AFWALL® MILLENIUM™ FloWise® 1.1 GPF FLUSHOMETER

AFWALL® MILLENIUM™ FloWise®
1.1 GPF FLUSHOMETER TOILET SYSTEM
SELECTRONIC® EXPOSED AC FLUSH VALVE
BARRIER FREE
AFWALL® MILLENIUM™ FloWise® 1.1 GPF
FLUSHOMETER TOILET SYSTEM
❏2257.711 1.1 gpf Exposed Top Spud Bowl
and Selectronic® Exposed AC Flush Valve
BOWL:
• Wall-hung elongated flushometer valve toilet
• Vitreous china
• High Efficiency. Operates in the range of 1.1 gpf to
1.6 gpf (4.2 Lpf to 6.0 Lpf)
• Powerful direct-fed siphon jet action
• Fully-glazed 2-1/8" trapway
• Condensation channel
• 1-1/2" inlet spud
• 10" x 12" water surface area
• 100% factory flush tested
• Bolt caps and seat not included
• Model 2257.101
SELECTRONIC® FLUSH VALVE:
• Self-Cleaning Piston with integral wiper spring
significantly reduces clogging and maintenance
• Selectronic® Proximity System with universal sensor
provides hygienic, "hands free" operation
• State-of-the-Art Electronics prevent ghost flushing
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
• Dezincification Resistant semi-red brass alloy
• Fully Mechanical Manual Override Button can flush
the valve without power
• Fail-Safe: Valve automatically closes upon loss of power High-Efficiency Toilet System
or water pressure and does not need to be reset
• 31.3% water savings when compared to
• Adjustable Sanitary Flush cleans the fixture & maintains 1.6 gpf toilet systems
the trap seal.
System MaP Score:
• Chemical Resistant EPDM Seals for extended life
• 1,000 grams of miso @ 1.1 gpf
• Adjustable Tailpiece for rough-in flexibility
* Maximum Performance (MaP) testing performed by
• Can be installed left or right handed
IAPMO R&T Lab. MaP Report conducted by Veritec
• Includes Class 2 UL certified universal hard-wired
Consulting, Inc. and Koeller and Company
AC transformer
• Optional cover plate only required for installation
Operating Pressure:
from the front
Overall Range: 20-125 psi**
• Model 6067.111
Recommended: 25 psi (flowing) - 80 psi (static)
Includes:
• 047007-0070A Inlet Spud (furnished with bowl)
• 481310-100 2 Bolt caps with retainers (furnished
with bowl)
• 1" I.P.S. angle stop with back-flow protection
and vandal resistant cap
• 1" Sweat solder kit including cover tube and wall flange
• 1-1/2" High back pressure vacuum breaker,
spud coupling and flangee
** Water pressure over 80 psi is not
recommended for most plumbing fixtures
Flow Requirement:
25gpm (94.6 L/min.)
Nominal Fixture Dimensions:
660 x 356 x 381mm (26" x 14" x 15")
To Be Specified:
❏ Color: ❏ White
❏ Seat:
❏ American Standard #5901.100
Heavy duty open front less cover
❏ American Standard #5905.100
Extra heavy duty open front less cover
© 2014 AS America Inc.
N133
11/14
AFWALL® MILLENIUM™ FloWise®
1.1 GPF FLUSHOMETER TOILET SYSTEM
2257.712
2257.716
BARRIER FREE
3351.711
Fixture Compliance
3351.712 Certifications Meets or3351.716
Exceeds the Following Specifications:
SELECTRONIC® EXPOSED AC FLUSH VALVE
Valve Listings:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
• ASME A112.19.2-2008 / CSA B45.1-08 for
Vitreous China Fixtures
Hubbel-RACO 8192 4" ELECTRICAL BOX
OR EQUIVALENT BY CONTRACTOR
356mm
(14")
FINISHED WALL
51mm (2") HOLE
FOR CONDUIT
73mm
(2-7/8")
660mm
(26")
180˚
72mm
(2-7/8")
305mm
(12" MAX.)
15˚
SUPPLY
DN 25mm
(1" I.P.S.)
DETECTION ZONE
400mm-800mm
(15-3/4" TO 31-1/2")
86mm
(3-3/8")
409mm
(16-1/8")
45˚
470mm
(18-1/2")
-C-L-
-C-L*CRITICAL
LEVEL
C/L OF SEAT POST
HOLES 140 mm
(5-1/2") CENTER
333mm
(13-1/8")
41mm
(1-5/8")
ROUGH-IN
DIMENSION
108mm -134mm
293mm
(4-1/4" - 5-1/4")
(11-1/2")
(4) Ø 22mm
(7/8") HOLES
381mm
(15")
229mm
(9")
191mm
(7-1/2")
133mm
(5-1/4")
FINISHED
FLOOR
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be a minimum of 152mm (6") above
fixture. Consult Codes for details.
VALVE LEFT or RIGHT HAND INSTALLATION
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so that top of seat is 432 to 483mm (17" to 19") from the finished floor.
NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING
NOT RECOMMENDED).
SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON
THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR
SUPPLY ROUGHING.
CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.
These measurements are subject to change or cancellation. No responsibility is assumed
for use of superseded or voided pages
© 2014 AS America Inc.
N134
11/14