GB_BROCHURE_SWG100 BIOGAS_4s_20140626.cdr

THE UNIQUE
ANALYZER
for Biogas, Biomethan, Landfill Gas, Coalbed Methane
Also for use in hazardous area
zone 2 according to
II 3G Ex nA IIA T1 Gc
The complete, ready to use
biogas analyzer SWG100 is the
industrial solution to be used
with:
biogas (anaerobic digestion) plants
cogeneration heat and power engines (CHP)
municipal or industrial waste water treatment sites
coal seam gas sites (coal bed methane)
food and animal waste processing plants
biomethan (gas to grid) plants
landfill sites
SWG100
Instrument main features are:
industry compatible rugged design for harsh industrial environment
standard system safety included with continuously monitored fan ventilation
of cabinet, gas flow restrictor orifice at gas inlet
optional use in hazardous area zone 2, with compliance certificate according to
II 3G Ex nA IIA T1 Gc
efficient sample gas preparation for fast and reliable measurements
sampling from low suction up to high pressure gas
no dilution of the sample gas, neither use of compressed air is required
direct and continuous/discontinuous measurement, with pressure and
temperature compensation and event data logging
up to 10 sites monitoring (time sharing technique) with only one analyzer
ready to run delivery, minimum installation work
SWG100 biogas
standard option
Basic analyzer for wall (rack) mounting, IP54 aluminum cabinet with
anti-corrosive red structural lacquer
Monitored ambient air ventilation with display and system alarm,
including flow restrictor orifice and cutoff gas supply solenoid valve
Sample gas pump and internal sample flow monitoring with display
and system alarm
Solenoid valve for auto-zero with ambient air
1/8” threads for all sample gas, zero gas and calibration gas inlets,
fittings for DN6/4 mm tube
3,5” TFT color, backlit display and keyboard, password protected operation
RS485 digital data transfer (Modbus RTU)
Universal 90 - 240 Vac / 47 - 63 Hz / 90 W power supply
CH4 and CO2 NDIR measurement
O2 measurement with long-life EC cell
H2S low measurement with EC cell protection (cut-off and purge)
H2S high measurement with EC cell
H2 or CO measurement with EC cell
Use in hazardous area zone 2, category II 3G Ex nA IIA T1 Gc
Combustible gas detector (%LEL) mounted inside analyzer cabinet
Electric gas cooler (Peltier) with automatic condensate draining pump
Auto-calibration using span gas mixture cylinder
Multiple sampling point switchover from 2x up to maximum 10x sites
Module with 4 channel analog outputs/inputs 4 - 20 mA and 2x alarm relays
Analyzer remote control using 4x external relay contacts
Converter module of RS485 into Profibus
Cabinet heater for freeze protection
THE UNIQUE
ANALYZER
for Biogas, Biomethan, Landfill Gas, Coalbed Methane
MRU biogas analyzer of series SWG100, are designed for use in the harsh industrial environment of different
sites where biogas is produced.
Due to the unique design, the analyzer complies to EN60079-15 and RL 94/9/EG norms and can optionally be
used in hazardous areas Zone 2, with manufacturer certificate of conformity according to
II 3G Ex nA IIA T1 Gc
The analyzer can be installed in outdoor or indoor location, can sample dry or wet biogas, pressurized or
low pressure gas and can be used from single point sampling up to max 10 sampling points.
Gas Cooler
Peltier type
Combustible gas detector
(%LEL)
Gas sampling pump
Up to 10x switching biogas inlets
(time sharing technique)
with fail-safe shut-off solenoid
valves and flow restrictor orifice
NDIR bench for
CH4 / CO2
measurement
Auto-Zero and
Auto-Cal
solenoid valves
EC cells for
O2 / H2S low /H2S high
with cut-off and purge
for H2S
Condensate
draining pump
Internal sample
flow monitoring
Continuous monitored
ventilation fan with alarm
Optional: cabinet heater
Universal power
supply 90 - 240 Vac
47 - 63 Hz / 90 W
Up to 10x modules with analog outputs
4x 4 - 20 mA , RS485 and
2x alarm relays
THE UNIQUE
ANALYZER
for Biogas, Biomethan, Landfill Gas, Coalbed Methane
TECHNICAL SPECIFICATIONS
Measured components
Measuring ranges
Measuring method
CH4:
CO2:
O2:
H2S low:
H2S high:
H2:
Calculated component
Calorific value: 0 – 50 MJ/m3; MJ/kg
HMI human machine interface
3,5” TFT color display
Backlit keyboard, password protected operation
4x analog output 4-20 mA, floating, max. load 500R
2 alarm relays, potential free contacts 24 Vdc/5 A
RS485 digital interface (Modbus RTU)
DIN-rail RS485 / ProfiBus converter
System safety components
Manufacturing compliance to
II 3G Ex nA IIA T1 Gc
Monitored cabinet ventilation fan
Stainless steel flow restrictor orifice
Sample gas shut-down solenoid valve
LEL (CH4) monitoring inside cabinet
Sample preparation
Stainless steel gas fittings with 1/8” ID threads
Electric gas cooler
Teflon particulate filter, internal Viton hosing
Monitored and regulated sample flow 40…60 l/h
Sample inlet pressure: -100 mbar to + 300 mbar
Sample venting: atmosphere pressure
Cabinet dimensions
Weight / Protection
600 x 600 x 210 mm (H x W x D) for wall or rack mounting
25kg / IP54
+5°C…+45°C or -20°C…+45°C with cabinet heater
Indoor or outdoor (rain and sun shade is mandatory user scope of supply)
Continuous, monitored fan ventilation
Cabinet heater 200 W (option)
Ambient temperature
Installation site
Cabinet conditioning
Power supply
0 – 100 % (NDIR)
0 – 100 % (NDIR)
0 – 25 % (electrochemical, continuous)
0 – 1000 ppm (electrochemical, discontinuous)
0 – 10.000 ppm (electrochemical, continuous)
0 – 1.000 ppm (electrochemical, discontinuous)
Universal 90 - 240 Vac / 47 - 63 Hz / 90 W (300 W with cabinet heater)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Simultaneous analysis of O2, CO2, CH4, H2S, NOx,
gas pressure and temperature,
with Li-Ion battery, SD card for data storage,
see more details and features on our website
MRU Measuring instruments for flue gases and environmental protection GmbH
Fuchshalde 8 + 12 • 74172 Neckarsulm - Obereisesheim
Phone +49 7132-99620 • [email protected] • www.mru.eu
W-65333GB-K1-XX-064
MRU portable biogas and flue gas analyzers for CHP engine: