TENDER FOR SUPPLY AND INSTALLATION OF SUCTION APPARATUS AC/DC & MANUAL, BAINS CIRCUIT (PEDIATRIC), MULTICHANNEL MONITOR AND MONITOR PULSE OXIMETER WITH PLETHYSOMOGRAPHY EQUIPMENT TO TNEMRI TENDER NO. 5407/TNMSC/ENGG/2014, dt.10.06.2014 RESULTS OF EVALUATION AND FINALLY SHORTLISTED BIDDERS. SUCTION APPARATUS AC/DC & MANUAL Sl. No Bidders Quoted 1. M/s. Model/ Make Vive Eterno – II Solutions Responsive bidders Reason for rejection Technical evaluation report Responsive Commercia l evaluation report Responsive Non Responsive Non Responsive ------- AC/DC Pedal Supreme make 2. M/s. SISCO Latex EUROVAC AC/DC As per technical evaluation report: 1. Weight is more than 5 Kgs. Private 2. AC& DC indication not available. Limited 3. Battery backup is only 1.30 against the tender requirement of 4 hrs. 4. Wall mountable option not available. As per commercial evaluation report: The bidder did not furnish any certificate such as end user certificate. Annual turnover statement and cash credit limit, despite given chance . MULTICHANNEL MONITOR Sl. No Bidders Quoted Model/Make 1. M/s. Trans G3G, General Health Care Meditech India Pvt. Ltd., Inc., P.R.China Responsive bidders Commercial Technical evaluation evaluation report report Responsive Responsive Reason for rejection -------- Sl. No Bidders Quoted 2. M/s. Model/Make M M Vismo Medical 2703, Systems Kohden Responsive bidders Commercial Technical evaluation evaluation report report PVM NonNikon responsive Responsive Reason for rejection As per the demo report, the model quoted is not meeting the following points: 1. Battery backup is only for 3 hrs against the tender requirement of 4 hrs. 2. Spo2 range is only 50 to 100% instead on 0 to 100%. 3. Power consumption is 100 watt against the tender requirement of less than 50 watts. 4. The model is not simple to use, operate and maintain. 3. M/s. Indian PM1200JET, Medical Systems Riransa Nonresponsive Nonresponsive & Not demonstrated and as per the commercial evaluation report, the bidder did not furnish end user certificate for their manufacturer Technologies despite given chance. 4. Sign NonBPL responsive As per the demo report, the model M/s. Smart Solokrafts S10, Industries Medical points: Technologies 1. I/O Communication – COMI – Responsive quoted is not meeting the following RS 232 is not available. Pvt. Ltd. 2. System is not able to upgrade to EtCo2 & printer in future. 3. The equipment can operate only in 0 to 40 deg C and humidity of 90% against the tender requirement of 10 to 45 deg C and humidity of 100%. Sl. No Bidders Quoted Model/Make Responsive bidders Commercial Technical evaluation evaluation report report Reason for rejection 4. The equipment is sensitive to fluctuation. 5. M/s Schiller Truscope II. Healthcare BioLight Nonresponsive Responsive As per the demo report, the model quoted is having weight of 5.610 kgs against the tender requirement India Pvt. Ltd., of weight of less than 4.5 Kgs. 6. M/s. Vin YK-8000C, Xuzhou Biotech Yongkang Systems Ltd., Electronic Science Technologies Co. Ltd. Responsive Responsive -------- MONITOR PULSE OXIMETER WITH PLETHYSOMOGRAPHY Sl. No 1. Bidders Quoted M/s. Health Trans G1B+, General M/s. Responsive bidders Commercial Technical evaluation evaluation report report Responsive Responsive Reason for rejection -------- Care Meditech Inc., India Pvt. Ltd., 2. Model/Make P.R.China Indian Masimo SAT Responsive Responsive OXM NonM/s Schiller Argus responsive Healthcare India Plus, BioLight Pvt. Ltd., Responsive -------- Medical Systems 901+, Masimo & Technologies 3. As per the wrapping available. Hence not by the specialists. Bains Circuit (Pediatric) – No response report, protective recommended demo is not
© Copyright 2024 ExpyDoc