FWH series ® 8/14 Fire Wall Hangers STRUCTURAL CONNECTORS The FWH Fire Wall Hanger series is the best solution for attaching floor framing to fire rated walls in wood frame construction. The advanced design allows the installation of the FWH before the drywall is attached and permits the building project to be completely framed-up, and weather-tight before the drywall sheathing work starts. Features: Direct load transfer to the face of the wall framing Hanger web accommodates 2-plies of 5/8" drywall Supports full table loads without drywall in place Allows clear access for all the construction trades without drywall interference Driving points easily mark slot locations on drywall without measuring FWH-T Fire Wall Hanger Template easily guides the drywall cutting tool to simplify the slot cutting 2 1/4" Materials: 14 gauge Finish: U SP Primer; FWH-T – G90 galvanizing Options: S ee Specialty Options chart Codes: Factored resistances are derived from data submitted to various North American building code evaluators. Patents: Pending 2" FWH Typical FWH floor truss installation FWH Side View Typical FWH drywall installation using FWH-T Template Installation: • Use all specified fasteners. • Install the face of hanger flanges tight to stud wall framing. • For proper installation, the end of the truss/joist should be 1-5/8” from the face of the stud wall framing as shown in the Typical FWH drywall installation figure resulting in a gap between the end of the truss/joist and hanger no greater than 1/8". • To achieve tabulated loads, the gap between the truss and hanger should not exceed 1/8". • Drywall Installation - Use the FWH-T template to slot cut the gypsum board. See FWH-T Template Sequence below. Slide the drywall into position and fasten to the framing members. 5 ¾" Edge Prong 8" 13" USP supplies quality products to build Stronger Safer Structures Customer Service: Burnsville, MN Phone: 1-800-328-5934 1-952-898-8772 Fax: 1-952-898-8605 Manufacturing: Montgomery, MN Livermore, CA Largo, FL Thornhill, Ontario Warehouses: Humble, TX Corona, CA Westampton, NJ www.USPconnectors.com Corner Prong 1.) Align the FWH-Template slot with the mark in the drywall and engage the prongs into edge of drywall FWH-T Template 3.) Run the drywall cutter down the template to cut the slot 2.) Rotate the template and press down on the end to engage the corner prongs FWH-T Template Sequence Dimensions (in)3 Fastener Schedule2 Header USP Stock No. FWH3514 FWH3516 FWH3518 FWH3520 FWH-T Steel Ref. No. W H Qty Type Qty Gauge DHU3.56/14TF 14 3-9/16 13-15/16 6 10d 6 DHU3.56/16TF 14 3-9/16 15-15/16 6 10d 6 DHU3.56/18TF 14 3-9/16 17-15/16 6 10d 6 DHU3.56/20TF 14 3-9/16 19-15/16 6 10d 6 -- -16 5-3/4 13 -- -- -- -- -- -- Joist Type 10d x 1-1/2 10d x 1-1/2 10d x 1-1/2 10d x 1-1/2 -- -- Factored Resistance DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN) Vertical Uplift1 Vertical Uplift1 Vertical Uplift1 Vertical Uplift1 Ctn 100% 115% 100% 115% 100% 115% 100% 115% Qty 3660 360 16.28 1.60 3125 305 13.90 1.36 3660 360 16.28 1.60 3125 305 13.90 1.36 4 3660 360 16.28 1.60 3125 305 13.90 1.36 3660 360 16.28 1.60 3125 305 13.90 1.36 -- --- --- --- --- --- --- --- -1 1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed. 2) NAILS: 10d x 1-1/2˝ nails are 0.148˝ dia. x 1-1/2˝ long, 10d nails are 0.148˝ dia. x 3˝ long. 3) Other sizes are available. Contact USP Structural Connectors for additional information. 2 Hour Fire-Rating Specialty Options Chart Option Skewed1 Range 1˚ to 45˚ Factored Resistance 80% of table load Ordering Add SK, angle required, and right (R) or left (L), to product number. Ex. FWH3514-SK45R FWH hangers are tested per ASTM E814 standards. The test report states “When installed on one side of a maximum 2 hour fire-rated wall assembly, the penetration of the USP FWH Fire Wall Hanger through the gypsum board will not reduce the fire resistive rating of the 2 hour fire resistive assembly.” 1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange. Revised August 2014 USP2317-141
© Copyright 2025 ExpyDoc