TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER Models : 601, 741, 901 ACVIA - Cooling only (Compact) CCVIA / ECVIA - Cooling only (Split) ACVIBA - Heat Pump (Compact) CCVIBA / ECVIBA - Heat Pump (Split) 12.13 Ref.207378 Rev.100 Thank you for trust in HITECSA Product. From our company we are offering to the market, for more than 30 years, an extended range of specialized units for air conditioning and cooling installations. Our approach is based in efficiency, flexibility, manageability and practical solutions. It has built a hallmark of our product catalogue. The versatility of our factories allows us to contribute solutions almost customitzables in each project, searching a solution for every problem that arises in design and implementation of air conditioning installations. From Hiplus Aire Acondicionado’s team, once more thank you very much. 2 de 24 12.13 Ref.207378 Rev.100 SUMMARY PAGE KEY POINTS AND PRESENTATION 4 GENERAL SPECIFICATIONS 5 REFRIGERATOR DIAGRAMS 7 TECHNICAL DATA 9 DIMENSIONS 13 AIRFLOW AND STATIC PRESSURE (EVAPORATOR side) 19 AIRFLOW AND STATIC PRESSURE (CONDENSER side) 21 REMOTE CONTROL AND OPTIONALS 23 Visit our web page and sign in to obtain technical documentation of this units and the rest of Hitecsa product range www.hitecsa.com 3 de 24 12.13 Ref.207378 Rev.100 KEY POINTS - Optimized design for an easy access to the components - Exchangeable covers for configure in action supply and return air - DC inverter technology: maximum safe and comfort máximo ahorro y confort - Cooling capacities from 4 until 28 kW - Maximum adaptability to request - Low sound level - High performance in heat pump mode for low outdoor temperatures PRESENTATION - Air-air self-contained range has been checked and optimised to adapt itself the current demand of energy efficiency and environment protection. The introduction of ecological gas R410A, DC inverter technology, available extension of cooling capacities and the optionals long list are some examples of the units improvements. - DC inverter technology adapt the compressor speed to needs at every moment, allowing only the necessary energy consuming and drastically reduce consumption. 4 de 24 12.13 Ref.207378 Rev.100 CARACTERÍSTICAS GENERALES DESCRIPCIÓN The equiment constitute fot series CCVIA/ECVIA CCVIBA/ECVIBA are vertical air conditioner in split contruction being the first cooling only and the second one made with heat pump. In parallel and compact contruction ACVIA-ACVIBA are available, they are also for cooling only and heat pump versions. All these equipments are suitable to work connected in a net of air distribution pipe as much in indoor section as in outdoor section. CABINET Made in galvanized steel plate, completed with polyester resins, polymerized in the oven, excellent resistance to corrosion and in outdoors. The assembly is wrapped with thermoacustic insulation. COMPRESSORS Type scroll. Type motor: BLDC. Number of poles: 6 Supply: Triphase Brushless motor is formed for a stator and a rotor with permanent magneto. It shows a higher efficiency respect to induction motors because no exist magnetizing current losses in the rotor. AIR FILTER Polyurethane foam, washable, 10 mm thick crosslinked S-20 with high efficiency filtration FANS Centrifuge type. Supply by frecuency converter Changeable airflow in condenser. Three kind of airflows in evaporator (low, medium and maximum speed. Possivility in Evaporator of increase or reduce Diponible Pressure. COOLING CIRCUIT - Built in special copper tube for refrigeration, dehydrated, incorporating drying filter and check valve with an easy acces for verification and charge. - Equip suction accumulator on the compressor suction line, protect it from liquid bumps - In split models, oil separator is included - Reversing Valve to cycle invertion by solenoid (230V) in Heat Pump models. - Unidirectional Valves - The welds between the different elements are executed with copper-silver alloy. EXCHANGERS Built in aluminum fins (fin step 2,1 mm) and copper pipe mechanically expanded of 3/8", high exchange efficiency. EXPANSION DEVICE As much in compact models as divide models are equipped with Electronic Expnsion Valves. In compact models is mounted only one Expansion Valve while divide models incorporate one for each section. For divide models, altought their assembly is formed for two Electronic Expansion Valves only regulates only for section whose exchanger is evaporating, remaining fully open the other valve. 5 de 24 12.13 Ref.207378 Rev.100 GENERAL SPECIFICATIONS MANEUVER AND CONTROL EQUIPMENT Each unit is available of control and safety devices of shown below: OPTIONALS - Environment thermostat to 230 Volts AC. monophase - Hot water heating coil. - Protection magnetothermals for compressor, fans and general maneuver - Compressor sound jacket - Thermal protection of all triphase motors. - Speed regulator for fan motor of outdoor side (as much Cooling as Heat Pump) - High Pressure Presostat - System defrost pressure control performance according to predetermined time periods. - Reversible valve activated by solenoid to 230V - Remote connection ON-OFF and COOL-HEAT. - ALARM indication. - Heating coil for electrical heating as single support in defrost maneuver. - Anti-corrosion pre-treated coils. Treatment blue fin. - Free-cooling. Damper system activated by servomotor to use outdoor conditions as climatization mode for indoor section. - Outdoor installation kit. - Anti-freeze resistance operation collection in tray - High efficiency filters G4 and F6-F8 - Upgraded motor. Available pressure increase in condenser and evaporator section - Air filter in condenser - Schrader Valves for pressure test - Scheduling function and Modbus connection POWER SUPPLY Thermostat: 230.I.50 Hz~ 601, 741 and 901 models: 401.III+N.50Hz ~. For other supplies consult availability OPERATION LIMITS 6 de 24 12.13 Ref.207378 Rev.100 REFRIGERATOR DIAGRAMS REFRIGERATOR DIAGRAM (COMPACT) 1. Four-way reverse cycle valve 2. Outdoor fan 3. Check valve 4. Filter 5. Expansion valve 6. Suction acumulator 7. Ball valve 8. Compressor TE Outdoor air temperature TI Indoor air temperature B1 Discharge temperature B6 Suction pressure B7 Discharge pressure B4 Reheating temperature 7 de 24 12.13 Ref.207378 Rev.100 REFRIGERATOR DIAGRAMS REFRIGERATOR DIAGRAM (SPLIT) 1. Four-way reverse cycle valve 2. Outdoor fan 3. Expansion valve 4. Check valve 5. Filter 6. Service key 7. Suction acumulator 8. Compressor 9. Service valve 10. Silencer 11. Oil separator TE Outdoor air temperature TI Indoor air temperature B1 Discharge temperature B6 Suction pressure B7 Discharge pressure B4 Reheating temperature 8 de 24 12.13 Ref.207378 Rev.100 TECHNICAL DATA ACVIA - ACVIBA ACVIA ACVIBA CAPACITIES Cooling capacity (20 - 80 - 120 Hz) Heating capacity (20 - 80 - 120 Hz) EER (40 - 80 - 90 Hz) COP (40 - 80 - 90 Hz) Number of refrigerant circuits REFRIGERANT Type Global warming potential Baseload COMPRESSOR Type Number Oil type Oil volume 601 741 901 4,0 - 13,8 - 18,5 4,2 - 13,9 - 19,8 2.90 - 2.60- 2.50 2.95 - 2.62 - 2.52 1 5,2 - 17,7-23,9 4,5 - 17,8 - 25,8 2.86 - 2.56 - 2.45 2.94 - 2.69 - 2.55 1 6,5 - 22,0 - 28,3 7,0 - 22,2 - 30,2 2.96 - 2.54 - 2.44 2.99 - 2.64 - 2.54 1 Kg 6,5 R-410A 1725 7,5 9,5 l 1 FV50S (PVE) 1,4 SCROLL DC INVERTER 1 FV50S (PVE) 1,7 1 FV50S (PVE) 2,3 m2 mm " 0,711 2,1 3/8 0,711 2,1 3/8 1,112 2,1 3/8 V kW 15/15 SS 400/3/50 1,1 Pulleys DOUBLE SUCTION CENTRIFUGAL 15/15 SS 400/3/50 1,5 Pulleys 15/11 G2L 400/3/50 2,2 Pulleys m3/h Pa r.p.m. 5.600 50 740 7.300 50 830 10.000 50 688 m2 mm " 0,540 2,1 3/8 kW kW OUTDOOR EXCHANGER Type Frontal surface Space fin Piping diameter OUTDOOR FAN Type Model Voltage Motor capacity Transmission speed Nominal air flow Available static pressure Maximum fan speed Aluminium fins and copper tubing INDOOR EXCHANGER Type Frontal surface Space fin Piping diameter INDOOR FAN Type Model Voltage Motor capacity Transmission speed Air flows (Low / Medium / High) Available static pressure Higher flow Maximum fan speed Aluminium fins and copper tubing V kW m3/h Pa r.p.m. 12/12 SS 400/3/50 0,75 Pulleys 2.700/3.200/4.000 70 760 9 de 24 0,540 2,1 3/8 0,738 2,1 3/8 DOUBLE SUCTION CENTRIFUGAL 12/12 SS 12/12 G2L 400/3/50 400/3/50 1,1 1,1 Pulleys Pulleys 3.200/3.800/4.800 3.900/4.650/5.900 75 90 906 806 12.13 Ref.207378 Rev.100 TECHNICAL DATA ACVIA - ACVIBA ACVIA ACVIBA 601 741 901 400/3/50 + N 6,9 11,0 6,3 11,0 12,0 19,0 11,3 18,5 8,6 14,5 8,4 13,5 14,9 25,4 14,3 23,5 NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kW 5,4 6,9 Current input (Cooling only) A 8,6 11,0 Indoor airflow m3/h 2.700 3.200 8,6 14,5 3.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) Power Supply V 400/3/50 + N Power input (Heating) kW 4,9 6,3 Current input (Heating) A 8,3 11,0 Indoor airflow m3/h 3.200 3.800 8,4 13,5 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kW 9,2 12,0 Current input (Cooling only) A 15,0 19,0 Indoor airflow m3/h 3.200 3.800 14,9 25,4 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) Power Supply V 400/3/50 + N Power input (Heating) kW 8,7 11,3 Current input (Heating) A 14,3 18,5 Indoor airflow m3/h 4.000 4.800 14,3 23,5 5.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR STANDARD CONDITIONS Power supply V Power input (Cooling only) kW 5,4 Current input (Cooling only) A 8,6 Power input (Heating) kW 4,9 Current input (Heating) A 8,3 Maximum Power Input (Cooling only) kW 9,2 Maximum Current Input (Cooling only) A 15,0 Maximum Power Input (Heating) kW 8,7 Maximum Current Input (Heating) A 14,3 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: High 10 de 24 12.13 Ref.207378 Rev.100 TECHNICAL DATA CCVIA - CCVIBA CCVIA CCVIBA CAPACITIES Cooling capacity (20 - 80 - 120 Hz) Heating capacity (20 - 80 - 120 Hz) EER (40 - 80 - 90 Hz) COP (40 - 80 - 90 Hz) Number of refrigerant circuits REFRIGERANT Type Global warming potential Cooling liquid connection Cooling gas connection Base load COMPRESSOR Type Number Oil type Oil volume OUTDOOR EXCHANGER Type Frontal surface Space fin Piping diameter OUTDOOR FAN Type Model Voltage Motor capacity Transmission speed Nominal air flow Available static pressure Maximum fan speed 601 741 901 4,0 - 13,8 - 18,5 4,2 - 13,9 - 19,8 2.90 - 2.60- 2.50 2.95 - 2.62 - 2.52 1 5,2 - 17,7-23,9 4,5 - 17,8 - 25,8 2.86 - 2.56 - 2.45 2.94 - 2.69 - 2.55 1 6,5 - 22,0 - 28,3 7,0 - 22,2 - 30,2 2.96 - 2.54 - 2.44 2.99 - 2.64 - 2.54 1 " " Kg 1/2 7/8 6,5 R-410A 1725 5/8 1 1/8 7,5 5/8 1 1/8 9,5 l 1,000 FV50S (PVE) 1,4 SCROLL DC INVERTER 1 FV50S (PVE) 1,7 1 FV50S (PVE) 2,3 m2 mm " 0,711 2,1 3/8 Aluminium fins and copper tubing 0,711 2,1 3/8 1,112 2,1 3/8 15/15 SS 400/3/50 1,1 Poleas 5.600 50 740 DOUBLE SUCTION CENTRIFUGAL 15/15 SS 400/3/50 1,5 Poleas 7.300 50 830 15/11 G2L 400/3/50 2,2 Poleas 10.000 50 688 kW kW V kW m3/h Pa r.p.m. NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kW 4,9 6,3 Current input (Cooling only) A 7,9 10,1 Indoor airflow m3/h 2.700 3.200 7,9 13,4 3.900 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) Power Supply V 400/3/50 + N Power input (Heating) kW 4,3 5,6 Current input (Heating) A 7,3 9,8 Indoor airflow m3/h 3.200 3.800 7,4 11,9 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kW 8,6 11,3 Current input (Cooling only) A 14,1 17,9 Indoor airflow m3/h 3.200 3.800 13,9 23,7 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) Power Supply 400/3/50 + N Power input (Heating) kW 7,4 9,8 Current input (Heating) A 12,2 16,1 Indoor airflow m3/h 4.000 4.800 12,6 20,8 5.900 DIMENSIONS AND WEIGHT Lenght Width Height Weight 1700 870 1250 390 mm mm mm Kg 1130 800 1250 260 1130 800 1250 320 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: High 11 de 24 12.13 Ref.207378 Rev.100 TECHNICAL DATA ECVIA - ECVIBA ECVIA STD ECVIBA STD CAPACITIES Cooling capacity (20 - 80 - 120 Hz) Heating capacity (20 - 80 - 120 Hz) EER (40 - 80 - 90 Hz) COP (40 - 80 - 90 Hz) Number of refrigerant circuits REFRIGERANT Type Global warming potential Cooling liquid connection Cooling gas connection 601 741 901 4,0 - 13,8 - 18,5 4,2 - 13,9 - 19,8 2.90 - 2.60- 2.50 2.95 - 2.62 - 2.52 1 5,2 - 17,7-23,9 4,5 - 17,8 - 25,8 2.86 - 2.56 - 2.45 2.94 - 2.69 - 2.55 1 6,5 - 22,0 - 28,3 7,0 - 22,2 - 30,2 2.96 - 2.54 - 2.44 2.99 - 2.64 - 2.54 1 " " 1/2 7/8 R-410A 1725 5/8 1 1/8 5/8 1 1/8 m2 mm " 0,540 2,1 3/8 0,540 2,1 3/8 0,738 2,1 3/8 V kW 12/12 SS 400/3/50 0,75 Pulleys DOUBLE SUCTION CENTRIFUGAL 12/12 SS 400/3/50 1,1 Pulleys 12/12 G2L 400/3/50 1,1 Pulleys m3/h Pa r.p.m. 2.700/3.200/4.000 70 760 3.200/3.800/4.800 75 906 3.900/4.650/5.900 90 806 kW kW INDOOR EXCHANGER Type Frontal Surface Space fin Piping Diameter INDOOR FAN Type Model Voltage Motor capacity Transmission speed Air flows (Low / Medium / High) Available static pressure Higher flow Maximum fan speed Aluminium fins and copper tubing NOMINAL ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (1) Power Supply V 400/3/50 + N Power input (Cooling only) kW 0,5 0,6 Current input (Cooling only) A 1,0 1,2 Indoor airflow m3/h 2.700 3.200 NOMINAL ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (2) 400/3/50 + N Power Supply V Power input (Heating) kW 0,6 0,7 Current input (Heating) A 1,2 1,6 Indoor airflow m3/h 3.200 3.800 0,7 1,6 3.900 1,0 2,3 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR COOLING STANDARD CONDITIONS (3) Power Supply V 400/3/50 + N Power input (Cooling only) kW 0,6 0,7 Current input (Cooling only) A 1,2 1,5 Indoor airflow m3/h 3.200 3.800 1,0 2,3 4.650 MAXIMUM ELECTRICAL SPECIFICATIONS FOR HEATING STANDARD CONDITIONS (4) 400/3/50 + N Power Supply Power input (Heating) kW 1,3 1,5 Current input (Heating) A 2,0 2,4 4.000 4.800 Indoor airflow m3/h 1,7 2,8 5.900 DIMENSIONS AND WEIGHT Lenght Width Height Weight 1700 870 650 210 mm mm mm Kg 1130 800 650 140 1130 800 650 150 (1) Cooling: Compressor frecuency: 80Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Low. (2) Heating: Compressor frecuency: 80Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: Medium. (3) Cooling maximum: Compressor frecuency: 120Hz. Outdoor dry temperature: 35 °C. Indoor Dry / Wet air temperature: 27ºC / 19 °C. Indoor airflow: Medium (4) Heating maximum: Compressor frecuency: 120Hz. Outdoor dry /wet airtemperature: 7ºC / 6 °C. Indoor dry temperature: 20 °C. Indoor airflow: High 12 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. AIR FILTER 2. CONDENSER COIL 3. CONDENTSER TURBINE 4. CONDENSER TURBINE MOTOR 5. COMPRESSOR 6. POWER SUPPLY INPUT 7. EVAPORATOR COIL 8. ELECTRICAL PANEL 9. EVAPORATOR TURBINE MOTOR 10. EVAPORATOR TURBINE 11. DRAINAGE 3/4" DIMENSIONS ACVIA-ACVIBA 601 - 741 13 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. AIR FILTER 2. CONDENSER COIL 3. CONDENSER TURBINE 4. CONDENSER TURBINE MOTOR 5. COMPRESSOR 6. POWER SUPPLY INPUT 7. EVAPORATOR COIL 8. ELECTRICAL PANEL 9. EVPORATOR TURBINE MOTOR 10. EVAPORATOR TURBINE 11. DRAINAGE 3/4" DIMENSIONS ACVIA-ACVIBA 901 14 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. AIR FILTER 2. OUTDOOR DRAINAGE 3/4" 3. POWER SUPPLY 4. INDOOR COIL 5. INDOOR FAN MOTOR 6. INDOOR FAN 7. COOLING CONNECTIONS 8. ELECTRICAL PANEL DIMENSIONS ECVIA-ECVIBA 601-741 15 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. AIR FILTER 2. INDOOR EXCHANGER 3. INDOOR DRAINAGE 3/4" 4. INDOOR FAN 5. INDOOR FAN MOTOR 6. GAS LINE 7. LIQUID LINE 8. POWER SUPPLY 9. ELECTRICAL PANEL DIMENSIONS ECVIA-ECVIBA 901 16 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. ELECTRICAL PANEL 2. OUTDOOR DRAINAGE 3. COMPRESSOR 4. MAIN-ON OFF SWITCH 5. POWER SUPPLY 6. OUTDOOR COIL 7. OUTDOOR MOTOR FAN 8. OUTDOOR FAN 9. COOLING CONNECTIONS DIMENSIONS CCVIA-CCVIBA 601 - 741 17 de 24 12.13 Ref.207378 Rev.100 CONSTRUCTION DETAILS 1. CONDENSER TURBINE 2. CONDENSER TURBINE MOTOR 3. CONDENSER COIL 4. COMPRESSOR 5. POWER SUPPLY INPUT 6. DRAINAGE 3/4" 7. ELECTRICAL PANEL 8. MAIN ON-OFF SWITCH DIMENSIONS CCVIA - CCVIBA 901 18 de 24 12.13 Ref.207378 Rev.100 AIRFLOW AND STATIC PRESSURE (EVAPORATOR SIDE) ECVIBA 601 Nominal Flow High Medium Low 100 90 80 Available Pressure (Pa) 70 60 50 40 30 20 10 0 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 Air flow (m3/h) ECVIBA 741 Nominal Flow High Medium Low 120 110 100 Available pressure (Pa) 90 80 70 60 50 40 30 20 10 0 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 Air flow (m3/h) 19 de 24 12.13 Ref.207378 Rev.100 AIRFLOW AND STATIC PRESSURE (EVAPORATOR SIDE) ECVIBA 901 Nominal flow High Medium Low 120 110 100 Available pressure (Pa) 90 80 70 60 50 40 30 20 10 0 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Airflow (m3/h) 20 de 24 12.13 Ref.207378 Rev.100 AIRFLOWS AND STATIC PRESSURE (CONDENSER SIDE) CCVIBA 601 Nominal Airflow 100% 70% 160 140 Available Pressure (Pa) 120 100 80 60 40 20 0 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 Air flow (m3/h) CCVIBA 741 Nominal flow 100% 70% 180 160 Available Pressure (Pa) 140 120 100 80 60 40 20 0 3600 4100 4600 5100 5600 6100 6600 7100 7600 8100 8600 9100 9600 Air flow (m3/h) 21 de 24 12.13 Ref.207378 Rev.100 AIRFLOWS AND STATIC PRESSURE (CONDENSER SIDE) Nominal Flow 100% 70% CCVIBA 901 140 Available Pressure (Pa) 120 100 80 60 40 20 0 3600 4600 5600 6600 7600 8600 9600 10600 11600 Air flow (m3/h) 22 de 24 12.13 Ref.207378 Rev.100 REMOTE CONTROL DC inverter self-contained range (compact and split) uses TH Tune remoted control. In this control is displayed: - Cooling / Heating mode - Temperature control (environmental / return) - Outdoor temperature By icons, we can see the compressor and outdoor fan operation. Indoor fan speed (high, medium or low) can be fixed for the user although is recommended set in automatic mode. In case of alarm or maintenance, this control informs us through codes of action to follow. OPTIONALS WALL PROBE If you prefer control temperature with environmental probe, is recommended use DPWT01100 wall probe. This optional allows control indoor stable temperature, so records a temperature value in zone control. Generally it is advisable to install a close apposition to where the Tune TH control is mounted. ELECTRIC RESISTANCE COIL FOR AUXILIARY ELECTRICAL HEATING DURING DEFROST These coils are formed for finned elements mounted in steel plate frame. They incorporate protector thermostat, actuating contactors and terminal strip for wiring. Mounted in suction. Model 601 Capacity kW Voltage Current Input V A 6 9 741 9 13 901 6 9 12 9 12 15 9 400/3/50 13 17 13 17 22 Consult for other capacities. FREE COOLING Consult. 23 de 24 12.13 Ref.207378 Rev.100 Masia Torrents, 2 08800 Vilanova i la Geltrú (Barcelona) España Tel. 93 893 49 12 Fax. 93 893 96 15 [email protected] www.hitecsa.com 12.13 Ref.207378 Rev.100 Reserved the right to make changes without previous notice.
© Copyright 2024 ExpyDoc