FG20341 FG20721 is a general purpose application battery. Within the FG range Fiamm offer 6V and 12V monoblocs at various amp hour capacities enable the right battery selection for each requirement. FIAMM Sealed Power is a Manufacturer of VRLA batteries; and is supported by a dedicated sales network with market knowledge and experience of small sealed lead acid battery applications. FIAMM Sealed Power FG series 12 Volt 3.4 Ah Features Nominal Voltage 12 Volt Nominal Capacity 3.4 Ah at 20 hours rate to 1.75 Vpc at 25 °C Float charging voltage 13.50 - 13.80 V/bloc at 25 °C Boost charge voltage 14.40 - 15.00 V/bloc at 25 °C Float voltage compensation -18mV/°C Maximum charging current 0.85 A Case ABS with HB flammability rate (according UL94) Internal resistance 106 mΩ in full charged conditionΩ Weight 1.41 kg Dimensions L x W x H (TH): 134 x 67 x 60 (67) Operative temperature range -20 °C to 50 °C Storage As batteries lose part of their capacity, during storage, due to self discharge. Fiamm Sealed Power recommends FG range of batteries can be stored for 6 months at an ambient temperature of 20 and 25 °C (see attached graph on reverse). Longer storage requires a recharge. This should be carried out in line with Fiamm Sealed Power recommended method; 2.4 V/cell for no longer than 24 hours at 20 °C Faston 4.8 mm 4.75 3.4 67 60 www.fiamm.com FG 20341 12V 3.4Ah Rechargeable Lead Acid Battery 6.45 9.87 0.8 NON SPILLABLE BATTERY RISK OF FIRE, EXPLOSION OR BURN DO NOT DISASSEMBLE, HEAT ABOVE 50°C OR INCINERATE BATTERY MUST BE RECYCLED 11.7 Charging Instruction (at 20°C) STANDBY USE CYCLIC USE 14.4 - 15.0 V 13.50 - 13.80 V 0.85 A MAX VOLTAGE REGULATION INITIAL CURRENT 67 The dimensions have a tollerance of : ± 1.6% 134 FG series 100 Capacity loss during storage at various temperatures The battery can be used without refreshing charge 80 Refreshing charge at 2.4 Vpc for 24 hours (at 2025°C) must be applied as soon as possible. 5°C 60 Refreshing charge of 2.4 Vpc may be insufficient to recover the battery capacity. It is important to avoid this area 0 2 4 6 0.10 C20 60 40 0.05 C20 13 16 18 20 13 Recharged Capacity (%) 12 11 10 12 11 10 2.60 C 2 C 20 0 14 Charging Current (A) 0 Discharge 100% 50% 1 0 1.22 C 0.68 C 0.26 C 0.10 C 0.05 C 9 10 100 1.000 10.000 Discharge time (min) 0 10 5 15 20 25 Charging time (h) Constant Current discharge table (Amperes) end voltage 5 min 10 min 15 min 20 min 30 min 45 min 1 hour 2 hour 3 hour 5 hour 10 hour 20 hour 09.60 10.6 7.11 5.59 4.63 3.55 2.62 2.13 1.21 0.86 0.56 0.31 0.18 09.90 9.88 6.83 5.39 4.52 3.47 2.57 2.10 1.20 0.85 0.55 0.31 0.18 10.02 9.60 6.69 5.30 4.46 3.42 2.54 2.07 1.19 0.85 0.55 0.31 0.17 10.20 9.32 6.55 5.20 4.40 3.37 2.52 2.05 1.18 0.84 0.55 0.31 0.17 10.50 8.76 6.25 4.97 4.18 3.24 2.45 2.00 1.15 0.83 0.54 0.30 0.17 10.80 8.30 5.96 4.77 3.98 3.13 2.37 1.90 1.10 0.79 0.51 0.29 0.17 Constant Power discharge table (Watts per bloc) end voltage 5 min 10 min 15 min 20 min 30 min 45 min 1 hour 2 hour 3 hour 5 hour 10 hour 20 hour 09.60 106 74.1 59.3 49.7 38.7 29.1 24.0 13.8 9.87 6.42 3.61 2.05 09.90 99.2 71.3 57.3 48.7 38.0 28.6 23.7 13.7 9.81 6.41 3.60 2.05 10.02 96.5 69.9 56.4 48.1 37.5 28.4 23.4 13.6 9.78 6.38 3.60 2.05 10.20 93.8 68.5 55.4 47.6 37.0 28.1 23.2 13.5 9.75 6.38 3.59 2.04 10.50 88.4 65.5 53.2 45.3 35.8 27.5 22.7 13.3 9.61 6.28 3.57 2.03 10.80 84.2 62.8 51.3 43.5 34.8 26.7 21.7 12.8 9.23 6.02 3.46 1.99 FIAMM reserves the right to change or revise without notice any information or detail given in this pubblication 80 12 10 Discharge curves at different current / final voltage (at 25°C) Battery Voltage (V) 100 Battery Voltage (V) 14 Charging Voltage (V) 120 8 Storage Time (months) 15 Charging Current (A) Recharged Capacity (%) 140 25°C 40 MH27960 Battery Voltage and Charge Time for Standby Use (at 25°C) 30°C 40°C Remaining Capacity (%) FG20341_Ver_1_02/22/2008 FIAMM Sealed Power
© Copyright 2024 ExpyDoc