Additional operating instructions according to ATEX 94/9/EC BSK-RPR Fire Damper Contents Additional operating instructions according to ATEX 94/9/EC .................................................. 1 GENERAL CONDITIONS ........................................... 1 DESCRIPTION .......................................................... 3 EC Certificate of Conformity 0761 – CPD – 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01 MODELS AND DIMENSIONS .................................... 4 SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 7463-980-0 Fax +49 (0) 7463-980-200 www.SCHAKO.de | [email protected] Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC GENERAL CONDITIONS GENERAL CONDITIONS GENERAL DESCRIPTION AND INSTRUCTIONS DELIVERY AND STORAGE Upon receipt, the devices must be checked for completeness and transport damage. If the device was delivered incompletely or damaged, the forwarding company and the SCHAKO KG have to be informed immediately. These additional operating instructions must be observed prior to mounting and commissioning the device. These additional operating instructions contain basic information regarding its use in areas subject to explosion hazards to be observed during assembly, operation and maintenance. Prior to mounting and commissioning and during maintenance work, the present additional operating instructions must be read by the installer and the responsible skilled personnel/system operator! PERSONNEL QUALIFICATION AND TRAINING The personnel for assembly, inspection and maintenance must have the relevant qualification for this work. The area of responsibility, competence and monitoring of the personnel must be exactly regulated by the system operator. If the personnel does not have the required knowledge, it must be trained and instructed. Moreover, the system operator must ensure that the contents of the additional operating instructions are completely understood and adhered to by the personnel. SAFETY-CONSCIOUS WORK The safety instructions given in these additional operating instructions, the existing national and international regulations on explosion protection, accident prevention and the system operator's internal work, operating and safety regulations must be observed. The fire dampers must not be exposed directly to weather, solar radiation and moisture ( see also "General information"). MOUNTING INFORMATION Mounting, electrical connection work and commissioning must be carried out by skilled personnel only and in accordance with the recognised technical rules and the safety and accident prevention regulations. MAINTENANCE Only a device subjected to proper maintenance and kept in perfect condition can guarantee safe and reliable operation. When defective parts are replaced with spare parts, only SCHAKO KG original spare parts may be used. The SCHAKO KG cannot be held liable for any damage caused by using spare parts that are not original and will not give any warranty. HAZARD CAUSED BY NON-OBSERVANCE OF THE SAFETY INSTRUCTIONS Non-observance of the safety instructions can result both in putting persons and the environment and operating units at risk. Likewise, non-observance of the safety instructions will result in the loss of any claims for damages. DESIGNATED USE The devices have been designed for use in ventilation systems in areas subject to explosion hazards according to the ATEX marking "Device group II, Zones 1, 2 and 21, 22. These devices are not suitable for use in unreleased Ex zones. The operating safety of the delivered devices is only guaranteed when used in accordance with their designated use. Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 2 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC DESCRIPTION DESCRIPTION Fire dampers built into ventilation ducts (air-conditioning systems) are used for the automatic locking of fire lobbies. The fire damper BSK-RPR corresponds to EN 15650, EN 13501-3 and EN 1366-2. The fire damper BSK-RPR has been tested according to EN 1366-2 in accordance with the Declaration of Performance No. 09-22-DoP-BSK-RPR-2013-07-01. It is in possession of the EC Certificate of Conformity 0761 CPD - 0245. Its classification according to EN 13501-3 is EI 90 (ve, ho i↔o) S. According to Directive 94/9/EC, EC Certificate of Conformity Number EPS 09 ATEX 2 153 X, its use in areas subject to explosion hazards is permitted, not only with spring return actuator ATEX-ELD-BLF-K2, including safety temperature limiter (FireSafe/ExPro-TT), but also with mechanical trigger via fusible link (manual actuation with or without ATEX limit switch ES-Ex). The fire damper is marked as follows according to ATEX: II 2 G IIC T6 II 2 D T80°C *) II 3 D T80°C *) The fire damper complies with the regulations of the ATEX directives and may be used in supply and return air installations of ventilation systems in areas subject to explosion hazards. The fire damper is certified for device group II, Zones 1, 2 and 21, 22. Zones 1 and 2 represent the application range containing gases/vapours, while Zones 21 and 22 represent the application range containing dusts. Classification by zone must be established by the system operator or planner in compliance with current standards. Note: In explosion-protected zones, only devices that have an ATEX approval for this use may be used. EPS 09 ATEX 2 153 X when using a Schischek FireSafe safety temperature limiter. The national standards and guidelines must be observed in connection with these additional operating instructions. For maintenance, servicing, retrofitting, etc., it may be necessary to provide on-site inspection openings in suspended ceilings, shaft walls, downstream ventilation ducts, etc. They must be built in in sufficient numbers and size and must not impair the functioning of the fire dampers. QUALITY ASSURANCE Production takes place by certified QM processes according to EN ISO 9001. Moreover, an in-factory production control (WPK) and continuous monitoring of the latter by an accredited body take place. The fire dampers must be connected to the ventilation ducts of the ventilation system either on one or both sides. When connected on one side, finishing protective gratings made of non-flammable building materials (EN13501-1) must be provided on the opposite side. The fire dampers can be connected to non-flammable or to flammable ventilation ducts. Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 3 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS MODELS AND DIMENSIONS Dimensions BSK-RPR-S (plug-in connection) Figure 1: Dimensions of the BSK-RPR-S Figure 2: Dimensions of the BSK-RPR-S (with ATEX-ELD-K2) 1 Housing 2 Damper leaf 3 Hand lever 4 Locking profile 5 Trigger device 6 Fusible link 7 Mounting frame AR 8 Drive unit 9 Earthing connection 10 ATEX-ELD-K2 11 Safety temperature limiter Rubber lip seal for BSK-RPR-S Model BSK-RPR-S is delivered as standard with rubber lip seal Figure 3 : Rubber lip seal Construction subject to change No return possible! Available sizes [mm] L [mm] Nominal øD size [mm] BSK-RPR-S BSK-RPR-F 100 98 125 123 140 138 160 158 180 178 455 375 200 198 224 222 250 248 280 278 580 500 315 313 (standard) (standard) 355 353 400 398 450 448 500 498 Table 1: Available sizes [mm] Version: 2014-07-01 | Document: Z09/46 | Page 4 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS BSK-RPR-S with mounting frame AR Figure 4: Dimensions of the BSK-RPR-S with mounting frame AR Figure 5: Dimensions of the BSK-RPR-S with mounting frame AR (with ATEX-ELD-K2) BSK-RPR-F (flanged connection) Figure 6: Dimensions of the BSK-RPR-F Figure 7: Dimensions of the BSK-RPR-F (with ATEX-ELD-K2) Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 5 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Weight table [kg] BSK-RPR-S L=455 Nominal size øD [mm] 100 125 140 160 180 200 224 250 280 315 355 400 450 98 123 138 158 178 198 222 248 278 313 353 398 448 Manual release 2.44 (6.73)¹⁾ 2.83 (7.69)¹⁾ 3.06 (8.27)¹⁾ 3.35 (9.02)¹⁾ 3.65 (9.79)¹⁾ 3.97 (10.59)¹⁾ 4.37 (11.58)¹⁾ 4.8 (12.62)¹⁾ 6.31 (16.55)¹⁾ 7.14 (18.40)¹⁾ 8.08 (20.53)¹⁾ 9.09 (22.89)¹⁾ 10.5 (25.84)¹⁾ 500 498 11.85 (28.75)¹⁾ L=580 Spring return actuator 3.89 (8.18)¹⁾ 4.28 (9.14)¹⁾ 4.51 (9.72)¹⁾ 4.8 (10.47)¹⁾ 5.1 (11.24)¹⁾ 5.42 (12.04)¹⁾ 5.82 (13.03)¹⁾ 6.25 (14.07)¹⁾ 7.79 (18.03)¹⁾ 8.62 (19.88)¹⁾ 9.56 (22.01)¹⁾ 10.57 (24.37)¹⁾ 11.98 (27.32)¹⁾ 13.33 (30.23)¹⁾ Manual release Spring return actuator 2.74 (7.03)¹⁾ 4.19 (8.48)¹⁾ 3.21 (8.07)¹⁾ 4.66 (9.52)¹⁾ 3.49 (8.70)¹⁾ 4.94 (10.15)¹⁾ 3.84 (9.51)¹⁾ 5.29 (10.96)¹⁾ 4.2 (10.34)¹⁾ 5.65 (11.79)¹⁾ 4.59 (11.21)¹⁾ 6.04 (12.66)¹⁾ 5.07 (12.28)¹⁾ 6.52 (13.73)¹⁾ 5.58 (13.40)¹⁾ 7.03 (14.85)¹⁾ 7.17 (17.41)¹⁾ 8.65 (18.89)¹⁾ 8.13 (19.39)¹⁾ 9.61 (20.87)¹⁾ 9.19 (21.64)¹⁾ 10.67 (23.12)¹⁾ 10.34 (24.14)¹⁾ 11.82 (25.62)¹⁾ 11.91 (27.25)¹⁾ 13.39 (28.73)¹⁾ 13.42 (30.32)¹⁾ 14.9 (31.80)¹⁾ ¹) approx. weight with additional mounting frame AR BSK-RPR-F L=375 L=500 Nominal size øD [mm] Manual release Spring return actuator 100 125 140 160 180 200 224 250 280 315 355 400 450 98 123 138 158 178 198 222 248 278 313 353 398 448 2.49 2.89 3.13 3.43 3.74 4.07 4.48 4.93 6.45 7.30 8.26 9.29 10.73 3.94 4.34 4.58 4.88 5.19 5.52 5.93 6.38 7.93 8.78 9.74 10.77 12.21 2.80 3.29 3.57 3.93 4.31 4.70 5.19 5.71 7.33 8.29 9.37 10.55 12.14 4.25 4.74 5.02 5.38 5.76 6.15 6.64 7.16 8.81 9.77 10.85 12.03 13.62 500 498 12.10 13.58 13.67 15.15 Manual release Spring return actuator Table 2: Weight tables [kg] Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 6 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Electric spring return actuator type ATEX-ELD-K2 ATEX-ELD-K2 (Ex Max-15-BF) Connection ExMax-5.10-BF and ExMax-15-BF Open/closed 1-wire spring return + Ex-i circuit BSK 24…240 VAC/DC integrated, permanently set auxiliary switch, max. 24V/3A, 240V/0.5A switching at an angle of rotation 5° and 85°. The voltage on the auxiliary switch must be identical to the supply voltage and protected by an identical fuse. SB 7.0 Ex-i circuit for passive, potential-free pushbuttons provided by the customer and thermally activated safety release device (Type FireSafe / ExPro-TT) ! Attention! For a 1-wire control, the heating is not active when the contact is interrupted Button Heating Standard connection = spring return in ~ 10 sec. Figure 8: Circuit diagram ATEX-ELD-K2 Electric explosion-protected spring return actuators with safety temperature limiter (FireSafe/ ExPro-TT). Technical data ATEX-ELD-K2 Power supply 24…240 V AC/DC, ± 10% each, self adaptable 50...60 Hz ± 20% Trigger temperatures 72° optionally 95 °C (for hotair heating). Operating position (damper "OPEN") and tensioning of the return spring by applying the supply voltage (universal power supply 24 - 240 VAC/DC) Safety position (damper "CLOSED") through spring energy when supply voltage is interrupted or the thermal fuses Tf1 (ambient temperature) or Tf2/Tf3 (duct inside temperature) respond. A response of the thermal fuses Tf1, Tf2 (or Tf3) will interrupt the sensor circuit permanently and irrevocably. End position signalling by integrated auxiliary switches, switching at an angle of rotation of 5° and 85°. Frequency Protection class I (earthed) On-site function control is possible by means of the control key of of the safety temperature limiter Protection type according to DIN 60 529 Tested according to EMC Safety tested IP 66 Ambient temperature (operation) Ambient humidity -40 ... +40 °C Attention! Safety function is only guaranteed if the drive has been connected to the supply voltage in accordance with regulations and unlocked mechanically. Power consumption Holding max. 20 W Heating capacity approx. 16 W Current on making approx. 2.0 A at 24 V for approx. 1 sec. Running time Motor 30s Spring return 10s Auxiliary switch 2 integrated, permanently set, potential-free auxiliary switches with changeover contact Switching voltage 24 V DC / 230 V AC Switch voltage 0.5 mA - 3 A Switching points Angles of rotation: 5° / 85° 2004/108/EC 2006/95/EC ≤ 95%, non-condensing Table 3: Technical data ATEX-ELD-K2 Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 7 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Limit switch type ES-Ex General information Limit switch for application in areas subject to explosion hazards II 2G Ex d IIC T6/T5 Gb, II 2D Ex tb IIIC T 80°C/ 95°C Db IP65; 250V / 6A AC15; 230V / 0.25A DC13; -20°C ≤ Ta ≤ +65°C Figure 9: Circuit diagram limit switch type ES-Ex Construction subject to change No return possible! During mounting or installation, there is a risk of injuries. To avoid any possible injuries, personal protective equipment (PPE) must be worn. Fire dampers must be installed such that external forces do not impair their permanent functioning. During mounting it may be required to provide reinforcements for the housing or the like. The requirement of statically load-bearing lintels may have to be taken into consideration. Improper transport/handling may result in damage/functional impairment. In addition to that, the film of the transport packaging must be removed and the delivery inspected for completeness. In storage, fire dampers must be protected from dust, dirt, moisture and the effects of temperature (e.g. direct sunlight, heat-emitting light source, etc.). They must not be exposed to direct effects of the weather and must not be stored below -40 °C (ES-Ex -20°C) or above 50 °C. The fire damper must be protected from dirt and damage. After installation is complete, any dirt must be removed immediately. Enough space must be provided for installation, mortar lining, etc. Carry out a functional check of the fire damper before and after mounting and ensure ready access. Electrical installations or work on electrical components may only be carried out by skilled electricians. The supply voltage must be switched off when performing this work. Version: 2014-07-01 | Document: Z09/46 | Page 8 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Information regarding assembly and commissioning Prior to being installed in the ventilation system, the fire damper must be checked for damage. Damaged fire dampers must not be installed. Use only approved fastening material for mounting. The following inspection criteria must be observed: Visual inspection of the device Check the fastening of the device Check the electrical connections Check the grounding connection for tight fit and good contact. Functional check For additional inspections, please refer to the technical documentation or additional maintenance instructions. No additional parts may be fastened to the fire damper. Use and electrical connection of actuators in areas subject to explosion hazards The fire damper must be connected to the ventilation duct network on both sides in electrically conducting fashion. Only ATEX-approved electrical equipment according to ATEX Directive 94/9/EC for Zones 1, 2, 21, 22, such as actuators, terminal boxes and thermocouples as specified by SCHAKO KG may be used for devices from SCHAKO KG. The device may only be used in accordance with its designated use in air ventilation systems for supply air and return air. In order to avoid the risk of static charges, the fire damper must be connected to the on-site equipotential bonding on the grounding connection provided for this purpose. Make sure that the ventilaton systems are not subjected to any anomalous operating conditions, such as vibrations, pressure surges or high proportions of solids in the medium. Information regarding maintenance and inspection Proper maintenance increases operational safety and the service life of the device. This is why the devices should be subjected to regular inspection. If inspection dates are prescribed by law, they must be complied with. The operating personnel must be informed, prior to starting maintenance and inspection work. The personal safety measures must be looked up in the safety data sheet. Hazard caused by contact or inhaling hazardous substances must be excluded by taking appropriate safety measures. The connection lines must be installed for permanent use and in such a way that they are sufficiently protected from mechanical and thermal damage. Devices with explosion-protected drives and terminal boxes have to be attached over the external potential connecting terminal to the potential equalisation provided by the customer with at least 4 mm² cooper solid-core. The electrical connection lines of the actuators must be connected in a terminal box according to ATEX Directive 94/9/EC for Zones 1, 2, 21, 22 if the electrical connection is made in the area subject to explosion hazards. The dimensioning of the conductor cross-sections must be observed. The actuators are maintenance-free with respect to their function, but the relevant maintenance regulations according to ATEX directives or factory regulations must be observed. Prior to maintenance or inspection, all system components up- and downstream of the device must be switched off and secured against being switched on again. Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 9 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Certificate of conformity Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 10 Fire Damper Model BSK-RPR Additional operating instructions according to ATEX 94/9/EC MODELS AND DIMENSIONS Construction subject to change No return possible! Version: 2014-07-01 | Document: Z09/46 | Page 11
© Copyright 2024 ExpyDoc