IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882
August 1, 2014
Martin Oud
Coining, Inc.
15 Mercedes Drive
Montvale, NJ 07645
cc: Lisa Maffei
TEST REPORT
IMR Report Number 201409707E (Lot # 148918)
PO Number
PO103187
Date Received
July 30, 2014
Material
Cu80Ag15P5
Lot #
148918
Item No
M27189
SUMMARY
One sample was received for chemical analysis.
Based on the results, the sample complies with the MCVs for cadmium,
lead, hexavalent chromium, and mercury as specified by the EU
Commission in the amendment to the RoHS Directive. Note that bromine
was not tested due to the fact that brominated flame retardants are not
intentionally used in the manufacturing of glass/metallic materials.
The results are on the following page(s).
Specification(s)
EU Directive 2011/65/EU
(RoHS), maximum
concentration values (MCVs)
per Annex II
Reviewed by
Reviewed by
Brian Wackowicz for
Cheryl Downey
Report Review Specialist
Andrew Ensign, Supervisor
Chemistry Department
All procedures were performed in accordance with the IMR Quality Manual, current revision, and related procedures; and the PWA-MCL Manual F-23 and related procedures. The
information contained in this test report represents only the material tested and may not be reproduced, except in full, without the written approval of IMR, Inc. IMR, Inc. maintains a
quality system in compliance with the ISO/IEC 17025 and is accredited by the American Association for Laboratory Accreditation (A2LA), certificates #1140.01 and #1140.02. IMR Test Labs
will perform all testing in good faith using the proper procedures, trained personnel, and equipment to accomplish the testing required. IMR’s liability to the customer or any third party is
limited at all times to the amount charged for the services provided. All samples will be retained for a minimum of 6 months and may be destroyed thereafter unless otherwise specified by
the customer. The recording of false, fictitious, or fraudulent statements or entries on this document may be punished as a felony under federal statutes. IMR Test Labs is a GEAE S-400
approved lab (Supplier Code T3983).
Coining, Inc.
Page 1 of 3
IMR # 201409707E
IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882
CHEMISTRY
Element
Lot # 148918
RoHS MCVs
Cd
<10 ppm
100 ppm
Cr*
<100 ppm
1000 ppm
Hg1
<1 ppm
1000 ppm
Pb
<30 ppm
1000 ppm
Sn
<0.005
---
Sb
<0.005
Cu
Remainder
-----
Au
<0.005
---
Ag
15.76
---
Al
0.001
---
Bi
<0.005
---
In
<0.005
---
Fe
<0.0005
---
Ni
<0.003
---
Zn
<0.001
---
B
<0.005
---
Ga
<0.005
---
Ge
<0.005
---
Mg
<0.005
---
Mn
<0.0005
---
P
4.90
---
Pd
<0.005
---
Pt
<0.005
---
Si
<0.001
---
Ti
<0.001
---
Be
<0.0005
---
Purity
>99.990
---
1Determined
by DMA (Direct Mercury Analyzer).
Other elements tested (<0.01%): Ba, Be, Bi, Ca, Co, Cu, Fe, In, Li, Mg, Mn, Na, Ni, P, Sb, Se, Sn, Sr, Ti, V,
Zn, & Zr.
Results in weight percent unless otherwise indicated.
ppm = parts per million.
Method(s): CAP-017N (ICP-AES), CAP-054E Direct Mercury Analyzer (DMA) and IEC62321 Rev. 1.0
(Modified).
Coining, Inc.
Page 2 of 3
IMR # 201409707E
IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882
*The results represent total chromium; note that hexavalent chromium cannot exceed the total
chromium concentration.
Sample received at IMR
Cutting / Preparation
/ Measurement
Cd, Pb, Cr, and all
other elements
Hg
Fine Shavings run
directly by DMA
Mixed Acid digestion
Solution
ICP-AES
Figure 1:
Coining, Inc.
Flow chart for analysis.
Page 3 of 3
IMR # 201409707E