Primary voltage: 440, 460, or 480 V UL certification: UL 506

Code: FUL5502
(Single-phase Dry-type Insulated
Transformers with Class-B Insulation)
Primary voltage: 440, 460, or 480 V
UL certification: UL 506
Secondary voltage: 100, 110, or 120 V
Capacity
(VA)
Model
L
LP
W
WP
H
Installation
holes(A×B)
360
NESB360FUL5502-03
133
97
180
89
150
Dia. 7 x 14
600
NESB600FUL5502-05
152
113
210
120
165
Dia. 7 x 18
840
NESB840FUL5502-07
177
120
205
109
190
Dia. 8 x 15
1.2 k
NESB1200FUL5502-10
200
140
210
125
210
1.8 k
NESB1800FUL5502-15
200
140
260
165
215
2.4 k
NESB2400FUL5502-20
200
160
240
170
280
3.6 k
NESB3600FUL5502-30
250
200
250
145
325
4.8 k
NESB4800FUL5502-40
250
200
290
185
330
6 k
NESB6000FUL5502-50
250
200
310
205
330
Code: NUL5502
Dia. 10 x 15
8 x 16 U-cut
Terminal block
(P/S/E ・G)
TX10/TX10/TX10
TX10/TX20/TX20
Weight
(Kg)
18
No. 3
27
33
10 x 20 U-cut
No. 2
(1)
26
TX20/TX30/TX30
Standard
case
No. 1
7
12
16
TX20/TX20/TX20
Shape
TX30/TX60/TX60
44
TX30/TX60/TX60
52
(2)
No. 4
No. 5
(Single-phase Dry-type Insulated
Transformers with Class-H Insulation)
Primary voltage: 440, 460, or 480 V
UL certification: UL 506
Secondary voltage: 100, 110, or 120 V
Capacity
(VA)
Model
L
LP
W
WP
Installation
holes(A×B)
H
360
NESH360NUL5502-03
152
113
190
85
170
600
NESH600NUL5502-05
152
113
210
112
165
NESH840NUL5502-07
177
120
215
119
190
NESH1200NUL5502-10
200
140
200
125
210
1.8 k
NESH1800NUL5502-15
200
140
250
155
215
2.4 k
NESH2400NUL5502-20
230
160
230
130
250
3.6 k
NESH3600NUL5502-30
230
160
270
170
250
4.8 k
NESH4800NUL5502-40
230
160
310
180
270
-
840
1.2 k
6 k
NESH6000NUL5502-50
230
160
310
180
300
7.2 k
NESH7200NUL5502-60
260
180
310
190
310
9 k
NESH9000NUL5502-75
260
180
350
210
315
12 k
NESH012NUL5502-00
370
160
350
180
355
Terminal block
Screw diameter
Dia. 7 x 18
Dia. 8 x 15
Terminal block
(P/S/E・ G)
TX10/TX10/TX10
Weight
(Kg)
Shape
8
11
TX10/TX20/TX20
Standard
case
17
No. 2
(1)
18
24
TX20/TX30/TX30
No. 3
25
37
Dia. 10 x 15
42
TX30/TX60/TX30
50
(3)
No. 4
57
Dia. 13 x 18
TX30/TX100/TX30
67
TX60/TX150/TX60
75
No. 5
(4)
Rated voltage/rated current
Compatible wiring (AWG)
TX10
M3.5
600 V/20 A
20 to 14
Tightening torque
1.3 N-m
TX20
M4
600 V/30 A
18 to 10
1.8 N-m
TX30
M5
600 V/50 A
16 to 8
2.7 N-m
4.5 N-m
TX60
M6
600 V/80 A
14 to 4
TX100
M8
600 V/115 A
8 to 2
10 N-m
TX150
M8
600 V/175 A
6 to 2/0
10 N-m
Note: For connection to the terminal block, also use crimped terminals matched to the rating.
35
Shape (1)
Shape (2)
Terminal block
Terminal block
Terminal block
Terminal block
Shape (3)
Shape (4)