Uniseal® PVC

Technical Specifications
Technical Data
Testing Method
Test Data
Thickness
1.5mm
Tensile strength to break
EN 12311-2
≥11 N/mm2
Elongation at break
EN 12311-2
≥200%
Static puncture resistance
EN 12730 (A)
Impact resistance
EN 12691
≥600 (Hard substrate)
≥1000 (Soft substrate)
Tear resistance
EN 2310-2
≥150 N
Joint separation resistance
EN 2310-2
≥150 N
Reaction to fire
EN 13501 -1 :2002
E
(EN ISO 11925-2)
Water tightness
EN 1928 : 2000 (B)
Pass
Root Resistance
EN 13948 : 2008
Pass
*Properties (Barcelona Test)
WARRANTY
Uniseal® PVC
For warranty issues and other information, please contact the manufacturer for full details.
HIGH PUNCTURE RESISTANT // HIGH UV RESISTANT //
UNIFORM THICKNESS // EXCELLENT FLEXIBILITY
Uniseal Creative Solutions Pte Ltd
31 Mandai Estate, Innovation Place,
IMMEDIA #06-04
Singapore 729933
Tel : (65) 6755 0055
Fax: (65) 6753 1398
Email: [email protected]
www.uniseal.com.sg
Disclaimer
Information contained herein are printed to the best of our knowledge and is supported by current
available data. Subjected to the care and method of application, deviations in performance may
occur. The manufacturer is not responsible for any loss or damage arising from incorrect usages.
Our guarantee is therefore limited to the quality of the supplied materials. For more information
on the product and installation, please call Tel: (65) 6755 0055.
ISO 9001 ISO 14001 ISO 18001
Copyright reserved 2012
Greener Today For A Better
Tomorrow.”
PVC
“A
STEP. 4
STEP. 5
PRODUCT DESCRIPTION
Uniseal® PVC is a 1.5mm thick single-ply membrane with
non woven glass fibre reinforcement. The attribute of
superior performance of the membrane allows it to be used
in different type of roofs and landscape areas. Uniseal® PVC
is a durable, strong & flexible membrane that is fully
adhered to the roof surfaces.
STEP. 1
STEP. 3
STEP. 6
APPLICATION
STEP. 2
Uniseal® PVC membrane has been tested and certified as
resistance waterproofing membrane in accordance with the
UNE-EN 13948:2008 standard.
AREAS OF USAGE
All type of roof surfaces, sky gardens, environmental deck, car parks
SURFACE PREPARATION
Ensure all substrates are firm, clean, dry,
free from grease, curing compound and
any loose materials or protrusions, prior
to application.
New concrete or plastered surfaces must
be cured for a minimum 28 days.
Existing old structure surfaces must be
jet washed and allowed to dry for 2 to 3
hours prior to application (depending on
weather condition).
Cracks and joints must be repaired using
suitable compound prior to application.
SAFETY PRECAUTION
Take all safety precautions for workmen
such as helmets, goggles, protective
gloves, overalls, safety boots etc.
Unroll the membrane to achieve correct
over lapping joint and alignment prior
the hot air welding. (All side laps must
be 50mm wide and end laps 75-100mm)
PACKAGING
Roll back the membrane and start to
apply adhesive to the surfaces prior
installing the system.
COLOUR AVAILABILITY
Unroll the membrane slowly and use
the roller to remove any trap air bubbles
to achieve full bonding to the surfaces.
At all side & end laps, use the hot weld
machine to bond the 2 pcs membrane
to achieve the strong and tight over
lapping edges. (Temperature must be
controlled, do not over heat)
2.05 x 20m Roll
Grey
OCCUPATIONAL SAFETY
AND HEALTH
As high temperature machine are used
during application, extra safety procedure
need to be taken.
STORAGE
Store the membrane in sleeping position.