1 2 TYPE EXAMINATION CERTIFICATE Equipment or Protective systems intended for use in Potentially Explosive Atmospheres - Directive 94/9/EC 3 Type Examination Certificate No: FM13ATEX0020 4 Equipment or protective system: (Type Reference and Name) Maxon DuraStep Valve Actuator Models xxxxxDSxx-xxxx-abcde-xxx, DSCA-xxx-abcde-000 & DSSA-abcde-000 5 Name of Applicant: Maxon-A Honeywell Company 6 Address of Applicant: 201 E. 18th Street Muncie, IN 47302 U.S.A. 7 This equipment or protective system and any acceptable variation thereto is specified in the schedule to this certificate and documents therein referred to. 8 FM Approvals Ltd. certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. The examination and test results are recorded in confidential report number: 0003046182 dated 8th May 2014 9 Compliance with the Essential Health and Safety Requirements, with the exception of those identified in item 15 of the schedule to this certificate, has been assessed by compliance with the following documents: EN60079-0:2012 + A 11: 2013, EN60079-15:2010, EN60079-31:2009, EN60529:2000 10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate. 11 This Type Examination certificate relates only to the design, examination and tests of the specified equipment or protective system in accordance to the directive 94/9/EC. Further requirements of the Directive apply to the manufacturing process and supply of this equipment or protective system. These are not covered by this certificate. 12 The marking of the equipment or protective system shall include: II 3 G Ex nA nC IIC Gc T4 -40°C < Ta < 70°C II 3 D Ex tc IIIC T135°C Dc IP67 Mick Gower cn=Mick Gower, o=FM Approvals, ou, [email protected], c=GB 2014.05.13 14:16:00 +01'00' Mick Gower Certification Manager, FM Approvals Ltd. Issue date: 13th May 2014 THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com F ATEX 029 (Oct/12) Page 1 of 3 SCHEDULE to Type Examination Certificate No. FM13ATEX0020 13 Description of Equipment or Protective System: The DuraStep Valve Actuators are industrial rotary (1/4-turn) actuators that can be direct coupled to Maxon control valves or burner assemblies. In addition, it will be offered with standalone valve adapter hardware for direct coupling or with linkage to 3rd-party valves and dampers. All models would utilize the basic drive train, feedback, and control concepts developed for the existing Maxon SmartFire, SMARTLINK CV and MRV actuator. The actuators can be provided with or without a display and keypad. The xx...x within the model number refers to variables (i.e. valve size, valve type, flow capacity, valve body material, valve body connection, etc.) not affecting certification. The DuraStep Valve Actuator will be labeled as a SMARTLINK DS (DS standing for DuraStep) followed by the model number. The actuator complies with the environmental requirements of IP67. Operation Temperature Ranges: The ambient operating temperature range of the DuraStep Actuator is -40°C to 70°C. Electrical data: Vin = 24 Vdc +5% (optional 100-240 VAC +10%, 50/60 Hz power supply); Iin = 1.1 A max (0.3 A @100 VAC) Pin = 17 W (19 W with AC power supply) 4…20 mA interface. 14 Special Conditions for Safe Use: None 15 Essential Health and Safety Requirements: The relevant EHSRs that have not been addressed by the standards listed in this certificate have been identified and assessed in the confidential report identified in item 8. 16 Test and Assessment Procedure and Conditions: This Type Examination Certificate is the result of testing of a sample of the product submitted, in accordance with the provisions of the relevant specific standard(s), and assessment of supporting documentation. It does not imply an assessment of the whole production. Whilst this certificate may be used in support of a manufacturer’s claim for CE Marking, FM Approvals Ltd accepts no responsibility for the compliance of the equipment against all applicable Directives in all applications. This Certificate has been issued in accordance with FM Approvals Ltd’s ATEX Certification Scheme. THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com F ATEX 029 (Oct/12) Page 2 of 3 SCHEDULE to Type Examination Certificate No. FM13ATEX0020 17 Schedule Drawings A list of the significant parts of the technical documentation is annexed to this certificate and a copy has been kept by FM Approvals Ltd. 18 Certificate History Details of the supplements to this certificate are described below: Date Description 13th May 2014 Original Issue. THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com F ATEX 029 (Oct/12) Page 3 of 3 Blueprint Report Maxon-A Honeywell Company (1000000013) Class No 3611 Original Project I.D. Certificate I.D. 3041711 FM13ATEX0020 Drawing No. Revision Level Drawing Title Last Report Electronic Drawing 1121736 B01 900 IN-LBS PLNTRY GEAR HEAD 3041711 Yes (pdf) 1121737 B01 300 IN-LBS PLNTRY GEAR HEAD 3041711 Yes (pdf) 1121738 A02 DBL END SHFT STPPR MTR 3041711 Yes (pdf) 1121739 5/15/2012 MAGNTC BRK 3041711 Yes (pdf) 1121740 8/23/2012 DUAL PTNMTR PWB 3041711 Yes (pdf) 1121741 5/15/2012 DUAL PTNMTR WIPER ASY 3041711 Yes (pdf) 1121742 5/15/2012 AC/DC PWR SPPLY 3041711 Yes (pdf) 1121743 8/27/2012 MMBRN SW 3041711 Yes (pdf) 1121744 5/16/2012 2X16 LCD DSPLY 3041711 Yes (pdf) 1121748 5/23/2012 PCB ASY 3041711 Yes (pdf) 1121749 B01 SHRT HSG W/DSPLY 3041711 Yes (pdf) 1121750 B02 SHRT PWR SPPLY HSG W/DSPLY 3041711 Yes (pdf) 1121751 A01 END CVR 3041711 Yes (pdf) 1121752 A01 PWR SPPLY CVR 3041711 Yes (pdf) 1124866 5/15/2012 SELD AC/DC PWR SPPLY 3041711 Yes (pdf) Yes (pdf) 50065700 1 Schematic 3041711 50111245-001 A02 SHRT PWR SPPLY HSG 3041711 Yes (pdf) 50111246-001 A01 SHRT HSG 3041711 Yes (pdf) 50111247-001 A02 TALL PWR SPPLY HSG W/DSPLY 3041711 Yes (pdf) 50111248-001 A01 TALL HSG W/DSPLY 3041711 Yes (pdf) 50111249-001 A02 TALL PWR SPPLY HSG 3041711 Yes (pdf) 50111250-001 A01 TALL HSG 3041711 Yes (pdf) 50111602-001 5/15/2012 157 SILCN ORING (HSG ORING) 3041711 Yes (pdf) 50111603-001 5/15/2012 257 SILCN ORING (POW SPPLY ORING) 3041711 Yes (pdf) 50111830-001 8/22/2012 Ø.669 SHFT SEAL 3041711 Yes (pdf) 50112151-001 - ACTUATOR ASYREF 3041711 Yes (pdf) 50113276-001 A02 SMARTLINK DS VLV ACT LBL 3041711 Yes (pdf) 50116907-001 - SMARTLINK DS ACT SCHMTC LBL 3041711 Yes (pdf) 50119799-001 00 ACT INDSTRL BEZEL 3041711 Yes (pdf) 13/05/2014 Page 1 of 1
© Copyright 2024 ExpyDoc