ECO PLACIDUS ELONGATED FLUSHOMETER 4.8L TOILET VITREOUS CHINA ECO PLACIDUS ELONGATED FLUSHOMETER 4.8L TOILET • Wall-mounted flushometer valve toilet • Vitreous china • Meets definition for HET (High Efficiency Toilet) • High Efficiency (4.8 Lpf/1.07 gpf) • Will also function at 4.2 Lpf/0.9 gpf and 6 Lpf/1.3 gpf with a properly set dual flush valve • Condensation channel • Elongated bowl • Powerful direct-fed siphon jet action • 38mm (1-1/2") inlet spud • Fully glazed 54mm (2-1/8") trapway • 254 x 305mm (10" x 12") water surface area • 100% factory flush tested (Flushometer valve & seat shown not included) ❏ ❏ ❏ 3446NS Elongated bowl only, top spud 3H722NS Elongated bowl only, top spud with slotted rim for bedpan holding 3449NS Elongated bowl only, back spud Component Parts: ❏ 047007-0070A Inlet spud (furnished with bowl) Nominal Dimensions: 660 x 356 x 381mm (26" x 14" x 15") Fixture only, less seat, bolt caps and flushometer valve Recommended working pressurebetween 25 psi at valve when flushing and 80 psi static. Compliance Certifications Meets or Exceeds the Following Specifications: • ASME A112.19.2-2008 / CSA B45.1-08 for Vitreous China Fixtures NOTE: Roughing-in information shown on reverse side of page To Be Specified: ❏ Colour: ❏ White ❏ Seat: ❏ American Standard #5901 100 Heavy duty open front less cover ❏ American Standard #5905 100 Extra heavy duty open front less cover ❏ Alternative Seat: ❏ Flushometer Valve: ❏ American Standard Selectronic™ #6065 121.002 DC Power (Top Spud) ❏ American Standard Selectronic™ #6065 222.007 DC Power (Concealed Back Spud) ❏ American Standard Selectronic™ #6067 222.007 AC Power (Concealed Back Spud) ❏ American Standard Selectronic™ #6068 222.007 Multi AC Power (Concealed Back Spud) ❏ Alternative Flushometer Valve: MEETS THE AMERICAN DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USEABLE BUILDING FACILITIES-CHECK LOCAL CODES ● When installed so top of seat is 432 to 483mm (17" to 19") from the finished floor. Certified by IAPMO R&T 07/11 © 2011 AS Canada ULC ECO PLACIDUS ELONGATED FLUSHOMETER 4.8L TOILET VITREOUS CHINA 3446NS 3H722NS 1" N.P.T. OR C.W.T. SUPPLY AS REQUIRED TO FLUSH VALVE FINISHED WALL 660mm (26) 121mm (4-3/4) 73mm (2-7/8) 470mm (18-1/2) C/L OF SEAT POST HOLES 140 mm (5-1/2) CENTRE 19mm (3/4) 95mm (3-3/4) 342mm (13-1/2) 133mm (5-1/4) 356mm (14) (4) 22mm (7/8) HOLES 229mm (9) 381mm (15) FINISHED FLOOR 70mm (2-3/4) 3449NS 1-1/2 SPUD C/L C/L OF OUTLET 292mm (11-1/2) 191mm (7-1/2) 133mm (5-1/4) 32mm (1-1/4) FINISHED WALL 660mm (26) 76mm(3) DIA. HOLE IN WALL FOR 1-1/2 SPUD C/L 470mm (18-1/2) 356mm (14) C/L OF SEAT POST HOLES 140mm(5-1/2) CENTRES 70mm (2-3/4) 133mm (5-1/4) (3/4) 19mm 95mm (3-3/4) 330mm (13) FINISHED FLOOR 89mm (3-1/2) (4) 22mm (7/8) DIA. HOLES 229mm (9) 381mm (15) C/L OF OUTLET 191mm (7-1/2) 283mm (11-1/8) 330mm (13) 133mm (5-1/4) 32mm (1-1/4) NOTES: ● Toilet designed to meet ADA accessibility standards with seat\ height set at 432 to 483mm (17" to 19") from finished floor. WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING NOT RECOMMENDED). SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. CARRIER FAUCET AS REQUIRED TO BE FURNISHED BY OTHERS. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerance established by ANSI Standard A112.19.2 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. © 2011 American Standard 07/11
© Copyright 2024 ExpyDoc