positive edge triggered S2/ G1/ Y 1.001.183.00E Toggle relay M1 24V 30A B positive edge triggered S2/ G1/ Y 1.001.283.00E Toggle relay M1 12V 30A B negative edge triggered S2/ G1/ Y 1.001.184.00E Toggle relay M1 24V 30A B negative edge triggered S2/ G1/ Y 1.001.284.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 87 Toggle relay time limited DESCRIPTION The application range of toggle time-delayed M3 is the switch-on and -off of loads by impulse operation with a limited on-time. Please specify the required on-time in your order. FUNCTION Diagram S1: Using toggle relay a load can be switched on and off via push button. If a positive / negative impulse is applied at terminal 15, the relay switches its state (on or off). The on-time is limited. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Rear window heater with time delayed reset TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C continuous current 30 A max. switching volt. 75 VDC max. switching curr. 60 A max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 IP65 on customers request E1 approval number 04 7282 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 88 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Toggle relay M3 12V time-limited A positive edge triggered S1/ G2/ E 1.001.191.XXE Toggle relay M3 24V time-limited A positive edge triggered S1/ G2/ E 1.001.291.XXE Toggle relay M3 12V time-limited A negative edge triggered S1/ G2/ E 1.001.192.XXE Toggle relay M3 24V time-limited A negative edge triggered S1/ G2/ E 1.001.292.XXE Toggle relay M3 12V time-limited B positive edge triggered S2/ G2/ Y 1.001.193.XXE Toggle relay M3 24V time-limited B positive edge triggered S2/ G2/ Y 1.001.293.XXE Toggle relay M3 12V time-limited B negative edge triggered S2/ G2/ Y 1.001.194.XXE Toggle relay M3 24V time-limited B negative edge triggered S2/ G2/ Y 1.001.294.XXE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Design may be subject of change – no guarantee for this information. 89 Toggle relay time limited compact DESCRIPTION The application range of toggle time-delayed compact is the switch-on and -off of loads by impulse operation with a limited on-time. Please specify the required on-time in your order. FUNCTION Diagram S1: Using toggle relay compact a load can be switched on and off via push button. If a positive / negative impulse is applied at terminal 15, the relay switches its state (on or off). The on-time is limited. Diagram S2: The contacts are seperated from the trigger, therefore they can be used in combinations. Regarding version S2 the relay contact is completely potential-free thus it is able to switch alternating voltage. For different housing please see in the chapter housing and baseplates. TECHNICAL DATA Technical Data Value Housing dimension 30 x 30 x 30 mm Operating temp. -40 °C to 85 °C Continuous current 30 A Max. switching volt. 75 VDC Max. switching curr. 60 A Max. switch-on curr. 100 A Quiescent current 1 mA Ingress protection IP53 E1 approval number 04 7281 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 90 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Toggle relay M1 12V time-limited A positive edge triggered S1/ G1/ E 1.001.181.XXE Toggle relay M1 24V time-limited A positive edge triggered S1/ G1/ E 1.001.281.XXE Toggle relay M1 12V time-limited A negative edge triggered S1/ G1/ E 1.001.182.XXE Toggle relay M1 24V time-limited A negative edge triggered S1/ G1/ E 1.001.282.XXE Toggle relay M1 12V time-limited B positive edge triggered S2/ G1/ Y 1.001.183.XXE Toggle relay M1 24V time-limited B positive edge triggered S2/ G1/ Y 1.001.283.XXE Toggle relay M1 12V time-limited B negative edge triggered S2/ G1/ Y 1.001.184.XXE Toggle relay M1 24V time-limited B negative edge triggered S2/ G1/ Y 1.001.284.XXE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 91 Voltage range monitor DESCRIPTION Voltage monitoring relay switches-on or -off consumer when certain threshold voltage is exceeded or falls below. FUNCTION The relay with monitoring of a voltage level switches consumer off as soon as a certain threshold voltage at terminal 15 is exceeded or falls below. The standard thresholds are for 12 V applcations 11,5 V/ 12,5 V and for 24 V applcations 23,0 V/24 V.The voltage thresholds can be user defined. Also a combinations with delay times are possible. The range monitor (window comparator) switches consumer off or on as soon as the voltage is in a certain range. Please define the range when ordering. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Battery monitoring for load lifts, touring buses Signal limit check e.g. pressure monitoring TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Switching point/ hysteresis custom defined Continuous current 10A/ 15 A (no/ nc) Ingress protection IP53 Quiescent current 250 µA EMC 2006/ 96 EG e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. FUNCTION DIAGRAM DESIGN 92 CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Voltage monitor 12 V A Voltage thresholds S1/ G2/ E standard: 11,5 V / 12,5 V, or according to customer 1.008.100.00E Voltage monitor 24 V A Voltage thresholds S1/ G2/ E standard: 23,5 V / 24,5 V, or according to customer 1.008.200.00E Voltage monitor 12 V A Voltage thresholds S1/ G2/ E standard: 11,5 V / 12,5 V, or according to customer 1.008.126.00E Voltage monitor 24 V A Voltage thresholds S1/ G2/ E standard: 23,5 V / 24,5 V, or according to customer 1.008.226.00E Voltage monitor 12 V B Voltage thresholds S2/ G2/ Y standard: 11,5 V / 12,5 V, or according to customer 1.008.156.00E Voltage range monitor 12 A V voltage range: customer specific S1/ G2/ E 1.008.127.00E Voltage range monitor 24 A V voltage range: customer specific S1/ G2/ E 1.008.227.00E Voltage range monitor 9-30 V A voltage range: customer specific S4/ G2/ E 1.008.300.00E Voltage range monitor 12 B V voltage range: customer specific S2/ G2/ Y 1.008.150.00E Voltage range monitor 24 C V voltage range: customer specific S3/ G2/ E 1.008.240.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 93 Housing Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3 mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8 mm 0,5-1,0mm Bracket for housing 2 105292 1.017.080.00 Design may be subject of change – no guarantee for this information. 94 Voltage monitor relay with reset DESCRIPTION The voltage monitorrelay with reset has outputs for indicator/buzzer (signal horn) e..g. It switches an acoustic or optical signal when a defined voltage exceeds or under-run. FUNCTION Under-running the lower voltage threshold at terminal 15 the outputs 87, 87a and c are switched on. By reset input x the output 87 can be switched off again, the outputs 87 a and c stay on. Is the upper voltage threshold exceeded, all outputs are switched off. Other voltage thresholds are availlable on demand. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Analog value check e.g. pressure check. TECHNICAL DATA Technical Data Value Operating temp. -40 °C bis 85 °C Max. output current (87, 87 A) 4 A, short-circuit and overload-proof Max. output load (C) 2 W, not protected Time delay 10 s Protection class IP53 EMC 2006/ 96 EG e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 95 ORDER TABLE Technical Data Ausführung Housing Ordering Nr. Voltage monitor with reset 12 V thresholds: 11,5 V / 12,5 V; undervoltage monitor with 87a G2/ T 1.008.110.00E Voltage monitor with reset 24 V thresholds: 23,0 V / 25,0 V; undervoltage monitor with 87a G2/ T 1.008.210.00E Voltage monitor with reset 12 V thresholds: 11,5 V / 12,5 V; undervoltage monitor w/ o 87a G2/ T 1.008.111.00E Voltage monitor with reset 24 V thresholds: 23,0 V / 25,0 V; undervoltage monitor w/ o 87a G2/ T 1.008.211.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.00 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 96 Frequency monitor DESCRIPTION Frequency monitor relay switches-on or -off consumer when certain threshold frequency is exceeded or falls below. FUNCTION The relay will measure a frequency and switches consumer off/on as soon as a certain threshold frequency at terminal 15 is exceeded or falls below.The frequency thresholds can be user defined, frequency range 10 - 1.000 Hz. Also a combinations with delay times are possible. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Automatic start Rotation measurement Flow rate TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Switching frequency custom defined Continuous current 10A/ 15 A (no/ nc) Time tolerance +/ - 1 ms Ingress protection IP53 Quiescent current 250 µA EMC 2006/ 96/ EG DIN 40839 e1 approval number 03 3218 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 97 ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Frequency monitor 12 V relay A xxx = frequency in Hz S1/ G2/ E 1.026.111.xxxE Frequency monitor 24 V relay A xxx = frequency in Hz S1/ G2/ E 1.026.211.xxxE Frequency monitor 12 V relay B xxx = frequency in Hz S2/ G2/ Y 1.026.112.xxxE Frequency monitor 24 V relay B xxx = frequency in Hz S2/ G2/ Y 1.026.212.xxxE Frequency monitor 19 30 V HSD A xxx = frequency in Hz S3/ G2/ E 1.026.311.xxxE Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 98 Flasher unit DESCRIPTION Flasher units start/stop M3 are used for indicators and warning signals. The flasher unit can be used for different types of vehicles. FUNCTION All diagrams: If supply voltage applied to terminal 30/87z the flasher starts immediatly. It generates 90 +/-30 pulses per minute. The output can drive up to 20 A, higher loads can be driven by by using a power relay. For different housing please see in the chapter housing and baseplates. TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C continuous current 30 A max. switching volt. 75 VDC max. switching curr. 60 A max. switch-on curr. 100 A Quiescent current 1 mA Flash frequency 90 +/ -30 Impulses per min. Ingress protection IP53 Life span 1 x 10less than supgreater than 5less than / supgreater than with ohmic load e1 approval number 03 5388 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE 99 Technical Data Type Housing Ordering Nr. Flasher unit M3 Start/ Stop 12V A S1/ G2/ E 1.007.191.00E Flasher unit M3 Start/ Stop 24V A S1/ G2/ E 1.007.291.00E Flasher unit M3 Start/ Stop 12V B S2/ G2/ Y 1.007.192.00E Flasher unit M3 Start/ Stop 24V B S2/ G2/ Y 1.007.292.00E Flasher unit M3 Start/ Stop 12V C S3/ G2/ E 1.007.193.00E Flasher unit M3 Start/ Stop 24V C S3/ G2/ E 1.007.293.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 100 Universal flasher unit DESCRIPTION Electronic universal flasher units are used for indicators and warning signals. The flasher unit can be used for different types of vehicles. Versions are available with LED indication (additional indication of function) or start/stop. FUNCTION Diagram S1: If supply voltage applied to terminal 49 the flasher starts immediatly. It generates 90 +/-30 pulses per minute. The output can drive up to 10 W, higher loads can be driven by using a power relay. Diagram S2: On demand the flasher unit is available with status LED. Diagram S3: To terminal 30 supply voltage is applied. If signal voltage is applied to terminal 15 the flasher starts. 90 +/- 30 pulses are generated per minute. The ouptut can drive up to 80 W, higher loads can be driven by using an additional power relay. On demand the flasher unit is available with C output, it is driven inversely to the power output. For different housing please see in the chapter housing and baseplates. APPLICATION EXAMPLES Turn signal Hazard light Hazard horn TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C response voltage greater than =9 V Voltage drop less than =0,5 V (with max. Nominal load) Response threshold less than =0,5 W Response time less than =0,2 sec. Flash frequency 90 +/ -30 Impulses per min. Ingress protection IP53 Life span greater than 20.000.000 Switching cycles Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM 101 ORDER TABLE Technical Data Type Housing Ordering Nr. Universal-flasher unit 9-30V/ 10W A S1/ G1/ J 1.007.300.00E Universal-flasher unit 9-30V/ 80W A S1/ G1/ J 1.007.305.00E Universal-flasher unit 9-30V/ 100W A S1/ G1/ J 1.007.307.00E Universal-flasher unit 9-30V/ 80W mit Top-LED B S2/ G1/ J 1.007.306.00E Universal-flasher unit 9-30V/ 100W mit Top-LED B S2/ G1/ J 1.007.308.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Faston terminal 2,8mm 0,5-1,0mm 2 105292 Design may be subject of change – no guarantee for this information. 102 Universal flasher LED DESCRIPTION The universal flasher LED is suitable for LED lights and for lights with lamps. This flasher is suitable for left and right flashing with warning flashing function and frequency doubling at lamp/LED loss. Clamp C is the turn signal lamp control output. If a light in the turn signal mode fails, the flashing frequency doubles itself at clamp C (C2 function). FUNCTION To the turn signal input left or right if operating voltage is applied, the flasher starts directly. Is at the input warning flashing or at both turn signal inputs operating voltage applied, the function warning flashing is activated . Over (after customer's request) current thresholds adjustable losses of the attached lamps and/or LED lights are recognized at each of the 4 output channels. The flash frequency immediately doubles (C2 function). During the function warning flashing the flash frequency is not doubled. TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C flasher output max. 21W/ channel Status output C 3W current threshold 140 mA at 12 V current threshold 70 mA at 24 V Flash frequency 90 +/ -30 Impulses per min. Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE 103 Technical Data Housing Ordering Nr. Universal flasher unit LED 12 V - 4 Kanal S1/ G2/ T 1.007.110.00E Universal flasher unit LED 24 V - 4 Kanal S1/ G2/ T 1.007.210.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Programming tool MRS Realizer I 1.100.000.01 Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 104 105 Standard relay TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Characteristics High resistance to shocks, small contact losses Ingress protection IP53 Housing dimension CB1 22 x 26 x 25 mm Housing dimension V23134 26 x 26 x 25 mm Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Pinning Ordering Nr. Manufacturer: Panasonic -- -- -- -- Relay ST S CB1A-R-24V A 20A Normally open contact with resistor S2 1.015.203.00 Relay ST S CB1A-D-12V A 40A / discontinued on March 2015 Normally open contact with diode S3 1.015.105.00 Relay ST S CB1A-M-12V A Normally open contact S1 1.015.107.00 106 Technical Data Type Pinning Ordering Nr. Normally open contact with resistor and mounting bracket S2 1.015.209.00 Relay ST W CB1-12V 40/ B 30A Two way contact S4 1.015.100.00 Relay ST W CB1-24V 20/ B 10A Two way contact S4 1.015.200.00 Relay ST W CB1-R-12V 40/ 30A B Two way contact with resistor S5 1.015.102.00 Relay ST W CB1-R-24V 20/ 10A B Two way contact with resistor S5 1.015.202.00 Relay ST W CB1-D-12V B 40/ 30A / discontinued on March 2015 Two way contact with diode S6 1.015.104.00 Relay ST W CB1-D-24V B 20/ 10A / discontinued on March 2015 Two way contact with diode S6 1.015.204.00 Relay ST W CB1-D-M-12V 40/ 30A / discontinued on March 2015 B Two way contact with diode and mounting bracket S6 1.015.110.00 Relay V23134-A0052-C643 12V 40/ 30A B Two way contact S4 1.015.153.00 Relay V23134-A0053-C643 24V 20/ 15A B Two way contact S4 1.015.253.00 Relay V23134-A1052-C643 12V 40/ 30A L B Two way contact with mounting bracket S4 1.015.155.00 -- -- -- -- -- Manufacturer: Hongfa -- -- -- -- Relay W HFV4/ 012-1Z1SGD2 B Two way contact with diode S6 1.015H.104.00 Relay W HFV4/ 024-1Z1SGD2 B Two way contact with diode S6 1.015H.204.00 Relay W HFV4/ 012-1Z4SGD2 B Two way contact with diode and mounting bracket S6 1.015H.110.00 Relay W HFV4/ 024-1Z4SGD2 B Two way contact with diode and mounting bracket S6 1.015H.210.00 Relay S HFV4/ 012-1H1S- A GD2 Normally open contact with diode S3 1.015H.105.00 Relay S HFV4/ 024-1H1S- A GD2 Normally open contact with diode S3 1.015H.204.00 -- -- -- -- -- Manufacturer: Maluska -- -- -- -- Relay FRC1BC-1NS-DC24V B Two way contact with diode S6 1.015M.204.00 40A Relay ST S CB1A-R-M-24V 20A Ausführung with mounting bracket A Design may be subject of change – no guarantee for this information. 107 ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 Faston terminal 6,3 mm 1mm 2 103064 102355 Design may be subject of change – no guarantee for this information. 108 Standard relay with special terminals TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Characteristics High resistance to shocks, small contact losses Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Pinning Ordering Nr. Relay ST S RLPS/ 4-12 12V 40A A normally open contact 2 x 87 G1 S1 1.015.164.00 Relay ST S RLPA/ 4-12 12V 40A B normally open contact with mounting bracket G1 S1 1.015.161.00 Relay ST W RLPS/ 52-12 12V 40/ 15A C two way contact G1 S4 1.015.151.00 Relay ST W RLPS/ 52-24 24V 22/ 10A C two way contact G1 S4 1.015.251.00 Relay ST W RLPS/ C two way contact with G1 S6 1.015.278.00 109 Technical Data Type Ausführung 52-24D 24V 22/ 10A Relay ST W RLP/ 52-24 24V 22/ 10A Housing Pinning Ordering Nr. diode C two way contact with G1 mounting bracket S4 1.015.250.00 Relay ST W RLP/ C 52-12R 12V 40/ 15A two way contact with G1 resistor and mounting bracket S5 1.015.156.00 Relay ST W RLP/ C 52-24R 24V 22/ 10A two way contact with G1 resistor and mounting bracket S5 1.015.256.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 Faston terminal 6,3 mm 1mm 2 103064 102355 Design may be subject of change – no guarantee for this information. 110 Micro Relay TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Characteristics High resistance to shocks, small contact losses Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Pinning Ordering Nr. Manufacturer: Panasonic -- -- -- -- Relay MI W CM1-12V 35/ B 20A Two-way contact S4 1.014.100.00 Relay MI W CM1-24V 15/ B 8A Two-way contact S4 1.014.200.00 Relay MI W CM1-R-12V 35/ 20A B Two-way contact w. resistor S5 1.014.102.00 Relay MI W CM1-R-24V 15/ 8A B Two-way contact w. resistor S5 1.014.202.00 111 Technical Data Ausführung Pinning Ordering Nr. Relay MI W CM1-D-12V B 35/ 20A / discontinued on March 2015 Type Two-way contact w. diode S6 1.014.104.00 Relay MI W CM1-D-24V 15/ 8A / discontinued on March 2015 B Two-way contact w. diode S6 1.014.204.00 Relay MI S CM1A-12V 35A A Normally open contact S1 1.014.101.00 Relay MI S CM1A-24V 15A A Normally open contact S1 1.014.201.00 Relay MI S CM1A-R-12V A 35A Normally open contact with resistor S2 1.014.103.00 Relay MI S CM1A-D-12V A 35A / discontinued on March 2015 Normally open contact with diode S3 1.014.105.00 -- -- -- -- -- Manufacturer: Hongfa -- -- -- -- Relay S HFV6/ 012-ZSTD A Normally open contact with diode S3 1.014H.105.00 Relay W HFV6/ 024-ZSTD B Two-way contact with diode S6 1.014H.204.00 -- -- -- -- -- Manufacturer: Maluska -- -- -- -- Relay FRC/ BC-SN-DC24V B Two-way contact with diode S6 1.014M.204.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.000.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm 102355 Faston terminal 4,8 mm 0,5-1mm2 Faston terminal 4,8 mm 1,0-2,5mm 103064 108304 2 108305 Design may be subject of change – no guarantee for this information. 112 Power relay TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Characteristics High resistance to shocks, small contact osses Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Ausführung Housing Pinning Ordering Nr. Relay H S CB1A-H-12 12V 50A normally open contact G1 S1 1.016.155.00 Relay H S RLACS/ 4-12 12V 70A normally open contact G1 S1 1.016.152.00 Relay H S RLACS/ 4-24 24V 40A normally open contact G1 S1 1.016.252.00 Relay Normally open contact V23134-J0052-D642 12V 50A G1 S1 1.016.100.00 Relay Normally open contact V23134-J0053-D642 24V G1 S1 1.016.200.00 Relay two way contact with V23134-J0053-D642 24V resistor R G1 S2 1.016.201.00 Relay two way contact with V23134-J0053-D642 24V diode D G1 S3 1.016.202.00 Relay G1 S1 1.016.203.00 Normally open contact 113 Technical Data Ausführung Housing Pinning V23134-J1053-D642 24V with mounting bracket L Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.001.00 Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal Einrast 9,5mm 4-6mm2 103066 Design may be subject of change – no guarantee for this information. 114 Ordering Nr. Power relay with screw terminals TECHNICAL DATA Technical Data Value operating temp. -30 °C to 80 °C Characteristics High resistance to shocks, small contact losses Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Pinning Ordering Nr. Relay H S RL/ 180-12 12V 100A A normally open contact with screwing terminals and mounting bracket S1 1.016.154.00 Relay H S RL/ 80-24 24V A 60A normally open contact with screwing terminals and mounting bracket S1 1.016.254.00 Relay H S RP/ 120-12 12V 120A B normally open contact with screwing terminals and mounting bracket S1 1.016.158.00 Relay H S RP/ 100-24 24V 100A B normally open contact with screwing terminals and mounting bracket S1 1.016.258.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Faston terminal 6,3mm 1,5-2,5mm2 103064 Faston terminal 6,3 mm 1mm2 102355 Design may be subject of change – no guarantee for this information. 115 Relay with special contacts DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Pinning Ordering Nr. Relay ST DS RDPS/ A 5-12 12V 2x20A Double normally open contact G1 S1 1.020.179.00 Relay ST DS RDPS/ A 5-24 24V 2x10A Double normally open contact G1 S1 1.020.279.00 Relay ST DS RDPS/ A 5-24D 24V 2x10A Double normally open contact with diode G1 -- 1.020.284.00 Relay ST DS RDPS/ A 5-12R 12V 2x20A Double normally open contact with resistor G1 -- 1.020.186.00 Relay ST DS RDP/ 5-12 12V 2x20A A Double normally open contact with mounting bracket G1 S1 1.020.183.00 Relay ST DS RDP/ 5-24 24V 2x10A A Double normally open contact with mounting bracket G1 S1 1.020.283.00 Relay V23134M0052-C642 12V 2x25A A Double normally open contact G1 S1 1.020.176.00 Relay V23134M0053-C642 24V 2x15A A Double normally open contact G1 S1 1.020.276.00 Relay V23134M1052-C642 12V 2x25A L A Double normally open contact with mounting bracket G1 S1 1.020.180.00 Relay V23134M1053-C642 24V A Double normally open contact with G1 S1 1.020.280.00 116 Technical Data Type Ausführung 2x15A L Housing Pinning Ordering Nr. mounting bracket Relay ST S RLPS/ 5-24 24V 22A B normally open contact 2 x 87 G1 S2 1.020.270.00 Relay ST S RLPS/ 5-24R 24V 22A B normally open contact 2 x 87 with resistor G1 -- 1.020.289.00 Relay ST S RLP/ 5-12 12V 40A B normally open contact 2 x 87 with mounting bracket G1 S2 1.020.187.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 Faston terminal 6,3 mm 1mm 2 103064 102355 Design may be subject of change – no guarantee for this information. 117 Solid state relay DESCRIPTION Solid state relays can be used to switch lamps, ohmic and inductive loads. They switch noiseless and are absolutely wear-free. FUNCTION Concerning size and pin arrangement, they are compatible with normal ISO Mini relays. Sodid state relays are short-circuit, overload and temperature protected. In case of short-circuit they switch off quicker than a fuse and they have a low quiescent current. For different housing please see in the chapter housing and baseplates. TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Ingress protection IP53 Quiescent current approx. 50 µA E1 approval number for 1.018.300.00 03 6819 E1 approval number for 1.018.301.00 03 6819 E1 approval number for 1.018.302.00 03 6819 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Housing Ordering Nr. Solid-state relay S 9-30V A 4A normally open contact S1/ G1/ U 1.018.300.00E Solid-state relay S 9-30V A 15A normally open contact S1/ G1/ U 1.018.301.00E Solid-state relay S 9-30V A normally open contact S1/ G1/ U 1.018.302.00E 118 Technical Data Type Ausführung Housing Ordering Nr. Solid-state relay S 9-30V A 15 A neg. normally open contact S1/ G1/ U 1.018.304.00E Solid-state relay 9-30V 5A Half bridge S2/ G2/ E 1.018.360.00E 25A C Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 119 Special relays DESCRIPTION Special relays are all relays which are not part of our standard product range. As example we show some special relays which can be ordered with different snubber circuits e.g. decoupling diode and/or recovery diode. Ohter possiblitlies can be quoted on demand. TECHNICAL DATA Technical Data Value operating temp. -40 °C to 85 °C Characteristics High resistance to shocks, small contact losses Ingress protection IP53 Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Ausführung Housing Ordering Nr. Special Relay S 12V 30A normally open contact S4/ G2/ U 1.023.14X.00 Special Relay W 12V 20A two way contact S1/ G2/ E 1.023.15X.00 Special Relay W 24V 20 A two way contact S1/ G2/ E 1.023.25X.00 Special Relay DR 12V 2x10A Double relay S6/ G2/ T 1.023.18X.00 Special Relay DR 24V 2x10A Double relay S6/ G2/ T 1.023.28X.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin Socket 1.017.002.00 120 Technical Data Ordering Nr. Faston terminal 6,3mm 1,5-2,5mm2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. FUNCTION TABLE Additional ordering-information x = 0: standard x = 1: decoupling diode x = 2: flyback diode x = 3: resistor x = 4: decoupling x = 5: resistor Design may be subject of change – no guarantee for this information. 121 122 Diode combinations APPLICATION EXAMPLES Flywheeling diodes Decoupling of headlights Logic functions TECHNICAL DATA Technical Data Value Operating temp. -40 °C to 85 °C Max. permanent current 3 A to 6 A Design may be subject of change – no guarantee for this information. DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Ausführung Housing Betriebsdaten Ordering Nr. Diode combination 1x einzeln 3A/ 1300V Single Diode S0/ G6 3A 1.006.600.00E Diode combination 2x einzeln 6A/ 400V Single Diodes S1/ G1/ U/ Typ A 6A 1.006.654.00E Diode combination 2x einzeln 3A/ 1300V Single Diodes S1/ G1/ U/ Typ A 3A 1.006.652.00E Diode combination 4x einzeln 3A/ 1300V Single Diodes S2/ G1/ AE/ Typ C 3A 1.006.660.00E Diode combination 4x Diodes common cathode S3/ G1/ E/ Typ B 3A 1.006.661.00E 123 Technical Data Ausführung Housing Betriebsdaten Ordering Nr. Diode combination 4x gem. Anode 3A/ 1300V Pin5 Diodes common anode S4/ G1/ E/ Typ B 3A 1.006.662.00E Diode combination 4x gem. Kath. 3A/ 1300V Pin8 Diodes common cathode S6/ G1/ E/ Typ B 3A 1.006.663.00E Diode combination 4x gem. Anode 3A/ 1300V Pin8 Diodes common anode 3A 1.006.664.00E gem. Kath. 3A/ 1300V Pin5 S5/ G1/ E/ Typ B Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Flat pin socket 1.017.002.00 Faston terminal 6,3mm 1,5-2,5mm 2 2 103064 Faston terminal 6,3 mm 1mm 102355 Faston terminal 2,8mm 0,5-1,0mm2 105292 Bracket for housing 1.017.080.00 Design may be subject of change – no guarantee for this information. 124 Relay sockets for flat pin DESIGN ORDER TABLE Technical Data Ausführung Ordering Nr. Socket MI FL 5pol. 2x6.3/ 3x4.8 2x6,3/ 3x4,8, attachable 1.017.000.00 Socket H FL 9pol. 2x9.5/ 3x6.3/ 4x2.8 2x9,5/ 3x6,3/ 4x2,8, attachable 1.017.001.00 Socket ST FL 9pol. 5x6.3/ 4x2.8 5x6,3/ 4x2,8, attachable 1.017.002.00 Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Faston terminal 6,3mm 1,5-2,5mm 2 2 Faston terminal 6,3 mm 1mm Faston terminal 2,8mm 0,5-1,0mm 103064 102355 2 Faston terminal Einrast 9,5mm 6-10mm2 105292 102354 Design may be subject of change – no guarantee for this information. 125 DIN rail adaptor DESCRIPTION The control cabinet adapter makes the mouting on a DIN rail possible. FUNCTION On the input clamps there are 12/24 Volt signals, input as well as output By means of relay there is the possiblity to switch 230V AC 8 A loads respektively combinations Supply, ground and on signal are on double clamps, which enables a loop through DESIGN ORDER TABLE Technical Data Ordering Nr. DIN rail adaptor without relays 1.031.000.00 Design may be subject of change – no guarantee for this information. 126 Load dump protection module DESCRIPTION The load dump protection module is for protection against voltage peaks. TECHNICAL DATA Technical Data Value Operating voltage 9 - 32 V DC Operating temperature -40 °C up to 85 °C Protection class IP 53 Housing dimensions 30 x 30 x 30 mm Design may be subject of change – no guarantee for this information. CONNECTION DIAGRAM ORDER TABLE Ordering Nr. 1.051.300.00E Design may be subject of change – no guarantee for this information. ACCESSOIRES Technical Data Ordering Nr. Socket 1.017.002.00 Faston terminal 6,3 mm 1,5-2,5 mm² 103064 Faston terminal 6,3 mm 1 mm² 102355 Design may be subject of change – no guarantee for this information. 127 Housing and baseplates DESIGN CONNECTION DIAGRAM ORDER TABLE Technical Data Type Ausführung Ordering Nr. Housing 30 x 30 x 30 mm G1 -- 1.017.070.00 Housing 30 x 30 x 40 mm G2 -- 1.017.071.00 Housing 30 x 30 x 50 mm G3 -- 1.017.072.00 Housing 60 x 30 x 60 mm G7 -- 1.017.073.00 Housing 60 x 30 x 60 mm G7 with fixing brackets 1.017.074.00 Baseplate 8-pol. GP8/ AE -- 1.017.060.00 Baseplate 5-pol. GP5/ E -- 1.017.061.00 Baseplate 3-pol. GP3/ J -- 1.017.062.00 Baseplate 7-pol. GP7/ S -- 1.017.063.00 Baseplate 9-pol. GP9/ T -- 1.017.064.00 Baseplate 4-pol. GP4/ U -- 1.017.065.00 128 Technical Data Type Ausführung Ordering Nr. Baseplate 6-pol. GP6/ Y -- 1.017.066.00 Design may be subject of change – no guarantee for this information. 129 Powered by TCPDF (www.tcpdf.org)
© Copyright 2024 ExpyDoc