IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882 August 1, 2014 Martin Oud Coining, Inc. 15 Mercedes Drive Montvale, NJ 07645 cc: Lisa Maffei TEST REPORT IMR Report Number 201409707E (Lot # 148918) PO Number PO103187 Date Received July 30, 2014 Material Cu80Ag15P5 Lot # 148918 Item No M27189 SUMMARY One sample was received for chemical analysis. Based on the results, the sample complies with the MCVs for cadmium, lead, hexavalent chromium, and mercury as specified by the EU Commission in the amendment to the RoHS Directive. Note that bromine was not tested due to the fact that brominated flame retardants are not intentionally used in the manufacturing of glass/metallic materials. The results are on the following page(s). Specification(s) EU Directive 2011/65/EU (RoHS), maximum concentration values (MCVs) per Annex II Reviewed by Reviewed by Brian Wackowicz for Cheryl Downey Report Review Specialist Andrew Ensign, Supervisor Chemistry Department All procedures were performed in accordance with the IMR Quality Manual, current revision, and related procedures; and the PWA-MCL Manual F-23 and related procedures. The information contained in this test report represents only the material tested and may not be reproduced, except in full, without the written approval of IMR, Inc. IMR, Inc. maintains a quality system in compliance with the ISO/IEC 17025 and is accredited by the American Association for Laboratory Accreditation (A2LA), certificates #1140.01 and #1140.02. IMR Test Labs will perform all testing in good faith using the proper procedures, trained personnel, and equipment to accomplish the testing required. IMR’s liability to the customer or any third party is limited at all times to the amount charged for the services provided. All samples will be retained for a minimum of 6 months and may be destroyed thereafter unless otherwise specified by the customer. The recording of false, fictitious, or fraudulent statements or entries on this document may be punished as a felony under federal statutes. IMR Test Labs is a GEAE S-400 approved lab (Supplier Code T3983). Coining, Inc. Page 1 of 3 IMR # 201409707E IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882 CHEMISTRY Element Lot # 148918 RoHS MCVs Cd <10 ppm 100 ppm Cr* <100 ppm 1000 ppm Hg1 <1 ppm 1000 ppm Pb <30 ppm 1000 ppm Sn <0.005 --- Sb <0.005 Cu Remainder ----- Au <0.005 --- Ag 15.76 --- Al 0.001 --- Bi <0.005 --- In <0.005 --- Fe <0.0005 --- Ni <0.003 --- Zn <0.001 --- B <0.005 --- Ga <0.005 --- Ge <0.005 --- Mg <0.005 --- Mn <0.0005 --- P 4.90 --- Pd <0.005 --- Pt <0.005 --- Si <0.001 --- Ti <0.001 --- Be <0.0005 --- Purity >99.990 --- 1Determined by DMA (Direct Mercury Analyzer). Other elements tested (<0.01%): Ba, Be, Bi, Ca, Co, Cu, Fe, In, Li, Mg, Mn, Na, Ni, P, Sb, Se, Sn, Sr, Ti, V, Zn, & Zr. Results in weight percent unless otherwise indicated. ppm = parts per million. Method(s): CAP-017N (ICP-AES), CAP-054E Direct Mercury Analyzer (DMA) and IEC62321 Rev. 1.0 (Modified). Coining, Inc. Page 2 of 3 IMR # 201409707E IMR Test Labs • 131 Woodsedge Drive • Lansing, NY 14882 *The results represent total chromium; note that hexavalent chromium cannot exceed the total chromium concentration. Sample received at IMR Cutting / Preparation / Measurement Cd, Pb, Cr, and all other elements Hg Fine Shavings run directly by DMA Mixed Acid digestion Solution ICP-AES Figure 1: Coining, Inc. Flow chart for analysis. Page 3 of 3 IMR # 201409707E
© Copyright 2024 ExpyDoc