Housing and Plaster Plate
General Information
Fixture must be installed by a qualified electrician (check
with local and national codes for proper installation). To
prevent electrical shock, disconnect electrical supply
4 5/8”
(117mm)
before installation or servicing. Compatible only with
traditional, level 5 surface finishing, not self-leveling, PVA
primer systems. Not for use in wood or tile ceilings.
4 3/4”
(120mm)
WORKFLOW CHART
15 3/4”
(400mm)
7 1/8”
(180mm)
9 1/4”
(235 mm)
ELECTRICAL CONTRACTOR
1. Locate and mount housing
2. Screw and lock-in housing
3. Connect wires in housing
DRYWALL CONTRACTOR
1. Install and cut drywall
around housing.
Genna Trim and LED Module
ELECTRICAL CONTRACTOR
1. Adjust plaster flange frame
and tighten wing nuts.
2. Screw plaster plate into housing.
DRYWALL CONTRACTOR
1. Plaster, sand & paint.
2. Clean aperture with
clean damp towel.
ELECTRICAL CONTRACTOR
1. Clean aperture with clean damp towel,
where the drywall contractor missed.
2. Connect LED module wiring to housing
power supply.
3. Install trim to housing.
1
ELECTRICAL CONTRACTOR
A
DRYWALL
ANCHOR
SCREENS
B
5 7/8"
(149mm)
14 3/4"
(375mm)
ALIGNMENT
NOTCH
8 7/8"
(226mm)
1
2
NOTE: APERTURE
IS CENTERED WITH
CURVES IN HOUSING.
(NOT CENTER IN FIXTURE)
NOTE: APERTURE
IS CENTERED WITH
CURVES IN HOUSING.
12 1/8"
(308mm)
2
MUST BE FLUSH
WITH JOIST
ALIGNMENT
NOTCH
1: Use these dimensions when locating the center point of
the aperture during the installation process. Align the
fixture using a laser or a chalk line.
2: Hanger bars must align and remain flush with joist.
NOTE: Drywall anchor screens may be removed,
if the joist are less than 14 1/2" apart. Refer to
page 7 to shorten the hanger bars,
C
D
4
REMODEL NOTE: CUT
DRYWALL TO MIDDLE
OF JOIST.
3
4: After installation, pull on fixture to ensure there is no
movement.
3: After fixture is positioned, tighten all (10) screws on
hanger bars.
2
ELECTRICAL CONTRACTOR
E
INSIDE GENNA JUNCTION BOX
(NOT TO SCALE)
ELV DIMMER
WHITE (NEUTRAL)
Neutral
INPUT
HOT
GND
Hot
TO NEXT FIXTURE
(FOR BRANCH WIRING)
BLACK (HOT)
*NOTE*
Leave 12" of wire in the
junction box for future
maintenance through
the f ixture aperture.
INSIDE GENNA
FIXTURE
Hot
Neutral
CONSTANT
CURRENT
POWER
SUPPLY
WIRING DIAGRAM
FOR USE WITH PURE LIGHTING GENNA LED FIXTURES
3
ELECTRICAL CONTRACTOR
DRYWALL CONTRACTOR
F
G
Contratista hojas de pared tiene
que instalar la hoja de pared y
corte un aqujero 14 3/4"
(375mm) X 12 1/8" (308mm) con
une corte rotatorio alrededor el
enseres fijo o lo corte un agujero
antes que instalar.
DRYWALL
ANCHOR
SCREEN
CUTOUT
5
6
DRYWALL
ROTARY TOOL
DRYWALL
ANCHOR
SCREW
5: Drywall contractor must install drywall and cut 14 3/4"
(375mm) X 12 1/8" (308mm) hole with rotary cutting tool
around fixture or pre-cut hole in drywall prior to
installation.
6: Electrian must anchor drywall anchor screens. Insert
screws through drywall into anchor screen on fixture.
H
I
CEILING
7
PLASTER
FLANGE
FRAME
LOOSEN WINGNUTS TO
ADJUST PLASTER FLANGE
FRAME
8
7: Loosen (4) wing nuts and adjust plaster flange frame to
be flush with drywall. All 4 corners MUST be exactly even
with drywall. Plaster flange frame adjusts to
accommodate 1/2" (13mm) to 1 1/4" (32mm) ceiling
thickness.
8: Use a straight edge or level and move plaster flange
frame up or down to be exactly even with drywall ceiling.
4
ELECTRICAL CONTRACTOR
J
K
TIGHTEN WINGNUTS TO
ADJUST PLASTER FLANGE
FRAME
CEILING
9
PLASTER
PLATE
10
PAINT
SHIELD
SCREW(4x)
9
10: Loosely attach plaster plate using all (4) screws. After all
(4) screws are started, go back and tighten the screws
securely.
9: Tighten (4) wing nuts securely.
DRYWALL CONTRACTOR
Compatible only with traditional, level 5 surface
finishing, not self-leveling, PVA primer systems.
L
M
HOUSING
CEILING
DRYWALL
TAPE
22
Aplicar incluido Perfect Finish
FibaTape Ultra-Thin Tape
alrededer de los cuatro lados
CEILING
11
12: Apply included Perfect Finish FibaTape Ultra-Thin
Drywall Tape around all four sides of the plaster plate.
DO NOT OVERLAP.
11: Check to ensure that the plaster plate is flush and even
with the drywall.
5
N
O
CEILING
13
CEILING
14
PLASTER
PLATE
PLASTER
PLATE
PAINT
SHIELD
PAINT
SHIELD
Aplique una capa delgada de
Durabond 45 compuesto
alrededor de todo cuatro lados de
la placa de yeso
Aplique una capa delgada de
Durabond 45 compuesto
alrededor de todo cuatro lados de
la placa de yeso
13: Apply a thin layer of Durabond 45 compound around all
four sides of the plaster plate.
P
14: Sand plastered surface. Repeat as needed until
surface is completely smooth before painting.
ELECTRICAL CONTRACTOR
CEILING
Q
15
PLASTER
PLATE
17
CEILING
WIRE
NUTS
PAINT
SHIELD
18
LED
MODULE
15: Paint and finish plaster plate and wall. Remove paint
shield from plaster plate 20-60 minutes after painting.
17: Connect the red wire from the LED power supply to the
red wire of the LED module using a wire nut.
16: Clean all excess paint from the aperture.
18: Connect the blue wire from the LED power supply to
the black wire of the LED module using a wire nut.
R
19
HOUSING
OPENING
19
ENSURE TRIM
IS FULLY SEATED
IN HOUSING
LED
MODULE
19: Place all electrical connections into the mounting box. Insert trim into plaster plate, tilt, and secure back edge. Push trim into
plaster plate and ensure it snaps in and fits flush with the ceiling.
6
SHORTENING THE HANGER BAR (ONLY FOR
JOISTS SPACED LESS THAN 14.5")
T
U
HOUSING
HOUSING
HANGER ARM
HANGER ARM
1
1
2
1
2
3
HANGER ARM
1
DRYWALL
ANCHOR SCREEN
3
PHILLIPS SCREW
1: Remove the four Phillip screws on the housing to remove
the two anchor screens, and put the screws back on.
2: Pull the hanger arms completely out of the housing.
3: Break the ends completely off hanger arms.
V
HOUSING
HANGER
ARM
4
4
4: Insert the hanger arms back into the housing, and
continue to step A on page 2 to complete instillation.
7