0,023 Heat Insulation Insulating and Waterproofing Systems RF3 D = 0,023 W/mK Polyiso foam panel coated with multilayer Duotwin® permeable to vapour and tight to water. UNI EN 13165 UNI EN 13165 PRECISO RF3 D = 0,023 W/mK The Isolparma RF3 panel may be supplied with Preciso processing which involves cuts and/or incisions made to measure, to ensure perfect adherence to buildings, structural or architectural elements, etc. Recommended applications: zz Heat insulation of perimeter walls in cavities zz Heat insulation of floors and ceilings zz Heat insulation of ventilated and non-ventilated pitched roofs zz Heat insulation of industrial tiled roofs or sheds Warning: Isolparma RF3 boards are not suitable for roofing applications in combination with a propane torch. For such applications ISOPLAN PUR RF3 is recommended. MISTRAL PIR RF3 D = 0,023 W/mK Mistral is a pre-assembled insulated and ventilated roofing element that combines a base of rigid thermoset polyisocyanurate board, CFC and HCFC free, with Polytwin® facing on both sides and an OSB 3 board top, raised on polyurethane bearing pads, to create a bi-directional air chamber. Mistral is sutiable also for use in environments with high relative moisture. On request the OSB3 board can be replaced with plywood or other types of wood with various finishes and thicknesses. Recommended applications: zz Heat insulation of ventilated pitched roofs under flat or bent tiles. The OSB3 top is suitable to receive any type of waterproofing finish. UNI EN 13165 UNI EN 1398 2004 ISOPLAN PIR RF3 D = 0,023 W/mK Isoplan PIR is a pre-assembled roofing element consisting of a flat (or cut-in) rigid thermoset polyisocyanurate board, available with various facing materials (Duotwin®, embossed aluminium, glass) topped by a bituminous underlay membrane of choice. The bituminous underlay membranes can be aap- or sbs- modified, glass or polyester reinforced. The boards have a head and side selvedge that may vary from 5 to 10 cm. PRECISO ISOPLAN PIR RF3 D = 0,023 W/mK PRECISO ISOPLAN PUR RF3 is a heat-insulating and waterproofing system consisting of pre-marked panels of polyiso foam coated with Duotwin®, made to measure with the Preciso system, pre-bonded to a waterproofing membrane of choice. The membranes can be app- or sbs-modified, polyester or glass reinforced, of various thickness or weight and with a smooth or slate finish. The boards have a head and side selvedge that may vary from 5 to 10 cm. Recommended applications: zz Heat insulation and base sheet waterproofing for most types of civil and industrial flat or pitched roofs and sheds. zz Heat insulation and base sheet waterproofing of industrial tiled or shed roofs (*): The CE marking refers to the harmonised technical standards of each component. λD = 0,023 W/mK - THE ADVANTAGES The low heat conductivity value of Isolparma RF3 insulations, enables the design and construction of efficiently insulated building structures using thicknesses of insulating material that are significantly lower than those required using alternative materials. Reducing the volume of insulating material, with the same performance, involves: zz improving the ratio between built volume and living space zz reducing the economic costs caused by the transport and installation of the material zz reducing the environmental impact generated by the production and transport of the materials and subsequent disposal thereof at the end of their working life. Isolparma RF3 Rigid Foam boards made of polyiso foam faced with multilayer Duotwin® or Politwin® linings, also ensure: zz stability of the technical characteristics and performance over time zz rigidity and compactness zz safety in use and environmental compatibility zz resistance to the most common physical and chemical agents and to the working temperatures zz high quality standards and conformity with the European technical standard UNI EN 13165 Thicknesses of alternative materials necessary to match the performance of ISOLPARMA RF3 Rigid Foam board, 100 mm thick: U = 0,23 W/m2K W Mi λ = ood Ex ne λ D r Po 0,0 woo D= λ = trud Po 0,0 al w lys 42 l D e λ o 0 d l Po 38 ol W/ ,03 p D= λ = yst 0,0 tyren o mK W D y 6 λ = liys 0,0 ren /m 35 e W/ lyst D f K 31 e 0,0 o IS y m oa W r f K e /m m W/ oa 23 OL ne K mK m W/ PA wi mK RM t hg A RF rap 3 hit e Valori di Trasmittanza termica (U in W/m2K) e di Resistenza termica (R in m2K/W) in funzione dello spessore mm 30 40 50 60 70 80 90 100 110 120 U 0,80 0,60 0,48 0,40 0,34 0,30 0,27 0,24 0,22 0,20 R 1,30 1,74 2,17 2,61 3,04 3,48 3,91 4,35 4,78 5,22 RF3 other caracteristics Compression resistance (10% crushing - EN 826) Water absorption (total immersion 28 days - EN 12087) Resistance to vapour diffusion (EN 12086) Euroclass Fire Reaction (EN 13501-1) 130-150 kPa according to thickness < 1% in weight μ 148 ± 24 F SERIES RF3 standard measurements flat dimensions mm Thickness mm 1200 x 600 from 30 to 120 1200 x requested measurement 600 x requested measurement from 30 to 120 MISTRAL PIR RF3 1200 x 585 panel from 40 to 120 air chamber 40 OSB 12 ISOPLAN PIR RF3 1200 x 1200 from 30 to 120 1200 x requested measurement from 30 to 120 RF3 PRECISO RF3 PRECISO ISOPLAN PIR RF3 Isolparma Srl - Via Mezzavia 134 - 35020 Due Carrare (PD) Italy - ph +39 049 9126213 fax +39 049 9129616 www.isolparma.it
© Copyright 2024 ExpyDoc