THE UNIQUE ANALYZER for Biogas, Biomethan, Landfill Gas, Coalbed Methane Also for use in hazardous area zone 2 according to II 3G Ex nA IIA T1 Gc The complete, ready to use biogas analyzer SWG100 is the industrial solution to be used with: biogas (anaerobic digestion) plants cogeneration heat and power engines (CHP) municipal or industrial waste water treatment sites coal seam gas sites (coal bed methane) food and animal waste processing plants biomethan (gas to grid) plants landfill sites SWG100 Instrument main features are: industry compatible rugged design for harsh industrial environment standard system safety included with continuously monitored fan ventilation of cabinet, gas flow restrictor orifice at gas inlet optional use in hazardous area zone 2, with compliance certificate according to II 3G Ex nA IIA T1 Gc efficient sample gas preparation for fast and reliable measurements sampling from low suction up to high pressure gas no dilution of the sample gas, neither use of compressed air is required direct and continuous/discontinuous measurement, with pressure and temperature compensation and event data logging up to 10 sites monitoring (time sharing technique) with only one analyzer ready to run delivery, minimum installation work SWG100 biogas standard option Basic analyzer for wall (rack) mounting, IP54 aluminum cabinet with anti-corrosive red structural lacquer Monitored ambient air ventilation with display and system alarm, including flow restrictor orifice and cutoff gas supply solenoid valve Sample gas pump and internal sample flow monitoring with display and system alarm Solenoid valve for auto-zero with ambient air 1/8” threads for all sample gas, zero gas and calibration gas inlets, fittings for DN6/4 mm tube 3,5” TFT color, backlit display and keyboard, password protected operation RS485 digital data transfer (Modbus RTU) Universal 90 - 240 Vac / 47 - 63 Hz / 90 W power supply CH4 and CO2 NDIR measurement O2 measurement with long-life EC cell H2S low measurement with EC cell protection (cut-off and purge) H2S high measurement with EC cell H2 or CO measurement with EC cell Use in hazardous area zone 2, category II 3G Ex nA IIA T1 Gc Combustible gas detector (%LEL) mounted inside analyzer cabinet Electric gas cooler (Peltier) with automatic condensate draining pump Auto-calibration using span gas mixture cylinder Multiple sampling point switchover from 2x up to maximum 10x sites Module with 4 channel analog outputs/inputs 4 - 20 mA and 2x alarm relays Analyzer remote control using 4x external relay contacts Converter module of RS485 into Profibus Cabinet heater for freeze protection THE UNIQUE ANALYZER for Biogas, Biomethan, Landfill Gas, Coalbed Methane MRU biogas analyzer of series SWG100, are designed for use in the harsh industrial environment of different sites where biogas is produced. Due to the unique design, the analyzer complies to EN60079-15 and RL 94/9/EG norms and can optionally be used in hazardous areas Zone 2, with manufacturer certificate of conformity according to II 3G Ex nA IIA T1 Gc The analyzer can be installed in outdoor or indoor location, can sample dry or wet biogas, pressurized or low pressure gas and can be used from single point sampling up to max 10 sampling points. Gas Cooler Peltier type Combustible gas detector (%LEL) Gas sampling pump Up to 10x switching biogas inlets (time sharing technique) with fail-safe shut-off solenoid valves and flow restrictor orifice NDIR bench for CH4 / CO2 measurement Auto-Zero and Auto-Cal solenoid valves EC cells for O2 / H2S low /H2S high with cut-off and purge for H2S Condensate draining pump Internal sample flow monitoring Continuous monitored ventilation fan with alarm Optional: cabinet heater Universal power supply 90 - 240 Vac 47 - 63 Hz / 90 W Up to 10x modules with analog outputs 4x 4 - 20 mA , RS485 and 2x alarm relays THE UNIQUE ANALYZER for Biogas, Biomethan, Landfill Gas, Coalbed Methane TECHNICAL SPECIFICATIONS Measured components Measuring ranges Measuring method CH4: CO2: O2: H2S low: H2S high: H2: Calculated component Calorific value: 0 – 50 MJ/m3; MJ/kg HMI human machine interface 3,5” TFT color display Backlit keyboard, password protected operation 4x analog output 4-20 mA, floating, max. load 500R 2 alarm relays, potential free contacts 24 Vdc/5 A RS485 digital interface (Modbus RTU) DIN-rail RS485 / ProfiBus converter System safety components Manufacturing compliance to II 3G Ex nA IIA T1 Gc Monitored cabinet ventilation fan Stainless steel flow restrictor orifice Sample gas shut-down solenoid valve LEL (CH4) monitoring inside cabinet Sample preparation Stainless steel gas fittings with 1/8” ID threads Electric gas cooler Teflon particulate filter, internal Viton hosing Monitored and regulated sample flow 40…60 l/h Sample inlet pressure: -100 mbar to + 300 mbar Sample venting: atmosphere pressure Cabinet dimensions Weight / Protection 600 x 600 x 210 mm (H x W x D) for wall or rack mounting 25kg / IP54 +5°C…+45°C or -20°C…+45°C with cabinet heater Indoor or outdoor (rain and sun shade is mandatory user scope of supply) Continuous, monitored fan ventilation Cabinet heater 200 W (option) Ambient temperature Installation site Cabinet conditioning Power supply 0 – 100 % (NDIR) 0 – 100 % (NDIR) 0 – 25 % (electrochemical, continuous) 0 – 1000 ppm (electrochemical, discontinuous) 0 – 10.000 ppm (electrochemical, continuous) 0 – 1.000 ppm (electrochemical, discontinuous) Universal 90 - 240 Vac / 47 - 63 Hz / 90 W (300 W with cabinet heater) DATA SUBJECT TO CHANGE WITHOUT NOTICE Simultaneous analysis of O2, CO2, CH4, H2S, NOx, gas pressure and temperature, with Li-Ion battery, SD card for data storage, see more details and features on our website MRU Measuring instruments for flue gases and environmental protection GmbH Fuchshalde 8 + 12 • 74172 Neckarsulm - Obereisesheim Phone +49 7132-99620 • [email protected] • www.mru.eu W-65333GB-K1-XX-064 MRU portable biogas and flue gas analyzers for CHP engine:
© Copyright 2024 ExpyDoc