WLTP-AP

WLTP-06-32e
WLTP AP
WLTP-AP
VALIDATION PHASE 2
FOR SELECTED ADDITIONAL
POLLUTANTS
Status Report and Open issues
6th WLTP - Vienna, 26-28-April-2014
M C Astorga
M.C.
28 March 2014
1
WLTP (DTP) AP
WLTP-(DTP)-AP
VALIDATION PHASE-2
PHASE 2
NH3
28 March 2014
2
It is perfectly possible to measure NH3 at the exhaust with and
“on line” method with all the guaranties of reproducibility and
Repeatability of the results.
NH3
NH3 measurements in the gas phase of LD vehicles’ Exhaust
(3 instruments
i t
t have
h
been
b
validated
lid t d during
d i
VP2)
The VP2 allows to include method for NH3 in the GTR:
We have recovered the text from the last version of the GTR basically
as it was (annex 5 in point 7.1.1
7 1 1 and following).
following) Now includes the
instruments and some more precise analytical instrumentation.
A document with the information from the campaign HAS BEEN SENT
to the WLTP Chair and is now loaded @ 06-27e
28 March 2014
3
https://www2.unece.org/wiki/display/trans/WLTP+6th+session
NH3
Instrument
FTIR
(JRC)
BLAQ-Sys (CGS
QCL)
QCL-IR (HORIBA
MEXA1400QL NX)
28 March 2014
Sampling flow
(l/min)
Frequency
(Hz)
System temp
(°C)
10
1
190
1
1
Sampling 190
Analyzers 100
9
5
113
4
NH3
Table 1. Vehicles description.
p
Denomination
DV1
DV2
Combustion type
Diesel
Diesel
EU emission standard
Euro 6
After treatment
After-treatment
Fuel
Fuel system
Engine
(cm3)
displacement
Engine power (kW)
Odometer (km)
Vehicle weight (kg)
FFV
Flex-fuel
gasoline/EtOH
g
GV
Euro 5
Euro 5a
Euro 5
DPF, SCR
B5
TDI
DPF
B5
TD
TWC
E5
DI
TWC
E5
GDI
1968
1560
1596
1390
105
22362
1712
84
18871
1282
132
24334
1481
132
38541
1194
Gasoline
NH3
Fig3.
Fig3
Real time
Real-time
ammonia
emission
concentration
for
vehicles DV1,
DV1 DV2,
DV2
FFV and GV over the
WLTC measured by
HR-FTIR
HR
FTIR
(blue)
(blue),
HORIBA MEXA 1440
QL-NX (red), and CGS
BLAQ-Sys
Q y ((black).
)
NH3
Fig4. Concentration of
Fig4
ammonia measured by HRFTIR (blue), HORIBA MEXA
1440 QL
QL-NX
NX (red),
(red) and CGS
BLAQ-Sys (black), compared
with one tenth of the
concentration of ethylene,
ethylene
measured by HR-FTIR
(dotted blue) over the WLTC.
Ethylene concentration for
DV1 and DV2 is found on the
right axis.
NH3
Table 3. Average
g ammonia concentration from the four tests vehicles,, DV1,, DV2,,
FFV and GV using HR-FTIR, HORIBA MEXA 1440 QL-NX, and CGS BLAQ-Sys.
Vehicle
DV1
DV2
FFV
GV
0.5 (±0.1)
1.0
HORIBA QCLIR
0.1 (±0.1)
0.8
CGS BLAQSys
0.2 (±0.1)
6.6
Average1
0.5 (±0.1)
0.1 (±0.1)
0.2 (±0.1)
Max
Average1
Max
Average1
Max
1.0
20 (±7)
135
22.3 (±0.6)
1 0
155.0
0.5
21 (±7)
272
24 (±1)
587
8
2.0
23 (±11)
190
24 (±2)
229
Concentration
JRC HR-FTIR
Average1
Max
1Average
concentration (ppm) of the three tests performed per vehicle. Max
refers to the maximum concentration registered value (ppm) during the three
t t
tests.
3/28/2014
8
NH3 & GGTR
Date
08.03.2013
Name of the file
WLTP-2013-016 Consolidated Draft GTR
08.03.2013.docx
Modifications after
VP2 for AP
2014
Annex 5: test equipment and calibrations:
7.1.1. Extractive sampling ,,,,
7.1.1.1,,, and following
(numbers may change in the new version).
28 March 2014
9
Pg 179/ GTR version
8th MARCH 2013
7.0 Additional sampling and analysis methods
7.1. Sampling and analysis methods for NH3
NH3 sampling is done in the undiluted exhaust gas.
gas The
analyser shall be installed either within an analyser cabinet
using extractive sampling in accordance with the
instrument manufacturer
manufacturer’s
s instructions or directly in the
exhaust pipe (in-situ).
7.1.1. Extractive sampling
7.1.1.1. The sample
p p
path up-stream
p
of the analyser
y
(sampling line, pre-filter(s), pumps and valves) shall be
made of stainless steel or PTFE and shall be heated to
set point between 110 and 190 °C in order to minimize
NH3 losses and sampling artefacts. In addition, the
sampling line shall be as short as practically possible.
On manufacturers request a temperature between 110
and 133 °C can be chosen.
VP2 – NH3
D
Doc
06
06-27#
27#
1
Docs loaded in:
https://www2.unece.org/
wiki/display/trans/WLTP+
6th+session
2
VP2 for AP
RCHO & EtOH
1
2’
OPEN QUESTIONS
& NEXT STEPS for AP
(after 6th WLTP Vienna;
March 2014- Phase 1b)
RCHO sampling
system for DNPH
cartridges
“classical method”
Formaldehyde
Acetaldehyde and Ethanol
Sampling:
diluted exhaust
For Adehyde and Formaldehyde we still need confirmation
y to
that the online instrumentation is available and ready
be used
28 March 2014
12
5 ml of fresh prepared
solution of:
ELUTION OF
CARTRIGE
CH3CN / H2O milliq (50:50)
ELUTED sample
DNPH Cartridge
R
O2N
1 mLL
O
NO2
NH
NO2
R'
R'
NH2
O2N
R, R'= H or CHn
NH
N=C
R
P
The method described
has been developed on the
TURBOVAP
basis of the “compendium of Methods for the
Determination of Toxic Organic Compounds in
AmbienT Air (2nd Edition)”
EPA/625/R-96/-1-b; Compendium Method TP-11A:
Determination of Formaldehyde
in Ambient Air
U i
Using
Ab
Absorbent
b t Cartridge
C t id
Followed
F ll
db
by High
Hi h
Performance Liquid Chromatography (HPLC)
HPLC- UV
impingers for EtOH
“classical
classical method
method”
Sampling:
diluted exhaust
HORIBA continuous measurement system for EtOH: Fourier
Transform Infra-Red (FTIR) Gas Analyzer
For EtOH we still need confirmation that the online
y to be used
instrumentation is available and ready
28 March 2014
14
How to progress after 6th WLTP
Vienna March 2014
(Phase 1B)
2’
WLTP Phase 1b
Info to GTR
WLTP
5
69
6
10 11 12 1
7
Round Robin
8
9
2
3
4
5
6
Phase2 ToR
gtr informal
document
1
0
1
1
7
8
9
10 11 12 1
169
9
Formaldehyde
Acetaldehyde
EtOH
Fix organization,
p
responsibilities
and time schedule
NH3
8
73
7
168
6
NH3
68
GRPE
5
72
WP.29
4
167
3
Slight modification
2
2015
71
1
70
2014
gtr formal
document
1
1
3
2
1
4
Phase2
20
2
6th WLTP Session; Vienna 28th March 2014
Report on NH3 results from the VP2 Sept 203
Doc 06-27e
Docs loaded in:
https://www2.unece.org/wiki/display/trans/WLTP+6th+session
ttps //
u ece o g/
/d sp ay/t a s/
6t sess o
Thanks for your attention
(Questions....?)
28 March 2014
My acknowledgement to all participants in AP VP2