You cannot download Flash but only read this

Preventa safety modules
XPSECPE
For extending the number of safety
contacts
Catalogue
june
2014
Operating principle,
references
Modules de sécurité Preventa
Type XPSECPE
For extending the number of safety contacts
Operating principle
1
Safety modules XPSECPE for extending the number of safety contacts, are available as additions to Preventa
XPSbase modules (Emergency stop, limit switch, two-hand control, etc.).
They are used to extend the number of safety output contacts of the base modules.
2
Maximum achievable safety level
bb PL e/Category 4 conforming to EN/ISO 13849-1
bb SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061 (when connected to the appropriate module)
Product certifications
bb UL
bb CSA
bb TÜV
3
References
Description
4
Safety modules for extending
the number of safety contacts,
for use with XPS base modules
5
Connection
Number of
safety
circuits
Additional
outputs
Supply
Reference
Captive screw
clamp terminals
Terminal block
removable from
module
8
1
a and
c 24 V
XPSECPE5131P
0.550/
1,213
Spring terminals 8
Terminal block
removable from
module
1
a and
c 24 V
XPSECPE5131C
0.650/
1.433
Captive screw
clamp terminals
Terminal block
removable from
module
8
1
a 115…230 V XPSECPE3910P
0.650/
1.433
Spring terminals 8
Terminal block
removable from
module
1
a 115…230 V XPSECPE3910C
0.650/
1.433
Weight
kg/
lb
XPSECPE5131P
6
7
XPSECPE5131C
8
9
10
2
38718-EN
version: 1.0
Modules de sécurité Preventa
Schemes
Type XPSECPE
For extending the number of safety contacts
Wiring diagram and Functional Diagram are available on the “e-Shop” via the
partnumber.
Operating principle,
references
Modules de sécurité Preventa
Type XPSECPE
For extending the number of safety contacts
2
Operating principle
1
Safety modules XPSECPE for extending the number of safety contacts, are available as additions to Preventa
XPSbase modules (Emergency stop, limit switch, two-hand control, etc.).
They are used to extend the number of safety output contacts of the base modules.
2
Maximum achievable safety level
b PLe/Category 4 conforming to EN/ISO 13849-1,
b SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061 (when connected to the appropriate module)
Click on a partnumber,
the hyperlink
Product certifications
opens the “e-Shop”
References
Description
4
Safety modules for extending
the number of safety contacts,
for use with XPSbase modules
5
XPSECPE5131P
Embedded hyperlinks
in catalogues
=
6
7
direct access to
information on the
internet
3
b UL
b CSA
b TÜV
3
1
XPSECPE5131C
Connection
Number of
safety
circuits
Additional
outputs
Supply
Reference
Captive screw
clamp terminals
Terminal block
removable from
module
8
1
a and
c 24 V
XPSECPE5131P
0.550/
1,213
Spring terminals 8
Terminal block
removable from
module
1
a and
c 24 V
XPSECPE5131C
0.650/
1.433
Captive screw
clamp terminals
Terminal block
removable from
module
8
1
a 115…230 V XPSECPE3910P
0.650/
1.433
Spring terminals 8
Terminal block
removable from
module
1
a 115…230 V XPSECPE3910C
0.650/
1.433
Weight
kg/
lb
4
5
Click on “Documents & Download”
8
6
9
10
2
XPSECPE-GB
version: 1.0
XPS-ECPE
Schéma de câblage de XPS-ECPE
Wiring diagram for XPS-ECPE
Anschlußplan für XPS-ECPE
L(+)
7
F1
(2)
13
23
14
24
XPS
Base module
Y1
Y2
S1 =
Bouton marche
Start Button
Starttaste
(1)
F2
(2)
S1
A1
A2
S12
S11
SUPPLY
+ -
S32
CH1
K1
CH2
K2
F3
(2)
F4
(2)
F5
(2)
F6
(2)
F7
(2)
F8
(2)
F9
(2)
Y1
13
23
33
43
53
63
73
83
91
Y2
14
24
34
44
54
64
74
84
92
(1) =
Boucle de retour
Feedback circuit
Rückführkreis
(2) =
Voir caractéristiques
techniques pour le calibre
maximal des fusibles.
See Technical Data for
maximum fuse sizes.
Siehe technische Daten für
maximale Sicherungsgröße.
XPS-ECPE
S21
Y03
Y04
S22
8
Click on “Instruction sheet”
Groupe de sortie 2
Groupe de sortie 1
Release group 2
Release group 1
Freigabegruppe 2
Freigabegruppe 1
Sorties de sécurité
Safety outputs
Sicherheitsausgänge
N (–)
Installation 1 … 6
1
13
4
XPS module de base
XPS Base module
XPS Basisgerät
XPS module de base, par ex. ESPE type 4
XPS Base module, e.g.ESPE type 4
XPS Basisgerät, z.B. BWS Typ 4
OSSD
14
S11
S12
Monocanal
Single-channel
Einkanalig
2
S32
S21
S12
S22
S32
S21
S22
Bicanal via OSSD (ESPE)
Two-channel via OSSD (ESPE)
Zweikanalig über OSSD (BWS)
13
14
23
XPS module de base
XPS Base module
XPS Basisgerät
5
Y1
Y2
Y1
Y2
24
S22
S11
S32
S12
S21
Bi-canal avec détection de courts-circuits transversaux
Two-channel with crossover detection
Zweikanalig mit Querschlusserkennung
Boucle de retour
Feedback circuit
Rückführkreis
3
6
13
23
14
24
XPS module de base
XPS Base module
XPS Basisgerät
S1
XPS module de base
XPS Base module
XPS Basisgerät
S22
S11
S12
S32
S21
Bi-canal sans détection de courts-circuits transversaux
Two-channel without crossover detection
Zweikanalig ohne Querschlusserkennung
24 V
PLC
Y03
Y04
9
Circuit de signalisation
Reporting circuit
Meldekreis
7 / 12
10
38718-EN
version: 1.0
3
More information on
http://www.schneider-electric.com/machinesafety
Schneider Electric Industries SAS
Head Office
35, rue Joseph Monier
F-92500 Rueil-Malmaison
France
The information provided in this documentation contains general descriptions and/or technical
characteristics of the performance of the products contained herein. This documentation is not
intended as a substitute for and is not to be used for determining suitability or reliability of these
products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.
Design: Schneider Electric
Photos: Schneider Electric