THE MILLSTREAM MODEL N° © COPYRIGHT 4935 NOTE: • TOP OF FOOTINGS FOR PIER/POSTS TO CARPORT & VERANDAH ARE TO BE 2c BELOW FINISHED PAVING LEVEL Ground floor 15,790 75 • 290w x 119 x 90 FACEBRICK 590 2,110 2,540 CL 190 x 45 190 x 45 190 x 45 190 x 45 DP 190 x 45 198 x 60 GLULAM DP FLOOR PLAN 230 390 CHK DP living dining 3,950 7,690 90 90 wir 1,310 THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. ensuite 90 m/suite 1,790 1,500 UNLINED VERANDAH DATE VO # 1,610 CL 75 198 x 60 GLULAM 18x2110 verandah B/PAVED @ -1c 18x2110 UNLINED B/PAVED @ -1c 1,655 18x1010 OBS CARPORT 75 CL 18x2110 820 TF A Division of JWH GROUP Sub-contractors to verify all dimensions on site. 230 450 ENS. A.B.N. 84 098 664 709. DATED:......./......./....... 1,500 FW 5,000 ENT. 198 x 60 GLULAM carport SITTING FW MASTER SUITE 290 BATH CL V 2,690 REPRESENTATION OF "COMMODORE" SIZED SEDAN 1,595 450 WIDE SH & RAIL REV 1,610 25x1610 WIR 700 FHO W/CORNICE OVER 190 x 45 1,600 S 190 x 45 CL 450 WIDE SH & RAIL BR. 4 x 450 WIDE SH @ 400 CTS BED 2 4,190 DP PLAST WALL UNDER 930 FHO W/CORNICE OVER E-VENT 450 WIDE SH & RAIL 190 x 45 1,425 LIVING Reg. Builder Nº: 11421. DRN 720 720 190 x 45 HARDIFLEX SPANDREL 3 14x710 OBS ROBE KITCHEN 620 s/c 25x1510 SD 820 LINEN LAM PTY S MH 720 690 GAS/ELECTRIC METERBOX BLOCKS TO EXTERNAL LEAF. BLOCKS ARE TO BE LAID IN THIRD STRETCHER BOND. • R2.5 INSULATION TO FLAT CEILING AREAS OF HOUSE ONLY. 25x2110 FR 820 L'DRY WM DINING SOLAR HWS 820 FW T CL 25x1610 690 BED 4 450 WIDE SH & RAIL WC FV 25x2410 SD 2,615 230 790 3,950 dining/living DP GAS HP BED 3 CL 75 X 2,410 14x1910 930 FHO W/CORNICE OVER FW PV OBS 14x510 18x2110 620 230 1,500 590 1,910 3,190 1,090 230 kitchen 2,110 • PROVIDE HOOP IRON HOLDING DOWN STRAPS TO AS 4055. 6,250 4 295 1,890 510 2,890 bed 4 690 18x2110 WIR 1,550 90 sitting 3,190 2,550 390 bed 3 DP 850 3,950 90 930 pass 2,600 230 710 2,110 90 TAP br bath 90 600 230 2,590 930 90 90 640 linen bed 2 2,550 1,390 5,230 90 TAP DP verandah 230 kitchen bed 4 2,930 bed 3 2,930 wir 930 robe bed 2 1,530 2,770 230 230 230 230 1,390 90 wc 1,450 90 1,570 laundry 7,690 90 90 230 800 wir WALL MOUNTED GAS BOOSTER FOR SOLAR HWS 1,500 90 190 x 45 Ground Floor 25.6º PITCHED ROOF = 153.21m² 9º PITCHED ROOF = 33.92m² 187.13m² TOTAL AREA 90 190 x 45 230 ROOF AREA(s) ON FLAT: 9,190 • LOCATION OF DOWN PIPES IS INDICATIVE ONLY & MAY BE CHANGED AT BUILDERS DISCRETION 21,020 820 46.960 54.840 101.800 1,340 Perimeter (m) 820 Location 1,260 Area (m2) HOUSE 121.430 VERANDAH 49.680 171.110 OWNER WITNESS OWNER WITNESS BUILDER WITNESS CLIENT: D1 1:100 1 100 75 CL CL CL 2,897 2,897 CL 2,897 X 490 2,110 230 1,630 230 S DENOTES SMOKE DETECTOR 1,590 90 laundry 90 830 linen 3,570 bed 2 1,010 990 90 90 90 930 830 90 2,110 CL 2,080 1,190 880 720 CL CL 2,385 2,385 2,110 2,590 CL 75 5,230 ADDRESS: 5,230 carport 830 broom 90 1,750 bath 90 3,670 sitting 15,790 90 950 entry 90 3,200 m/suite 230 1,740 ensuite/wir 5,230 SHEET N° 1 OF 6 + 2 ANC JOB N° REVISION DATE - STD Drawn By: DJB 17/7/2006 2 THE MILLSTREAM E-VENT MODEL N° COLORBOND ROOF @ 25° 38' PITCH VERANDAH ROOF @ 9° PITCH © COPYRIGHT 4935 CL 28c + PLATE 2440 23c TOF @ 25c FL 120 0c 7c 7c 4c 4c ELEVATION 1 OBSC. GLAZING 7c 3c RENDERED SILLS TO FRONT ELEVATION 1:100 4c 0c TF 150Ø TIMBER POLES W/450 x 450 x 300D MASS CONC FOOTINGS Reg. Builder Nº: 11421. A.B.N. 84 098 664 709. BARGE & ROLLED EDGE CAPPING DRN HARDIFLEX SPANDREL REV A Division of JWH GROUP DATE CHK VO # CL 28c + PLATE 2440 25c 25c 23c 11c PV FL OBSC. GLAZING 0c 6c 0c GAS/ELECTRIC METERBOX ELEVATION 2 Sub-contractors to verify all dimensions on site. 1:100 E-VENT THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. SOLAR HWU CL 28c + PLATE 2242 25c 25c 2440 25c 25c DATED:......./......./....... OWNER WITNESS OWNER WITNESS 25c 11c 7c 7c 7c BUILDER FL 0c 0c WITNESS 0c CLIENT: ELEVATION 3 1:100 CL 28c + PLATE 2440 23c 25c 2250 25c 11c 7c FL 0c 0c SHEET N° 2 OF 6 + 2 ANC JOB N° ELEVATION 4 1:100 REVISION DATE - STD Drawn By: DJB 17/7/2006 ADDRESS: EXTEND POLE THRU' TO RIDGE BARGE & ROLLED EDGE CAPPING B/WORK BEYOND NO HARDIFLEX SPANDREL TO THIS SIDE OF VERANDAH THE MILLSTREAM MODEL N° © COPYRIGHT 4935 COLORBOND ROOF @ 25.60° PITCH 120 x 35 TIMBER BIRDBOARD VERANDAH ROOF @ 9° PITCH 28c 120 x 35 TIMBER BIRDBOARD 190 x 45 TIMBER BEAM 23c 150Ø TIMB POLE Reg. Builder Nº: 11421. A.B.N. 84 098 664 709. DRN REV 1,500 A Division of JWH GROUP DATE CHK VO # DETAL 1 - VERANDAH 1:20 Sub-contractors to verify all dimensions on site. THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. DATED:......./......./....... STANDARD ROOF CONSTRUCTION AS PER SPECIFICATIONS. COLORBOND ROOF @ 25° 38' PITCH OWNER WITNESS OWNER WITNESS BUILDER WITNESS CLIENT: CL 28c + PLATE 23c 480W BOXED & LINED EAVES FL DINING 0c SHEET N° SECTION X-X 3 OF 6 + 2 ANC REINFORCED CONCRETE SLAB AND FOOTING TO ENG. DETAILS JOB N° 1:50 REVISION DATE - STD Drawn By: DJB 17/7/2006 2440 ADDRESS: ENTRY THE MILLSTREAM MODEL N° R/HOOD FLUMED TO CEILING 32 4 SHELVES @ 400 CTS 4935 BANK OF 4 DRAWERS 32 LAM PTY 650 FR R/HOOD © COPYRIGHT K1 811 K2 600w x 1850h PIVOT DOOR (CLEAR LAM) 911h PLAST WALL UNDER 100 943 SHELF SHELF 100 UBO 943 811 150 SHELF K3 425w x 1850h SHR SCREEN 620w x 1850h SHR SCREEN Reg. Builder Nº: 11421. A.B.N. 84 098 664 709. DRN REV A Division of JWH GROUP DATE CHK VO # 150 BATH 800 429 SHELF 618 32 1 ROW OF TILES SHELF BATH HOB 150 2,000 1000h x 900 w MIRROR B2 B1 Sub-contractors to verify all dimensions on site. THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. 2,790 DATED:......./......./....... 2,190 920 1,695 500 CL SINK 1 K 3 OWNER WITNESS 900 CLIENT: VOID 915 FW 100 1 WITNESS ADDRESS: BATH 775 1,410 1,170 2 FR 2 O/HANG 150 90 911h PLAST WALL UNDER 4 SHELVES @ 400 CTS B • POSTFORMING TO STRAIGHT EDGES OF BENCHTOPS AS INDICATED WITH A DASHED LINE. 815 CABINETMAKER NOTE: BANK OF 4 DRAWERS LAM PTY SHR V 740 RANGEHOOD UBO OVER 715 600 SINGLE BOWL INSET SINK W/- MIXER TAP WITNESS BUILDER 600 GAS HP 255 2,170 600 600 720 OWNER 90 150 600 O/HANG 1,950 KITCHEN 1:50 1,750 840 BATHROOM 1:50 SHEET N° 4 OF 6 + 2 ANC JOB N° REVISION DATE - STD Drawn By: DJB 17/7/2006 600 THE MILLSTREAM 600w x 1850h SHR SCREEN MODEL N° © COPYRIGHT 4935 C'ROD 32 2,000 840w x 1850h MIRROR 150 SHELF 150 E1 E2 Reg. Builder Nº: 11421. A.B.N. 84 098 664 709. DRN REV DATE CHK 1,180 CL 415 2 ROWS OF TILES CL CL WM TAPS 1,100 1,200 CL A Division of JWH GROUP VO # Sub-contractors to verify all dimensions on site. THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. LAUNDRY ELEVATION DATED:......./......./....... 1:50 OWNER WITNESS OWNER WITNESS BUILDER 840 WITNESS 900 100 CLIENT: 740 VOID ADDRESS: 900 500 SHR s/c 620 E 2 ENSUITE 425 CL 1 • POSTFORMING TO STRAIGHT EDGES OF BENCHTOPS AS INDICATED WITH A DASHED LINE. SHEET N° 1:50 5 OF 6 + 2 ANC JOB N° REVISION DATE - STD Drawn By: DJB 17/7/2006 CABINETMAKER NOTE: FW 465 800 618 SHELF THE MILLSTREAM MODEL N° © COPYRIGHT ELECTRICAL LEGEND S V 2-WAY © DP 18x2110 18x2110 14x1910 DP 25x2410 SD Reg. Builder Nº: 11421. REV 820 DP FR 1650 820 FW T WM MH 720 820 S OWNER WITNESS OWNER WITNESS 720 BUILDER 720 S WITNESS 820 1200 FV CLIENT: 820 V 1200 AFL FW FW 620 s/c GAS/ELECTRIC METERBOX 820 TF DP 18x2110 18x1010 OBS DP 18x2110 ADDRESS: 18x2110 DP DP ELECTRICAL 1:100 SHEET N° 6 OF 6 + 2 ANC JOB N° REVISION DATE - STD Drawn By: DJB 17/7/2006 25x1510 SD 620 LAM PTY CHK DATED:......./......./....... 25x1610 FW PV OBS 14x510 SOLAR HWS DATE VO # THIS IS ONE OF THE DRAWINGS REFERRED TO IN THE CONTRACT. 25x1610 ISOLATING SWITCH FOR UBO GPO @ 1800 FOR R/HOOD A Division of JWH GROUP Sub-contractors to verify all dimensions on site. 25x2110 GPO @ 700 FOR GAS HP WALL MOUNTED GPO @ 1650 FOR BOOSTER A.B.N. 84 098 664 709. DRN 14x710 OBS WALL MOUNTED GAS BOOSTER FOR SOLAR HWS CEILING LIGHT WALL LIGHT @ 1800 OR AS NOMINATED DOWN LIGHT DOWN LIGHT - LOW VOLTAGE FLUORESCENT LIGHT - SINGLE FLUORESCENT LIGHT - SINGLE WITH DIFFUSER SENSOR EXHAUST FAN CEILING MOUNTED EXHAUST FAN / LIGHT COMBINATION EXHAUST FAN / LIGHT / HEATER COMBINATION SMOKE DETECTOR GPO @ 200 A.F.L. - SINGLE GPO @ 200 A.F.L. - DOUBLE GPO @ 200 A.F.L. - MULTIPLE GPO @ 875 A.F.L. OR AS NOMINATED - SINGLE GPO @ 875 A.F.L. OR AS NOMINATED - DOUBLE GPO @ 875 A.F.L. OR AS NOMINATED - MULTIPLE GPO @ 1018 A.F.L. - SINGLE GPO @ 1018 A.F.L. - DOUBLE GPO @ 1018 A.F.L. - MULTIPLE GPO W'PROOF @ 1200 A.F.L. OR AS NOMINATED - SINGLE GPO W'PROOF @ 1200 A.F.L. OR AS NOMINATED - DOUBLE GPO W'PROOF @ 1200 A.F.L. OR AS NOMINATED - MULTIPLE GAS NEGUS POINT & CEILING VENT TELEPHONE POINT T.V. POINT DATA POINT TWO WAY SWITCHING CONDUIT 4935
© Copyright 2024 ExpyDoc