Technics Data Elfopack

RESIDENTIAL
CPAR-XIN
5
new
generation
Reversible heat pump
With active thermodynamic heat recovery and domestic hot water production
Air cooled
Indoor installation
Fresh air flow rate 100 m³/h
ELFOPack
ELFOPack is the multifunction heat pump unit for stand-alone systems
that simultaneously meets the needs of heating, cooling, dehumidification,
production of domestic hot water, controlled mechanical ventilation with
thermodynamic recovery and electronic filtering.
The main features are:
Optimal
comfort thanks to the system that quickly adapts to the load
conditions of the room and the thermal load
The
air is constantly filtered by electronic filters whose efficiency levels
exceed 99.9%
Controlled
mechanical ventilation with thermodynamic recovery in
winter and summer
Air
dehumidification in summer mode
Extremely
efficient production of domestic hot water in winter and
free of charge in summer
High
seasonal efficiency Free-cooling,
that is, cooling free of charge under special environmental
conditions
Extensive
use of renewable energy Elimination
of polluting emissions and CO2 in urban areas
Improvement
of the building’s energy rating thanks to a reduction in
the demand for primary energy
Lower
running costs
Extremely
low investment and quick installation, as all the functions are
concentrated in one piece of equipment
No
works required for the gas connection, chimney and relative measures to
ensure the system is in line with safety regulations
Simple
installation that does not need to be carried out by an expert
Aeraulic
ducts that can be integrated into industrial building solutions
PATENT
PENDING
functions and features
AIR
Heat pump
R-410A
Air cooled
Indoor installation
R-410A
Hermetic Rotary
Active
thermodynamic
recovery
Full Inverter DC
dimensions and clearances
ba
c d
e
C1
Size – CPAR-XIN
A - Length
B - Width
C - Height
A1
A2
B1
B2
C1
Operating weight
C
mm
mm
mm
mm
mm
mm
mm
mm
kg
5
812
460
2180
200
200
300
600
100
400
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to
the relative Technical Bulletin.
B1
B
B2
A
A2
A1
CAUTION!For trouble-free operation of the unit it is essential to maintain the safety
distances indicated by the green areas.
(a) Exhaust outdoors(b) Stale air extraction (bathrooms and kitchen)
(c) Supply into the room(d) Fresh air intake
(e) Indoor air recirculation intake
32
Size – CPAR-XIN
Heating
capacity
Thermodynamic SCOP
Cooling
capacity
Thermodynamic SEER
Maximum air flow rate in the room
Maximum air flow taken from the bathrooms and the kitchen
Maximum air flow of internal ambient recirculation
Maximum air flow air intake from outside
Maximum air flow of outside expelled air
Available head
Compressor type
DHW tank
DHW tank temperature
Safety electric heater
Standard power supply
(1)
(2)
(3)
(2)
(4)
5
3,18
3,83
2,14
2,95
400
100
300
400 of which 100 fresh air
400 of which 100 extraction air
120
ROT DC inverter
180
40/60
1,20
230/1/50
kW
kW
m³/h
m³/h
m³/h
m³/h
m³/h 400
Pa
l
°C
kW
V/f/Hz
Notes
(1) Overall heating capacity for transmissions + ventilation + domestic hot water production
(4 people - 50 litres/day per person). Conditions: outdoor air 7°C DB, 6.1°C WB, renewal and
recirculation stale air 20°C DB.
(2) SCOP / SEER average thermodynamic seasonal efficiency of a home in Milan with an
overall demand for transmissions, ventilation and domestic hot water (4 people - 50 litres/
day per person) equal to the overall heating capacity provided by ELFOPack as per project
specifications (-5°C). The average thermodynamic seasonal efficiency does not take into
account the energy absorbed by the fans, as it depends on the pressure drops of the aeraulic
distribution of each specific installation.
REF-DG14B001GB-00
technical data
(3)
(4)
Total cooling capacity for transmissions + ventilation. Production of domestic hot water (4
people - 50 litres/day per person) with total recovery. Conditions: outdoor air 35°C DB, renewal
and recirculation stale air 26°C DB.
ROT DC Inverter = DC Inverter rotary compressor
Data contained in this document are not binding and may be changed by the Manufacturer without notice.
www.clivet.com
33