Technical documentation (pdf - 1646 ko)

Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
(horizontal)
34.1
CTCY-EN – 34.1-2 / 02-2014
/ CONDOR-V
(vertical)
Applications
•Water cooled condensers with liquid receiver ensure cooling,
condensation and storage of refrigerant in refrigerating and air
conditioning installations.
• They also allow storage of the refrigerant, in order to compensate
volume variations due to the opening and closing sequences of the
expansion valve.
• In CO² subcritical installations, they can be used as a liquid receiver
with exchanger to keep temperature and pressure stable.
• Heat exchange is carried out by a water circulation inside a very
high performance finned copper tubing coil.
• Energy recovery: The use of a water cooled condenser CONDOR
allows to heat with lower costs water circulating in the exchanger
(technical hot water ...)
n
Functional features
•Products are compatible with CFCs, HCFCs, HFCs, CO2s, as well as
with their associated oils and additives. Products are designed for
use of non-hazardous refrigerants from group 2 of PED 97/23/EC.
To use CARLY components with fluids of the hydrocarbon group 1
– Propane R290, Butane R600, Isobutane R600a, Propylene R1270
– with HFOs and transcritical CO2 and for a RANKINE organic cycle
application, contact CARLY technical department.
•Product classification in CE categories is done with the PED
97/23/EC table, corresponding to a volume-based selection.
• Hermetically sealed outer steel enclosure with paint to ensure a
high resistance to corrosion.
• Two ranges of water cooled condensers receivers for an
installation and an operation in horizontal position for CONDOR-H
and in vertical position for CONDOR-V.
• They are fitted with fastening means suited to their volume and
to their weight.
• They can function with tap water, river water, tower water (treated
or not), with glycol water and with refrigerants and heat transfer
fluids.
• Presence of a 3/8’’ NPT boss on the model CONDOR-V 2500,
for mounting of safety elements in accordance with the standard
EN 378-2.
Possible customization on demand:
•Depending on the application, CARLY can transform its water cooled
condensers in subcoolers.
n
CARLY advantages
•Maximum working pressure 46 bar.
• Water cooled condensers with receiver are supplied perfectly
clean and dried.
•They offer both following connection possibilities for the
refrigerant:
➜ Outside of the connections to screw.
➜ Inside of the connections to braze.
•Heat exchangers made of finned copper for very high
performance.
•Low water consumptions.
•Low pressure drop on water.
• A wide range of accessories is available:
➜ Rotalock stop valves, with connections to screw or to
braze.
➜ Rotalock connections with possibility of diameter
reductions and with connections to braze.
•Reduction of the quantity of the refrigerant in the circuit
compared to installations with air cooled condensers.
•GOST certified products.
Refrigeration & Climate Components Solutions
34.2
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
(horizontal)
CTCY-EN – 34.1-2 / 02-2014
/ CONDOR-V
(vertical)
Warning
Before selecting or installing any component, please refer to the chapter 0 - WARNING.
n
General assembly precautions
The installation of a component in
a refrigeration system by a skilled
professional, requires some precautions:
•Some are specific to each component,
and in this case, they are specified in the
n
RECOMMENDATIONS
defined hereafter ;
SPECIFIC
part
•Other are general to all CARLY components,
they are presented in the chapter 115 –
GENERAL ASSEMBLY PRECAUTIONS.
•The recommendations relating to the
CARLY components for the subcritical
CO2 applications are also developed in
chapter 115 – GENERAL ASSEMBLY
PRECAUTIONS.
Recommendations specific to the water cooled condenser with liquid receiver CONDOR
•The water cooled condensers must
be installed at the discharge of the
compressors, horizontally for models
CONDOR-H, vertically for models
CONDOR-V and in both cases, with their
feet brackets at the bottom.
•For optimal operation, refrigerant and
water flow directions should be respected
(“IN” tag at the inlet of each circuit).
•If sizing of the receivers is performed on
the basis of the total refrigerant load, it
is imperative to select receivers with an
internal volume 20 % bigger, so that the
gas reserve is always above the liquid
level.
•It is essential to ensure a water circulation
before any handling on the refrigerating
circuit (risk of freezing).
•Water circulating in the heat exchangers
can freeze:
- when the installation is running, if the
refrigerant pressure decreases
- when the installation is stopped, if the
ambient temperature drops.
It is therefore recommended to install
appropriate frost protection devices.
•Be sure to maintain a good cleanliness
of the water circuit using appropriate and
regularly changed filters.
1
Outside of the connections
to screw
2
Inside of the connections
to weld or to braze
•Use of see water strictly prohibited.
•The connections of the water cooled
condensers CONDOR have an external
screw thread (sketch 1) allowing the
assembly of isolating valves or Rotalock
connections, and an internal bore
(sketch 2) allowing the brazing of a pipe.
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
CTCY-EN – 34.1-2 / 02-2014
(horizontal)
Quick selection table
Gaz inlet
connections R1
CARLY
references
Water
Condensation
inlet W1
capacity
and
Outside of
Inside of
Outside of
Inside of
Qk
connections connections connections connections outlet W2
(1)
to screw
to braze
to screw
to braze
connections
CONDOR-H 150
CONDOR-H 250
CONDOR-H 500
CONDOR-H 750
CONDOR-H 1000
(1)
34.3
Liquid outlet
connections R2
Water
flow
Water
pressure
drop
Volume
of refrigerant
Maximum
storage
Without
subcooling
UNF
inch
ODF
inch
UNF
inch
ODF
inch
mm
kW
m3/h
bar
L
L
3/4
3/4
1
1
1
3/8
3/8
1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
3/8
3/8
3/8
3/8
3/8
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
1,45
2,46
5,00
7,50
9,90
0,10
0,20
0,25
0,30
0,40
0,01
0,02
0,06
0,12
0,16
2,9
2,9
4,9
4,1
6,3
0,27
0,27
0,32
0,41
0,41
Refrigerant R404A ; Δt1 = 25 K ;
Δt1 = Condensing temperature - Water inlet temperature
n
Technical features
Dimensions mm
CARLY
references
Ø1
Ø2
CONDOR-H 150
CONDOR-H 250
CONDOR-H 500
CONDOR-H 750
CONDOR-H 1000
121,0
121,0
152,4
121,0
152,4
128
128
156
128
156
Ø3
4 x Ø6,5 x 10
4 x Ø6,5 x 10
2 x Ø9 x 5,5
4 x Ø6,5 x 10
2 x Ø9 x 5,5
L1
L2
L3
L4
L5
L6
E1
E2
E3
E4
E5
E6
405
405
453
531
565
371
371
387
497
499
34
34
66
34
66
340
340
442
340
442
80
80
40
80
40
227
227
257
227
257
230
230
218
360
348
66
66
80
68
71
4
4
10
4
10
40
40
70
40
70
300
300
410
300
410
60
60
/
60
/
L1
L2
E2
E4
W1
L3
E1
R1
W2
R2
E3
45°
Ø2
L6
E6
L5
1
E5
L4
Ø3
Refrigeration & Climate Components Solutions
34.4
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
CONDOR-H 150
CONDOR-H 250
CONDOR-H 500
CONDOR-H 750
CONDOR-H 1000
n
(horizontal)
Technical features
CARLY
references
(1)
CTCY-EN – 34.1-2 / 02-2014
Maximal
working
pressure
Heat exchanger
maximal
working
pressure
Maximal
working
temperature
Minimal
working
temperature
Working
temperature
V
PS
PS Ech.
TS maxi
TS mini
TS BT
L
bar
bar
°C
°C
°C
3,4
3,2
5,8
4,0
7,4
46
46
46
46
46
10
10
10
10
10
120
120
120
120
120
-20
-20
-20
-20
-20
/
/
/
/
/
Volume
CE
Category
(1)
I
I
II
I
II
Classification by volume, according to PED 97/23/EC (refer to chapter 0).
Example of selection of a CONDOR water cooled condenser with liquid receiver
The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature pressure refrigerant oil external environment). The values of the selection tables proposed in the CARLY catalogue match accurate test
conditions.
• Installation operating with R404A under the following conditions(1):
➜ Qkx = 7 kW
➜ Tk = 40 °C
➜ Tl1 = 20 °C
––––>
Δt1 = 40 - 20 = 20K
➜ Maximum water flow = 500 l/h
➜ Normal city water
• Which water cooled condenser CONDOR to choose?
1° Make corrections according to the water and the refrigerantes:
- 1-1 Correction according to fouling factor Fe (refer to page 34.5)
- 1-2 Correction according to refrigerant Fr (refer to page 34.5)
Result: Qk = Qkx x Fe x Fr = 7 kW
2° Report the capacity to the quick selection table, page 34.5
3° Report the maximum water flow to the quick selection table, page 34.5
4° Select the CONDOR H model.
Result:
(1)
CONDOR H -1000
––––>
Δt1 = 18K
CONDOR H -500
––––>
Δt1 = 25K
CONDOR H -750
Chapter «Abbreviations and units» (refer to chapter 113).
––––>
Δt1 = 20K
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
34.5
CTCY-EN – 34.1-2 / 02-2014
(horizontal)
Technical features
• According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the
fouling factor by the formula:
Qk = Qkx x Fe
Water type
Normal city water
Treated tower water
Untreated tower water
River water
Glycol water below 40 %
Glycol water below 70 %
Fouling factor
m2.K / W
Correction factor
Fe
43.10-6
43.10-6
86.10-6
86.10-6
86.10-6
172.10-6
1,00
1,00
1,19
1,19
1,19
1,56
• According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the
following Fr factor by the formula:
Qk = Qkx x Fr
Correction factor
Fr
Refrigerant
R404A / R507
R 22 / R410A / R407F
R134a / R407C
n
1,00
0,92
0,85
Quick Selection Table
16
ND
14
CO
12
Capacity kW
750
-H
00
-H 5
R
DO
N
00
10
R
DO
N
CO
CO
10
8
6
CONDOR-H
4
2
0
15K ≤ Δt1 ≤ 25K
-H
OR
200
250
CONDOR-H 150
400
Water flow l/h
600
800
Refrigeration & Climate Components Solutions
34.6
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
CTCY-EN – 34.1-2 / 02-2014
(horizontal)
Spares parts and options
3
2
1
4
CONDOR H (1)
CARLY
references
Part N°
150 - 250 - 500(S) 750(S) - 1000(S)
CY 15580100
1
1/4” et 3/8”
500(E) - 750(E) 1000(E)
CY 15580140
1
1/2”
(1)
B
inch
(E) = Inlet, (S) = Outlet
CONDOR H
A
Flat gasket for valves and ROTALOCK connections
(1)
CARLY
references
ROTALOCK connections, gasket included
Part N° ØA outlet ODF connection ØB fixing UNF connector
inch
inch
150 - 250 - 500(S) CY 17400000
750(S) - 1000(S)
2
1/4
3/4
150 - 250 - 500(S) CY 17400010
750(S) - 1000(S)
2
3/8
3/4
500(E) - 750(E) 1000(E)
2
1/2
1
(1)
CY 17400020
(E) = Inlet, (S) = Outlet
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-H
n
CTCY-EN – 34.1-2 / 02-2014
(horizontal)
Spares parts and options
CONDOR H (1)
A
B
B
3
3/8
3/4
500(E) - 750(E) 1000(E)
3
1/2
1
CY 19700120
(E) = Inlet, (S) = Outlet
CARLY
references
ROTALOCK valve with connection to screw, gasket included
Part N°
ØA outlet SAE valve
ØB fixing UNF valve
inch
inch
150 - 250 - 500(S) CY 19700090
750(S) - 1000(S)
3
1/4
3/4
150 - 250 - 500(S) CY 19700100
750(S) - 1000(S)
3
3/8
3/4
500(E) - 750(E) 1000(E)
3
1/2
1
CY 19700140
(E) = Inlet, (S) = Outlet
150 - 250 - 750
500 - 1000
CARLY
references
Part N°
Description
CY 37100210
CY 37100220
4
4
Support feet
Support feet
CY 37100220
Weights and packaging
Pièces détachées CONDOR-H -- CY 37100210
Unit weight
kg
Packaging
Without
packaging
5,20
8,20
11,00
7,20
14,00
inch
150 - 250 - 500(S) CY 19700110
750(S) - 1000(S)
CONDOR H
CONDOR-H 150
5,65
CONDOR-H 250
8,65
Pièces détachées CONDOR-H -- CY 37100210
CONDOR-H
500
11,30
CONDOR-H 750
7,65
CONDOR-H 1000
14,30
ØB fixing UNF valve
inch
3/4
CY 37100210
With
packaging
ØA outlet ODF valve
1/4
(1)
CARLY
references
ROTALOCK valve with connection to solder, gasket included
Part N°
3
CONDOR H (1)
A
CARLY
references
150 - 250 - 500(S) CY 19700080
750(S) - 1000(S)
(1)
n
34.7
number of pieces
1
1
1
1
1
Refrigeration & Climate Components Solutions
34.8
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
CARLY
references
CONDOR-V 100
CONDOR-V 150
CONDOR-V 240
CONDOR-V 500
CONDOR-V 1000
CONDOR-V 1400
CONDOR-V 2500
(2)
(vertical)
Selection table
Gaz inlet
connections R1
(1)
CTCY-EN – 34.1-2 / 02-2014
Liquid outlet
connections R2
Water
Condensation
inlet W1
capacity
and
Outside of
Inside of
Outside of
Inside of
Qk
connections connections connections connections outlet W2
to screw
to braze
to screw
to braze
connections
UNF
inch
ODF
inch
UNF
inch
ODF
inch
mm
kW
3/4
3/4
3/4
1
1 1/4
1 1/4
1 3/4
3/8
3/8
3/8
1/2
5/8
5/8
7/8
3/4
3/4
3/4
3/4
1
1
1 1/4
3/8
3/8
3/8
3/8
1/2
1/2
5/8
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
G 3/4 M
1,11
1,52 (1)
2,39 (1)
4,90 (1)
9,82 (1)
14,56 (2)
25,50 (2)
Refrigerant R404A ; Δt1 = 20 K ;
Refrigerant R404A ; Δt1 = 25 K ;
Δt1 = Condensing temperature - Water inlet temperature
For more details on the selection of condensers, refer to pages 34-10 to 34-15.
(1)
Water
flow
Water
pressure
drop
Volume
of refrigerant
Maximum
storage
Without
subcooling
m3/h
bar
L
L
0,10
0,10
0,20
0,30
0,50
0,80
1,60
0,01
0,01
0,02
0,07
0,25
0,53
0,37
2,0
2,7
2,7
6,1
7,7
3,1
13,0
1,00
1,80
1,70
2,50
2,50
0,70
3,50
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
34.9
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Technical features
Dimensions mm
CARLY
references
Drawing
Nb
Ø1
Ø2
L1
L2
L3
L4
E1
E2
E3
E4
Ø3
Ø4
CONDOR-V 100
CONDOR-V 150
CONDOR-V 240
CONDOR-V 500
CONDOR-V 1000
CONDOR-V 1400
CONDOR-V 2500
1
1
1
2
2
3
4
121,0
121,0
121,0
152,4
152,4
121,0
219,1
128
128
128
156
156
128
224
341
412
412
535
645
472
553
319
390
390
514
624
450
/
14
14
14
17
23
23
23
88
88
88
108
114
73
117
145
220
220
330
430
288
290
73
73
73
79
79
64
132
10
10
10
15
15
10
15
40
40
40
70
70
40
150
M10
M10
M10
M12
M12
M10
3 x 10.2 x 15
/
/
/
/
/
/
200
1
2
L4
L4
Ø2
Ø2
E3
E3
W1
W1
R1
R1
E4
E4
W2
W2
L1
L2
L3
L3
E1
L1
L2
E1
Ø1
E2
Ø1
R2
9,5
E2
43
R2
9,5
Ø3
140
Patte deSupport
fixation 160
140 x 40
feetx160
CY 37100200 en option
160
Ø2
Patte de fixation 160 x 140
CY 37100200
(option)
CY 37100200
en option
160
4
E3
L4
Ø2
W2
R1
E3
3/8 NPTF
W1
E4
E4
W1
R1
L3
L2
Support feet 160 x 40
140
CY 37100200 (option)
L4
3
L1
39
Ø3
L3
E1
L1
W2
E1
Ø1
Ø1
Ø3
E2
R2
E2
Ø4
9,5 43
Ø3
140
160
R2
Patte deSupport
fixation 160
140x 40
feetx160
CY 37100200 en option
CY 37100200 (option)
Schema cotat
Refrigeration & Climate Components Solutions
34.10
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
CONDOR-V 100
CONDOR-V 150
CONDOR-V 240
CONDOR-V 500
CONDOR-V 1000
CONDOR-V 1400
CONDOR-V 2500
n
(vertical)
Technical features
CARLY
references
(1)
CTCY-EN – 34.1-2 / 02-2014
Maximal
working
pressure
Heat exchanger
maximal
working
pressure
Maximal
working
temperature
Minimal
working
temperature
Working
temperature
V
PS
PS Ech.
TS maxi
TS mini
TS BT
L
bar
bar
°C
°C
°C
2,6
3,4
3,2
7,4
8,9
3,2
15,1
46
46
46
46
46
46
45
10
10
10
10
10
10
10
120
120
120
120
120
120
120
-20
-20
-20
-20
-20
-20
-20
/
/
/
/
/
/
/
Volume
CE
Category
(1)
I
I
I
II
II
I
II
Classification by volume, according to PED 97/23/EC (refer to chapter 0).
Example of selection of a CONDOR water cooled condenser with liquid receiver
The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature pressure refrigerant oil external environment). The values of the selection tables proposed in the CARLY catalogue match accurate test
conditions.
• Installation operating with R404A under the following conditions(1):
➜ Qkx = 10 kW
➜ Tk = 40 °C
➜ Tl1 = 20 °C
––––>
Δt1 = 40 - 20 = 20K
➜ Maximum water flow = 500 l/h
➜ Normal city water
• Which water cooled condenser CONDOR to choose?
1° Make corrections according to the water and the refrigerantes:
- 1-1 Correction according to fouling factor Fe (refer to page 34.11)
- 1-2 Correction according to refrigerant Fr (refer to page 34.11)
Result: Qk = Qkx x Fe x Fr =10 kW
2° Report the capacity to the quick selection table, page 34.11, and take note of possible condensers.
Result: CONDOR-V 500, CONDOR-V 1000, CONDOR-V 1400, CONDOR-V 2500
3° Search on the condenser feature curves, pages 34-6 to 34-9, the most suitable condenser.
Result:
- CONDOR V-500 works with Δt1 of 25K (page 34-13)
(does not match because Δt1 > 20K).
- CONDOR V-1000 matches perfectly (page 34-14).
- CONDOR V-1400 works with a water flow of 700 l/h (page 34-14)
(does not match because water flow > 500 l/h)
- CONDOR V-2500 is too powerful because Δt1 < 20K (page 34-15).
4° Select the CONDOR V-1000 model and determine on the curves the water Δt and the water pressure drop (page 34-14).
Result:
(1)
Δt water = 16,5K
Δp water = 0,25 bar
Chapter «Abbreviations and units» (refer to chapter 113).
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
34.11
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Technical features
• According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the
fouling factor by the formula:
Qk = Qkx x Fe
Water type
Normal city water
Treated tower water
Untreated tower water
River water
Glycol water below 40 %
Glycol water below 70 %
Fouling factor
m2.K / W
Correction factor
Fe
43.10-6
43.10-6
86.10-6
86.10-6
86.10-6
172.10-6
1,00
1,00
1,19
1,19
1,19
1,56
• According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the
following Fr factor by the formula:
Qk = Qkx x Fr
Correction factor
Fr
Refrigerant
R404A / R507
R 22 / R410A / R407F
R134a / R407C
Quick Selection Table
20
15
Capacity kW
n
1,00
0,92
0,85
10
5
0
0
200
400
Water flow l/h
600
800
1 000
Refrigeration & Climate Components Solutions
34.12
Water cooled condensers
with liquid receiver
C
CONDOR-V
(vertical)
Technical features
3
CONDOR-V 100
Dt eau = 5K
Dt eau = 3K
0,14
2,5
0,12
0,1
Puissance (kW)
Capacity kW
Dt1 = 20K
0,08
1,5
Dt1 = 15K
0,06
1
Dt eau = 1K
Perte de cherge eau (bar)
Dp eau
2
Water pressure drop bar
Dt1 = 25K
0,04
Dt1 = 10K
0,5
0,02
0
0
100
200
300
400
500
600
700
800
Débit eau (l.h-1)
Water
flow l/h
4
CONDOR-V 150
Dt eau = 10K
0,16
Dt eau = 5K
3,5
0,14
Dp eau
Dt1 = 25K
0,12
Puissance (kW)
2,5
Dt1 = 20K
2
Dt1 = 15K
Dt1 = 10K
1,5
Dt1 = 5K
1
0,1
0,08
0,06
0,04
Dt eau = 1K
0,5
0,02
0
0
100
200
300
400
500
Débit eau
Water
flow(l.h-1)
l/h
600
700
800
Perte de charge eau (bar)
Dt eau = 3K
Water pressure drop bar
3
Capacity kW
n
CTCY-EN – 34.1-2 / 02-2014
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-V
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Technical features
6
CONDOR-V 240
0,18
Dt eau = 15K
Dt eau = 10K
Dp eau
0,16
5
0,12
Puissance (kW)
Capacity kW
Dt1 = 25K
Dt1 = 20K
3
Dt eau = 3K
Dt1 = 15K
2
0,1
0,08
0,06
Perte de charge eau (bar)
Dt eau = 5K
4
Water pressure drop bar
0,14
Dt1 = 10K
0,04
Dt eau = 1K
1
Dt1 = 5K
0
0,02
0
100
200
300
400
500
600
700
800
Débit eau (l.h-1)
Water flow l/h
12
CONDOR-V 500
0,4
Dt eau = 15K
Dt1 = 25K
0,35
10
Dt1 = 20K
0,25
Dt1 = 15K
6
0,2
Dt1 = 10K
Dt eau = 5K
4
0,15
0,1
2
Dt1 = 5K
0
0,05
0
100
200
300
400
500
Débit eau (l.h-1)
Water flow l/h
600
700
800
Perte de charge eau (bar)
8
Water pressure drop bar
0,3
Dt eau = 10K
Capacity
kW
Puissance (kW)
n
34.13
Refrigeration & Climate Components Solutions
34.14
Water cooled condensers
with liquid receiver
C
CONDOR-V
(vertical)
Technical features
24
CONDOR-V 1000
0,6
Dp eau
22
18
Dt eau = 20K
16
Dt1 = 25K
14
Dt1 = 20K
Dt eau = 15K
12
0,4
0,3
Dt1 = 15K
10
Dt eau = 10K 0,2
8
6
Water pressure drop bar
0,5
Perte de charge eau (bar)
Puissance (kW)
Capacity kW
20
Dt1 = 10K
4
Dt eau = 5K
0,1
2
0
0
100
200
300
400
500
600
700
800
Débit eau (l.h-1)
Water
flow l/h
18
CONDOR-V 1400
0,6
Dt eau = 20K
Dp eau
0,5
Dt eau = 15K
12
0,4
Dt1 = 20K
Puissance (kW)
10
Dt eau = 10K
8
0,3
Dt1 = 15K
Dt1 = 10K
6
4
Dt eau = 5K
0,2
0,1
Dt1 = 5K
2
0
0
100
200
300
400
500
Débit eau (l.h-1)
Water flow l/h
600
700
800
Water pressure drop bar
Dt1 = 25K
14
Perte de charge eau (bar)
16
Capacity kW
n
CTCY-EN – 34.1-2 / 02-2014
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-V
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Technical features
30
CONDOR-V 2500
0,5
Dt eau = 20K
28
Dt eau = 15K
0,45
26
Dt1 = 25K
Dp eau
24
0,4
Dt1 = 20K
0,3
18
Dt eau = 10K
16
Dt1 = 15K
14
0,25
0,2
12
Dt1 = 10K
10
0,15
8
Dt eau = 5K
0,1
6
4
Dt1 = 5K
0,05
2
0
0
600
800
1000
1200
1400
Débit eau (l.h-1)
Water
flow l/h
1600
Perte de charge eau (bar)
0,35
20
Water pressure drop bar
22
Capacity
kW
Puissance (kW)
n
34.15
Refrigeration & Climate Components Solutions
34.16
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Spare parts and options
2
1
3
4
CONDOR V (1)
CARLY
references
100 - 150 - 240 - 500(S) CY 15580100
1000(E)-1400(E)-2500(S) CY 15580120
500(E)-1000 (S)-1400(S) CY 15580140
(1)
A
B
Gasket for ROTALOCK connections and valves
inch
1
1
1
1/4, 3/8
5/8, 7/8, 1 1/8
1/2
(E) = Inlet, (S) = Outlet
CONDOR V
(1)
100 - 150 - 240 - 500(S)
100 - 150 - 240 - 500(S)
500(E)-1000(S)-1400(S)
1000(E)-1400(E)-2500(S)
1000(E)-1400(E)-2500(S)
1000(E)-1400(E)-2500(S)
(1)
Part N°
CARLY
references
CY 17400000
CY 17400010
CY 17400020
CY 17400035
CY 17400040
CY 17400050
(E) = Inlet, (S) = Outlet
ROTALOCK connections, gasket included
Part N° ØA outlet ODF connection ØB fixing UNF connector
2
2
2
2
2
2
inch
inch
1/4
3/8
1/2
5/8
7/8
1 1/8
3/4
3/4
1
1 1/4
1 1/4
1 1/4
Refrigeration & Climate Components Solutions
Water cooled condensers
with liquid receiver
C
CONDOR-V
n
CTCY-EN – 34.1-2 / 02-2014
(vertical)
Spare parts and options
CONDOR V (1)
100 - 150 - 240 - 500(S)
100 - 150 - 240 - 500(S)
500(E)-1000(S)-1400(S)
500(E)-1000(S)-1400(S)
1000(E)-1400(E)-2500(S)
1000(E)-1400(E)-2500(S)
1000(E)-1400(E)-2500(S)
A
B
(1)
A
Part N°
CY 19700080
CY 19700110
CY 19700120
CY 19700130
CY 19700135
CY 19700160
CY 19700170
3
3
3
3
3
3
3
CARLY
references
100 - 150 - 240 - 500(S) CY 19700090
100 - 150 - 240 - 500(S) CY 19700100
500(E)-1000(S)-1400(S) CY 19700140
B
(1)
ROTALOCK valve with connection to solder, gasket included
CARLY
references
ØA outlet ODF valve
ØB fixing UNF valve
1/4
3/8
1/2
5/8
5/8
7/8
1 1/8
3/4
3/4
1
1
1 1/4
1 1/4
1 1/4
inch
inch
(E) = Inlet, (S) = Outlet
CONDOR V (1)
n
34.17
ROTALOCK valve with connection to screw, gasket included
Part N°
ØB fixing SAE valve
ØB fixing UNF valve
1/4
3/8
1/2
3/4
3/4
1
inch
3
3
3
inch
(E) = Inlet, (S) = Outlet
CONDOR V
CARLY
references
Part N°
Description
100 - 150 - 240 - 500 1000 - 1400
CY 37100200
4
Support feet
Weights and packaging
Unit weight
kg
CARLY
references
With
Without
Pièces détachées CONDOR-V : CY 37100200
packaging
packaging
CONDOR-V 100
CONDOR-V 150
CONDOR-V 240
CONDOR-V 500
4,50
5,65
5,65
11,10
Unit weight
Packaging
4,20
5,20
5,20
10,80
number of pieces
1
1
1
1
CARLY
references
CONDOR-V 1000
CONDOR-V 1400
CONDOR-V 2500
kg
Packaging
With
packaging
Without
packaging
number of pieces
14,30
7,65
26,10
14,00
7,20
25,50
1
1
1