THIS DRAWING IS SUBJECT TO COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR PART OR IN ANY MANNER WHATSOEVER WITHOUT WRITTEN PERMISSION FROM CA ARCHITECTS CC GROUND FLOOR Note: FFL to be min 170 above ngl. NGL 2125 FFL 16.490 dpc dpc dpc dpm FFL 16.490 FFL 16.490 Floor Finish: Cement screed dpm dpm A B C 09/02/2013 21/11/2012 29/01/2013 Ready for Council Submission Costing Revised Design 875 Staff WC Dist.to boundary 7130 NGL dpc dpc dpm dpm FFL 16.490 dpc dpc dpm dpm FFL 16.490 concrete foundation to engineers details dpc dpm concrete foundation to engineers details SITE BOUNDARY Section A 1 : 75 NOTE: Reinforced concrete flat roof to engineers detail and specifications. Approved waterproofing - torch on Bitumastic membrane- by specialist on 70mm vermiculite insulation screed @ 1:60min fall to fullbore outlets. 10.00° Screed to slope 3000 FFL 16.490 Verandah Floor Level NGL Gully dpm Fill NOTE: 150mm concrete surface bed onto BRC mesh onto 250 microns PVC DPC onto 50mm sandbed onto well compacted earth poisoned by speciallst. Demolished building level Note: All stormwater to fall away from the structure and towards the lowest part of the site. 1000mm high balustrade FFL 16.440 Cement Screed dpc Ex.window 1000 16490 1860 New Coat of paint to Ex. building Ex.window FFL 16.490 GROUND FLOOR 2765 Existing Precast Fence 525 875 2000 Existing Precast Fence 16660 Foyer New Concrete Staircase 175 Riser, 300 Tread Concrete Stair to engineers detail Internal entrance to Existing CMSA Facility Ex.Rwpd 1200 2662 2125 Dining Area Service Hatch from Kitchen to Dining Area Lintel 925 All external double skinned walls to contain waterproofing Bitumastic paint between each skin. 875 Internal Wall Finish: Smooth plaster & paint Lintel U/S OF LINTEL NMC corncie 9.5mm Rhino board 2125 NMC corncie Note: All glazing to comply with part N of the NBR. Note: FFL to be min 170 above ngl. Ex.Roof Upstand beam to engineers detail and specification U/S OF WALLPLATE New 75x75mm aluminium rainwater downpipe to gully 15500 Date concrete foundation to engineers details Aluminium Roof - Grey Colomet S profile Sheeting on 38x38mm battens on SABS approved 114x38 timber trusses @760mm max c/c on 114x38mm wallplate tied down with galvanised iron hoop threaded through 4 courses of brickwork 18785 Rev shwr Internal Wall Finish: Smooth plaster & paint concrete foundation to engineers details Roof pitch @ 10 degrees 19660 Service hatch 925 Internal Wall Finish: Smooth plaster & paint Fill NOTE: 150mm concrete surface bed onto BRC mesh onto 250 microns PVC DPC onto 50mm sandbed onto well compacted earth poisoned by speciallst. SITE BOUNDARY 1 Internal Wall Finish: Smooth plaster & paint Kitchen Lintel Parking Bays 5000 2650 16660 Storage 3000 All external double skinned walls to contain waterproofing - Bitumastic paint - between each skin. dpc Note: All glazing to comply with part N of the NBR. Existing Precast Fence Dining Area Space to Accomodate 70 Students in an Examination Situation NMC corncie 1200 Lintel U/S OF LINTEL 9.5mm Rhino board ceiling 875 NMC corncie 18785 Revision Schedule Description U/S OF WALLPLATE 440 19660 SITE BOUNDARY Aluminium Roof - Grey Colomet S profile Sheeting on 38x38mm battens on SABS approved 114x38 timber trusses @760mm max c/c on 114x38mm wallplate tied down with galvanised iron hoop threaded through 4 courses of brickwork Note: All stormwater to fall away from Roof pitch @ 10 degrees the structure and towards the lowest part of the site. concrete foundation to engineers details gradient Ramp @ 1:12 Fill New coat of paint NGL concrete foundation to engineers details concrete foundation to engineers details concrete foundation to engineers details concrete foundation to engineers details 2 Section B 1 : 50 SIGNED FOR CONSTRUCTION Roof pitch @ 10 degrees NOTE: Reinforced concrete flat roof to engineers detail and specifications. Approved waterproofing - torch on Bitumastic membrane- by specialist on 70mm vermiculite insulation screed @ 1:60min fall to fullbore outlets. Aluminium Roof - Grey Colomet S profile Sheeting on 38x38mm battens on SABS approved 114x38 timber trusses @760mm max c/c on 114x38mm wallplate tied down with galvanised iron hoop threaded through 4 courses of brickwork Note: FFL to be min 170 above ngl. Upstand beam to engineers detail and specification NMC corncie New 75x75mm aluminium rainwater downpipe to gully Staff WC Disable WC Lintel U/S OF LINTEL 1.6 Lintel All external double skinned walls to contain waterproofing - Bitumastic paint - between each skin. 2125 Staff Quarters Internal Wall Finish: Smooth plaster & paint Existing Precast Fence 1.7 3000 18785 9.5mm Rhino board 1.8 wc whb wc 1.9 1.10 1.11 1.12 1.13 whb 16660 GROUND FLOOR Note: All stormwater to fall away from the structure and towards the lowest part of the site. 3 Section C 1 : 50 dpc FFL 16.490 dpc dpc dpm dpm Cement Screed NGL dpm 1.2 1.3 1.4 1.5 U/S OF WALLPLATE 875 19660 1. 1.1 Screed to slope Site Boundary C:\Users\Denise Govender\Desktop\Current jobs\CMSA\drawings\architect\working drawings\rev 4\Latest Design.rvt Note: All glazing to comply with part N of the NBR. NOTE: 150mm concrete surface bed onto BRC mesh onto 250 microns PVC DPC onto 50mm sandbed onto well compacted earth poisoned by speciallst. concrete foundation to engineers details 1.14 1.15 1.16 concrete foundation to engineers details ex. concrete foundation ARCHITECT: ................................................................................. GENERAL BUILDING NOTES: 1.17 1.18 GENERAL This drawing is not to be scaled, use figured dimensions only. All dimensions and heights to be checked and verified before any work commences on site. Any discrepancies shall be reported to the Architect immediately. All levels, heights of plinths, depth of excavations and number of steps to be finally checked by contractor on site. The site to be treated in accordance with S.A.B.S. code of practice N.0124-1977 with soil poisoning according to specialist details. Top of foundations to be a min. of 600mm below natural ground level Backfill to foundations Top of 170mm concrete surface bed to be min of 170mm above finished ground level Brickgrip S.A.B.S. embossed D.P.C. 375 MIC. under all walls, window cills and at changes in floor levels Electrical installation shall be an earth leakage system in distribution board as per local authorities requirements and certification. All building work to be carried out in accordance with Local Authorities building by-laws and regulations Contractor to allow for 2 stand pipes (Garden taps) All exposed hot water supply pipes to be lagged Gas bottle installation to be done by a registered Gas installer Gas installation to comply with N.B.R Gas installer to finish and issue 2 compliance certificates on completion Soil poisoning certificate to be finished on completion of application Contractor must allow for hardwood screening to the following items: all motor units, gas bottles & heat pump motors Contractor must allow for sand traps to all stormwater catch pits or stormwater surface drains No surface mounted pipes for A.C units allowed. All piping to be concealed. All galvanizing to be accordance with “SANS 121 (ISO 1461)" 2. 2.1 2.2 2.3 2.4 2.5 3. 3.1 3.2 4. 4.1 4.2 4.3 4.4 4.5 5. 5.1 5.2 FOUNDATIONS All foundations, foundation walls, structural concrete work and sub-soil stormwater drainage to Civil Engineers spec All soil compaction to Engineers spec 230X700mm concrete foundations for 230mm brick walls 300X1000mm pad foundations for 460X460mm brick coloumns All foundations to be reinforced as required by Engineer FLOORS 25mm cement screed to all floors 150mm thick concrete surface bed onto BRC re-inforced mesh onto 250 Micron PVC. DPC onto 50mm Umgeni sand on well compacted earth to be poisoned by specialist. WALLS 230mm brick walls with Brickgrip D.P.C. Brickforce every 6 courses and every course for 4 courses over openings All load bearing brick walls to be constructed of bricks having a min crushing strength of 14MPA. mortar to be CLASS 2 in accordance with NBR and SANS 10164 Window built in with Brickgrip D.P.C or similar approved. All paintwork to comply with manufacturers spec with neccessary undercoats ROOF PITCHED ROOF: Pitched roof to have Aluminium Roof Grey Colomet S profile Sheeting on 38x38mm battens on SABS approved sisalation 410 on 114x38 timber trusses @760mm max c/c on 114x38mm wallplate tied down with galvanised iron hoop threaded through, Isoboard ceiling on 38x38 brandering fixed to underside of timber roof trusses and skim joints and painted with approved NMC cornice. Refer to sections for roof pitch. 75x75mm aluminium rainwater downpipes from aluminium gutters 6. 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 7. 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 7.13 7.14 7.15 WINDOWS & DOORS Windows: as per window schedule Any pane of glass which is to be installed without a support frame shall be in accordance with SANS 10137 Thickness of panes in relation to their area shall be in accordance with SANS 10137 External sliding doors: as per door schedule Internal doors: Hardwood Mernati (to Interior Designers spec) French doors: doors as per schedule Any door leading from the garage into the house must be ‘CLASS B FIRE RATED’ door with self-closer. Internal doors to have a floor mounted ‘UNION’ Ref. AL8730AS. Aluminium door stop or a ‘UNION’ Ref. 8254AS aluminium wall mounted door stop. DRAINAGE NOTES 100dia. U.P.V.C sewer pipe drain with a min. fall of 1:60 100dia. OVP at head of drainpipe as shown Rodding Eyes at head of drain, at all changes of direction & @ max. of 25m intervals Inspection Eyes at all junctions of drain, & to have marked covers @ ground level Drain pipe under building to be protected against load All waste pipes to have 65mm re-seal traps, all waste pipes to be accessible over the entire length for cleaning & repairs All waste pipes under floor slab to be sleeved All soil fittings with vertical discharge greater than 1220 to have antisyphon ventpipes Rainwater downpipes to discharge @ MIN. OF 2440mm from any open gully All drainage to be carried out in accordance with Local authorities drainage and by-laws & regulations All waste pipes to be 50mm diameter All rainwater downpipes to fall onto concrete spreader Contractor to allow for 2 X PVC pipes under the driveway between the boundary and road edge The W.C is to be a close-coupled suite white with chrome ball -o- stop Plumber must allow for above-counter stop cocks for the dish washer and washing machine CLIENT: ......................................................................................... IF THIS DRAWING IS NOT SIGNED BY THE ARCHITECT IT IS NOT FOR CONSTRUCTION PURPOSES PROJECT Colledges of Medicine South Africa, Phase 1, ERF 9107/ 9108/ 9109/ 9110 Umbilo. 10/12/14/16 Lichfield Road DESCRIPTION Sections A , B & C C A ARCHITECTS CC Suite E MGA HOUSE Wimble Close Ballito Business Park Po Box 6438 Zimbali 4418 Tel: +27 32 946 3830/1 Fax: +27 86624 9592 caarchitects email: [email protected] reg no 2621 Drawn Denise. G Project nr: Sheet nr: 347 347-WRK01-300 Date: 2014/01/28 10:10:06 AM Rev Nr: C
© Copyright 2024 ExpyDoc