Case Study of Harmonics Analysis Pasasorn Jan-ngoen Power Quality Provincial Electricity Authority (PEA) Provincial Electricity Authority, Thailand 1 CONTENTS Problem occur in factory Definition of harmonic Harmonic assessment Harmonic assessment standard Analysis of harmonic Conclusion Provincial Electricity Authority, Thailand 2 Problem occur in factory Name: CK Cartan Company Limited, Lam phun Manufacture of paper and paper products Provincial Electricity Authority, Thailand 3 Problem occur in factory Fuse blow Magnetic Contactor failure Machine Stop Provincial Electricity Authority, Thailand kVAr Charge 4 Definition of Harmonic Harmonic is the measure of waveform distortion. Sinusoidal waveform Provincial Electricity Authority, Thailand Harmonic distortion 5 Harmonic assessment Provincial Electricity Authority, Thailand 6 Harmonic assessment Current Probe TR 2510A Dranetz PX5 Provincial Electricity Authority, Thailand 7 Harmonic assessment standard EN50160 IEEE519 IEC61000-4 G5/4 Associated standard of Harmonic PEA+MEA+EGAT The harmonic regulation for the commercial and industrial (PRC-PQG-1/1998) Provincial Electricity Authority, Thailand 8 The harmonic regulation for the commercial and industrial (PRC-PQG-02/1998) Voltage at PCC. (kV) Current distortion limits in each order(Arms) 7 8 9 10 11 12 13 14 15 16 17 18 19 48 34 22 56 11 40 9 8 7 19 6 16 5 5 5 6 4 6 11,12,22 and 24 13 8 6 10 4 8 3 3 3 7 2 6 2 2 2 2 1 1 33 11 7 5 9 4 6 3 2 2 6 2 5 2 1 1 2 1 1 69 8.8 5.9 4.3 7.3 3.3 4.9 2.3 1.6 1.6 4.9 1.6 4.3 1.6 1 1 1.6 1 1 115 and more than 5 4 3 4 2 3 1 1 1 3 1 3 1 1 1 1 1 1 0.400 2 3 4 5 6 Provincial Electricity Authority, Thailand 9 The harmonic regulation for the commercial and industrial (PRC-PQG-02/1998) Voltage at PCC. (kV) Total harmonic distortion (%) 0.400 Total harmonic distortion in each order.(THDV%) % Odd % Even 5 4 2 11,12,22 and 24 4 3 1.75 33 3 2 1 69 2.45 1.63 0.82 115 and more than 1.5 1 0.5 Provincial Electricity Authority, Thailand 10 Analysis of harmonic Provincial Electricity Authority, Thailand 11 Analysis of harmonic Total harmonic Distortion each phase compare PEA Standard between PCC. 6.00% Total harmonic distortion (%) 5.00% 5.00% PEA Standard 5.00% 5.00% PCC 4.00% 3.00% 2.11% 2.00% 1.98% 2.25% 1.00% 0.00% Phase A Provincial Electricity Authority, Thailand Phase B THDv (%) Phase C 12 Analysis of harmonic Waveform harmonics % Component of voltage harmonic each order at peak load 5th 1.5 7th 1.0 0.5 0.0 THD H03 H02 H05 H04 H07 H06 H09 H08 H11 H10 H13 H12 A VHarm B VHarm H15 H14 H17 H16 H19 H18 H21 H20 H23 H22 H25 H24 C VHarm No DFT data available C reated wi th D ranV iew 6 .15.3 Provincial Electricity Authority, Thailand 13 Analysis of harmonic current harmonic each order compare PEA Standard between PCC. 100 Current distortion limited (Arms) 90 80 87.7 75.17 PEA Standard PCC 70 62.64 60 53.24 50 40 34.45 29.75 30 25.06 24.01 20 17.23 13.76 14.09 13.75 12.53 10 1.61 0 2nd 0.97 3rd 4th 0.41 5th 6th 2.96 0.41 7th 8th 9th 10.96 9.4 7.83 4.99 0.25 10th 0.22 11th 12th 1.33 13th 0.16 14th 7.83 0.54 15th 7.83 0.15 16th 9.4 9.4 6.26 0.56 17th 0.15 18th 0.38 19th Order of harmonic Provincial Electricity Authority, Thailand 14 Analysis of harmonic Wav eform harmonics % Component of current harmonic each order at peak load 5 4 5th 3 7th 2 1 0 THD H03 H02 H05 H04 H07 H06 H09 H08 H11 H10 H13 H12 A IHarm B IHarm H15 H14 H17 H16 H19 H18 H21 H20 H23 H22 H25 H24 C IHarm No DFT data available C re ated wi th D ranV iew 6.15.3 Provincial Electricity Authority, Thailand 15 Analysis of harmonic Provincial Electricity Authority, Thailand 16 Analysis of harmonic Fuse Capacitor Bank Provincial Electricity Authority, Thailand Magnetic Contactor Failure 17 CONCLUSION In this case use the harmonic regulation for the commercial and industrial. Background of THDv and THDi following with standard. Should be installation detune, tune, active filter for improvement system. Thank you Provincial Electricity Authority, Thailand 19
© Copyright 2024 ExpyDoc