ESMRMB Hands-On MRI course on Advanced Neuroimaging (fMRI-DTI-Perfusion) September 18-20, 2014 European Center of Health Otwock (ECZ) (MR Site, Training Center) ul.Borowa 14/18 05-400 Otwock, Poland www.ecz-otwock.pl The course will be held on Philips equipment: Learning Objectives ...................................................................................................................................... 2 Preliminary Programme ............................................................................................................................... 4 Preliminary Faculty ........................................................................................................................................ 5 Registration....................................................................................................................................................... 5 Contact ESMRMB Office, Neutorgasse 9, 1010 Vienna Tel.: 0043 - (0)1 - 535 13 06 [email protected] www.esmrmb.org www.esmrmb.org [email protected] 1 Learning Objectives Lectures (50% of the course) Basics of Advanced Neuroimaging The theoretical background of fMRI, DTI and perfusion MRI will be approached from a practical perspective. Clinical applications will be addressed. Technical set-up fMRI fMRI requires an environment in which subjects perform specific tasks (finger movement, listening to text or music, viewing images, et cetera). Response monitoring, such as by pressing buttons, may be required for certain procedures. We will discuss these requirements and the equipment that is available to fulfil them. fMRI task design Design of the fMRI experiment is crucial. The most commonly used fMRI clinical paradigms will be discussed. We will focus on clinical tasks for the localisation of the primary motor cortex and the assessment of hemispheric dominance of language processing as examples of the design process. Principles of data analysis The interpretation of fMRI, DTI and perfusion MRI requires extensive post processing. A short overview of the post-processing steps will be given. Software packages for data-analysis will be explained and discussed: specifically those provided by Philips Healthcare (Console, IntelliSpace Portal WorkStation) and Invivo Neuro workspots. Clinical and research applications Clinical applications of fMRI, DTI and perfusion MRI will be discussed and an overview of the relevant functional anatomy of the brain will be given. We will also provide a short introduction into several research applications of advanced neuroimaging. www.esmrmb.org [email protected] 2 Hands-On MRI (50% of the course) Scanner console interface All scanning will be performed on a Philips Healthcare system. We will provide ample opportunity to become familiar with the scanner console interface. Data acquisition Monitoring of data acquisition is particularly important and will be specifically addressed. Sequence adjustments to optimize image quality and contrast, as discussed in the lectures, will be practiced and visualised. Instruction and preparation of subjects We will emphasize optimal subject instruction prior to the study and monitoring of subject performance during scanning. Data analysis We will practice data analysis extensively. Hands-on practical workshops will use Philips Healthcare software for data analysis (IntelliSpace Portal) and Invivo. www.esmrmb.org [email protected] 3 Preliminary Programme Thursday, September 18, 2014 12:30 Registration 13:30 Welcome 13:40 Basics of fMRI (technique, optimisation, data-acquisition, quality control) 14:30 fMRI task design and setup 15:15 Coffee break 15:45 Basics of DTI (technique, optimisation, data-acquisition, quality control) 16:30 fMRI data analysis and post-processing 17:15 Welcome reception Friday, September 19, 2014 08:30 DTI data analysis and post-processing 09:00 Data handling and data transfer 09:30 Hands-On Live scanning sessions: fMRI Workstations: DTI analysis 11:00 Coffee break 11:15 Hands-On Live scanning sessions: fMRI Workstations: DTI analysis 12:45 Lunch 13:45 Basics of perfusion imaging and analysis (DSE/DCE) 14:30 Basics of perfusion imaging and analysis (ASL) 15:00 Functional neuroanatomy 15:30 Coffee break 16:00 Hands-On Live scanning session: DTI/ASL/DSE Workstations: fMRI analysis Saturday, September 20, 2014 09:00 Hands-On Live scanning session: DTI/ASL/DSE Workstations: fMRI analysis 10:30 Coffee break 11:00 Hands-On www.esmrmb.org [email protected] 4 12:30 13:30 15:00 15:30 16:15 17:00 Live scanning session: DTI/ASL/DSE Workstations: ASL/DSE/DCE Lunch Hands-On Live scanning sessions: DTI/ASL/DSE Workstations: ASL/DSE/DCE Coffee break Clinical applications of fMRI, DTI and perfusion imaging Advanced fMRI and DTI for research applications Closing remarks and end of the course Preliminary Faculty A. Bjornerud, L. Kownacki, A. Nederveen, M. Nillson, R. Peeters Registration Registration will be available at www.esmrmb.org soon! Early registration fees (until 8 weeks prior to the course beginning) ESMRMB Member* € 550 Non-Member € 650 Late registration fees (after 8 weeks prior to the course beginning) ESMRMB Member* € 650 Non-Member* € 750 * To attend the Hands-On MRI 2014 course as a member, ESMRMB membership fee for the year 2014 must be settled. www.esmrmb.org [email protected] 5
© Copyright 2024 ExpyDoc