Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-H n (horizontal) 34.1 CTCY-EN – 34.1-2 / 02-2014 / CONDOR-V (vertical) Applications •Water cooled condensers with liquid receiver ensure cooling, condensation and storage of refrigerant in refrigerating and air conditioning installations. • They also allow storage of the refrigerant, in order to compensate volume variations due to the opening and closing sequences of the expansion valve. • In CO² subcritical installations, they can be used as a liquid receiver with exchanger to keep temperature and pressure stable. • Heat exchange is carried out by a water circulation inside a very high performance finned copper tubing coil. • Energy recovery: The use of a water cooled condenser CONDOR allows to heat with lower costs water circulating in the exchanger (technical hot water ...) n Functional features •Products are compatible with CFCs, HCFCs, HFCs, CO2s, as well as with their associated oils and additives. Products are designed for use of non-hazardous refrigerants from group 2 of PED 97/23/EC. To use CARLY components with fluids of the hydrocarbon group 1 – Propane R290, Butane R600, Isobutane R600a, Propylene R1270 – with HFOs and transcritical CO2 and for a RANKINE organic cycle application, contact CARLY technical department. •Product classification in CE categories is done with the PED 97/23/EC table, corresponding to a volume-based selection. • Hermetically sealed outer steel enclosure with paint to ensure a high resistance to corrosion. • Two ranges of water cooled condensers receivers for an installation and an operation in horizontal position for CONDOR-H and in vertical position for CONDOR-V. • They are fitted with fastening means suited to their volume and to their weight. • They can function with tap water, river water, tower water (treated or not), with glycol water and with refrigerants and heat transfer fluids. • Presence of a 3/8’’ NPT boss on the model CONDOR-V 2500, for mounting of safety elements in accordance with the standard EN 378-2. Possible customization on demand: •Depending on the application, CARLY can transform its water cooled condensers in subcoolers. n CARLY advantages •Maximum working pressure 46 bar. • Water cooled condensers with receiver are supplied perfectly clean and dried. •They offer both following connection possibilities for the refrigerant: ➜ Outside of the connections to screw. ➜ Inside of the connections to braze. •Heat exchangers made of finned copper for very high performance. •Low water consumptions. •Low pressure drop on water. • A wide range of accessories is available: ➜ Rotalock stop valves, with connections to screw or to braze. ➜ Rotalock connections with possibility of diameter reductions and with connections to braze. •Reduction of the quantity of the refrigerant in the circuit compared to installations with air cooled condensers. •GOST certified products. Refrigeration & Climate Components Solutions 34.2 Water cooled condensers with liquid receiver C CONDOR-H n (horizontal) CTCY-EN – 34.1-2 / 02-2014 / CONDOR-V (vertical) Warning Before selecting or installing any component, please refer to the chapter 0 - WARNING. n General assembly precautions The installation of a component in a refrigeration system by a skilled professional, requires some precautions: •Some are specific to each component, and in this case, they are specified in the n RECOMMENDATIONS defined hereafter ; SPECIFIC part •Other are general to all CARLY components, they are presented in the chapter 115 – GENERAL ASSEMBLY PRECAUTIONS. •The recommendations relating to the CARLY components for the subcritical CO2 applications are also developed in chapter 115 – GENERAL ASSEMBLY PRECAUTIONS. Recommendations specific to the water cooled condenser with liquid receiver CONDOR •The water cooled condensers must be installed at the discharge of the compressors, horizontally for models CONDOR-H, vertically for models CONDOR-V and in both cases, with their feet brackets at the bottom. •For optimal operation, refrigerant and water flow directions should be respected (“IN” tag at the inlet of each circuit). •If sizing of the receivers is performed on the basis of the total refrigerant load, it is imperative to select receivers with an internal volume 20 % bigger, so that the gas reserve is always above the liquid level. •It is essential to ensure a water circulation before any handling on the refrigerating circuit (risk of freezing). •Water circulating in the heat exchangers can freeze: - when the installation is running, if the refrigerant pressure decreases - when the installation is stopped, if the ambient temperature drops. It is therefore recommended to install appropriate frost protection devices. •Be sure to maintain a good cleanliness of the water circuit using appropriate and regularly changed filters. 1 Outside of the connections to screw 2 Inside of the connections to weld or to braze •Use of see water strictly prohibited. •The connections of the water cooled condensers CONDOR have an external screw thread (sketch 1) allowing the assembly of isolating valves or Rotalock connections, and an internal bore (sketch 2) allowing the brazing of a pipe. Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-H n CTCY-EN – 34.1-2 / 02-2014 (horizontal) Quick selection table Gaz inlet connections R1 CARLY references Water Condensation inlet W1 capacity and Outside of Inside of Outside of Inside of Qk connections connections connections connections outlet W2 (1) to screw to braze to screw to braze connections CONDOR-H 150 CONDOR-H 250 CONDOR-H 500 CONDOR-H 750 CONDOR-H 1000 (1) 34.3 Liquid outlet connections R2 Water flow Water pressure drop Volume of refrigerant Maximum storage Without subcooling UNF inch ODF inch UNF inch ODF inch mm kW m3/h bar L L 3/4 3/4 1 1 1 3/8 3/8 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 3/8 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF 1,45 2,46 5,00 7,50 9,90 0,10 0,20 0,25 0,30 0,40 0,01 0,02 0,06 0,12 0,16 2,9 2,9 4,9 4,1 6,3 0,27 0,27 0,32 0,41 0,41 Refrigerant R404A ; Δt1 = 25 K ; Δt1 = Condensing temperature - Water inlet temperature n Technical features Dimensions mm CARLY references Ø1 Ø2 CONDOR-H 150 CONDOR-H 250 CONDOR-H 500 CONDOR-H 750 CONDOR-H 1000 121,0 121,0 152,4 121,0 152,4 128 128 156 128 156 Ø3 4 x Ø6,5 x 10 4 x Ø6,5 x 10 2 x Ø9 x 5,5 4 x Ø6,5 x 10 2 x Ø9 x 5,5 L1 L2 L3 L4 L5 L6 E1 E2 E3 E4 E5 E6 405 405 453 531 565 371 371 387 497 499 34 34 66 34 66 340 340 442 340 442 80 80 40 80 40 227 227 257 227 257 230 230 218 360 348 66 66 80 68 71 4 4 10 4 10 40 40 70 40 70 300 300 410 300 410 60 60 / 60 / L1 L2 E2 E4 W1 L3 E1 R1 W2 R2 E3 45° Ø2 L6 E6 L5 1 E5 L4 Ø3 Refrigeration & Climate Components Solutions 34.4 Water cooled condensers with liquid receiver C CONDOR-H n CONDOR-H 150 CONDOR-H 250 CONDOR-H 500 CONDOR-H 750 CONDOR-H 1000 n (horizontal) Technical features CARLY references (1) CTCY-EN – 34.1-2 / 02-2014 Maximal working pressure Heat exchanger maximal working pressure Maximal working temperature Minimal working temperature Working temperature V PS PS Ech. TS maxi TS mini TS BT L bar bar °C °C °C 3,4 3,2 5,8 4,0 7,4 46 46 46 46 46 10 10 10 10 10 120 120 120 120 120 -20 -20 -20 -20 -20 / / / / / Volume CE Category (1) I I II I II Classification by volume, according to PED 97/23/EC (refer to chapter 0). Example of selection of a CONDOR water cooled condenser with liquid receiver The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature pressure refrigerant oil external environment). The values of the selection tables proposed in the CARLY catalogue match accurate test conditions. • Installation operating with R404A under the following conditions(1): ➜ Qkx = 7 kW ➜ Tk = 40 °C ➜ Tl1 = 20 °C ––––> Δt1 = 40 - 20 = 20K ➜ Maximum water flow = 500 l/h ➜ Normal city water • Which water cooled condenser CONDOR to choose? 1° Make corrections according to the water and the refrigerantes: - 1-1 Correction according to fouling factor Fe (refer to page 34.5) - 1-2 Correction according to refrigerant Fr (refer to page 34.5) Result: Qk = Qkx x Fe x Fr = 7 kW 2° Report the capacity to the quick selection table, page 34.5 3° Report the maximum water flow to the quick selection table, page 34.5 4° Select the CONDOR H model. Result: (1) CONDOR H -1000 ––––> Δt1 = 18K CONDOR H -500 ––––> Δt1 = 25K CONDOR H -750 Chapter «Abbreviations and units» (refer to chapter 113). ––––> Δt1 = 20K Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-H n 34.5 CTCY-EN – 34.1-2 / 02-2014 (horizontal) Technical features • According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the fouling factor by the formula: Qk = Qkx x Fe Water type Normal city water Treated tower water Untreated tower water River water Glycol water below 40 % Glycol water below 70 % Fouling factor m2.K / W Correction factor Fe 43.10-6 43.10-6 86.10-6 86.10-6 86.10-6 172.10-6 1,00 1,00 1,19 1,19 1,19 1,56 • According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the following Fr factor by the formula: Qk = Qkx x Fr Correction factor Fr Refrigerant R404A / R507 R 22 / R410A / R407F R134a / R407C n 1,00 0,92 0,85 Quick Selection Table 16 ND 14 CO 12 Capacity kW 750 -H 00 -H 5 R DO N 00 10 R DO N CO CO 10 8 6 CONDOR-H 4 2 0 15K ≤ Δt1 ≤ 25K -H OR 200 250 CONDOR-H 150 400 Water flow l/h 600 800 Refrigeration & Climate Components Solutions 34.6 Water cooled condensers with liquid receiver C CONDOR-H n CTCY-EN – 34.1-2 / 02-2014 (horizontal) Spares parts and options 3 2 1 4 CONDOR H (1) CARLY references Part N° 150 - 250 - 500(S) 750(S) - 1000(S) CY 15580100 1 1/4” et 3/8” 500(E) - 750(E) 1000(E) CY 15580140 1 1/2” (1) B inch (E) = Inlet, (S) = Outlet CONDOR H A Flat gasket for valves and ROTALOCK connections (1) CARLY references ROTALOCK connections, gasket included Part N° ØA outlet ODF connection ØB fixing UNF connector inch inch 150 - 250 - 500(S) CY 17400000 750(S) - 1000(S) 2 1/4 3/4 150 - 250 - 500(S) CY 17400010 750(S) - 1000(S) 2 3/8 3/4 500(E) - 750(E) 1000(E) 2 1/2 1 (1) CY 17400020 (E) = Inlet, (S) = Outlet Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-H n CTCY-EN – 34.1-2 / 02-2014 (horizontal) Spares parts and options CONDOR H (1) A B B 3 3/8 3/4 500(E) - 750(E) 1000(E) 3 1/2 1 CY 19700120 (E) = Inlet, (S) = Outlet CARLY references ROTALOCK valve with connection to screw, gasket included Part N° ØA outlet SAE valve ØB fixing UNF valve inch inch 150 - 250 - 500(S) CY 19700090 750(S) - 1000(S) 3 1/4 3/4 150 - 250 - 500(S) CY 19700100 750(S) - 1000(S) 3 3/8 3/4 500(E) - 750(E) 1000(E) 3 1/2 1 CY 19700140 (E) = Inlet, (S) = Outlet 150 - 250 - 750 500 - 1000 CARLY references Part N° Description CY 37100210 CY 37100220 4 4 Support feet Support feet CY 37100220 Weights and packaging Pièces détachées CONDOR-H -- CY 37100210 Unit weight kg Packaging Without packaging 5,20 8,20 11,00 7,20 14,00 inch 150 - 250 - 500(S) CY 19700110 750(S) - 1000(S) CONDOR H CONDOR-H 150 5,65 CONDOR-H 250 8,65 Pièces détachées CONDOR-H -- CY 37100210 CONDOR-H 500 11,30 CONDOR-H 750 7,65 CONDOR-H 1000 14,30 ØB fixing UNF valve inch 3/4 CY 37100210 With packaging ØA outlet ODF valve 1/4 (1) CARLY references ROTALOCK valve with connection to solder, gasket included Part N° 3 CONDOR H (1) A CARLY references 150 - 250 - 500(S) CY 19700080 750(S) - 1000(S) (1) n 34.7 number of pieces 1 1 1 1 1 Refrigeration & Climate Components Solutions 34.8 Water cooled condensers with liquid receiver C CONDOR-V n CARLY references CONDOR-V 100 CONDOR-V 150 CONDOR-V 240 CONDOR-V 500 CONDOR-V 1000 CONDOR-V 1400 CONDOR-V 2500 (2) (vertical) Selection table Gaz inlet connections R1 (1) CTCY-EN – 34.1-2 / 02-2014 Liquid outlet connections R2 Water Condensation inlet W1 capacity and Outside of Inside of Outside of Inside of Qk connections connections connections connections outlet W2 to screw to braze to screw to braze connections UNF inch ODF inch UNF inch ODF inch mm kW 3/4 3/4 3/4 1 1 1/4 1 1/4 1 3/4 3/8 3/8 3/8 1/2 5/8 5/8 7/8 3/4 3/4 3/4 3/4 1 1 1 1/4 3/8 3/8 3/8 3/8 1/2 1/2 5/8 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF G 3/4 M 1,11 1,52 (1) 2,39 (1) 4,90 (1) 9,82 (1) 14,56 (2) 25,50 (2) Refrigerant R404A ; Δt1 = 20 K ; Refrigerant R404A ; Δt1 = 25 K ; Δt1 = Condensing temperature - Water inlet temperature For more details on the selection of condensers, refer to pages 34-10 to 34-15. (1) Water flow Water pressure drop Volume of refrigerant Maximum storage Without subcooling m3/h bar L L 0,10 0,10 0,20 0,30 0,50 0,80 1,60 0,01 0,01 0,02 0,07 0,25 0,53 0,37 2,0 2,7 2,7 6,1 7,7 3,1 13,0 1,00 1,80 1,70 2,50 2,50 0,70 3,50 Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-V n 34.9 CTCY-EN – 34.1-2 / 02-2014 (vertical) Technical features Dimensions mm CARLY references Drawing Nb Ø1 Ø2 L1 L2 L3 L4 E1 E2 E3 E4 Ø3 Ø4 CONDOR-V 100 CONDOR-V 150 CONDOR-V 240 CONDOR-V 500 CONDOR-V 1000 CONDOR-V 1400 CONDOR-V 2500 1 1 1 2 2 3 4 121,0 121,0 121,0 152,4 152,4 121,0 219,1 128 128 128 156 156 128 224 341 412 412 535 645 472 553 319 390 390 514 624 450 / 14 14 14 17 23 23 23 88 88 88 108 114 73 117 145 220 220 330 430 288 290 73 73 73 79 79 64 132 10 10 10 15 15 10 15 40 40 40 70 70 40 150 M10 M10 M10 M12 M12 M10 3 x 10.2 x 15 / / / / / / 200 1 2 L4 L4 Ø2 Ø2 E3 E3 W1 W1 R1 R1 E4 E4 W2 W2 L1 L2 L3 L3 E1 L1 L2 E1 Ø1 E2 Ø1 R2 9,5 E2 43 R2 9,5 Ø3 140 Patte deSupport fixation 160 140 x 40 feetx160 CY 37100200 en option 160 Ø2 Patte de fixation 160 x 140 CY 37100200 (option) CY 37100200 en option 160 4 E3 L4 Ø2 W2 R1 E3 3/8 NPTF W1 E4 E4 W1 R1 L3 L2 Support feet 160 x 40 140 CY 37100200 (option) L4 3 L1 39 Ø3 L3 E1 L1 W2 E1 Ø1 Ø1 Ø3 E2 R2 E2 Ø4 9,5 43 Ø3 140 160 R2 Patte deSupport fixation 160 140x 40 feetx160 CY 37100200 en option CY 37100200 (option) Schema cotat Refrigeration & Climate Components Solutions 34.10 Water cooled condensers with liquid receiver C CONDOR-V n CONDOR-V 100 CONDOR-V 150 CONDOR-V 240 CONDOR-V 500 CONDOR-V 1000 CONDOR-V 1400 CONDOR-V 2500 n (vertical) Technical features CARLY references (1) CTCY-EN – 34.1-2 / 02-2014 Maximal working pressure Heat exchanger maximal working pressure Maximal working temperature Minimal working temperature Working temperature V PS PS Ech. TS maxi TS mini TS BT L bar bar °C °C °C 2,6 3,4 3,2 7,4 8,9 3,2 15,1 46 46 46 46 46 46 45 10 10 10 10 10 10 10 120 120 120 120 120 120 120 -20 -20 -20 -20 -20 -20 -20 / / / / / / / Volume CE Category (1) I I I II II I II Classification by volume, according to PED 97/23/EC (refer to chapter 0). Example of selection of a CONDOR water cooled condenser with liquid receiver The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature pressure refrigerant oil external environment). The values of the selection tables proposed in the CARLY catalogue match accurate test conditions. • Installation operating with R404A under the following conditions(1): ➜ Qkx = 10 kW ➜ Tk = 40 °C ➜ Tl1 = 20 °C ––––> Δt1 = 40 - 20 = 20K ➜ Maximum water flow = 500 l/h ➜ Normal city water • Which water cooled condenser CONDOR to choose? 1° Make corrections according to the water and the refrigerantes: - 1-1 Correction according to fouling factor Fe (refer to page 34.11) - 1-2 Correction according to refrigerant Fr (refer to page 34.11) Result: Qk = Qkx x Fe x Fr =10 kW 2° Report the capacity to the quick selection table, page 34.11, and take note of possible condensers. Result: CONDOR-V 500, CONDOR-V 1000, CONDOR-V 1400, CONDOR-V 2500 3° Search on the condenser feature curves, pages 34-6 to 34-9, the most suitable condenser. Result: - CONDOR V-500 works with Δt1 of 25K (page 34-13) (does not match because Δt1 > 20K). - CONDOR V-1000 matches perfectly (page 34-14). - CONDOR V-1400 works with a water flow of 700 l/h (page 34-14) (does not match because water flow > 500 l/h) - CONDOR V-2500 is too powerful because Δt1 < 20K (page 34-15). 4° Select the CONDOR V-1000 model and determine on the curves the water Δt and the water pressure drop (page 34-14). Result: (1) Δt water = 16,5K Δp water = 0,25 bar Chapter «Abbreviations and units» (refer to chapter 113). Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-V n 34.11 CTCY-EN – 34.1-2 / 02-2014 (vertical) Technical features • According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the fouling factor by the formula: Qk = Qkx x Fe Water type Normal city water Treated tower water Untreated tower water River water Glycol water below 40 % Glycol water below 70 % Fouling factor m2.K / W Correction factor Fe 43.10-6 43.10-6 86.10-6 86.10-6 86.10-6 172.10-6 1,00 1,00 1,19 1,19 1,19 1,56 • According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the following Fr factor by the formula: Qk = Qkx x Fr Correction factor Fr Refrigerant R404A / R507 R 22 / R410A / R407F R134a / R407C Quick Selection Table 20 15 Capacity kW n 1,00 0,92 0,85 10 5 0 0 200 400 Water flow l/h 600 800 1 000 Refrigeration & Climate Components Solutions 34.12 Water cooled condensers with liquid receiver C CONDOR-V (vertical) Technical features 3 CONDOR-V 100 Dt eau = 5K Dt eau = 3K 0,14 2,5 0,12 0,1 Puissance (kW) Capacity kW Dt1 = 20K 0,08 1,5 Dt1 = 15K 0,06 1 Dt eau = 1K Perte de cherge eau (bar) Dp eau 2 Water pressure drop bar Dt1 = 25K 0,04 Dt1 = 10K 0,5 0,02 0 0 100 200 300 400 500 600 700 800 Débit eau (l.h-1) Water flow l/h 4 CONDOR-V 150 Dt eau = 10K 0,16 Dt eau = 5K 3,5 0,14 Dp eau Dt1 = 25K 0,12 Puissance (kW) 2,5 Dt1 = 20K 2 Dt1 = 15K Dt1 = 10K 1,5 Dt1 = 5K 1 0,1 0,08 0,06 0,04 Dt eau = 1K 0,5 0,02 0 0 100 200 300 400 500 Débit eau Water flow(l.h-1) l/h 600 700 800 Perte de charge eau (bar) Dt eau = 3K Water pressure drop bar 3 Capacity kW n CTCY-EN – 34.1-2 / 02-2014 Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-V CTCY-EN – 34.1-2 / 02-2014 (vertical) Technical features 6 CONDOR-V 240 0,18 Dt eau = 15K Dt eau = 10K Dp eau 0,16 5 0,12 Puissance (kW) Capacity kW Dt1 = 25K Dt1 = 20K 3 Dt eau = 3K Dt1 = 15K 2 0,1 0,08 0,06 Perte de charge eau (bar) Dt eau = 5K 4 Water pressure drop bar 0,14 Dt1 = 10K 0,04 Dt eau = 1K 1 Dt1 = 5K 0 0,02 0 100 200 300 400 500 600 700 800 Débit eau (l.h-1) Water flow l/h 12 CONDOR-V 500 0,4 Dt eau = 15K Dt1 = 25K 0,35 10 Dt1 = 20K 0,25 Dt1 = 15K 6 0,2 Dt1 = 10K Dt eau = 5K 4 0,15 0,1 2 Dt1 = 5K 0 0,05 0 100 200 300 400 500 Débit eau (l.h-1) Water flow l/h 600 700 800 Perte de charge eau (bar) 8 Water pressure drop bar 0,3 Dt eau = 10K Capacity kW Puissance (kW) n 34.13 Refrigeration & Climate Components Solutions 34.14 Water cooled condensers with liquid receiver C CONDOR-V (vertical) Technical features 24 CONDOR-V 1000 0,6 Dp eau 22 18 Dt eau = 20K 16 Dt1 = 25K 14 Dt1 = 20K Dt eau = 15K 12 0,4 0,3 Dt1 = 15K 10 Dt eau = 10K 0,2 8 6 Water pressure drop bar 0,5 Perte de charge eau (bar) Puissance (kW) Capacity kW 20 Dt1 = 10K 4 Dt eau = 5K 0,1 2 0 0 100 200 300 400 500 600 700 800 Débit eau (l.h-1) Water flow l/h 18 CONDOR-V 1400 0,6 Dt eau = 20K Dp eau 0,5 Dt eau = 15K 12 0,4 Dt1 = 20K Puissance (kW) 10 Dt eau = 10K 8 0,3 Dt1 = 15K Dt1 = 10K 6 4 Dt eau = 5K 0,2 0,1 Dt1 = 5K 2 0 0 100 200 300 400 500 Débit eau (l.h-1) Water flow l/h 600 700 800 Water pressure drop bar Dt1 = 25K 14 Perte de charge eau (bar) 16 Capacity kW n CTCY-EN – 34.1-2 / 02-2014 Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-V CTCY-EN – 34.1-2 / 02-2014 (vertical) Technical features 30 CONDOR-V 2500 0,5 Dt eau = 20K 28 Dt eau = 15K 0,45 26 Dt1 = 25K Dp eau 24 0,4 Dt1 = 20K 0,3 18 Dt eau = 10K 16 Dt1 = 15K 14 0,25 0,2 12 Dt1 = 10K 10 0,15 8 Dt eau = 5K 0,1 6 4 Dt1 = 5K 0,05 2 0 0 600 800 1000 1200 1400 Débit eau (l.h-1) Water flow l/h 1600 Perte de charge eau (bar) 0,35 20 Water pressure drop bar 22 Capacity kW Puissance (kW) n 34.15 Refrigeration & Climate Components Solutions 34.16 Water cooled condensers with liquid receiver C CONDOR-V n CTCY-EN – 34.1-2 / 02-2014 (vertical) Spare parts and options 2 1 3 4 CONDOR V (1) CARLY references 100 - 150 - 240 - 500(S) CY 15580100 1000(E)-1400(E)-2500(S) CY 15580120 500(E)-1000 (S)-1400(S) CY 15580140 (1) A B Gasket for ROTALOCK connections and valves inch 1 1 1 1/4, 3/8 5/8, 7/8, 1 1/8 1/2 (E) = Inlet, (S) = Outlet CONDOR V (1) 100 - 150 - 240 - 500(S) 100 - 150 - 240 - 500(S) 500(E)-1000(S)-1400(S) 1000(E)-1400(E)-2500(S) 1000(E)-1400(E)-2500(S) 1000(E)-1400(E)-2500(S) (1) Part N° CARLY references CY 17400000 CY 17400010 CY 17400020 CY 17400035 CY 17400040 CY 17400050 (E) = Inlet, (S) = Outlet ROTALOCK connections, gasket included Part N° ØA outlet ODF connection ØB fixing UNF connector 2 2 2 2 2 2 inch inch 1/4 3/8 1/2 5/8 7/8 1 1/8 3/4 3/4 1 1 1/4 1 1/4 1 1/4 Refrigeration & Climate Components Solutions Water cooled condensers with liquid receiver C CONDOR-V n CTCY-EN – 34.1-2 / 02-2014 (vertical) Spare parts and options CONDOR V (1) 100 - 150 - 240 - 500(S) 100 - 150 - 240 - 500(S) 500(E)-1000(S)-1400(S) 500(E)-1000(S)-1400(S) 1000(E)-1400(E)-2500(S) 1000(E)-1400(E)-2500(S) 1000(E)-1400(E)-2500(S) A B (1) A Part N° CY 19700080 CY 19700110 CY 19700120 CY 19700130 CY 19700135 CY 19700160 CY 19700170 3 3 3 3 3 3 3 CARLY references 100 - 150 - 240 - 500(S) CY 19700090 100 - 150 - 240 - 500(S) CY 19700100 500(E)-1000(S)-1400(S) CY 19700140 B (1) ROTALOCK valve with connection to solder, gasket included CARLY references ØA outlet ODF valve ØB fixing UNF valve 1/4 3/8 1/2 5/8 5/8 7/8 1 1/8 3/4 3/4 1 1 1 1/4 1 1/4 1 1/4 inch inch (E) = Inlet, (S) = Outlet CONDOR V (1) n 34.17 ROTALOCK valve with connection to screw, gasket included Part N° ØB fixing SAE valve ØB fixing UNF valve 1/4 3/8 1/2 3/4 3/4 1 inch 3 3 3 inch (E) = Inlet, (S) = Outlet CONDOR V CARLY references Part N° Description 100 - 150 - 240 - 500 1000 - 1400 CY 37100200 4 Support feet Weights and packaging Unit weight kg CARLY references With Without Pièces détachées CONDOR-V : CY 37100200 packaging packaging CONDOR-V 100 CONDOR-V 150 CONDOR-V 240 CONDOR-V 500 4,50 5,65 5,65 11,10 Unit weight Packaging 4,20 5,20 5,20 10,80 number of pieces 1 1 1 1 CARLY references CONDOR-V 1000 CONDOR-V 1400 CONDOR-V 2500 kg Packaging With packaging Without packaging number of pieces 14,30 7,65 26,10 14,00 7,20 25,50 1 1 1
© Copyright 2024 ExpyDoc