MoPyC Modular Pyrocarbon Radial-Head Prosthesis Try a new head ! Pyrocarbon head for optimum contact Modularity: 48 combinations Elbow Anatomic implant 15° angulation neck Well-contained expansion stem Cementless fixation www.bio-profile.com w w w.t orni er. com MoPyC Indications • Un-reconstructive comminuted fracture of the radial head associated with elbow instability • Failure of radial head arthroplasty • Humero-radial and superior radio-ulnar arthritis Instrumentation I-PTR-SET F-PTR-H18 F-PTR-H20 F-PTR-H22 F-PTR-N5 F-PTR-N6,5 F-PTR-N8 F-PTR-N10 F-PTR-S7 F-PTR-S8 F-PTR-S9 F-PTR-S10 I-PTR-GC1 I-PTR-GC1/2 Instrumentation Set MoPyC Trial Head MoPyC Small Trial Head MoPyC Medium Trial Head MoPyC Large Trial Neck MoPyC Small Trial Neck MoPyC Medium Trial Neck MoPyC Large Trial Neck MoPyC X-Large Trial Stem MoPyC Small Trial Stem MoPyC Medium Trial Stem MoPyC Large Trial Stem MoPyC X-Large Cutting Guide Orientation Plate I-PTR-LG1 I-PTR-R5 I-PTR-R7 I-PTR-R8 I-PTR-R9 I-PTR-R10 I-PTR-SI1 I-PTR-SD1 I-PTR-HD1 I-PTR-OT1 I-PTR-HI1 I-PTR-HE1 I-PTR-HX1 I-PTR-CS1 Length Gauge Rasp Broach R7 Broach R8 Broach R9 Broach R10 Stem Holder Screw Driver Stem Impacting/Extracting Device Orientation Tip Head Assembling Device Head Extracting Device Neck Holder Sizer Box Implants references HEAD Implant size Small Medium Large Diameter (mm) 18 20 22 Height (mm) 9 10 11 Reference PTR-H18 PTR-H20 PTR-H22 Trial implant Implant size Small Medium Large X-Large Angulation 15° 15° 15° 15° Length (mm) 5 6,5 8 10 Reference PTR-N5 PTR-N6,5 PTR-N8 PTR-N10 Trial implant Implant size Small Medium Large X-Large Diameter (mm) 7 8 9 10 Length (mm) 40 44 48 50 Reference PTR-S7 PTR-S8 PTR-S9 PTR-S10 Trial implant Implant size Small Large Diameter (mm) Length (mm) Compatible with PTR-S7 and PTR-S8 Compatible with PTR-S9 and PTR-S10 Reference PTR-CS PTR-CL SCREW* NECK STEM * screws are assembled with corresponding stems and delivered sterile. Bibliography «Résultats préliminaires d’une prothèse de tête radiale à cupule pyrocarbonée” M. WINTER, J.P. PEQUIGNOT, Y. ALLIEU, F. DE PERETTI Chirurgie de la main 24 - 2005.- 312-390 - (GEM 2005). «Surgical management of elbow dislocation associated with non-reparable fractures of the radial head» M. Winter a,*,b, C. Chuinard c, A. Cikes b, C. Pelegri b, N. Bronsard b, F. de Peretti b Chirurgie de la main 28 (2009) 158–167 Distributed by Manufacturer Tornier SAS Etablissement Bioprofile Parc d’activités Polytec 20 rue des Berges 38024 GRENOBLE cedex 1 France 0459 Tornier SAS Etablissement Bioprofile Parc d’Activité Polytec 20, rue des Berges 38024 Grenoble cedex 1 - France Tel.: +33 (0) 4 76 23 94 60 Fax: +33 (0) 4 76 23 94 61 BIOP/PTR/MKT/0065 - Ind C - Non contractual document «Radial head replacement with a pyrocarbon head prosthesis: preliminary results of a multicentric prospective study» Y. ALLIEU, M. WINTER, J.P. PEQUIGNOT, PH. DE MOURGUES “European Journal of Orthopaedic Surgery & Traumatology” 2006 – 16: 1-9.
© Copyright 2024 ExpyDoc