MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE DEI VENTILCONVETTORI Carisma Fly FAN COIL Carisma Fly INSTALLATION, USE AND MAINTENANCE MANUAL MANUEL D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN DES VENTILO-CONVECTEURS Carisma Fly HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG DER GEBLÄSE-KONVEKTOREN Carisma Fly MANUAL DE INSTALACIÓN, USO Y MANTENIMIENTO DE LOS VENTILADORES CONVECTORES Carisma Fly HANDLEITUNG VOOR DE INSTALLATIE, HET GEBRUIK EN HET ONDERHOUD VAN DE VENTILATORS-CONVECTORS Carisma Fly Fly mod. C V P Ventil Carisma Via Piave, 53 s 20011 Corbetta (MI) s ITALY Tel. +39.02.97203.1 ric. autom. s Fax +39.02.9777282 - +39.02.9772820 E-mail: [email protected] s Internet: www.sabiana.it E 12/12 C 12/12 Cod. 4050849 INDICE INDEX TABLE DES MATIÈRES INHALT Scopo Identificazione macchina Trasporto Pesi e dimensioni unità imballata 2 Application 3 Identifying the appliance 4 Transport Weights 4 and dimension packed unit 2 3 4 Note generali alla consegna Avvertenze generali Regole fondamentali di sicurezza Prescrizioni di sicurezza Limiti di impiego Smaltimento Caratteristiche tecniche Scelta della posizione dell’unità Installazione meccanica Collegamento idraulico Collegamenti elettrici 5 General notes on delivery 5 General warnings 5 5 6 7 8 8 9 10 12 13 16 Comandi e schemi elettrici Legenda 17 18 Pulizia, manutenzione, ricambi Ricerca guasti Perdite di carico lato acqua Dichiarazione di conformità 37 38 39 40 SCOPO Fundamental safety rules Safety rules Operating limits Waste disposal Technical characteristics Selection of position of the unit Mechanical installation Hydraulic connections Electrical connections Electrical controls and wiring diagrams Legend Cleaning, maintenance and spare parts Troubleshooting Pressure drop table Declaration of conformity 4 6 7 8 8 9 10 11 12 15 17 18 37 38 39 40 APPLICATION 2 Zweckbestimmung 3 Kennzeichnung des Geräts 4 Transport Gewicht 4 und dimensionen verpacktes gerät Allgemeine 5 Hinweise zur Lieferung 5 Allgemeine Hinweise Grundsätzliche 6 Sicherheitsvorschriften 7 Sicherheitsvorschriften 8 Einsatzgrenzen 8 Entsorgung 9 Technische Merkmale 10 Positionierung der einheit 11 Mechanische Installation 12 Wasseranschluss 15 Elektroanschlüsse 6 7 8 8 9 10 11 12 15 17 Steuerungen und Schaltpläne 18 Legende 17 18 37 38 39 40 BUT Reinigung, Wartung, Ersatzteile Fehlersuche Wasserseitige Druckverluste Konformitätserklärung INHOUD 2 Doel 3 Identificatie apparaat 4 Trasporto Gewicht 4 en afmetingen verpakte eenheid Algemene Notas generales para la entrega 5 opmerkingen bij de levering Advertencias generales 5 Algemene voorschriften Belangrijke Normas fundamentales de seguridad 6 veiligheidsvoorschriften Prescripciones de seguridad 7 Veiligheids-voorschriften Límites de uso 8 Gebruikslimieten Eliminación 8 Afdanking Características técnicas 9 Technische karakteristieken Elección de la posición de la unidad 10 Positioneringseenheid Instalación mecánica 11 Mechanische installatie Conexión hidráulica 12 Hydraulische aansluiting Conexiones eléctricas 15 Elektrische aansluitingen Mandos y esquemas eléctricos 17 Bedieningen en schakelschema’s Leyenda 18 Legende Limpieza, Schoonmaak, mantenimiento, repuestos 37 onderhoud, wisselstukken Búsqueda de averías 38 Opsporen defecten Pérdidas de carga lado agua 39 Waterlekken Declaración de conformidad 40 Conformiteitsverklaring 2 Objetivo 3 Identificación máquina 4 Transporte Peso 4 y dimensión unidad embalado 2 3 4 5 5 5 5 37 38 39 40 ZWECKBESTIMMUNG OBJETIVO 4 6 7 8 8 9 10 11 12 15 17 18 37 38 39 40 DOEL PRIMA DI INSTALLARE L’APPARECCHIO LEGGERE ATTENTAMENTE QUESTO MANUALE CAREFULLY READ THIS MANUAL BEFORE INSTALLING THE APPLIANCE AVANT D’INSTALLER L’APPAREIL LIRE ATTENTIVEMENT CE MANUEL BEVOR DAS GERÄT INSTALLIERT WIRD, SOLLTE DIESES HANDBUCH SORGFÄLTIG GELESEN WERDEN ANTES DE INSTALAR EL APARATO LEA ATENTAMENTE ESTE MANUAL VÓÓR DE INSTALLATIE VAN HET APPARAAT NEEMT U AANDACHTIG DEZE HANDLEIDING DOOR I Ventilconvettori sono stati ideati, progettati e costruiti per riscaldare/raffrescare qualsiasi ambiente civile, industriale, commerciale e sportivo. The fan coils are conceived, designed and produced to heat/cool all civil, industrial, commercial or sports premises. Les ventilo-convecteurs ont été conçus et construits pour chauffer/rafraîchir n’importe quelle ambiance civile, industrielle, commerciale et sportive. Die Gebläsekonvektoren wurden konzipiert, entworfen und gebaut, um zivil, industriell, gewerblich und zu sportlichen Zwecken genutzte Räume zu heizen bzw. zu kühlen. Los fan coils han sido diseñados, proyectados y construidos para calentar/refrescar toda clase de ambiente domestico, industrial, comercial y deportivo. De ventilatorconvectors werden ontworpen om privé-ruimtes, industriële, commerciële en sportieve ruimtes te verwarmen/af te koelen. L’apparecchio non può essere impiegato: s PERILTRATTAMENTODELLARIA ALLAPERTO s PERLINSTALLAZIONEINAMBIENTI UMIDI s PERLINSTALLAZIONEINATMOSFERE ESPLOSIVE s PERLINSTALLAZIONEINATMOSFERE CORROSIVE 4HEAPPLIANCE MAYNOTBEUSED s FOROUTDOORAIRTREATMENT s FORINSTALLATIONINEXPLOSIVE atmospheres s FORINSTALLATIONINCORROSIVE atmospheres ,APPAREILNEPEUTPAS s POURLETRAITEMENTDELAIR ENPLEINAIR s ÐTREINSTALLÏDANSDESLOCAUX HUMIDES s ÐTREINSTALLÏDANSDES ATMOSPHÒRESEXPLOSIVES s ÐTREINSTALLÏDANSDES ATMOSPHÒRESCORROSIVES $IE'ERÊTEDARFNICHT EINGESETZTWERDENFàR s DIE!UFBEREITUNGDER,UFT im Freien s DIE)NSTALLATIONINFEUCHTEN Räumen s DIE)NSTALLATIONINEXPLOSIVER Atmosphäre s DIE)NSTALLATIONINKORROSIVER Atmosphäre Los aparatos NOSEPUEDENUSARPARA s ELTRATAMIENTODELAIREAL AIRELIBRE s SUINSTALACIØNENLOCALES HÞMEDOS s SUINSTALACIØNENATMØSFERAS EXPLOSIVAS s SUINSTALACIØNENATMØSFERAS CORROSIVAS $EVENTILATORSCONVECTORS MAGNIETWORDENGEBRUIKT s VOORDEZUIVERING VANDEBUITENLUCHT s VOORINSTALLATIE INVOCHTIGERUIMTEN s VOORINSTALLATIEINRUIMTENWAAR ONTPLOFlNGSGEVAARHEERST s VOORINSTALLATIE INCORROSIEVEOMGEVINGEN 6ERIlCARECHELAMBIENTEINCUI Ò INSTALLATO LAPPARECCHIO NON CONTENGASOSTANZECHEGENERINO UNPROCESSODICORROSIONEDELLE ALETTEINALLUMINIO -AKESURETHATTHEENVIRONMENT WHERETHEAPPLIANCEISINSTALLED DOES NOT CONTAIN SUBSTANCES THATCAUSETHECORROSIONOFTHE ALUMINIUMlNS 6ÏRIlERQUELAPIÒCEDANSLAQUELLE LAPPAREILESTINSTALLÏNECONTIENT PASDESUBSTANCESPOUVANTEN GENDRERLACORROSIONDESAILETTES ENALUMINIUM ÃBERPRàFEN DASS DER 2AUM IN DEM DAS 'ERÊT INSTALLIERT WIRD KEINE 3TOFFE ENTHÊLT DIE EINEN +ORROSIONSPROZESS DER !LUMINIUM RIPPENBEWIRKEN #OMPRUEBEQUELAESTANCIAENLA QUESEESTÈINSTALADOELAPARATO NO CONTENGA SUSTANCIAS QUE GENEREN UN PROCESO DE CORRO SIØNDELASALETASDEALUMINIO #ONTROLEEROFDEOMGEVINGWAARIN HETAPPARAATGEÕNSTALLEERDISGEEN STOFFENBEVATDIEEENROESTPROCES VANDEALUMINIUMRIBBENOPGANG BRENGEN Gli apparecchi sono alimentati con acqua calda/fredda a seconda che si voglia riscaldare o raffrescare l’ambiente. The units are supplied with hot or cold water, depending on whether the environment is to be heated or cooled. Les appareils sont alimentés avec Je nachdem, ob der Raum geheizt Los aparatos están alimentados con de l’eau chaude/froide selon qu’on oder gekühlt werden soll, werden agua caliente/fría según se desee veut chauffer ou rafraîchir l’ambiance. die Geräte mit warmem oder kaltem calentar o refrescar el ambiente. Wasser versorgt. De apparaten worden gevoed met warm/koud water, naargelang men de ruimte wenst af te koelen of te verwarmen. L’apparecchio non è destinato ad essere usato da persone (bambini compresi) le cui capacità fisiche, sensoriali o mentali siano ridotte, oppure con mancanza di esperienza o di conoscenza, a meno che esse abbiano potuto beneficiare, attraverso l’intermediazione di una persona responsabile della loro sicurezza, di una sorveglianza o di istruzioni riguardanti l’uso dell’apparecchio. This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. L’appareil n’est pas prévu pour être utilisé par des personnes (y compris les enfants) dont les capacités physiques, sensorielles ou mentales sont réduites, ou dénuées d’expérience ou de connaissance, sauf si elles ont pu bénéficier, par l’intermédiaire d’une personne responsable de leur sécurité, d’une surveillance ou d’instructions préalables concernant l’utilisation de l’appareil. Het apparaat is niet bestemd voor gebruik door personen (kinderen inbegrepen) met beperkte fysieke, sensoriële of mentale capaciteiten of met onvoldoende ervaring of kennis, tenzij ze gebruik hebben kunnen maken, dankzij het toedoen van iemand die verantwoordelijk is voor hun veiligheid, van toezicht of aanwijzingen over het gebruik van het apparaat. s FORINSTALLATIONINMOISTROOMS I bambini devono essere sorvegliati Children should be supervised to per sincerarsi che non giochino con ensure that they do not play with the appliance. l’apparecchio. 2 But Identification des machines Transport Poids et dimensions de l’unité emballée Remarques générales pour la livraison Généralités Règles fondamentales de sécurité Consignes de securité Limites d’emploi Élimination Caractéristiques techniques Choix de la position del’unite Installation mécanique Raccordement hydraulique Branchements électriques Commandes et schémas électriques Légende Nettoyage, entretien et pièces de rechange Dépannage Pertes de charge côté eau Déclaration de conformité ÍNDICE Dieses Gerät ist nicht dafür bestimmt, durch Personen (einschließlich Kinder), mit eingeschränkten physischen, sensorischen oder geistigen Fähigkeiten oder mangels Erfahrung und/oder mangels Wissen benutzt zu werden, es sei denn sie werden durch eine für ihre Sicherheit zuständige Person beaufsichtigt oder erhielten von ihr Anweisungen, wie das Gerät zu benutzen ist. Este aparato no debe ser utilizado por personas (incluidos niños) cuyas capacidades físicas, sensoriales o mentales estén disminuidas o que carezcan de experiencia y conocimientos, al no ser que ellas hayan podido beneficiar, a través de la intermediación de una persona responsable de su seguridad, de una vigilancia o de instrucciones relativas al uso del aparato. Il convient de surveiller les enfants Kinder sollten beaufsichtigt werden, Los niños han de vigilarse para Kinderen dienen onder toezicht te pour s’assurer qu’ils ne jouent pas um sicherzustellen, dass sie nicht asegurarse de que no jueguen con staan om zich ervan te verzekeren avec l’appareil. mit dem Gerät spielen. el aparato. dat zij niet met het apparaat spelen. 2A I componenti principali sono: MANTELLO DI COPERTURA in materiale sintetico antiurto. È facilmente smontabile per una completa accessibilità dell’apparecchio. The main components are: impact-proof synthetic material #!3).' It can be easily disassembled for complete access to the appliance. La griglia di ripresa dell’aria, facen- The air intake grill forming part of te parte del mobiletto, è di tipo ad the cabinet, has fixed flaps and is alette fisse e posizionato sulla par- positioned on the upper part. te superiore. De voornaamste onderdelen zijn: BEHUIZING synthetisch, schokwerend materiaal. Gemakkelijk demonteerbaar, zodat het toestel volledig toegankelijk is. La grille de reprise d'air, faisant Das zum Möbelstück gehörende Luftpartie du meuble est de type à einlassgitter besitzt feste Klappen ailettes fixes et placé sur la partie und ist auf der Oberseite angebracht. supérieure. La rejilla de recuperación del aire, que forma parte del mueble, es del tipo con aletas fijas, colocada en la parte superior. Het rooster voor luchtafname, dat deel uitmaakt van het meubel, is van het type met vaste vinnen en bevindt zich aan de bovenkant. FAN ASSEMBLY Consisting of tangential fan, particularly silent with statically and dynamically balanced plastic propeller, directly tapered onto the motor shaft. GROUPE VENTILATEUR Constitué d'un ventilateur tangentiel, particulièrement silencieux avec rotor en plastique équilibré de manière statique et dynamique, directement emboîté sur l'arbre moteur. GEBLÄSE Bestehend aus besonders leisem Tangentialventilator mit statisch und dynamisch ausgeglichenem Laufrad aus Kunststoff, das direkt mit der Motorwelle verzahnt ist. GRUPO VENTILADOR Formado por ventilador tangencial, extremadamente silencioso con rotor de plástico equilibrado estática y dinámicamente, directamente ensamblado al eje motor. VENTILATORGROEP Het bestaat uit een tangentiële ventilator, bijzonder geruisloos, met statisch en dynamisch uitgebalanceerde plastic rotor, rechtstreeks verbonden met de as van de motor. MOTORE ELETTRICO Di tipo monofase tensione 230V/50 Hz, isolamento B e klixon integrato. La variazione di velocità del ventilatore avviene con l’impiego di autotrasformatore a 6 diverse tensioni in uscita. Gli apparecchi utilizzano, come standard, 3 velocità predefinite con la possibilità, in fase di messa a punto dell’impianto, di poterle modificare. ELECTRIC MOTOR Of 230V/50 Hz single-phase voltage, B insulation and integrated klixon type. The fan's speed is changed by using an auto-transformer with 6 different output voltages. The appliances standard use 3 pre-defined speeds with the possibility of modifying them during system precision adjustment. MOTEUR ÉLECTRIQUE De type monophasé, tension 230V/50 Hz, isolation B et klixon intégré. La variation de vitesse du ventilateur s'effectue avec l'utilisation d'un autotransformateur à 6 tensions différentes en sortie. Les appareils utilisent, comme standard, 3 vitesses prédéfinies avec la possibilité, en phase de mise au point de l'installation, de pouvoir les modifier. ELEKTROMOTOR Wechselstrom Spannung 230 V/50 Hz, Isolierung B und eingebautem Klixon. Die Änderung der Ventilatordrehzahl erfolgt mithilfe eines Spartransformators mit 6 unterschiedlichen Ausgangsspannungen. Die Geräte verwenden serienmäßig 3 festgelegte Drehzahlen, die bei der Feineinstellung der Anlage geändert werden können. MOTOR ELÉCTRICO De tipo monofase con tensión de 230V/50 Hz, aislamiento B y klixon integrado. La variación de velocidad del ventilador se realiza usando el auto-transformador de 6 tensiones de salida diferentes. Los aparatos, como estándar, utilizan 3 velocidades preconfiguradas con posibilidad de modificarlas en fase de puesta a punto de la instalación. ELEKTRISCHE MOTOR Van het type monofase spanning 230V/50 Hz, isolatie B en geïntegreerde klixon. De snelheidsverandering van de ventilator gebeurt met behulp van een spaartransformator met 6 verschillende spanningen op de uitgang. De toestellen gebruiken standaard 3 vooraf gedefinieerde snelheden met de mogelijkheid om die te wijzigen tijdens de fase waarin het systeem op punt wordt gesteld. BATTERIA DI SCAMBIO TERMICO È costruita con tubi di rame ed alette in alluminio fissate ai tubi con procedimento di mandrinatura meccanica. La batteria è dotata di 2 attacchi Ø 1/2” gas femmina. I collettori delle batterie sono corredati di sfoghi d’aria e di scarichi d’acqua 1/8” gas. Ø 1/ HEAT EXCHANGE COIL Made with aluminium finned copper tubes. The exchanger has two 1/2” female gas connections. Coil headers with air vents and water drain outlets (1/8” dia. gas). BATTERIE D’ÉCHANGE THERMIQUE Construite avec des tubes en cuivre et des ailettes en aluminium fixées aux tubes par dudgeonnage mécanique. La batterie est équipée de deux raccords Ø 1/2” gaz femelle. Les collecteurs des batteries sont dotés de purgeurs d’air et de sorties d’eau Ø 1/8” gaz. WÄRMETAUSCHERBATTERIE Bestehend aus Kupferrohren mit maschinell aufgezogenen Aluminiumlamellen. Die Wärmetauscher sind mit zwei Anschlüssen mit Innengewinde ø 1/2” Gas versehen. Die Sammler der Wärmetauscher sind mit Entlüftungsöffnungen und WasserablassAnschlüssen ø 1/8” Gas versehen. BATERÍA DE INTERCAMBIO TÉRMICO Se compone de tubos de cobre y aletas en aluminio fijadas a los tubos con un procedimiento de mandrilado mecánico. La batería tiene 2 conexiones Ø 1/2” gas hembra. Los colectores de las baterías tienen alivios de aire y descargas de agua Ø 1/8” gas. BATTERIJ WARMTEWISSELING Samengesteld uit koperen buizen en aluminium ribben die met een mechanisch procédé aan de buizen bevestigd zijn. De batterij voorzien van 2 vrouwelijke gasaansluitingen van Ø 1/2” . De collectors van de batterijen zijn uitgerust met luchtuitlaten en waterafvoerpijpen van Ø 1/8” gas. POSIZIONE AS STANDARD, DI SERIE DEGLI ATTACCHI THE CONNECTIONS È A SINISTRA, ARE ON THE LEFT HAND SIDE GUARDANDO L’APPARECCHIO. G 3 Los componentes principales son: MUEBLE DE COBERTURA en material sintético antichoque. Se puede desmontar fácilmente para acceder completamente al aparato. GRUPPO VENTILATORE Costituito da ventilatore tangenziale, particolarmente silenziosio con girante in plastica bilanciata staticamente e dinamicamente, direttamente calettata sull’albero motore. LA &IG!BBh!v Das Gerät setzt sich hauptsächlich aus folgenden Bauteilen zusammen: GEHÄUSE Stoßfestes Kunststoffmaterial. Zum gänzlichen Erreichen des Geräts einfach zerlegbar. Les composants principaux sont: CARROSSERIE en matériel synthétique antichoc. Il est facilement démontable pour accéder totalement à l'appareil. FACING THE UNIT. LA POSITION STANDARD DES RACCORDS EST À GAUCHE, QUAND ON REGARDE L’APPAREIL. SERIENMÄSSIG ANSCHLÜSSE VORNE GESEHEN LINKS. LA VON POSICIÓN PREDETERMINADA DE SERIËLE POSITIE DE LAS CONEXIONES ES VAN DE AANSLUITINGEN IS LINKS, EN LA PARTE IZQUIERDA MIRANDO ALS MEN VÓÓR HET AL APARATO DESDE ENFRENTE. APPARAAT STAAT. BEFINDEN SICH DIE FILTRO di materiale sintetico rige- Regenerable synthetic FILTER nerabile. FILTRE en matière synthétique FILTER aus regenerierbarem régénérable. Synthetikmaterial. FILTRO en material sintético regenerable. Herbruikbare FILTER in synthetisch materiaal. CONDENSATE BACINELLA RACCOLTA CONDENSA in ma- DRAIN PAN, plastic, L-shaped, teriale plastico, realizzata a forma fixed to internal structure. di L e fissata alla struttura interna. BAC DE RECUPERATION An der Innenstruktur befestigte, DES CONDENSATS, en matière L-förmige KONDENSATWANNE plastique, réalisé en forme de “L“ aus Kunststoff. et fixé à la structure interne. BARDEJA DE CONDENSADOS, en material plástico, con forma de “L” y asegurada a la estructura interna. OPVANGBAK CONDENSATIEWATER, uitgevoerd in L-vorm en vastgemaakt aan de binnenstructuur. IDENTIFICAZIONE MACCHINA IDENTIFYING THE APPLIANCE IDENTIFICATION DES MACHINES KENNZEICHNUNG DES GERÄTS IDENTIFICACIÓN DE LA MÁQUINA IDENTIFICATIE APPARAAT A bordo di ogni singola macchina è applicata l’etichetta di identificazione riportante i dati del costruttore ed il tipo di macchina. Each unit is supplied with an identification plate giving details of the manufacturer and the type of appliance. Une étiquette d’identification est appliquée sur chaque machine; elle indique les données du constructeur et le type de machine. Jedes Gerät ist mit einem Typenschild gekennzeichnet, auf dem die Daten des Herstellers und der Typ des Geräts angegeben sind. Cada máquina lleva una placa de identificación en la que figuran los datos del fabricante y el tipo de máquina de que se trata. Aan boord van elk apparaat wordt een identificatielabel aangebracht met de gegevens van de fabrikant en het type machine. VEDI&IG! SEE&IG! VOIR&IG! SIEHE!BB! VÏASELA&IG! ZIE&IG! 3A TRASPORTO TRANSPORT TRANSPORT TRANSPORT TRANSPORTE TRANSPORT L’apparecchio viene imballato in The appliance is supplied in cardscatole di cartone. board packaging. L’appareil est emballé dans des El aparato viene embalado en caja Het apparaat wordt in een kartonnen boîtes en carton. Das Gerät wird in Kartons verpackt. de cartón. doos verpakt. Una volta che l’apparecchio è After unpacking the appliance, make disinballato controllare che non sure it is undamaged and corresponds vi siano danni e che corrisponda to the unit requested. alla fornitura. Après avoir déballé l’appareil, contrôler Kontrollieren Sie beim Auspacken qu’il n’a subi aucun dommage et sofort, ob das Gerät unversehrt ist, qu’il correspond bien à la fourniture. und ob es mit den Angaben in den Versandpapieren übereinstimmt. Cuando se desembala el aparato, Eens het apparaat van zijn verpakking es preciso comprobar que no tenga ontdaan, controleert u de integriteit desperfectos y que se corresponda en conformiteit van het apparaat. con el suministro previsto. In caso di danni o di sigla dell’apparecchio non corrispondente a quanto ordinato, rivolgersi al proprio rivenditore citando la serie e il modello. In the event of damage or if the identification code does not correspond to that ordered, contact your dealer immediately, quoting the series and model. En cas de dommages ou si le sigle de l’appareil ne correspond pas à ce qui a été commandé, s’adresser au revendeur en indiquant la série et le modèle. Falls Schäden festgestellt werden sollten, oder wenn die Artikelnummer nicht mit dem bestellten Gerät übereinstimmt, wenden Sie sich bitte an Ihren Händler. Geben Sie bei Rückfragen immer Serie und Gerätemodell an. En caso de daños o de sigla del aparato no correspondiente con la del pedido, dirigirse al revendedor indicando la serie y el modelo. PESI E DIMENSIONI UNITÀ IMBALLATA WEIGHTS AND DIMENSIONS PACKED UNIT POIDS ET DIMENSIONS DE L’UNITE EMBALLEE PESO GEWICHT UND DIMENSIONEN Y DIMENSIÓN VERPACKTES GERÄT UNIDAD EMBALADO 2 In geval van beschadigingen, of indien het apparaat niet overeenkomt met de bestelling, wendt u zich tot uw verkoper, met vermelding van het serienummer en het model. GEWICHT EN AFMETINGEN VERPAKTE EENHEID MOD. 1 3 4 kg 11 11 14 14 1 2 3 4 Peso - Weight - Poids - Gewicht - Peso - Gewicht 270 395 Z MOD. mm 4 Dimensioni - Dimensions - Dimensions - Dimensionen - Dimensión - Afmetingen Z 950 950 4A 1255 1255 NOTE GENERALI ALLA CONSEGNA GENERAL NOTES ON DELIVERY REMARQUES GENERALES POUR LA LIVRAISON ALLGEMEINE HINWEISE ZUR LIEFERUNG NOTAS GENERALES PARA LA ENTREGA ALGEMEINE OPMERKINGEN BIJ DE LEVERING s !PPARECCHIO s !PPLIANCE s !PPAREIL s 'ERÊT s !PARATO s !PPARAAT s ,IBRETTO di istruzioni e manutenzione. s )NSTRUCTION and maintenance manual. s )NSTRUCTIONS d’installation et d’entretien. s 'EBRAUCHS und Wartungsanleitung. s -ANUALDEINSTRUCCIONES y mantenimiento. s (ANDLEIDINGVOORHETGEBRUIK en het onderhoud. AVVERTENZE GENERALI GENERAL WARNINGS GENERALITES ALLGEMEINE HINWEISE ADVERTENCIAS GENERALES ALGEMENE VOORSCHRIFTEN Dopo aver aperto e tolto l’imballo, accertarsi che il contenuto sia quello richiesto e che sia integro. In caso contrario, rivolgersi al rivenditore ove si è acquistato l’apparecchio. After removing the packaging, make sure the contents are as requested and not damaged. If this is not the case, contact the dealer where you bought the appliance. Après avoir ouvert et retiré l’emballage, s’assurer que le contenu est conforme et qu’il est en parfait état. En cas contraire s’adresser au revendeur où l’appareil a été acheté. Nach dem Auspacken kontrollieren, ob der Inhalt der Bestellung entspricht und unversehrt ist. Im gegenteiligen Fall wenden Sie sich an Ihren Händler. Después de haber retirado el embalaje, comprobar que el contenido sea el solicitado y que esté intacto. En caso contrario, dirigirse al establecimiento donde se ha comprado el aparato. Na de verpakking te hebben verwijderd, controleren of de inhoud ervan correct en onbeschadigd is. Is dit niet het geval, contact opnemen met de verkoper of waar het apparaat werd aangekocht. ATTENZIONE! IMPORTANT! ATTENTION! ACHTUNG! ATENCIÓN! OPGELET! .ELLAPARTEINTERNA DELLIMBALLOSUPERIORE è presente LADIMADIINSTALLAZIONE 4HEINSTALLATIONTEMPLATE is present INSIDETHEUPPERPACKAGING 3URLAPARTIEINTERNE DELgEMBALLAGESUPÏRIEUR SETROUVE LEGABARITDgINSTALLATION )NDEROBEREN6ERPACKUNG BElNDETSICH DIE)NSTALLATIONSSCHABLONE %NLAPARTEINTERNA DELEMBALAJESUPERIOR SEENCUENTRALAPLANTILLA RELATIVAALAINSTALACIØN )NDEVERPAKKING BOVENAANBEVINDT ZICHHETSCHEMA VOORDEINSTALLATIE I ventilconvettori sono stati studiati per riscaldare e/o condizionare gli ambienti e devono quindi essere utilizzati solamente per questo. Si esclude qualsiasi responsabilità per i danni eventuali causati da un uso improprio. The fan coils have been designed for room heating and/or air conditioning and must be used exclusively for that purpose. We declines all responsibility for damage caused by their improper use. Les ventilo-convecteurs ont été conçus pour chauffer et/ou climatiser les pièces et ne doivent être destinés qu’à cet usage. Il exclut toute responsable en cas de dommages causés par un emploi anormal. Die Klimakonvektoren wurden zur Heizung und Klimatisierung von Räumen entwickelt und dürfen folglich ausschließlich zu diesem Zweck verwendet werden. Die Firma haftet nicht für eventuelle Schäden, die durch den unzweckmäßigen Gebrauch verursacht werden. Los fan coils se han estudiado para calentar y/o acondicionar las habitaciones y no deben usarse para otro fin. Declinamos cualquier responsabilidad por los posibles daños debidos a un uso inadecuado. De ventilatorconvectors werden ontworpen voor de verwarming en/of koeling van ruimten, en dienen uitsluitend hiervoor te worden gebruikt. Wij kunnen niet aansprakelijk worden gesteld voor eventuele schade die het gevolg is van een verkeerd gebruik van het apparaat. Questo libretto deve accompagna- This booklet is an integral part of re sempre l’apparecchio in quanto the appliance and must always parte integrante dello stesso. accompany the unit. Cette notice doit toujours accompa- Diese Betriebsanleitung ist wesent- Este manual debe acompañar Deze handleiding dient het apparaat gner l’appareil car elle en fait partie licher Bestandteil des Gerätes und siempre al aparato ya que forma steeds te vergezellen, omdat het intégrante. muss folglich immer zusammen mit parte del mismo. er wezenlijk deel van uitmaakt. diesem verwahrt werden. Ogni riparazione o manutenzione All repairs or maintenance must be dell’apparecchio deve essere ese- performed by qualified specialists. guita da personale specializzato e qualificato. Toutes les réparations ou entretiens de l’appareil doivent être effectués par le SAV ou par un technicien spécialisé. Alle Reparaturen oder Wartungsarbeiten müssen durch Personal der Firma oder andere fachlich qualifizierte Techniker erfolgen. Todas las reparaciones o mantenimiento del aparato deberán ser realizadas por personal especializado y cualificado. Non si risponde in caso di danni We declines all responsibility for provocati da modifiche o manomis- damage caused by modifications or tampering with the unit. sioni dell’apparecchio. On décline toute responsabilité en cas de dommages provoqués par des modifications ou altérations de l’appareil. Die Firma haftet nicht für solche Schäden, die durch die Veränderung oder die Manipulierung des Geräts entstehen. No se hace responsable en caso Wij kunnen niet aansprakelijk worden de daños provocados por modi- gesteld voor schade die voortvloeit ficaciones o manipulaciones del uit aangebrachte wijzigingen. aparato. 2 ø6 ø6 OK OK ø6 100mm 50mm 50mm H2O ø6 1 5 5A Reparaties of onderhoud van het apparaat dienen uitgevoerd te worden door gespecialiseerd en opgeleid personeel. REGOLE FONDAMENTALI DI SICUREZZA FUNDAMENTAL SAFETY RULES GRUNDSÄTZLICHE SICHERHEITSVORSCHRIFTEN NORMAS FUNDAMENTALES DE SEGURIDAD BELANGRIJKE VEILIGHEIDSVOORSCHRIFTEN È vietato l’utilizzo del ventilconvet- Fan coils must never be used by tore da parte di bambini o di per- children or unfit persons without supervision. sone inabili e senza assistenza. Le ventilo-convecteur ne doit pas Der Klimakonvektor darf weder von Se prohibe el uso del fan coil a los être utilisé par des enfants ou des Kindern, noch von Personen, die niños y a las personas incapacipersonnes inaptes non assitées. nicht mit seiner Bedienung vertraut tadas no asistidas. sind, benutzt werden. È pericoloso toccare l’apparecchio It is dangerous to touch the unit avendo parti del corpo bagnate ed with damp parts of the body and bare feet. i piedi nudi. Il est dangereux de toucher Das Gerät darf weder barfuß noch Es peligroso tocar el aparato te- Het is gevaarlijk het apparaat aan l’appareil si on a des parties du mit nassen oder feuchten Körper- niendo partes del cuerpo mojadas te raken wanneer delen van het y con los pies descalzos. lichaam nat zijn of men op blote corps mouillées ou les pieds nus. teilen berührt werden. voeten loopt. De ventilatorconvector dient niet te worden gebruikt door kinderen of onbekwame personen, zonder toezicht. Non effettuare nessun tipo di intervento o manutenzione senza aver prima scollegato l’apparecchio dall’alimentazione elettrica. Always unplug the unit from the mains power supply before carrying out any type of operation or maintenance. N’effectuer aucun intervention sur Das Gerät darf erst gewartet werden, No efectuar ningún tipo de interl’appareil sans l’avoir débranché nachdem die Spannungsversorgung vención o mantenimiento sin antes au préalable. unterbrochen wurde. de haber desconectado el aparato de la corriente eléctrica. Non manomettere o modificare i dispositivi di regolazione o sicurezza senza essere autorizzati e senza indicazioni. Never tamper with or modify regulation and safety devices without prior authorisation and instructions. Ne pas altérer ou modifier les Die Regel- und Sicherheitsein- No manipular o modificar los dispo- De regel- of veiligheidsinrichtingen dispositifs de réglage ou de sécurité richtungen dürfen ohne vorherige sitivos de regulación o de seguridad worden niet gehanteerd of gewijzigd sans autorisation et sans instructions. Genehmigung Firma und deren sin la autorización y indicaciones. zonder toelating. Anleitung nicht verändert oder manipuliert werden. Non torcere, staccare o tirare i cavi elettrici che fuoriescono dall’apparecchio anche se lo stesso non è collegato all’alimentazione elettrica. Never twist, detach or pull power cables, even when the unit is unplugged from the mains power supply. Ne pas tordre, détacher ou tirer les câbles électriques qui sortent de l’appareil même si celui-ci est débranché. Die aus dem Gerät kommenden Stromkabel dürfen nicht gezogen, getrennt, verdreht werden, auch dann nicht, wenn das Gerät nicht an das Stromnetz angeschlossen ist. No torcer, desconectar o tirar de los cables eléctricos que salen del aparato, aunque éste estuviera desconectado de la corriente eléctrica. Verricht geen handelingen of onderhoud aan het apparaat vooraleer dit werd losgekoppeld van het elektriciteitsnet. De stroomkabels die uit het apparaat steken, worden niet gekneld, losgekoppeld of onder trekspanning gebracht, zelfs wanneer het apparaat niet aangesloten is op het elektriciteitsnet. Non gettare o spruzzare acqua Never throw or spray water on the sull’apparecchio. unit. Ne pas jeter ou vaporiser de l’eau Das Gerät darf nicht mit Wasser No tirar o vaporizar agua sobre el Zorg ervoor dat het apparaat niet sur l’appareil. aparato. in contact komt met water. in Berührung kommen. Non introdurre assolutamente nien- Never introduce foreign objects te attraverso le griglie di aspirazio- through the air intake and discharge ne e mandata aria. grids. Ne rien introduire à travers les Keine Gegenstände durch die Luft- No introducir absolutamente nada Zorg ervoor dat niets door de grilles d’aspiration et de soufflage gitter stecken. a través de las rejillas de aspira- aanzuig- en luchtinlaatrooster kan de l’air. ción y descarga de aire. dringen. Non rimuovere nessun elemento Never remove protective elements di protezione senza aver prima without first unplugging the unit scollegato l’apparecchio dall’ali- from the mains power supply. mentazione elettrica. N’enlever aucune protection sans Die Schutzelemente dürfen erst avoir au préalable débranché dann entfernt werden, nachdem die l’appareil. Spannungsversorgung unterbrochen wurde. No retirar ningún elemento de pro- Verwijder geen enkele beveiliging tección sin antes haber desco- alvorens het apparaat losgekoppeld nectado el aparato de la corriente te hebben van het elektriciteitsnet. eléctrica. Non gettare o lasciare il materiale residuo dell’imballo alla portata dei bambini perché potenziale causa di pericolo. Ne pas jeter ou laisser l’emballage Das Verpackungsmaterial muss à la portée des enfants car il peut vorschriftsmäßig entsorgt werden, représenter un danger. und darf nicht in die Reichweite von Kindern gelangen, da es eine potentielle Gefahrenquelle darstellt. No tirar o dejar al alcance de los niños el material de embalaje ya que es una fuente potencial de peligro. Laat het verpakkingsmateriaal niet rondslingeren of binnen het bereik van kinderen, omdat het gevaarlijk kan zijn. Ne pas installer l’appareil dans une atmosphère explosive ou corrosive, dans des lieux humides, dehors ou dans des pièces où il y a beaucoup de poussière. No instalar en una atmósfera explosiva o corrosiva, en lugares húmedos, al aire libre o en lugares con mucho polvo. Stel het apparaat niet op in een explosieve of corrosieve omgeving, op een vochtige plaats, buiten of in ruimten met veel stof. Do not throw packaging material away or leave it within reach of children as it may represent a hazard. Non installare in atmosfera esplo- Do not install in explosive, corrosive siva o corrosiva, in luoghi umidi, or damp environments, outdoors all’aperto o in ambienti con molta or in very dusty rooms. polvere. 6 RÈGLES FONDAMENTALES DE SÉCURITÉ Das Gerät darf nicht in explosiver oder korrosiver Atmosphäre, im Freien oder in Räumen mit starker Staubbelastung installiert werden. 6A PRESCRIZIONI DI SICUREZZA 7 SAFETY RULES CONSIGNES DE SECURITE SICHERHEITSVORSCHRIFTEN PRESCRIPCIONES DE SEGURIDAD VEILIGHEIDSVOORSCHRIFTEN Prima di effettuare qualsiasi intervento assicuratevi che: 1 - Il ventilconvettore non sia sotto tensione elettrica. 2 - Chiudere la valvola di alimentazione dell’acqua della batteria e lasciarla raffreddare. 3 - Installare in prossimità dell’apparecchio o degli apparecchi in posizione facilmente accessibile un interruttore di sicurezza che tolga corrente alla macchina. Before carrying out any operation on the appliance, make sure: 1 - The unit is disconnected from the electrical power supply. 2 - The coil water supply valve is closed and the coil has cooled down. 3 - Install a safety switch to turn off current to the appliance in an easily accessible position near the unit or units. Avant d’effectuer toute intervention, s’assurer que: 1 - Le ventilo-convecteur n’est pas sous tension électrique. 2 - Fermer la vanne d’alimentation de l’eau de la batterie et la laisser refroidir. 3 - Installer à proximité du ou des appareils et dans une position facilement accessible un interrupteur de sécurité pour couper le courant de la machine. Vor Durchführung irgendwelcher Eingriffe: 1 - Sicherstellen, dass der Gebläsekonvektor nicht unter Spannung steht. 2 - Das Wassereinlassventil der Batterie schließen und abkühlen lassen. 3 - An einer gut zugänglichen Stelle in der Nähe des Geräts bzw. der Geräte einen Sicherheitsschalter installieren, der die Stromzufuhr zum Gerät unterbricht. Antes de efectuar cualquier operación es preciso comprobar que: 1 - El fan coil no está alimentado eléctricamente. 2 - Cerrar la válvula de alimentación del agua de la batería y dejar que se enfríe. 3 - Instalar cerca del aparato o de los aparatos, en una posición a la que se acceda fácilmente, un interruptor de seguridad que desconecte la alimentación de la máquina. Alvorens u een handeling uitvoert aan het apparaat, vergewis u ervan dat: 1 - De ventilatorconvector niet onder elektrische spanning staat. 2 - De watertoevoerklep van de batterij gesloten is. Laat deze laatste afkoelen. 3 - Installeer vlakbij het apparaat of de apparaten een makkelijk bereikbare noodschakelaar die de stroomtoevoer naar de machine onderbreekt. Durante l’installazione, la manutenzione e la riparazione, per motivi di sicurezza, è necessario attenersi a quanto segue: s 5TILIZZARE sempre guanti da lavoro. s .ONESPORRE a gas infiammabili. s .ONPOSIZIONARE sulle griglie oggetti. During installation, maintenance and repairs, for safety reasons, observe the following precautions: s $ONOTEXPOSE to inflammable gas. s $ONOTPLACEOBJECTS over the grids. Pendant l’installation, l’entretien et la réparation, pour des raisons de sécurité, il est nécessaire de respecter ce qui suit: s 5TILISERTOUJOURS des gants de travail. s .EPASEXPOSER à des gaz inflammables. s .EPLACERAUCUNOBJET sur les grilles. Aus Gründen der Sicherheit sind während der Installation, Wartung und Reparaturen, die folgenden Vorschriften einzuhalten: s 3TETS!RBEITSHANDSCHUHE tragen. s +EINENFEUERGEFÊHRLICHEN Gasen aussetzen. s .ICHTSAUFDIE!USBLASGITTER stellen. Durante la instalación, el mantenimiento y repación, por motivos de seguridad, es necesario atenerse a los siguiente: s 5SARSIEMPRE guantes de trabajo. s .OEXPONER a gases inflamables. s .ODEJAROBJETOS sobre las rejillas. Tijdens de installatie, het onderhoud en de reparaties, is het uit veiligheidsoverwegingen noodzakelijk na te leven wat volgt: s 'EBRUIKALTIJD werkhandschoenen. s .IETBLOOTSTELLEN aan brandbare gassen. s 'EENVOORWERPEN op de roosters plaatsen. Assicurarsi di collegare la messa a terra. Make sure the unit is earthed. S’assurer que la mise à la terre a été effectuée. Vergewissern Sie sich, dass das Gerät korrekt geerdet wird. Comprobar siempre que esté conectada la toma de tierra. Zorg voor een aardaansluiting. s !LWAYSUSEWORKGLOVES Per trasportare la macchina solle- When moving the appliance, lift it by varla da soli (per pesi inferiori a 30 yourself (for weights of under 30 kg) Kg) o con l’aiuto di un’altra persona. or with the help of another person. Pour transporter la machine, lav soulever Für den Transport kann das Gerät Para desplazar la máquina basta Voor het transport, heft u de machine tout seul (pour des poids inférieurs à alleine (für Gewicht unter 30 kg) una persona (para pesos inferiores alleen (voor gewichten kleiner dan 30 30 kg) ou avec l’aide d’une autre personne. oder zu zweit angehoben werden. a los 30 Kg) o dos. kg) of met de hulp van iemand anders. Sollevarla lentamente, facendo Lift it slowly, taking care not to attenzione che non cada. drop it. La soulever lentement, en faisant Langsam und vorsichtig anheben, Levantarla despacio teniendo cui- Hef de machine traag op, zonder damit es nicht herabfällt. dado en no soltarla. attention qu’elle ne tombe pas. te laten vallen. Le ventole possono raggiungere Fan blades may reach speeds of la velocità di 1000 g/min. up to 1000 revs/min. Les ventilateurs peuvent atteindre Die Laufräder können eine Drehzahl Los ventiladores pueden alcanzar De propellers kunnen een snelheid la vitesse de 1000 tr/mn. von 1.000 U/min. erreichen. una velocidad de 1000 r.p.m. van 1000 t/min. halen. Non inserire oggetti nell’elettro- Never introduce objects or the hand ventilatore nè tantomeno le mani. into the fans. Ne pas introduire d’objets dans le Stecken Sie keine Gegenstände in No introducir objetos en el ventila- Steek geen voorwerpen of handen ventilateur, et surtout pas les mains. den Ventilator, und greifen Sie erst dor ni tanto menos las manos. in de elektronventilator. recht nicht mit den Händen hinein. Non togliere le etichette di sicu- Do not remove the safety labels rezza all’interno dell’apparecchio. inside the appliance. Ne pas retirer les étiquettes de Die Sicherheitsetiketten im Geräte- No quitar las etiquetas de seguri- Verwijder de veiligheidslabels aan de sécurité à l’intérieur de l’appareil. innern dürfen nicht entfernt werden. dad presentes dentro del aparato. binnenkant van het apparaat niet. In caso di illeggibilità richiederne If you cannot read the labels, ask for replacements. la sostituzione. Si les étiquettes sont illisibles, en Falls Sie unleserlich sind, müssen Si se estropean hasta quedar ile- Als de labels niet leesbaar zijn, laat u ze vervangen. gibles es preciso sustituirlas. demander d’autres exemplaires. sie ersetzt werden. ATTENZIONE! NON TOGLIERE LA PROTEZIONE DEL CIRCUITO STAMPATO DELLA SCHEDA ELETTRONICA $!,3500/24/#/-!.$) IMPORTANT! DO NOT REMOVE THE ELECTRICAL BOARD PRINTED CIRCUIT GUARD FROM THE CONTROL UNIT -/5.4).' ATTENTION! NE PAS RETIRER LA PROTECTION DU CIRCUIT IMPRIME DE LA CARTE ELECTRONIQUE DU SUPPORT $%3#/--!.$%3 ACHTUNG! DIE SCHUTZABDECKUNG DER GEDRUCKTEN SCHALTUNG DER PLATINE DARF NICHT VON DER HALTERUNG DER STEUERUNGEN '%./--%.7%2$%. ATENCIÓN! NO QUITAR LA PROTECCIÓN DEL CIRCUITO IMPRESO DA LA TARJETA ELECTRÓNICA DEL SOPORTE $%,#/.42/, OPGELET! VERWIJDER DE BEVEILIGING VAN HET GEDRUKTE CIRCUIT VAN DE ELEKTRONISCHE SCHAKELING NIET !.$%"%$)%.).'3"!3)3 IN CASO DI SOSTITUZIONE O PULIZIA DEL FILTRO RICORDARSI SEMPRE DI REINSERIRLO PRIMA DELL’AVVIAMENTO $%,,!00!2%##()!452! IF THE FILTER REQUIRES REPLACING OR CLEANING, ALWAYS MAKE SURE IT IS REPOSITIONED CORRECTLY BEFORE 34!24).'4(%5.)4 EN CAS DE REMPLACEMENT OU DE NETTOYAGE DU FILTRE, NE JAMAIS OUBLIER DE LE REMETTRE AVANT DE METTRE ,!00!2%),%.-!2#(% BEI ERSATZ ODER REINIGUNG DES FILTERS NICHT VERGESSEN, DEN FILTER VOR DEM ERNEUTEN EINSCHALTEN DES GERÄTS WIEDER %).:5"!5%. EN CASO DE SUSTITUCIÓN O DE LIMPIEZA DEL FILTRO ACORDARSE SIEMPRE DE COLOCARLO DE NUEVO EN SU SITIO ANTES DE PONER EN MARCHA %,!0!2!4/ ALS U DE FILTER VERVANGT OF SCHOONMAAKT, PLAATST U HEM STEEDS TERUG VOOR U HET APPARAAT ).7%2+).'34%,4 In caso di sostituzione di compo- Always use original spare parts. nenti richiedere sempre ricambi originali. Si l’on doit remplacer des compo- Verlangen Sie immer Originaler- En caso de sustitución de compo- Bij de vervanging van onderdelen, sants, demander toujours des pièces satzteile. nentes, pedir siempre repuestos vraagt u steeds naar originele de rechange originales. originales. wisselstukken. In caso di installazioni in climi par- In particularly cold climates, if the ticolarmente freddi, svuotare l’im- appliance is not to be used for long pianto idraulico in previsione di periods, drain the hydraulic circuit. lunghi periodi di fermo macchina. En cas d’installation dans des climats particulièrement froids, vidanger l’installation hydraulique lorsqu’on prévoit de longues périodes d’arrêt de la machine. Bei Installation in einem besonders kalten Klima muss der Wasserkreislauf entleert werden, wenn das Gerät für längere Zeit nicht benutzt wird. En caso de instalación en climas particularmente fríos, vaciar la instalación hidráulica si se prevén largos plazos de parada de la máquina. Voor een installatie in een bijzondere koude omgeving, ledigt u de hydraulische installatie als u voorziet dat de machine gedurende een lange periode niet zal werken. Nel caso di installazione con serranda di presa d’aria esterna fare attenzione al gelo invernale che può causare la rottura dei tubi della batteria. En cas d’installation avec un volet de prise d’air extérieur, faire attention au gel en hiver, qui peut provoquer la rupture des tubes de la batterie. Achtung bei Installation mit Zuluftklappe im Freien, durch winterlichen Frost können die Rohre der Batterie beschädigt werden. En caso de instalación con toma de aire exterior tener cuidado con el hielo que puede causar la rotura de los tubos de la batería. Voor een installatie met een externe luchtklep, kijk uit voor wintervorst die de buizen van de batterij kan beschadigen. If the installation is fitted with an external air intake damper, make sure the coil tubes are not damaged by temperatures below freezing point. 7A LIMITI DI IMPIEGO OPERATING LIMITS I dati fondamentali relativi al ventil- The basic specification of the fan convettore e allo scambiatore di coil and heat exchanger is given below: calore sono i seguenti: 8 LIMITES D’EMPLOI EINSATZGRENZEN LÍMITES DE USO GEBRUIKSLIMIETEN Les caractéristiques fondamentales Die wesentlichen Daten des Klima- Los datos fundamentales relativos De belangrijke gegevens met du ventilo-convecteur et de l’échan- konvektors und der Wärmetauscher al ventilador convector y al intercam- betrekking tot de ventilatorgeur de chaleur sont les suivantes: sind die folgenden: biador de calor son los siguientes: convector en de warmtewisselaar: 6ENTILCONVETTORE ESCAMBIATOREDICALORE &ANCOIL ANDHEATEXCHANGER 6ENTILOCONVECTEUR ETÏCHANGEURDECHALEUR +LIMAKONVEKTOR UND7ÊRMETAUSCHER 6ENTILADORCONVECTOR EINTERCAMBIADORDECALOR 6ENTILATORCONVECTOR ENWARMTEWISSELAAR s 4EMPERATURAMASSIMA del fluido termovettore: max 70°C s -AXIMUM temperature of heat vector fluid: 70°C s 4EMPÏRATUREMAXIMALE du fluide caloporteur: 70°C maxi s -AX4EMPERATUR des Kältemediums: 70°C s 4EMPERATURAMÈXIMA del fluido termovector: máx. 70°C s -AXIMUMTEMPERATUUR Vloeistof Thermovector: max. 70°C s 4EMPERATURAMINIMA del fluido di raffreddamento: min 6°C s -INIMUM temperature of refrigerant fluid: 6°C s 4EMPÏRATUREMINIMALE du fluide de refroidissement: 6°C mini s -IN4EMPERATUR der Kühlflüssigkeit: 6°C s 4EMPERATURAMÓNIMA del fluido de enfriamiento: mín. 6°C s -INIMUMTEMPERATUUR koelvloeistof: min. 6°C s 0RESSIONE di esercizio massima: 1000 kPa s -AXIMUM working pressure: 1000 kPa s 0RESSION s -AX Betriebsdruck: 1000 kPa de marche maximale: 1000 kPa s -ÈXIMA presión de ejercicio: 1000 kPa s -AXIMALE bedrijfsdruk: 1000 kPa s 4ENSIONEDIALIMENTAZIONE 230V - 50Hz s 0OWERSUPPLYVOLTAGE 230V - 50Hz s 4ENSIONDALIMENTATION 230V - 50Hz s 6ERSORGUNGSSPANNUNG 230V - 50Hz s 4ENSIONESDEALIMENTACIØN 230V - 50Hz s 6OEDINGSSPANNING 230V - 50Hz s #ONSUMODIENERGIAELETTRICA vedi targhetta dati tecnici s %LECTRICENERGYCONSUMPTION see technical data label s #ONSOMMATION d’énergie électrique: voir plaquette données techniques s %NERGIEVERBRAUCH siehe Typenschild s #ONSUMODEENERGÓAELÏCTRICA ver placa de datos técnicos s %LEKTRISCH energieverbruik: zie plaatje met technische gegevens s 'RADODIPROTEZIONE)0 s )NDEXOFPROTECTION)0 s $EGRÏDEPROTECTION)0 s 3CHUTZGRAD)0 s 'RADODEPROTECCIØN)0 s "ESCHERMINGSGRAAD)0 I dati tecnici delle valvole con The technical specification of the azionatore termoelettrico sono i valves with thermoelectric actuator seguenti: is given below: Les données techniques des Die technischen Daten der thermo- Los datos técnicos de las válvulas De technische gegevens van de soupapes à actionneur thermo- elektrischen Ventile sind wie folgt: con accionador termoeléctrico son kleppen met thermo-elektrische inschakeling: électrique sont les suivantes: los siguientes: 6ALVOLECON AZIONATORETERMOELETTRICO 6ALVESWITH THERMOELECTRICACTUATOR Vannes à COMMANDETHERMOÏLECTRIQUE 6ENTILEMIT THERMOELEKTRISCHER3TEUERUNG 6ÈLVULASCON ACCIONADORTERMOELÏCTRICO +LEPPENMETTHERMO ELEKTRISCHEINSCHAKELING s Pressione di esercizio: 1000 kPa s 7ORKINGPRESSUREK0A s 0RESSIONDEMARCHEK0A s "ETRIEBSDRUCKK0A s 0RESIØNDEEJERCICIOK0A s "EDRIJFSDRUKK0A s 4ENSIONEDIALIMENTAZIONE 230V~50/60Hz s 0OWERSUPPLYVOLTAGE 230V~50/60Hz s 4ENSIONDALIMENTATION 230V~50/60Hz s 6ERSORGUNGSSPANNUNG 230V~50/60 Hz s 4ENSIØNDEALIMENTACIØN 230V~50/60Hz s 6OEDINGSSPANNING 230V~50/60Hz s 2ATINGPROTEZIONE6! 5 VA/IP 44 s 2ATING6!PROTECTION 5 VA/IP 44 s $EGRÏDEPROTECTION6!)0 s 2ATING3ICHERUNG6! 5 VA/IP 44 s 2ATINGPROTECCIØN6! 5 VA/IP 44 s 2ATING6!BESCHERMING 5 VA/IP 44 s 4EMPODICHIUSURASEC s #LOSINGTIMESEC s 4EMPSDEFERMETURESEC s 6ERSCHLUSSZEIT3EK s 4IEMPODECIERRESEG s 3LUITINGSTIJDSEC s #ONTENUTOMASSIMO di glicole nell’acqua: 50% s -AXIMUMGLYCOLCONTENT in water: 50% s #ONTENUMAXIMALDEGLYCOL dans l’eau: 50% s -AX'LYKOLANTEIL im Wasser: 50% s #ONTENIDOMÈXIMO de glicol en el agua: 50% s -AXIMAAL glycolgehalte water: 50% !LTRIDATITECNICI /THERTECHNICALDATA !UTRESDONNÏESTECHNIQUES Weitere technische Daten /TROSDATOSTÏCNICOS !NDERETECHNISCHEGEGEVENS Tutti gli altri dati tecnici importanti (dimensioni, pesi, collegamenti, rumorosità, ecc.) vengono forniti in altre parti del presente Manuale, nella documentazione tecnica a parte o nella proposta tecnica. All other important technical data (dimensions, weights, connections, noise emissions, etc.) are given elsewhere in this User Information Manual, in the separate technical documentation or in the technical proposal. Toutes les autres caractéristiques techniques importantes (dimensions, poids, raccordements, bruit etc.) sont indiquées dans d’autres parties de ce livret, dans la documentation technique à part ou dans la proposition technique. Alle anderen wichtigen technischen Daten (Abmessungen, Gewichte, Anschlüsse, Geräuschpegel, usw.) sind an anderen Stellen dieses Handbuchs, in der separaten technischen Dokumentation oder in den Angebotsunterlagen enthalten. Todos los otros datos técncicos importantes (eida, pesos, conexiones, ruido, etc.) se dan en otras partes del presente Manual, en la documentación técnica. Alle andere belangrijke technische gegevens (afmetingen, gewichten, aansluitingen, lawaai, enz.) worden geleverd in andere delen van de Handleiding, in de technische documentatie of door het technisch personeel. SMALTIMENTO WASTE DISPOSAL ÉLIMINATION ENTSORGUNG ELIMINACIÓN AFDANKING Le parti di consumo e quelle sostituite vanno smaltite nel rispetto della sicurezza e in conformità con le norme di protezione ambientale. Consumables and replaced parts should be disposed of safely and in accordance with environmental protection legislation. Les consommables et les pièces Verbrauchsteile und ersetzte Teile remplacées doivent être éliminés müssen vorschriftsmäßig entsorgt en respectant les règles de sécu- werden. rité et les normes de protection de l’environnement. Las partes de consumo y las que se sustituyen se eliminan respetando la seguridad y de acuerdo con las normas de protección del medio ambiente. De verbruiksonderdelen en vervangen onderdelen worden afgedankt met respect voor de veiligheidsvoorschriften en overeenkomstig de milieuwetgeving. 8A A B 92 CARACTERISTIQUES TECHNISCHE TECHNIQUES EIGENSCHAFTEN CARACTERÍSTICAS TÉCNICAS TECHNISCHE KARAKTERISTIEKEN 270 276 322 281 16 A TECHNICAL CHARACTERISTIC 20 CARATTERISTICHE TECNICHE 395 92 C Z A 322 DIMENSIONI - DIMENSIONS - DIMENSIONS DIMENSIONEN - DIMENSIÓN - AFMETINGEN MOD. A B C Z mm 212 1 2 3 4 880 880 1185 1185 678 678 983 983 691 691 996 996 950 950 1255 1255 ATTACCHI IDRAULICI - HYDRAULIC CONNECTIONS - WASSERANSCHLÜSSE RACCORDS HYDRAULIQUES - CONEXIONES HIDRÁULICAS - HYDRAULISCHE AANSLUITINGEN PESO - WEIGHT - POIDS GEWICHT - PESO - GEWICHT 5NITËIMBALLATA0ACKEDUNIT 5NITÏEMBALLÏE6ERPACKUNGDES'ERÊTES 5NIDADEMBALADA6ERPAKTEEENHEID OUT 34 58 8 8 ø16 1 2 3 4 1 2 3 4 kg 13 13 17 17 11 11 14 14 322 311 34 ø16 164 MOD. 12 37 IN 97 97 311 199 12 CONTENUTO ACQUA - WATER CONTENTS - CONTENANCE EAU WASSERINHALT - CONTENIDO AGUA - WATERINHOUD MOD. ,ITRI,ITERS,ITRES ,ITER,ITROS,ITER 1 2 3 4 0,85 0,85 1,28 1,28 ASSORBIMENTO MOTORE - MOTOR ABSORPTION - CONSOMMATION MOTEUR LEISTUNGSAUFNAHME MOTOR - COMSUMO MOTOR - MOTORABSORPTIE ø16 MOD. (Z 9 5NITËNONIMBALLATA5NPACKEDUNIT 5NITÏSEULE5NVERPACKUNGDES'ERÊTES 5NIDADSINEMBALAR%ENHEIDZONDERVERPAKKING W A 1 2 3 4 30 32 46 48 0,155 0,156 0,225 0,234 9A &IG" !BB" &IG# !BB# SCELTA DELLA POSIZIONE DELL’UNITÀ La posizione di installazione dell’unità, per ottenere il miglior rendimento di funzionamento ed evitare guasti o condizioni di pericolo, deve avere i seguenti requisiti: - L’altezza dal pavimento del filo inferiore dell’unità deve essere minimo di 2 m e massimo di 3 m &IG" - La parete su cui si intende fissare l’unità deve essere robusta e adatta a sostenerne il peso. - Deve essere possibile lasciare attorno all’unità uno spazio necessario per eventuali operazioni di manutenzione. - Non devono essere presenti ostacoli per la libera circolazione dell’aria sia dal lato aspirazione che, in maggior luogo, su quello di uscita aria; in questo particolare caso non deve essere presente nessun ostacolo ad una distanza inferiore i 2 m. Ciò potrebbe causare turbolenze tali da inibire il corretto funzionamento dell’apparecchio. - Deve possibilmente essere una parete esterna in modo da poter convogliare verso l’esterno il drenaggio della condensa. SELECTION OF POSITION OF THE UNIT CHOIX DE LA POSITION DE L’UNITE The position for installation of the unit, to obtain the best performance and prevent breakdowns or hazards, must have the following requisites: - The bottom of the unit must be at least 2 meters off the floor and no more than 3 &IG" Pour obtenir le meilleur rendement de fonctionnement et éviter les pannes ou les situations de danger, la position d’installation de l’unité doit avoir les caractéristiques suivantes: - La hauteur du bord inférieur de l’unité doit être au moins à 2 m et au maximum à 3 m du sol &IG" - The wall on which the unit is installed must be sturdy and able to withstand its weight. - It must be possible to leave room around the unit for any maintenance operations that may be necessary. - Le mur sur le quel on souhaite fixer l’unité doit être solide et apte à en supporter le poids. - Il faut prévoir de laisser l’espace nécessaire autour de l’unité pour d’éventuelles opérations d’entretien. - There should be no obstacles to the free circulation of air on the intake side and, especially, on the air outlet side; on this side, in particular, there should be no obstacles closer than 2 m. This could cause turbulence that would interfere with correct operation of the unit. - Il ne doit y avoir aucun obstacle pour la libre circulation de l’air tant du côté de l’aspiration que, à plus forte raison, sur celui de la sortie de l’air; pour ce dernier cas il ne doit y avoir aucun obstacle à une distance inférieure à 2 m. Cela pourrait causer des turbulences qui pourraient empêcher le fonctionnement correct del’appareil. - If possible, it should be installed on an external wall so as to convey the condensation drain outside. - Non deve essere in una posizio- - It should not be installed in a ne tale che il flusso dell’aria sia position where the air flow can rivolto direttamente alle persone strike the people underneath sottostanti &IG# directly &IG# - Non sia direttamente sopra ad - It should not be directly over un apparecchio elettrodomestico another appliance (television set, (televisore, radio, frigorifero, ecc.), radio, refrigerator, etc.), or over o sopra ad una fonte di calore a source of heat &IG$ &IG$ ELECCIÓN DE LA POSICIÓN DE LA UNIDAD POSITIONIERUNG DER EINHEIT Zur Gewährleistung einer einwandfreien Funktionsweise und zur Vorbeugung von Betriebsstörungen und Gefahren ist bei der Wahl der Stelle, an der die Einheit installiert werden soll, auf Folgendes zu achten: - Der Abstand zwischen dem Fußboden und der unteren Kante der Einheit muss mind. 2 mbis max. 3 m betragen !BB" - Die Wand, an der die Einheit befestigt wird, muss dem Gewicht derselben standhalten. - Die Einheit ist so anzubringen, dass an dieser jederzeit und problemlos eventuelle Wartungseingriffe vorgenommen werden können. - An der Luftansaug- und Luftauslassseite dürfen sich in einem Abstand von mind. 2 m keine Hindernisse befinden, da dies zu Turbulenzen führen könnte, die die einwandfreie Funktionsweise des Gerätes beeinträchtigen könnten. La posición de instalación de la unidad, para obtener el mejor rendimiento de funcionamiento y evitar daños o condiciones de peligro, tiene que tener los siguientes requisitos: - La altura desde el suelo del borde inferior de la unidad tiene que ser de un mínimo de 2 m y un máximo de 3 m &IG" - La pared sobre la que se quiere fijar la unidad tiene que ser robusta y apta para sostener el peso. - Tiene que ser posible dejar alrededor de la unidad un espacio necesario para eventuales operaciones de mantenimiento. - No tiene que haber obstáculos para la libre circulación del aire tanto del lado de aspiración que, sobre todo, del lado de salida de aire; en este caso en particular no tiene que haber ningún obstáculo a una distancia inferior de 2 m. Esto podría causar turbulencias tales que inhiban el correcto funcionamiento del equipo. Om het beste werkingsrendement te bekomen en om defecten of gevaarlijke situaties te vermijden, moet de installatiepositie van de eenheid aan de volgende vereisten voldoen: - De hoogte boven de vloer van de onderste lijn van de eenheid moet minimaal 2 m en maximaal 3 m bedragen &IG" - De wanden waarop men de eenheid wil bevestigen, moet stevig zijn en geschikt om het gewicht te dragen. - Rond de eenheid moet men voldoende ruimte kunnen laten voor eventuele onderhoudswerkzaamheden. - Er mogen geen obstakels aanwezig zijn voor de vrije luchtcirculatie, zowel aan de kant van de aanzuiging als aan de kant van de luchtuitlaat, wat nog belangrijker is; in dit laatste geval mag er geen enkel obstakel aanwezig zijn op een afstand van minder dan 2 m. Dit zou turbulenties kunnen veroorzaken, die bijgevolg de correcte werking van het toestel beletten. - Il est préférable, autant que possible, - Nach Möglichkeit sollte eine - Posiblemente tiene que ser una - Indien mogelijk moet er een externe que ce soit un mur donnant sur Außenwand vorhanden sein, damit pared externa de modo tal de wand zijn, zodat de afgevoerde l’extérieur de sorte que l’on puisse das Kondenswasser ins Freie poder transportar hacia el exterior condens naar buiten kan worden diriger le drainage de la condensation abgeleitet werden kann. el drenaje de la condensación. geleid. au dehors. - L’installation ne doit pas être dans - Bei der Installation der Einheit - No tiene que encontrarse en una - Die mag niet in een stand staan une position telle que le soufflage ist darauf zu achten, dass der posición tal que el flujo de aire se waardoor de luchtstroom rechtstreeks de l’air soit dirigé directement sur Luftstrom nicht direkt auf sich dirija directamente a las personas naar personen eronder is gericht les personnes placées au-dessous darunter befindliche Personen subyacentes &IG# &IG# gerichtet ist !BB# &IG# - Elle ne doit pas être directement - Die Einheit darf nicht über einem - No se encuentre directamente por - De positie mag niet rechtstreeks audessus d’un appareil électroElektrogerät (TV, Radio, Kühlencima de un electrodoméstico boven een huishoudtoestel ménager (téléviseur, radio, réfrischrank, usw.) oder über einer (como por ejemplo: televisor, radio, (televisie, radio, koelkast, enz.) gérateur, etc.), ou au-dessus d’une Wärmequelle installiert werden frigorífico, etc.), o sobre una fuente of boven een warmtebron zijn source de chaleur &IG$ de calor &IG$ !BB$ &IG$ &IG$ !BB$ POSITIONERINGSEENHEID ! RAFFREDDAMENTO CON FLUSSO ARIA DI COMFORT 35˚ CONTROLLO DIREZIONE FLUSSO ARIA AIR FLOW DIRECTION CONTROL CONTRÔLE DE LA DIRECTION $5&,58$g!)2 REGELUNG DER LUFTFLUSSRICHTUNG CONTROL DE LA DIRECCIÓN DEL FLUJO DE AIRE CONTROLE RICHTING LUCHTSTROOM COOLING WITH 35° COMFORT AIR FLOW REFROIDISSEMENT AVEC FLUX D'AIR DE CONFORT 35° KÜHLUNG MIT KOMFORT-LUFTFLUSS 35° ENFRIAMIENTO CON FLUJO DE AIRE DE COMFORT 35˚ KOELING MET COMFORT LUCHTSTROOM 35˚ 70° 35° FLAP FLAP FLAP FLAP FLAP FLAP GESTIONE FLUSSO ARIA VERTICALE VERTICAL AIR FLOW MANAGEMENT '%34)/.$5&,58$g!)2 VERTICAL STEUERUNG VERTIKALER LUFTFLUSS GESTIÓN DEL FLUJO DE AIRE VERTICAL BEHEER VERTICALE LUCHTSTROOM Il flusso aria verticale è regolabile manualmente. The vertical air flow can be manually adjusted. Le flux d'air vertical peut être réglé manuellement. Der vertikale Luftfluss kann manuell geregelt werden. El flujo de aire vertical puede regularse de forma manual. De verticale luchtstroom kan handmatig worden geregeld. RISCALDAMENTO CON FLUSSO ARIA DI COMFORT 70˚ HEATING WITH 70° COMFORT AIR FLOW CHAUFFAGE AVEC FLUX D'AIR DE CONFORT 70° HEIZUNG MIT KOMFORT-LUFTFLUSS 70° CALEFACCIÓN CON FLUJO DE AIRE DE COMFORT 70˚ VERWARMING MET COMFORT LUCHTSTROOM 70˚ 30° 30° ALETTE FLAPS AILETTES KLAPPEN ALETAS VINNEN GESTIONE FLUSSO ARIA ORIZZONTALE HORIZONTAL AIR FLOW MANAGEMENT '%34)/.$5&,58$g!)2 HORIZONTAL STEUERUNG HORIZONTALER LUFTFLUSS GESTIÓN DEL FLUJO DE AIRE HORIZONTAL BEHEER HORIZONTALE LUCHTSTROOM Il flusso aria orizzontale (destra/sinistra) è regolabile manualmente. The horizontal air flow (right/left) can be manually adjusted. Le flux d'air horizontal (droit/gauche) peut être réglé manuellement. Der horizontale Luftfluss (rechts/links) kann manuell geregelt werden. El flujo de aire horizontal (derecha/izquierda) puede regularse de forma manual. De horizontale luchtstroom (rechts/links) kan handmatig worden geregeld. ATTENZIONE! ,AREGOLAZIONEVAEFFETTUATA CONImAPFERMI ATTENTION! &LAPSMUSTBESTOPPED WHENADJUSTING ATTENTION! ,ERÏGLAGEDOITÐTREEFFECTUÏ AVECLESmAPSËLgARRÐT !#(45.'$IE2EGELUNG HATBEISTILLSTEHENDEN+LAPPEN ZUERFOLGEN ATENCIÓN! ,AREGULACIØNSEHACE CONLOSmAPSPARADOS /0'%0!34$EREGELING MOETWORDENUITGEVOERDTERWIJL DEmAPSGESTOPTZIJN È possibile regolare le alette fino ad un massimo di 30° a destra e fino ad un massimo di 30° a sinistra. The flaps can be adjusted up to a maximum of 30° to the right and up to a maximum of 30° to the left. Il est possible de régler les ailettes jusqu'à 30° maximum à droite et jusqu'à 30° maximum à gauche. Die Klappen können bis maximal 30° rechts und bis maximal 30° links eingestellt werden. Pueden regularse las aletas hasta un máximo de 30° hacia la derecha y hasta un máximo de 30° hacia la izquierda. De vinnen kunnen worden geregeld tot een maximum van 30° naar rechts en tot een maximum van 30° naar links. La direzione e la portata del flusso dell’aria devono essere regolate in modo che l’aria dall’unità non soffi direttamente sulle persone che sono nel locale. The air flow rate and direction must be adjusted so the air from the unit does not directly blow on people present in the room. La direction et le débit du flux d'air doivent être réglés afin que l'air de l'unité ne souffle pas directement sur les personnes qui sont dans la pièce. Die Richtung sowie der Durchsatz des Luftflusses müssen so geregelt werden, dass die aus der Einheit austretende Luft nicht direkt die Personen im Raum trifft. La dirección y la capacidad del flujo del aire deben regularse de manera que el aire de la unidad no sople directamente hacia las personas que están en la habitaciónœ. De richting en het debiet van de luchtstroom moeten worden geregeld zodat de lucht van de eenheid niet rechtstreeks op personen in het lokaal gaat blazen. ! INSTALLAZIONE MECCANICA MECHANICAL INSTALLATION B INSTALACIÓN MECÁNICA MOD. B C 1–2 3–4 678 983 691 996 OK OK 276 281 MECHANISCHE INSTALLATION 5 4 1 INSTALLATION MECANIQUE ø6 C 2 4 0ARETIINCARTONGESSOOLEGNO 7OODORPLASTERBOARDWALLS 10 3 6 -URSENPLACOPLÉTREOUENBOIS 7ÊNDEAUS'IPSKARTONODER(OLZ 0AREDESDECARTØNYESOODEMADERA 7ANDENINGIPSPLAATOFHOUT 2 1 ! MECHANISCHE INSTALLATIE COLLEGAMENTO IDRAULICO OUT IN HYDRAULIC CONNECTIONS RACCORDEMENT HYDRAULIQUE ENLACE WASSERANSCHLUSS HIDRÁULICO HYDRAULISCHE AANSLUITING PRESSIONE MASSIMA $)%3%2#):)/K0A MAXIMUM WORKING 02%3352%K0A PRESSION MAXI $%3%26)#%K0A MAXIMALE "%42)%"3$25#+K0A PRESIÓN MÁXIMA $%/0%2!#)».K0A MAXIMALE "%$2)*&3$25+K0A USARE SEMPRE CHIAVE E CONTROCHIAVE PER L’ALLACCIAMENTO DELLA BATTERIA !,,%45"!:)/.) ALWAYS USE TWO SPANNERS TO CONNECT THE HEAT EXCHANGER 4/4(%0)0%3 UTILISER TOUJOURS UNE CLE ET UNE CONTRE-CLE POUR LE RACCORDEMENT DE LA BATTERIE !58459!54%2)%3 FÜR DEN ANSCHLUSS DER BATTERIE AN DIE ROHRLEITUNGEN IMMER SCHLÜSSEL UND GEGENSCHLÜSSEL "%.54:%. USAR SIEMPRE LLAVE Y CONTRALLAVE PARA ENLAZAR LA BATERÍA !,!345"%2¶!3 GEBRUIK STEEDS SLEUTELS EN TEGENSLEUTELS OM DE BATTERIJ TE VERBINDEN -%4$%"5):%. PREVEDERE SEMPRE UNA VALVOLA DI INTERCETTAZIONE $%,&,533/)$2!5,)#/ ALWAYS FIT A GATE VALVE ).4(%7!4%2#)2#5)4 PREVOIR TOUJOURS UNE VANNE D’ARRET $5&,58(9$2!5,)15% IMMER EIN SPERRVENTIL DES WASSERFLUSSES ).34!,,)%2%. PREVER SIEMPRE UNA VÁLVULA DE ABRE-CIERRE DEL FLUJO HIDRÁULICO VOORZIE STEEDS EEN 2%4/52+,%0 ATTENZIONE! È CONSIGLIATO SIFONARE LO SCARICO DELLA CONDENSA, INSTALLARE IL TUBO DI SCARICO CONDENSA CON UNA PENDENZA $)!,-%./CMMETRO IMPORTANT! YOU ARE RECOMMENDED TO FIT A SIPHON ON THE CONDENSATE $2!).).34!,, A CONDENSATE DRAIN PIPE WITH A SLOPE OF !4,%!34CMMETRE ATTENTION! IL EST CONSEILLE DE SIPHONER L’EVACUATION DES CONDENSATS ET D’INSTALLER LE TUYAU D’EVACUATION DES CONDENSATS AVEC UNE PENTE $!5-/).3CMM ACHTUNG! DER KONDENSATAUSLASS SOLLTE MÖGLICHST MIT EINEM SIPHON VERSEHEN, UND DIE KONDENSATABLAUFLEITUNG MIT EINER NEIGUNG VON -).$%34%.3CM-ETER ).34!,,)%247%2$%. ATENCIÓN! SE ACONSEJA COLOCAR UN SIFÓN EN LA DESCARGA DEL CONDENSADO, INSTALAR EL TUBO DE DESCARGA DEL CONDENSADO CON UNA PENDIENTE DE 0/2,/-%./3CMMETRO OPGELET! HET IS RAADZAAM DE AFVOERBUIS VAN HET CONDENSATIEVOCHT TE HEVELEN, EN DE AFVOERBUIS TE INSTALLEREN MET EEN HELLING VAN MINSTENS CMMETER Nel caso l’apparecchio sia fornito If the unit is fitted with a valve, di valvola collegare i tubi di colle- connect the connection pipes to gamento alla valvola stessa. the valve. Si l’appareil est équipé d’une vanne, Falls das Gerät mit Ventil ausgestattet Si el aparato lleva válvula, conectar Indien het apparaat uitgerust is met brancher les tuyauteries de raccorde- ist, die Anschlussleitungen mit dem los tubos de enlace con la propia een klep, sluit u de buizen rechtstreeks ment à cette même vanne. Ventil verbinden. aan op de klep. válvula. Se l’apparecchio è usato per raf- If the unit is used for cooling, freddare, per evitare gocciolamento insulate the pipes and valve to di condensa, isolare le tubazioni e avoid drops of condensate forming. la valvola. Si on utilise l’appareil pour rafraîchir, isoler les tuyauteries et la vanne afin d’éviter des égouttements de condensats. Wenn das Gerät zum Kühlen benutzt wird, müssen die Rohrleitungen und das Ventil isoliert werden, um ein Heraustropfen von Kondenswasser zu vermeiden. Si se usa el aparato para enfriar, para evitar goteos de condensado es preciso aislar las tuberías y la válvula. Als het apparaat wordt gebruikt om af te koelen, en om het druppelen van condenswater te voorkomen, isoleert u de buizen en de klep. Nei periodi estivi e per lunghi periodi di tempo con il ventilatore disinserito, per evitare formazioni di condensa all’esterno dell’apparecchio, si consiglia di intercettare l’alimentazione della batteria. During the summer and when the fan is inactive for long periods, you are recommended to shut off the water supply to the coil to avoid condensation forming on the outside of the unit. Pendant l’été et lorsque le ventilateur reste longtemps débranché, il est conseillé d’isoler l’alimentation de la batterie afin d’éviter les formations de condensation à l’extérieur de l’appareil. Im Sommer und wenn der Ventilator für längere Zeit nicht benutzt wird, empfiehlt sich, die Zuleitung zur Batterie zu sperren, damit sich außen am Gerät kein Kondenswasser bildet. En las temporadas veraniegas y cuando se prevea dejar apagado el ventilador por mucho tiempo, para evitar formaciones de condensado al exterior del aparato se aconseja interceptar el agua de alimentación de la batería. In de zomermaanden en indien de ventilator lange tijd niet wordt gebruikt, is het raadzaam de voeding van de batterij te onderbreken, om de vorming van condensatievocht aan de buitenkant van het apparaat te voorkomen. Nel caso venga richiesta la vaschetta supplementare, raccolta condensa, questa va fissata alla struttura dal lato attacchi e il tubo di scarico condensa va collegato a quest’ultima. If a supplementary condensate drain pan is used, this should be fixed to the connections side of the frame and the condensate drain pipe should be fastened to the latter. Si le bac supplémentaire (de récupération des condensats) est demandé, il doit être fixé à la structure du côté des raccords et le tuyau d’évacuation des condensats doit être raccordé à ce bac. Falls eine zusätzliche Kondensatwanne verlangt wird, wird diese auf der Anschlussseite an der Struktur befestigt und die Kondensatablaufleitung wird daran angeschlossen. En el caso de que se requiera la pileta suplementaria, de recogida del condensado, es preciso fijarla a la estructura por el lado conexiones y el tubo de descarga del condensado debe conectarse a esta última. Als voor het opvangen van het condensatievocht het gebruik van een bijkomende opvangbak wordt gevraagd, wordt deze bevestigd aan de structuur, aan de zijde van de aansluitingen; de afvoerbuis wordt aangesloten aan deze laatste. 8 3% ! Collegamenti eseguiti 3 in fabbrica 4 Ventilatore Fan Ventilateur Ventilator Ventilador Ventilator 2 Scambiatore di calore 2 Heat exchanger 2 Échangeur de chaleur 2 Wärmetauscher 2 Intercambiadores de calor 2 Warmtewisselaar 3 Sfiato aria manuale 3 Air valve 3 Purgeur air manuel 3 Manuelle Entlüftung 3 Purgador de aire manual 3 Handmatige ontluchting 4 Giunto di collegamento (fornito a corredo) 4 Joint (supplied) 4 Manchette de raccord (fourni) 4 Anschluss (mitgeliefert) 4 Verbindingselement 4 Junta de conexión (entregada juntocon el aparato) (meegeleverd) 5 Valvola di intercettazione a sfera 5 Ball shutoff valve 5 Vanne d’arrêt à bille 5 Kugelabsperrventil 5 Válvula de corte de esfera 5 Connections carried out in the factory Collegamenti a cura Uscita Outlet Sortie Raccordements effectués en usine dell’installatore Connections carried out by the installer Werksseitig ausgeführte Anschlüsse 3 4 5 Conexiones realizadas en fábrica Austritt Salida Raccordements à réaliser par l'installateur 1 2 3 1 4 5 Entrata Inlet Entrée 2 3 4 5 ! Eintritt Entrada 5 Kogelafsluitklep Vom Installateur auszuführende Anschlüsse Conexiones que debe realizar el instalador 6ALVOLAAVIEPERBATTERIAPRINCIPALEFVBS 6ALVOLAAVIEPERBATTERIAPRINCIPALEFV2S Valvola acqua a tre vie ON-OFF 230 V e kit di montaggio (accessorio optional). Valvola a 2 vie ON-OFF 230 V (accessorio optional). FVBS MAINBATTERYWAYVALVE FV2S WAYVALVEFORMAINCOIL Control valve kit: 3 way valve, ON-OFF, with electric motor and mounting kit (optional). Control valve kit: 2 way valve, ON-OFF, with electric motor and mounting kit (optional). 6ANNEPOURBATTERIEPRINCIPALEFVBS 6ANNEPOURBATTERIEPRINCIPALEFV2S Vanne 3 voies (ON-OFF), 230V et kit de montage (option). Vanne 2 voies (ON-OFF), avec servomoteur et kit de montage (option). 7EGE7ASSERVENTILFàR(AUPTREGISTERFVBS 7EGE7ASSERVENTILFàR(AUPTREGISTERFV2S 3-Wege-Wasserventil ON-OFF 230 V mit elektrischem Motor und Montage KIT (optional). 2-Wege-Wasserventil ON-OFF 230 V mit elektrischem Motor und Montage KIT (optional). 6ÈLVULAPARABATERÓAPRINCIPALFV2S Válvula eléctrica de dos vías ON-OFF, con actuador eléctrico y kit de montaje (opción). +LEPVOORHOOFDBATTERIJFVBS 4WEEWEGSHOOFDKLEPVOORHOOFDBATTERIJFV2S Driewegswaterklep ON-OFF, met elektrische bediening en montagekit (optioneel accessoire). Tweewegsklep ON-OFF 230 V (optioneel accessoire). 190 190 6ÈLVULAPARABATERÓAPRINCIPALFVBS Válvula agua de tres vías ON-OFF, con actuador eléctrico y kit de montaje (opción). OUT 40 40 OUT IN 63 63 IN 31 31 56 77 6ALVOLA 6ALVE Vanne 7ASSERVENTIL 6ÈLVULA +LEP Kvs 2,5 Dp - kPa Kvs 1,6 40 30 20 MOD. DN (Ø +VS 10 9 8 7 6 5 1–2 3–4 15 20 1/2” G 3/4” G 1,6 2,5 56 77 Non montata .OTlTTED À monter Nicht Montiert .OMONTADA .IETGEMONTEERD #ODICE#ODE!RT.R#ØDIGO VIEWAYVOIES VIEWAYVOIES 7EGEVÖAS 7EGEVÖAS $RIEWEGSWATERKLEP 4WEEWEGSKLEP 9025321W/H 9025323W/H 9025311W/H 9025313W/H 4 3 2 Portata acqua (l/h) - Water flow (l/h) Débit d’eau (l/h) - Wasserdurchflussmenge (l/h) Caudal de agua (l/h) - Waterdebiet (l/h) 1 100 200 300 400 600 800 1000 2000 3000 4000 ! COLLEGAMENTI ELETTRICI ELECTRICAL CONNECTIONS BRANCHEMENTS ELECTRIQUES ELEKTROANSCHLÜSSE CONEXIONES ELECTRICAS ELEKTRISCHE AANSLUITINGEN 0RESCRIZIONIGENERALI 'ENERALINSTRUCTIONS Instructions !LLGEMEINE!NWEISUNGEN 0RESCRIPCIONESGENERALES !LGEMENEVOORSCHRIFTEN s 0RIMA DI INSTALLARE IL VENTILCON s Before installing the fan coil, make vettore verificare che la tensione sure the rated voltage of the power nominale di alimentazione sia supply is 230V - 50 Hz. di 230V - 50 Hz. s !VANT DINSTALLER LE VENTILOCON s 6OR DER )NSTALLATION DES +LIMA s !NTES DE INSTALAR EL VENTILADOR s !LVORENS DE VENTILATORCONVECTOR vecteur vérifier que la tension convector verificar que la tensión te installeren, wordt gecontroleerd konvektors sicherstellen, dass d’alimentation nominale est de nominal de alimentación sea de of de nominale voedingsspanning die nominale Versorgungs230V - 50Hz. 230 V - 50 Hz. gelijk is aan 230V - 50 Hz. spannung 230V - 50 Hz beträgt. s !SSICURARSI CHE LIMPIANTO ELET s -AKE SURE THAT IN ADDITION TO trico sia adatto ad erogare, oltre supplying the working current alla corrente di esercizio richierequired by the fan coil, the mains sta dal ventilconvettore, anche la electrical supply is also able to corrente necessaria per alimensupply the current necessary to operate other household tare elettrodomestici ed appaappliances and units. recchi già in uso. s 3ASSURER QUE LA PUISSANCE DE s 3ICHERSTELLEN DASS DIE %LEKTRO s Asegurarse de que la instalación s 7AAKEROVERDATDEELEKTRISCHE l’installation électrique est suffieléctrica sea apta para distribuir, installatie in staat is om, naast anlage in der Lage ist, neben sante pour fournir le courant de además de la corriente de ejerde bedrijfstroom vereist door de dem Klimakonvektor auch die marche pour le ventilo-convecteur cicio requerida por el ventilador ventilatorconvector, de nodige anderen Haushaltsgeräte zu ainsi que le courant nécessaire convector, la corriente necesaria energie te leveren voor de voeding versorgen. pour alimenter les électroménagers para alimentar electrodomésticos van de reeds in gebruik zijnde et les appareils déjà utilisés. que ya se estuvieran usando. huishoudtoestellen en apparaten. s Effettuare i collegamenti elettrici s 0ERFORM ELECTRICAL CONNECTIONS secondo le leggi e le norme nain accordance with laws and zionali vigenti. regulations in force in the country concerned. s %FFECTUER LES BRANCHEMENTS s $IE %LEKTROANSCHLàSSE MàSSEN s %FECTUARLASCONEXIONESELÏCTRI s $E ELEKTRISCHE AANSLUITINGEN électriques selon la législation et cas de acuerdo con las leyes y uitvoeren volgens de geldende gemäß der einschlägigen Gesetze les normes nationales en vigueur. las normativas nacionales vigentes. nationale wetgevingen en normen. und Vorschriften hergestellt werden. s A monte dell’unità prevedere un s 5PSTREAM OF THE UNIT lT AN omnipolar switch with minimum interruttore onnipolare con distanza minima dei contatti di 3,5 contact distance of 3,5 mm. mm. s %N AMONT DE LUNITÏ PRÏVOIR UN s $EM 'ERÊT EINEN ALLPOLIGEN s Prever, más arriba de la unidad, s Stroomopwaarts van de eenheid interrupteur unipolaire avec un interruptor omnipolar con una wordt een meerpolige schakelaar Schalter mit einer Kontaktöffnung distancia mínima de los contacvoorzien met een minimale afstand distance minimum des contacts von mindestens 3,5 mm vorschalten. de 3,5 mm. tos de 3,5mm. tussen de polen van 3,5 mm. Occorre sempre effettuare la mes- The unit must always be earthed. sa a terra dell’unità. Il faut toujours effectuer la mise à Das Gerät vorschriftsmäßig erden. Realizar siempre la toma de tierra De eenheid moet in elk geval worden la terre de l’unité. de la unidad. uitgerust met een aardaansluiting. Togliere sempre l’alimentazione Always disconnect the electrical elettrica prima di accedere alla power supply before opening the unit. macchina. Débrancher toujours la machine Vor dem Zugriff auf das Geräte- Retirar siempre la corriente eléctri- Koppel altijd eerst de elektrische avant d’y accéder. innere stets die Spannungs- ca antes de acceder a la máquina. voeding los alvorens aan het apparaat te komen. versorgung unterbrechen. )NDICAZIONI PERILCOLLEGAMENTO )NDICATIONS POURLERACCORDEMENT !NLEITUNGEN FàRDEN!NSCHLUSS )NDICACIONES PARALACONEXIØN !ANWIJZINGEN VOORDEAANSLUITING L’appareil est équipé d’un bornier de raccordement placé sur le côté intérieur, du côté opposé aux raccords hydrauliques. Le raccordement doit être effectué en respectant les schémas électriques donnés dans cette notice. Das Gerät ist mit einer Anschlussklemmleiste ausgestattet, die an der inneren Seitenwand, gegenüber den Wasseranschlüssen untergebracht ist. Für den Anschluss müssen die in dieser Betriebsanleitung enthaltenen Schaltpläne befolgt werden. El aparato está equipado con una caja de bornes de conexión situada en el lateral interno, en el lado opuesto a las conexiones hidráulicas. La conexión se tiene que realizar respetando los esquemas eléctricos que figuran en el presente manual. Het apparaat is uitgerust met een aansluitklemmenbord dat zich aan de binnenkant bevindt, op de wand tegenover de hydraulische aansluitingen. De aansluiting dient te worden uitgevoerd conform de schakelschema’s in deze handleiding. L’installatore dovrà prevedere l’in- The installer must bring the connecting gresso dei cavi di collegamento wires into the unit through the access utilizzando gli accessi previsti, ov- points provided: vero: L’installateur devra prévoir l’entrée Der Installateur muss die Durchdes câbles de raccordement en uti- gänge der Anschlusskabel an den lisant les accès prévus, c’est-à-dire: vorhergesehenen Stellen ausführen, und zwar: El instalador deberá prever la entrada de los cables de conexión usando los accesos previstos, es decir: De monteur zal een kabelingang moeten verwezenlijken door de toegangen die voorzien werden te gebruiken, d.w.z.: s DA MURO UTILIZZANDO LAPERTURA s WALLMOUNTED USING THE REAR posteriore resa disponibile in access point corresponding to corrispondenza della fiancata. the side panel. s sur le mur en utilisant l’ouverture s Von der Wand her unter Verwendung s DESDELAPAREDUSANDOLAAPER s aan de muur door de beschikbare tura posterior disponible en el postérieure disponible près du opening achteraan te gebruiken, der hinteren Öffnung auf Höhe lateral. côté. overeenstemmend met de zijkant. der Seitenwand. L’apparecchio è equipaggiato di una morsettiera di collegamento posta sulla fiancata interna, lato opposto attacchi idraulici. Il collegamento deve essere effettuato rispettando gli schemi elettrici riportati sul presente libretto. La morsettiera montata sul ventilconvettore è già predisposta per il collegamento ai diversi comandi secondo le indicazioni fornite nella sezione “Comandi e Schemi elettrici”. Connection instructions The unit is fitted with a connection terminal board on the internal side panel on the opposite side to the hydraulic couplings. To connect, respect the wiring diagrams in this booklet. The terminal board on the fan coil is designed for connection to the various controls following the instructions provided in the section “Controls and Electrical Wiring Diagrams”. Le bornier monté sur le ventiloconvecteur est déjà prêt pour la connexion des différentes commandes selon les instructions fournies dans la section “Commandes et Schémas électriques”. Die am Klimakonvektor montierte Klemmleiste ist bereits für den Anschluss der verschiedenen Steuerungen gemäß der Anleitungen des Kapitels “Steuerungen und Schaltpläne” vorbereitet. La caja de bornes montada sobre el ventilador convector ya está preparada para la conexión a los distintos mandos de acuerdo con las indicaciones dadas en la sección “Mandos y Esquemas eléctricos”. ! Het klemmenbord gemonteerd op de ventilatorconvector is al uitgerust voor de verbinding met de verschillende bedieningen volgens de aanwijzingen in de afdeling “Bedieningen en elektrische schema’s”. 230Vac 50Hz COMMANDES ET SCHEMAS ELECTRIQUES I venticonvettori sono dotati di mor- The fan coils have a screw terminal settiera alla quale vanno allacciati i board to which the wires from the fili provenienti dal comando remoto. remote control unit are connected. Les ventilo-convecteurs sont équipés d’un bornier à vis dans lequel doivent être raccordés les conducteurs provenant de la commande à distance. Al comando può essere allacciato un solo ventilconvettore; per ottenere il controllo di più ventilconvettori con un unico comando è necessario che ogni apparecchio sia corredato di un selettore di velocità SEL che, su segnale del comando remoto centralizzato, azionerà il proprio apparecchio. Only one fan coil can be connected to the control unit. To control more than one fan coil with a single control unit, each appliance must be fitted with an SEL speed selector which controls that particular unit according to the signal received from the centralised remote control unit. I ventilconvettori dispongono di un ventilatore con motore a 6 velocità di cui solo 3 collegate alla morsettiera. Le velocità motore sono ottenute a mezzo di un autotrasformatore. Se si volesse intervenire in cantiere sulle velocità è sufficiente spostare il collegamento dei cavi velocità (rosso, arancio e nero) collegati all’autotrasformatore seguendo la numerazione indicata nello schema. La connessione nr. 6 dell’autotrasformatore corrisponde alla velocità 1 della tabella riportata sul catalogo commerciale. A seguire tutte le altre velocità. The fan coil comes equipped with a fan that has a 6 speed motor, of which only 3 are connected to the terminal board. Motor speeds are obtained through an auto-transformer. If wanting to make changes to the speed on the spot, it is sufficient to move the speed cable connections (red, orange and black), that are connected to the auto-transformer, following the numbering in the diagram. The no. 6 connection on the auto-transformer corresponds to speed 1 from the table included in the sales catalogue. All other speeds follow the same connection logic. MANDOS Y ESQUEMAS ELÉCTRICOS BEDIENINGEN EN ELEKTRISCHE SCHEMA’S Die Gebläsekonvektoren sind mit Schraubklemmenbrett ausgestattet, in das das am Gerät zu befestigende Steuerungsklemmenbrett gesteckt werden muss bzw. an das die von der Fernsteuerung kommenden Drähte angeschlossen werden müssen. Los ventiloconvectores están dotados de regleta a la que se conectan los cables procedentes del mando a distancia. De ventilatorconvectors zijn voorzien van een klemmenbord met schroeven waarin het mannelijke klemmenbord van de bediening dat aan boord bevestigd moet worden of waaraan de snoeren die uit de afstandsbediening komen vastgekoppeld moeten worden. A la commande ne peut être raccordé qu’un seul ventilo-convecteur. Pour obtenir le contrôle de plusieurs ventilo-convecteurs avec une seule commande, il faut que chaque appareil soit équipé d’un sélecteur de vitesse SEL. Sur signal de la commande à distance centralisée, chaque sélecteur actionnera l’appareil sur lequel il est installé. An der Steuerung kann nur ein Gebläse-konvektor angeschlossen werden. Um mehrere Gebläsekonvektoren mit einer einzigen Steuerung zu bedienen, muss jedes Gerät mit einem Drehzahlwählschalter SEL ausgestattet werden, der auf Signal der zentralisierten Fernbedienung sein Gerät betätigt. Con el control es posible conectar un solo fan coil. Para lograr controlar varios fan coils mediante un solo control es preciso que cada aparato tenga un selector de velocidad, SEL el cual, sobre la base de la señal del mando a distancia centralizado, accionará al propio aparato. Aan de bediening kan slechts één ventilatorconvector worden gekoppeld; om meerdere ventilatorconvectors te bedienen met één enkele bediening, moet elk apparaat uitgerust zijn met een snelheidsschakelaar SEL die, op een signaal van de centrale afstandsbediening, zijn aangesloten apparaat in werking stelt. Les ventilo-convecteurs disposent d’un ventilateur équipé d’un moteur à 6 vitesses dont seulement 3 sont branchés sur le bornier. Les vitesses du moteur sont obtenues au moyen d’un autotransformateur. Si l’on voulait intervenir sur le chantier sur les vitesses il suffit de déplacer le branchement des câbles de la vitesse (rouge, orange et noir) reliés à l’autotransformateur en suivant la numération indiquées sur le schéma. La connexion n.6 de l’autotransformateur correspond à la vitesse 1 du tableau mentionné sur le catalogue commercial. Ainsi de suite pour toutes les autres vitesses. Die Gebläse-Konvektoren besitzen einen Gebläsemotor mit 6 Drehzahlstufen, von denen nur 3 an die Klemmleiste angeschlossen sind. Die Motordrehzahlen werden über einen Spartransformator geregelt. Sollen die Drehzahlen vor Ort geändert werden, genügt es, die Anschlüsse der am Spartransformator angeschlossenen Drehzahlkabel (rot, orange und schwarz) zu versetzen und dabei die im Plan angegebene Nummerierung zu beachten. Anschluss Nr. 6 des Spartransformators entspricht Drehzahl 1 der im Verkaufskatalog abgedruckten Tabelle. Analog für alle anderen Drehzahlen. Los ventiloconvectores cuentan con un ventilador con motor de 6 velocidades, de las cuales sólo 3 conectadas al bornero. Las velocidades del motor se obtienen mediante un autotransformador. Si en la obra se desea intervenir sobre las velocidades, es suficiente desplazar la conexión de los cables de velocidad (rojo, anaranjado y negro) conectados al autotransformador siguiendo la numeración que se muestra en el esquema. La conexión nr. 6 del autotransformador corresponde a la velocidad 1 de la tabla presente en el catálogo comercial. Y así sucesivamente para las otras velocidades. De ventilators-convectors beschikken over een ventilator met motor op 6 snelheden, waarvan slechts 3 aangesloten op het klemmenbord. De motorsnelheden worden verkregen door middel van een autotransformator. Indien men op de werf wenst in te grijpen op de snelheden, volstaat het de aansluiting van de snelheidkabels (rood, oranje en zwart) aangesloten op de autotransformator te verplaatsen volgens de nummering aangeduid in het schema. De aansluiting nr. 6 van de autotransformator komt overeen met de snelheid 1 van de tabel vermeld op de commerciële catalogus. Werk naar analogie voor alle andere snelheden. GNYE PE L N ELECTRICAL COMANDI CONTROLS AND E SCHEMI ELETTRICI WIRING DIAGRAMS 6 7 8 9 10 11 12 13 14 15 MFC BK 5 RD 4 BU OG N BU GNYE PE L BN M E GNYE 230V 50Hz GNYE 230Vac 5 6 3 4 Speed 1 2 STEUERGERÄTE UND SCHALTPLÄNE (N) BU M RD (I) OG (II) BK (III) ! LEGENDA LEGEND LÉGENDE MC MC MC = Morsettiera del cablaggio MFC = Morsettiera del FAN COIL M = Motoventilatore E = Valvola acqua (IMPIANTO A 2 TUBI) % = Valvola acqua CALDA o resistenza elettrica E2 = Valvola acqua FREDDA CH 1 GNYE RD OG BK BN BU = = % = = MC LEGENDE MC = Klemmenbord bekabeling MFC = Klemmenbord ventilatorconvector M = Motorventilator E = Waterklep (2-buizige installatie) % = Klep WARM water of elektrische weerstand E2 = Klep KOUD water = Summer - cold air = Eté - air froid = Sommer - kalte Luft = Verano - aire frio = Zomer - koude lucht = Inverno - aria calda = Winter - warm air = Hiver - air chaud = Winter - warme Luft = Invierno - aire caliente = Winter - warme lucht = External season mode switch-over EH = Electrical heater SA = Air probe TMM = TMM low temperature (cut-out thermostat) = Sonda di minima TME TME = TME low temperature (cut-out thermostat) = Sezionatore con un polo 1 = Circuit breakers protetto da fusibile with one pole protected (raccomandato) by fuse (recommended) TME M E E2 = VerdrahtungsMC = Borna de conexión Klemmenbrett de cableado MFC = Klemmenbrett Bornier MFC = Borna de conexión des FAN COIL du ventilo-convecteur del ventiloconvector M = Motorventilator Motoventilateur M = Motoventilador E = Wasserventil (Anlage Vanne à eau E = Válvula agua (sistema de mit zwei Rohren) (installation à 2 tubes) climatización a 2 tubos) % = Warmwasserventil oder % Vanne eau chaude = Válvula agua caliente ou résistance électrique Elektrischer Widerstand o resistencia eléctrica Vanne eau froide E2 = Kaltwasserventil E2 = Válvula agua fría = Bornier du câblage MFC = LEYENDA = Estate - aria fredda = Cambio stagionale esterno EH = Resistenza elettrica SA = Sonda aria TMM = Sonda di minima TMM = Wiring terminal board MFC = Fan coil terminal board M = Fan E = Water valve (two tube unit) % = Hot water valve or electrical heater E2 = Cold water valve LEGENDE = = = = = = Giallo/Verde Rosso = Minima Arancio = Media Nero = Massima Marrone Blu CH GNYE RD OG BK BN BU = = = = = = Yellow/Green Red = Low Orange = Medium Black = High Brown Dark blue CH = Changement de saison extérieur EH = Résistance électrique SA = Sonde air TMM = Sonde de température minimun TMM TME = Sonde de température minimun TME 1 = Interrupteur avec une pôle protégé par fusible (recommandé) GNYE = Juane/Vert RD = Rouge = Mini OG = Orange = Moyenne BK = Noir = Maxi BN = Marron BU = Bleu foncé CH = Externer Betriebsartenwechsel EH = Elektrischer Widerstand SA = Luftsonde TMM = Mindesettemperatursonde TMM TME = Mindesettemperatursonde TME 1 = Hauptschalter (empfohlen) GNYE RD OG BK BN BU = = = = = = Gelb/Groen Rot = Min Orange = Med Schwarz = Max Braun Blau CH = Externe seizoenomschakeling EH = Eelektrische weerstand SA = Luchtsonde TMM = Uitschakelthermostaat TMM Sonda TME de mínima TME = Uitschakelthermostaat TME = Polige schakelaar met Interruptor de maniobra 1 een zekering beveiligd seccionator de una polo (aanbevolen) protección con fusible (recomendado) GNYE = Geel/Groen Amarillo/Verde RD = Rood = Minima Rojo = Mínima OG = Oranje = Media Naranja = Media BK = Zwart = Massima Negro = Máxima BN = Bruin Marrón BU = Donkerblauw Azul = Cambio externo de temporada EH = Resistencia eléctrica SA = Sonda de aire TMM = Sonda TMM de mínima TME = 1 = GNYE RD OG BK BN BU = = = = = = CH A s )MPIANTOSENZAVALVOLE s 4ERMOSTATAZIONE sul motore A s 7ITHOUTVALVESINSTALLATION s 4HERMOSTATICCONTROL on the fan A s )NSTALLATIONSANSVANNES s 4HERMOSTAT sur le ventilateur A s /HNEVENTILE3YSTEM s 4EMPERATURREGELUNG am Ventilator A s )NSTALACIØNSINVÈLVULAS s 4ERMOSTATACIØN sobre el ventilador A s )NSTALLATIE:ONDERKLEPPEN s 4HERMOSTATISCHE regeling ventilator B s )MPIANTOTUBI (1 valvola) s 4ERMOSTATAZIONE sulla valvola B s TUBEINSTALLATION (1 valve) s 4HERMOSTATICCONTROL on the valve B s )NSTALLATIONËTUBES (1 vanne) s 4HERMOSTATATION sur le vanne B s ,EITER3YSTEM (1 Ventil) s 4EMPERATURREGELUNG der Ventil B s )NSTALACIØNCONTUBOS (1 válvula) s 4ERMOSTATACIØN sobre la válvula B s )NSTALLATIEMETLEIDINGEN (1 klep) s 4HERMOSTATISCHE regeling klep C s )MPIANTOTUBI (2 valvole) s 4ERMOSTATAZIONE sulle valvole C s TUBEINSTALLATION (2 valves) s 4HERMOSTATICCONTROL on the valves C s )NSTALLATIONËTUBES (2 vannes) s 4HERMOSTATATION sur les vannes C s ,EITER3YSTEM (2 Ventilen) s 4EMPERATURREGELUNG der Ventile C s )NSTALACIØNCONTUBOS (2 válvulas) s 4ERMOSTATACIØN sobre las válvulas C s )NSTALLATIEMETLEIDINGEN (2 kleppen) s 4HERMOSTATISCHE regeling kleppen ! TYPE CODE MO-3V 9060160 MO-3V – Cod. 9060160 MO-3V – Code 9060160 MO-3V – Code 9060160 MO-3V – Art. Nr. 9060160 MO-3V – Cód. 9060160 MO-3V – Code 9060160 COMMUTAZIONE MANUALE DELLE 3 VELOCITÀ DEL VENTILATORE, SENZA CONTROLLO TERMOSTATICO MANUAL SELECTION OF 3 FAN SPEEDS WITHOUT THERMOSTATIC CONTROL COMMUTATION MANUELLE DES 3 VITESSES DU VENTILATEUR, SANS CONTRÔLE THERMOSTATIQUE MANUELLE UMSCHALTUNG DER DREI DREHZAHLSTUFEN DES VENTILATORS OHNE THERMOSTATSTEUERUNG CONMUTACIÓN MANUAL DE LAS 3 VELOCIDADES DEL VENTILADOR, SIN CONTROL TERMOSTÁTICO MANUELE OMSCHAKELING VAN DE 3 SNELHEDEN VAN DE VENTILATOR, ZONDER THERMOSTATISCHE REGELING - Togliere il coperchio del comando. - Remove the cover of the control unit. - Fissare la sua base sulla parete - Fix the base to the wall using anchors and screws. con l’ausilio di tasselli e viti. 230Vac 50Hz L N Q1 PE L - Collegare con fili isolati di sezio- - Connect the control unit terminals ne minima 0,75 mm2, i morsetti to the fan coil terminals, using del comando con quelli del Fan insulated wires with a minimum coil, rispettando lo schema qui cross section of 0.75 mm2 and respecting the wiring diagram raffigurato. alongside. - Alimentare il Fan coil con linea - Connect to a single phase 230V elettrica monofase (230V 50Hz) 50Hz power line, respecting the rispettando le posizioni della linea neutral (N) and line (L) positions (L), del neutro (N) e della messa and connecting the earth (PE). a terra (PE). 1 2 3 4 5 - Con l’interruttore (0-1) accende- - Turn on the control unit via the re il comando (posizione 1). O/I switch (position 4). BU N BU BU BK GNYE 6 7 8 9 10 11 12 13 14 GNYE M 230V 50Hz - Con il commutatore scegliere la - Use the selector to set the correct speed to obtain the performance velocità del ventilatore per otterequired. nere la prestazione desiderata. 4 5 - Verwijder het lid van de bediening. - Quitar la tapa del control. - Den Deckel der Steuerung abnehmen. - Die Unterseite mit Dübeln und - Asegurar su base en la pared - Bevestig de basis aan de muur met utilizando tornillos y tacos de Schrauben an der Wand befestigen. behulp van pluggen en schroeven. expansión. - Mit isolierten Leitern, Mindest- - Conectar, con hilos aislados que - Gebruik geïsoleerde draden met een querschnitt 0,75 mm2, die Klemmen tengan una sección como mínimo minimum doorsnede van 0,75 mm2 der Steuerung an jene des Fan de 0,75 mm2, los bornes del conom de klemmen van de bediening Coils anschließen; dabei den hier trol con los del fan coil, según el te verbinden met de klemmen van dargestellten Schaltplan beachten. esquema mostrado al lado. de ventilator-convector, volgens het weergegeven schema. - Die Stromzufuhr zum Fan Coil - Alimentar el fan coil con red eléc- - Voed de ventilator-convector met einschalten: Stromversorgung trica monofásica (230V 50Hz) een eenfasige elektrische lijn einphasig (230 V, 50 Hz) unter respetando las posiciones de la (230V~50Hz), waarbij u let op de Beachtung der Positionen des línea (L), del neutro (N) y de la neutrale (N) en lijnposities (L). Zorg Zuleiters (L), des Neutralleiters tevens voor een aardaansluiting toma de tierra (PE). (N) und des Erdleiters (PE). (PE). - Die Steuerung mit dem Schalter - Con el interruptor (0-1) encen- - Met de schakelaar (0-1) zet u de (0-1) einschalten (Position 1). der el dispositivo de accionabediening aan (op stand 1). miento (posición 1). - Choisir la vitesse du ventilateur - Mit dem Umschalter die Drehzahl- - Con el conmutador elegir la velo- - Met de schakelaar kiest u de stufe des Ventilators wählen, um cidad del ventilador para conseà l’aide du commutateur pour gewenste snelheid voor de obtenir la performance souhaitée. die gewünschte Leistung zu guir la prestación deseada. ventilator, met het oog op de erhalten. gewenste prestaties. ." Questo comando non è adatto per il controllo di valvole acqua e non può ricevere il termostato di minima elettronico (TME), che può essere sostituito da un termostato di minima bimetallico (TMM), posto in contatto con la tubazione, che interromperà il filo di alimentazione (L) se l’acqua è inferiore a 30°C. &UNZIONEVALIDA PERILSOLOCICLOINVERNALE NB: This control is not suitable for controlling water valves and cannot be connected to the TME low temperature cut-out thermostat. This can be replaced by the TMM bimetal minimum thermostat which, placed in contact with the tubes, interrupts the live power line (L) if the water falls below a temperature of 30°C. 6ALIDONLY FORWINTERMODEOPERATION ." Cette commande n’est pas adaptée au contrôle de vannes à eau et ne peut pas recevoir le thermostat de température minimum électronique (TME), qui peut être remplacé par un thermostat de température minimale bimétallique (TMM), mis en contact avec la tuyauterie, qui interrompra le conducteur d’alimentation (L) si l’eau est inférieure à 30°C. &ONCTIONVALIDE UNIQUEMENTPOURLECYCLEHIVER ." Diese Steuerung ist nicht geeignet für die Kontrolle von Wasserventilen, die Aufnahme des elektronischen MindesttemperaturThermostats (TME), der durch einen Bimetall-Mindesttemperatur-Thermostat (TMM) ersetzt werden kann, der in Berührung mit der Rohrleitung installiert wird und den Zuleiter (L) unterbricht, wenn die Wassertemperatur unter 30°C liegt. Diese Funktion ist nur BEIM7INTERBETRIEBMÚGLICH NB: Este control no es apto para el control de válvulas del agua y no puede recibir la sonda electrónica de temperatura mínima (TME) que puede ser sustituida por una sonda bimetálica de temperatura mínima (TMM) colocada en contacto con la tubería y que cortará el hilo de alimentación (L) si la temperatura del agua es inferior a 30°C. &UNCIØNVÈLIDA SØLOPARAELCICLOINVERNAL ." Deze bediening is niet geschikt voor de bediening van waterkleppen en is niet geschikt voor gebruik met een uitschakelthermostaat (TME), die kan worden vervangen door een bimetallieke thermostaat (TMM), die de voedingslijn (L) onderbreekt als de temperatuur van het water onder 30°C daalt. &UNCTIEALLEEN GELDIGVOORDEWINTERCYCLUS VARIANTE PER L’APPLICAZIONE DEL TERMOSTATO DI MINIMA TMM VARIANT FOR APPLICATION OF TMM LOW TEMPERATURE CUT-OUT THERMOSTAT VARIANTE POUR L’APPLICATION DU THERMOSTAT DE TEMPÉRATURE MINIMUM 4-- VARIANTE FÜR DIE ANBRINGUNG DES MINDESTTEMPERATURTHERMOSTATS TMM VARIANTE PARA LA APLICACIÓN DEL TERMOSTATO DE MÍNIMA 4-- VARIANTE VOOR DE TOEPASSING VAN DE UITSCHAKELTHERMOSTAAT TMM (adatto unicamente per funzionamento nel ciclo invernale di riscaldamento) (suitable for winter heating mode operation only) (adaptée uniquement au fonctionnement en cycle hiver de chauffage) (geeignet ausschließlich für den Heizbetrieb im Winter) (apto sólo para el funcionamiento en el ciclo invernal de calefacción) (enkel geschikt om te verwarmen in de wintercyclus) 6 BK N BU BK GNYE PE L TMM 15 BK 5 RD 4 BU BU BK GNYE N OG MFC PE L - Retirer le couvercle de la commande. - Fixer sa base à la paroi à l’aide de chevilles à expansion et de vis. - Raccorder, avec des conducteurs isolés d’une section minimale de 0,75 mm2, les bornes de la commande à celles du ventilo-convecteur, en respectant le schéma représenté ci-contre. - Alimenter le ventilo-convecteur avec une ligne électrique monophasée (230 V 50 Hz) en respectant les positions de la ligne (L), du neutre (N) et de la mise à la terre (PE). - Allumer la commande à l’aide de l’interrupteur (0 - 1), position 1. TMM ! TYPE CODE MO-3V + SEL-CVP 9060160 + 9025302 SENZAVALVOLEnWITHOUTVALVES SANSVANNESn/HNEVENTILE SINVÈLVULASn:ONDERKLEPPEN L N Q1 230Vac 50Hz MO-3V PE 1 2 3 4 5 L BK 4 5 6 7 8 9 10 11 12 13 M 230V 50Hz SNELHEIDSSCHAKELAAR ONTVANGER Aplicado en la structura de los fan coils permite controlar varios aparatos (como máximo 8) mediante la señal de un único mando a distancia. Gemonteerd op de structuur van de ventilatorconvectors, voor de bediening van meerdere apparaten (max 8) via een signaal afkomstig van één enkele afstandsbediening. 15 7 8 9 10 11 12 1 2 3 4 5 6 BN BU BK SELECTOR DE VELOCIDAD RECEPTOR OG MO-3V met SEL-CVP – Code 9025302 RD MO-3V con SEL-CVP – Cód 9025302 14 GNYE Diese Vorrichtung wird an der Struktur der Gebläsekonvektoren angebracht und gestattet die Steuerung meherer (max. 8) Geräte mit dem Signal einer einzigen Fernbedienung. N BK Appliqué sur la structure des ventilo-convecteurs, permet de contrôler plusieurs appareils (8 maxi) sur signal d’une seule commande à distance. RD DREHZAHLWÄHLSCHALTER EMPFÄNGER OG SELECTEUR DE VITESSE RECEPTEUR MFC PE L RD MO-3V with SEL-CVP – Art. Nr. 9025302 GNYE BK OG MO-3V avec SEL-CVP – Code 9025302 BU BU BU Fitted to the frame of the fan coil, this enables up to eight units to be cotrolled by the signal from a single remote control unit. BN Applicato sulla struttura dei ventilconvettori, consente il controllo di più apparecchi (Max 8) su segnale di un unico comando remoto. BU SPEED SELECTOR RECEIVER 7 8 9 10 11 12 BU SELETTORE DI VELOCITÀ RICEVENTE BK MO-3V with SEL-CVP – Code 9025302 GNYE MO-3V con SEL-CVP – Cod. 9025302 1 2 3 4 5 6 BU BU GNYE BK 7 8 9 10 M 230V 50Hz 20 11 12 13 14 20A GNYE 6 BK 5 OG 4 BU BU BK GNYE N RD MFC PE L 15 TYPE CODE CR-T 9066330 CR-T – Cod. 9066330 CR-T – Code 9066330 CR-T – Code 9066330 CR-T – Art. Nr. 9066330 CR-T – Cód. 9066330 CR-T – Code 9066330 COMANDO ELETTRICO CON TERMOSTATO ELETTRONICO ELECTRIC CONTROL UNIT WITH ELECTRONIC THERMOSTAT COMMANDE ELECTRIQUE AVEC THERMOSTAT ELECTRONIQUE ELEKTRISCHE STEUERUNG MIT ELEKTRONISCHEM THERMOSTAT CONTROL ELÉCTRICO CON TERMOSTATO ELECTRÓNICO ELEKTRISCHE BEDIENING MET ELEKTRONISCHE THERMOSTAAT - Idoneo per controllo termosta- - For the thermostatic control tico (ON-OFF) del ventilatore o (ON-OFF) of the fan or water della/e valvola/e acqua. valve(s). aria calda warm air air chaud warme luft aire caliente warme lucht aria fredda cold air air froid kalte luft aire frio koude lucht 230Vac 50Hz L N - Per una buona sensibilità della - To guarantee correct sensor sonda, il comando con termostasensitivity, the control unit with to deve essere posizionato sulla thermostat must be positioned at parete del locale da climatizzare, a height of about 1.5 metres on a all’altezza di circa 1,5 metri e lonwall of the room to be air conditioned, tano da fonti di calore e da coraway from heat sources and renti d’aria fredda. currents of cold air. MC1 1 2 3 4 5 6 7 8 1 2 MC2 Q1 PE L N BU BU GNYE BK 6 BU 7 8 9 10 11 12 13 230V 50Hz 230Vac 50Hz L N 15 GNYE M A 14 BK 5 OG 4 BU 1 2 MC2 Q1 PE L N GNYE BU BU 8 9 10 11 12 M 14 TMM 230V 50Hz + +TMM Den Deckel der Steuerung abnehmen und ihre Unterseite mit Dübeln und Schrauben an der Wand befestigen. Quitar la tapa del control y asegurar su base en la pared utilizando tornillos y tacos de expansión. Verwijder het lid van de bediening en bevestig de basis aan de muur met behulp van pluggen en schroeven. In relazione al tipo di impianto da eseguire, collegare, con fili isolati di sezione 0,75 mm2, i morsetti del comando con quelli del Fan coil seguendo le indicazioni riportate sugli schemi elettrici qui in calce, senza dimenticare di eseguire il collegamento dei ponticelli indicati sugli stessi. Depending on the type of installation, connect the control unit terminals to the fan coil terminals, using insulated wires with a minimum cross section of 0,75 mm2 and respecting the wiring diagram below. Remember to connect the jumpers. En fonction du type d’installation à réaliser, raccorder, avec des conducteurs isolés d’une section de 0,75 mm2, les bornes de la commande à celles du ventilo-convecteur en suivant les indications des schémas électriques ci-dessous, sans oublier d’effectuer le raccordement des cavaliers indiqués sur ces mêmes schémas. Je nach Art der Anlage, die realisiert werden soll, mit isolierten Leitern, Mindestquerschnitt 0,75 mm2, die Klemmen der Steuerung an jene des Fan Coils anschließen; dabei die Anleitungen der untenstehenden elektrischen Schaltpläne befolgen und nicht vergessen, die dort angegebenen Überbrückungen herzustellen. Según el tipo de instalación a realizar conectar, con hilos aislados que tengan una sección de 0,75 mm2, los bornes del control con los del fan coil, según las indicaciones presentadas en los esquemas eléctricos mostrados al lado, sin olvidarse de efectuar la conexión de los puentes indicados en dichos esquemas. Naargelang het uit te voeren type installatie, gebruik geïsoleerde draden met een minimum doorsnede van 0,75 mm2 om de klemmen van de bediening te verbinden met de klemmen van de ventilatorconvector, volgens de aanduidingen op de elektrische schakelingen hieronder, en let erop verbindingen te voorzien aangeduid op de schema’s. Alimentare il Fan coil con linea elettrica monofase (230V 50Hz) rispettando le posizioni: del neutro (N), della linea (L) e della messa a terra (PE). Connect the fan coil to a single phase 230V 50Hz power line, respecting the neutral (N) and line (L) positions and connecting the earth (PE). Alimenter le ventilo-convecteur avec une ligne électrique monophasée (230V 50Hz) en respectant les positions: du neutre (N), de la ligne (L) et de la mise à la terre (PE). Die Stromzufuhr zum Fan Coil einschalten: Stromversorgung einphasig (230V, 50Hz) unter Beachtung der Positionen des Neutralleiters (N), des Zuleiters (L) und des Erdleiters (PE). Alimentar el fan coil con red eléctrica monofásica (230V 50Hz) respetando las posiciones del neutro (N), de la línea (L) y de la toma de tierra (PE). Voed met een eenfasige lijn van 230V 50Hz, waarbij u let op de neutrale (N) en lijnposities (L). Zorg tevens voor een aardaansluiting (PE). 15 - Allumer la commande à l’aide de - Die Steuerung mit dem Schalter - Con el Interruptor (0-1) encen- - Met de SCHAKELAAR (0-1) zet u de l’interrupteur (0-1). (0-1) einschalten. der el control. bediening aan. - Choisir la saison de fonctionne- - Mit dem Wechselschalter die - Con el $ESVIADOR elegir el tipo - Met de WISSELSCHAKELAAR kiest ment à l’aide de l’INVERSEUR: Betriebsart wählen: de temporada: u de gewenste seizoenwerking: = riscaldamento = heating = chauffage = Heizung = calefacción = verwarming = raffrescamento = cooling = rafraîchissement = Kühlung = refrigeración = afkoeling - Con il Commutatore scegliere - Use the SELECTOR to set the la velocità. required speed. - Con la -ANOPOLADELTERMOSTATO set- - Use the THERMOSTATKNOB to select tare la temperatura ambiente desiderata. the required room temperature. - Choisir la vitesse à l’aide du - Mit dem Umschalter die Drehzahl- - Con el #ONMUTADOR elegir la - Met de OMSCHAKELAAR selecteert stufe wählen. u de snelheid. commutateur. velocidad. - Régler la température ambiante - Mit dem Drehknopf des Thermostats die - Con el -ANDODELTERMOSTATOregu- - Met de thermostaatknop stelt souhaitée avec le BOUTONDUTHERMOSTAT. gewünschte Raumtemperatur einstellen. lar la temperatura ambiente deseada. u de snelheid in. ." Questo comando può rice- NB: This control can be connected vere il termostato di minima elet- to the TMM electronic minimum thermostat. tronico TMM. ." Cette commande peut recevoir ." Diese Steuerung ist für die Aufnahme NB: Este control puede recibir el ." Deze bediening is geschikt le thermostat de température minimum des elektronischen Mindesttemperatur- termostato electrónico de mínima voor gebruik met elektronische électronique TMM. Thermostats (TMM) geeignet. TMM. uitschakelthermostaat TMM. 230Vac 50Hz L N 230Vac 50Hz L N MC1 1 2 3 4 5 6 7 8 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 Q1 PE L Q1 PE L N BU BU Q1 PE L N BU BU BK BU BU GNYE BK GNYE 11 12 13 14 M 5 BK 6 7 9 10 M E TMM 8 11 12 13 14 15 BU B + +TMM 7 N L PE MP 8 9 10 11 M N L PE C B1 ! + +TMM 12 13 14 16 17 15 E TMM 230V 50Hz E 230V 50Hz C BK 6 BK 4 BU 5 OG N 4 RD PE L 15 BK 14 RD 13 E GNYE M 12 15 230V 50Hz 230V 50Hz 11 OG 10 BU 9 BK RD 8 OG BU BU BK GNYE 7 N GNYE 10 6 PE L GNYE 9 5 GNYE GNYE 8 4 GNYE 7 N PE L BK 6 OG 5 RD 4 BU BU N MFC MFC GNYE MFC BK 1 2 MC2 N GNYE N BU BU GNYE 1 2 3 4 5 6 7 8 MFC Q1 PE L B MC1 MC1 MC2 PE L 1 2 MC2 MC2 230Vac 50Hz L N 230Vac 50Hz L N MC1 BU A 13 Retirer le couvercle de la commande et fixer sa base sur la paroi à l’aide de chevilles à expansion et de vis. GNYE 7 BK 6 OG 5 RD 4 BU BK GNYE N BU MFC PE L Remove the cover of the control unit and fix the base to the wall using anchors and screws. - Con l’Interruttore (0-1) accen- - Turn on the control via the O/I dere il comando. switch. - Con il $EVIATORE scegliere la sta- - Use the DEVIATOR to select the gione di esercizio: season operating mode: MC1 1 2 3 4 5 6 7 8 Togliere il coperchio del comando e fissare la sua base sulla parete con l’ausilio di tasselli e viti. GNYE GNYE BK GNYE N RD MFC PE L - Adaptée au contrôle thermostatique - Geeignet für die Thermostatsteuerung - Apto para el control termostático - Geschikt voor de thermostatische (ON-OFF) du ventilateur ou de la (ON-OFF) des elektrischen Ventilators (ON-OFF) del ventilador o de regeling (ON-OFF) van de ventilator ou des vannes à eau. oder des Wasserventils bzw. der van de waterklep(pen). la/las válvula/s del agua. Wasserventile. - Pour une bonne sensibilité de la - Für eine gute Ansprechempfindlich- - Para una buena sensibilidad de - Voor een correcte werking van de sonde, la commande avec thermostat keit der Sonde muss die Steuerung sonde, moet de bediening van de la sonda es preciso colocar el doit être placée sur la paroi du mit Thermostat an der Wand des control con termostato en la pared thermostaat geplaatst worden aan de local à climatiser, à une hauteur Raumes, der klimatisiert werden soll, del cuarto a climatizar, a una wand van het lokaal dat moet worden d’environ 1,5 m et loin de toute angebracht werden, und zwar in einer altura de aproximadamente 1,5 m verwarmd/afgekoeld, op een hoogte source de chaleur ou de courants Höhe von etwa 1,5 Meter und nicht in y lejos de fuentes de calor y de van circa 1,5 meter en verwijderd van d’air froid. der Nähe von Wärmequellen und Zugluft. warmtebronnen en koude luchtstromen. corrientes de aire frío. MP B1 16 17 TYPE CODE CR-T + SEL-CVP 9066330 + 9025302 SENZAVALVOLEnWITHOUTVALVES SANSVANNESn/HNEVENTILE SINVÈLVULASn:ONDERKLEPPEN L N Q1 CR-T 230Vac 50Hz MC1 PE 1 2 3 4 5 6 7 8 L N 1 2 MC2 Appliqué sur la structure des ventilo-convecteurs, permet de contrôler plusieurs appareils (8 maxi) sur signal d’une seule commande à distance. Diese Vorrichtung wird an der Struktur der Gebläsekonvektoren angebracht und gestattet die Steuerung meherer (max. 8) Geräte mit dem Signal einer einzigen Fernbedienung. GNYE MFC PE L N 4 5 6 BU 7 BK 8 9 10 11 12 13 14 15 GNYE DREHZAHLWÄHLSCHALTER EMPFÄNGER BK BK SELECTEUR DE VITESSE RECEPTEUR BU BU BU CR-T with SEL-CVP – Art. Nr. 9025302 GNYE CR-T avec SEL-CVP – Code 9025302 BK RD Fitted to the frame of the fan coil, this enables up to eight units to be cotrolled by the signal from a single remote control unit. OG Applicato sulla struttura dei ventilconvettori, consente il controllo di più apparecchi (Max 8) su segnale di un unico comando remoto. RD SPEED SELECTOR RECEIVER 7 8 9 10 11 12 OG SELETTORE DI VELOCITÀ RICEVENTE 1 2 3 4 5 6 BN CR-T with SEL-CVP – Code 9025302 BU CR-T con SEL-CVP – Cod. 9025302 M 230V 50Hz SNELHEIDSSCHAKELAAR ONTVANGER Aplicado en la structura de los fan coils permite controlar varios aparatos (como máximo 8) mediante la señal de un único mando a distancia. Gemonteerd op de structuur van de ventilatorconvectors, voor de bediening van meerdere apparaten (max 8) via een signaal afkomstig van één enkele afstandsbediening. 7 8 9 10 11 12 1 2 3 4 5 6 BN BU BK SELECTOR DE VELOCIDAD RECEPTOR OG CR-T met SEL-CVP – Code 9025302 RD CR-T con SEL-CVP – Cód 9025302 BK BU BU GNYE BK 7 8 9 10 11 12 13 M 230V 50Hz 22 14 GNYE BU 6 BK 5 OG 4 BU GNYE N RD MFC PE L 22A 15 TYPE CODE CR-T + SEL-CVP 9066330 + 9025302 CONVALVOLAnWITHVALVE AVECVANNEnMIT6ENTIL CONVÈLVULAnMETKLEP L N 9066330 + 9025302 Q1 MC1 PE CR-T + SEL-CVP CONVALVOLAEPOMPAnWITHVALVEANDPUMP AVECVANNEETPOMPEnMIT6ENTILUNDPOMPE CONVÈLVULAYBOMBAnMETKLEPENPOMP L N CR-T 230Vac 50Hz CODE 1 2 3 4 5 6 7 8 L N 1 2 CR-T 230Vac 50Hz MC1 PE 1 2 3 4 5 6 7 8 BU GNYE BK OG RD BN BK OG RD BN BU 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 BU BU BU BU GNYE BK MFC 13 14 PE L 15 M N 4 5 6 BU 7 BK 12 13 14 15 E MP B1 7 8 9 10 11 12 BN BU GNYE BU BU BK RD OG 1 2 3 4 5 6 BK OG 11 M 7 8 9 10 11 12 1 2 3 4 5 6 RD 10 230V 50Hz N L PE BN 9 E 230V 50Hz BU 8 GNYE 12 BK 11 RD 10 BU 9 GNYE BK 8 GNYE GNYE BU 7 BK 6 RD 5 OG 4 BU GNYE N OG MFC PE L BU BU GNYE BK MFC 12 13 14 M 15 PE L N 4 5 BU BK 6 7 8 9 10 11 12 13 M E E 230V 50Hz 230V 50Hz N L PE 23 14 GNYE 11 BK 10 OG 9 BU 8 GNYE BK 7 BK BU 6 OG 5 RD 4 BU GNYE N RD MFC PE L L N 1 2 MC2 MC2 1 2 3 4 5 6 GNYE GNYE Q1 TYPE MP B1 23A 15 TYPE CODE TMO-T 9060161 aria calda warm air air chaud warme luft aire caliente warme lucht aria fredda cold air air froid kalte luft aire frio koude lucht TME 230Vac 50Hz L N 1 2 3 4 5 6 7 8 1 2 BU BU BK TMO-T – Code 9060161 CONTROL ELÉCTRICO CON TERMOSTATO ELECTRÓNICO ELEKTRISCHE BEDIENING MET ELEKTRONISCHE THERMOSTAAT - Pour une bonne sensibilité de la - Für eine gute Ansprechempfindlich- - Para una buena sensibilidad de - Voor een correcte werking van de sonde, la commande avec thermostat keit der Sonde muss die Steuerung sonde, moet de bediening van de la sonda es preciso colocar el doit être placée sur la paroi du mit Thermostat an der Wand des control con termostato en la pared thermostaat geplaatst worden aan local à climatiser, à une hauteur Raumes, der klimatisiert werden del cuarto a climatizar, a una de wand van het lokaal dat moet d’environ 1,5 m et loin de toute soll, angebracht werden, und zwar altura de aproximadamente 1,5 m worden verwarmd/afgekoeld, op source de chaleur ou de courants in einer Höhe von etwa 1,5 Meter y lejos de fuentes de calor y de een hoogte van circa 1,5 meter d’air froid. und nicht in der Nähe von Wärmecorrientes de aire frío. en verwijderd van warmtebronnen quellen und Zugluft. en koude luchtstromen. 1 2 L (230Vac) BU 7 8 9 10 11 12 13 14 15 GNYE M A 230V 50Hz Togliere il coperchio del comando e fissare la sua base sulla parete con l’ausilio di tasselli e viti. Remove the cover of the control unit and fix the base to the wall using anchors and screws. Retirer le couvercle de la commande et fixer sa base sur la paroi à l’aide de chevilles à expansion et de vis. Den Deckel der Steuerung abnehmen und ihre Unterseite mit Dübeln und Schrauben an der Wand befestigen. Quitar la tapa del control y asegurar su base en la pared utilizando tornillos y tacos de expansión. Verwijder het lid van de bediening en bevestig de basis aan de muur met behulp van pluggen en schroeven. In relazione al tipo di impianto da eseguire, collegare, con fili isolati di sezione 0,75 mm2, i morsetti del comando con quelli del Fan coil seguendo le indicazioni riportate sugli schemi elettrici qui in calce, senza dimenticare di eseguire il collegamento dei ponticelli indicati sugli stessi. Depending on the type of installation, connect the control unit terminals to the fan coil terminals, using insulated wires with a minimum cross section of 0,75 mm2 and respecting the wiring diagram below. Remember to connect the jumpers. En fonction du type d’installation à réaliser, raccorder, avec des conducteurs isolés d’une section de 0,75 mm2, les bornes de la commande à celles du ventilo-convecteur en suivant les indications des schémas électriques ci-dessous, sans oublier d’effectuer le raccordement des cavaliers indiqués sur ces mêmes schémas. Je nach Art der Anlage, die realisiert werden soll, mit isolierten Leitern, Mindestquerschnitt 0,75 mm2, die Klemmen der Steuerung an jene des Fan Coils anschließen; dabei die Anleitungen der untenstehenden elektrischen Schaltpläne befolgen und nicht vergessen, die dort angegebenen Überbrückungen herzustellen. Según el tipo de instalación a realizar conectar, con hilos aislados que tengan una sección de 0,75 mm2, los bornes del control con los del fan coil, según las indicaciones presentadas en los esquemas eléctricos mostrados al lado, sin olvidarse de efectuar la conexión de los puentes indicados en dichos esquemas. Naargelang het uit te voeren type installatie, gebruik geïsoleerde draden met een minimum doorsnede van 0,75 mm2 om de klemmen van de bediening te verbinden met de klemmen van de ventilatorconvector, volgens de aanduidingen op de elektrische schakelingen hieronder, en let erop verbindingen te voorzien aangeduid op de schema’s. Alimentare il Fan coil con linea elettrica monofase (230V 50Hz) rispettando le posizioni: del neutro (N), della linea (L) e della messa a terra (PE). Connect the fan coil to a single phase 230V 50Hz power line, respecting the neutral (N) and line (L) positions and connecting the earth (PE). Alimenter le ventilo-convecteur avec une ligne électrique monophasée (230V 50Hz) en respectant les positions: du neutre (N), de la ligne (L) et de la mise à la terre (PE). Die Stromzufuhr zum Fan Coil einschalten: Stromversorgung einphasig (230V, 50Hz) unter Beachtung der Positionen des Neutralleiters (N), des Zuleiters (L) und des Erdleiters (PE). Alimentar el fan coil con red eléctrica monofásica (230V 50Hz) respetando las posiciones del neutro (N), de la línea (L) y de la toma de tierra (PE). Voed met een eenfasige lijn van 230V 50Hz, waarbij u let op de neutrale (N) en lijnposities (L). Zorg tevens voor een aardaansluiting (PE). GNYE BK 6 RD 5 OG 4 BU BK TMO-T – Cód. 9060161 - Per una buona sensibilità della - To guarantee correct sensor sensitivity, the control unit with sonda, il comando con termostato deve essere posizionato sulla thermostat must be positioned at parete del locale da climatizzare, a height of about 1.5 metres on a all’altezza di circa 1,5 metri e lonwall of the room to be air conditioned, tano da fonti di calore e da coraway from heat sources and renti d’aria fredda. currents of cold air. MFC GNYE TMO-T – Art. Nr. 9060161 ELEKTRISCHE STEUERUNG MIT ELEKTRONISCHEM THERMOSTAT - Adaptée au contrôle thermostatique - Geeignet für die Thermostatsteuerung - Apto para el control termostático - Geschikt voor de thermostatische (ON-OFF) du ventilateur ou de la (ON-OFF) des elektrischen Ventilators (ON-OFF) del ventilador o de regeling (ON-OFF) van de ventilator ou des vannes à eau. oder des Wasserventils bzw. der van de waterklep(pen). la/las válvula/s del agua. Wasserventile. N N TMO-T – Code 9060161 COMMANDE ELECTRIQUE AVEC THERMOSTAT ELECTRONIQUE - Idoneo per controllo termosta- - For the thermostatic control tico (ON-OFF) del ventilatore o (ON-OFF) of the fan or water della/e valvola/e acqua. valve(s). MC3 CH PE L TMO-T – Code 9060161 ELECTRIC CONTROL UNIT WITH ELECTRONIC THERMOSTAT MC1 MC2 Q1 PE L TMO-T – Cod. 9060161 COMANDO ELETTRICO CON TERMOSTATO ELETTRONICO TME 230Vac 50Hz L N MC1 1 2 3 4 5 6 7 8 1 2 1 2 MC2 MC3 CH Q1 PE L L (230Vac) N BU BU GNYE 6 BU 7 8 9 10 11 M 13 14 15 E GNYE B 12 BK 5 RD 4 BU BK GNYE N OG MFC PE L 230V 50Hz TME 230Vac 50Hz L N MC1 1 2 3 4 5 6 7 8 1 2 MC2 1 2 MC3 CH Q1 PE L BK 9 10 M 12 E 230V 50Hz C 11 13 14 GNYE 8 BK BK 7 OG BU 6 RD 5 BU GNYE GNYE 4 N L PE MP B1 15 = riscaldamento = heating = chauffage = Heizung = calefacción = verwarming = raffrescamento = cooling = rafraîchissement = Kühlung = refrigeración = afkoeling - Choisir la vitesse à l’aide du - Mit dem Umschalter die Drehzahl- - Con el #ONMUTADOR elegir la - Met de OMSCHAKELAAR selecteert stufe wählen. u de snelheid. commutateur. velocidad. - Régler la température ambiante - Mit dem Drehknopf des Thermostats - Con el -ANDO DEL TERMOSTATO - Met de thermostaatknop stelt souhaitée avec le BOUTON DU die gewünschte Raumtemperatur regular la temperatura ambiente u de snelheid in. thermostat. einstellen. deseada. ." Questo comando può rice- NB: This control can be connected vere il termostato di minima elet- to the TME electronic minimum tronico TME (MC 3). thermostat (MC 3). ." Cette commande peut recevoir ." Diese Steuerung ist für die Aufnahme NB: Este control puede recibir el ." Deze bediening is geschikt le thermostat de température minimum des elektronischen Mindesttemperatur- termostato electrónico de mínima voor gebruik met elektronische électronique TME (MC 3). Thermostats (TME) geeignet (MC 3). TME (MC 3). uitschakelthermostaat TME (MC 3). L (230Vac) COMMUTAZIONE %34!4%).6%2./ GNYE MFC N - Allumer la commande à l’aide de - Die Steuerung mit dem Schalter - Con el Interruptor (0-1) encen- - Met de SCHAKELAAR (0-1) zet u de l’interrupteur (0-1). (0-1) einschalten. der el control. bediening aan. - Choisir la saison de fonctionne- - Mit dem Wechselschalter die - Con el $ESVIADOR elegir el tipo - Met de WISSELSCHAKELAAR kiest ment à l’aide de l’INVERSEUR: Betriebsart wählen: de temporada: u de gewenste seizoenwerking: - Con il Commutatore scegliere - Use the SELECTOR to set the la velocità. required speed. - Con la -ANOPOLADELTERMOSTATO - Use the THERMOSTATKNOB to select settare la temperatura ambiente the required room temperature. desiderata. N BU BU PE L - Con l’Interruttore (0-1) accen- - Turn on the control via the O/I dere il comando. switch. - Con il $EVIATORE scegliere la sta- - Use the DEVIATOR to select the gione di esercizio: season operating mode: 35--%27).4%2 SWITCHING - Possibilità di selezionare il ciclo - Selecting the summer or winter di funzionamento estivo o inveroperating cycle directly from the nale direttamente dalla pulsancontrol keypad, via an electric tiera del comando, oppure, con signal from the heating plant, or un segnale elettrico, dalla cenautomatically using a CHANGEOVER in two-pipe systems, based trale termica o, negli impianti a due tubi, in modo automatico traon the setting selected by a Jumper (J1) inside the control mite un CHANGE-OVER in base unit. alla impostazione selezionata di un Jumper (J1) interno al comando. 24 COMMUTATION ²4²()6%2 3/--%27).4%2 OMSCHAKELING CONMUTACIÓN 6%2!./).6)%2./ OMSCHAKELING :/-%27).4%2 - Possibilité de sélectionner le cycle - Möglichkeit des Einstellens von - Posibilidad de seleccionar el - Mogelijkheid van cyclusselectie de fonctionnement été ou hiver Sommer- oder Winterbetrieb direkt ciclo de funcionamiento verano van zomer- of winterfunctie d.m.v. directement à partir du tableau an der Schalttafel oder, über ein o invierno directamente desde het knopbord op de bediening, de commande, ou, avec un signal elektrisches Signal, an der Heizung, el teclado del mando, o bien, con ofwel met een elektrisch signaal, électrique, à partir de la centrale oder, bei 2-Leiter- Systemen, una señal eléctrica, de la central uit de thermische centrale of in thermique ou, dans les installations térmica o, en las instalaciones de installatie met twee leidingen, automatisch mittels CHANGEà deux tubes, de façon automatique con dos tubos, de forma autoin automatisch d.m.v. een CHANGEOVER, auf Grundlage der Einmática mediante un CHANGEpar un inverseur CHANGE-OVER stellung eines in der Steuerung OVER volgens de ingestelde selon la configuration sélectionnée befindlichen Jumpers (J1). OVER en base a la programación selectie van een interne Jumper d’un Jumper (J1) à l’intérieur de seleccionada por un Jumper (J1) (J1). la commande. situado dentro del mando. 24A TYPE CODE TMO-T + SEL-CVP 9060161 + 9025302 SENZAVALVOLEnWITHOUTVALVES SANSVANNESn/HNEVENTILE SINVÈLVULASn:ONDERKLEPPEN L N Q1 TMO-T 230Vac 50Hz TME MC1 PE 1 2 3 4 5 6 7 8 L N 1 2 1 2 MC2 SELECTEUR DE VITESSE RECEPTEUR DREHZAHLWÄHLSCHALTER EMPFÄNGER Appliqué sur la structure des ventilo-convecteurs, permet de contrôler plusieurs appareils (8 maxi) sur signal d’une seule commande à distance. Diese Vorrichtung wird an der Struktur der Gebläsekonvektoren angebracht und gestattet die Steuerung meherer (max. 8) Geräte mit dem Signal einer einzigen Fernbedienung. BK TMO-T with SEL-CVP – Art. Nr. 9025302 CH BU BU GNYE BK MFC N 4 5 6 BU 7 BU BK 8 9 10 11 12 13 14 15 GNYE GNYE PE L BK TMO-T avec SEL-CVP – Code 9025302 RD Fitted to the frame of the fan coil, this enables up to eight units to be cotrolled by the signal from a single remote control unit. OG Applicato sulla struttura dei ventilconvettori, consente il controllo di più apparecchi (Max 8) su segnale di un unico comando remoto. RD SPEED SELECTOR RECEIVER OG SELETTORE DI VELOCITÀ RICEVENTE BN TMO-T with SEL-CVP – Code 9025302 7 8 9 10 11 12 BU TMO-T con SEL-CVP – Cod. 9025302 1 2 3 4 5 6 M 230V 50Hz SNELHEIDSSCHAKELAAR ONTVANGER Aplicado en la structura de los fan coils permite controlar varios aparatos (como máximo 8) mediante la señal de un único mando a distancia. Gemonteerd op de structuur van de ventilatorconvectors, voor de bediening van meerdere apparaten (max 8) via een signaal afkomstig van één enkele afstandsbediening. 7 8 9 10 11 12 1 2 3 4 5 6 BN BU BK SELECTOR DE VELOCIDAD RECEPTOR OG TMO-T met SEL-CVP – Code 9025302 RD TMO-T con SEL-CVP – Cód 9025302 GNYE BK BU BU BK 7 8 9 10 11 12 13 14 GNYE BU 6 BK 5 OG 4 BU GNYE N RD MFC PE L M 230V 50Hz 25 25A 15 MC3 L (230Vac) TYPE CODE TMO-T + SEL-CVP 9060161 + 9025302 CONVALVOLAnWITHVALVE AVECVANNEnMIT6ENTIL CONVÈLVULAnMETKLEP TYPE CODE TMO-T + SEL-CVP 9060161 + 9025302 L N L N 1 2 3 4 5 6 7 8 L N 1 2 1 2 MC2 1 2 3 4 5 6 1 2 3 4 5 6 7 8 7 8 9 10 11 12 1 2 3 4 5 6 L (230Vac) BN BK GNYE BU BU BU BU GNYE BK MFC PE L 15 M N 4 5 6 BU 7 BK MP 15 B1 12 13 14 BK BU BU GNYE BK 15 E BU BK 6 7 8 9 10 11 12 13 14 BK 5 OG 4 BU N RD MFC PE L GNYE M OG RD BU BN OG 11 GNYE RD 10 BK 9 BU BK 8 14 BK OG RD BN BU GNYE BU 7 13 7 8 9 10 11 12 GNYE BU BU 6 12 E 1 2 3 4 5 6 MFC 5 11 M 7 8 9 10 11 12 1 2 3 4 5 6 4 10 230V 50Hz N L PE N 9 E 230V 50Hz PE L 8 GNYE 14 13 BK 12 RD 11 OG 10 BU 9 GNYE BK 8 GNYE GNYE BU 7 BK 6 RD 5 OG 4 BU GNYE N 230V 50Hz M E 230V 50Hz N L PE 26 N 1 2 1 2 CH MFC PE L L MC2 MC3 RD CH TME MC1 PE BU BU BN RD OG 7 8 9 10 11 12 TMO-T 230Vac 50Hz BK MC1 PE Q1 TME OG TMO-T 230Vac 50Hz GNYE GNYE Q1 CONVALVOLAEPOMPAnWITHVALVEANDPUMP AVECVANNEETPOMPEnMIT6ENTILUNDPOMPE CONVÈLVULAYBOMBAnMETKLEPENPOMP MP B1 26A 15 MC3 L (230Vac) TMO-T-AU TMO-T-AU TMO-T-AU TMO-T-AU TMO-T-AU TYPE CODE Cod. 9060164 Code 9060164 Code 9060164 Art. Nr. 9060164 Cód. 9060164 Code 9060164 TMO-T-AU 9060164 COMANDO ELETTRICO CON TERMOSTATO ELETTRONICO ELECTRIC CONTROL UNIT WITH ELECTRONIC THERMOSTAT COMMANDE ELECTRIQUE AVEC THERMOSTAT ELECTRONIQUE ELEKTRISCHE STEUERUNG MIT ELEKTRONISCHEM THERMOSTAT CONTROL ELÉCTRICO CON TERMOSTATO ELECTRÓNICO ELEKTRISCHE BEDIENING MET ELEKTRONISCHE THERMOSTAAT Dopo aver scelto le funzioni desiderate, montare il comando a parete facendo attenzione a posizionarlo sulla parete del locale da condizionare all’altezza di circa 1,5 m, su una parete intermedia e lontano da fonti di calore e da correnti d’aria fredda; collegare la morsettiera M1-M2 posta sulla scheda elettronica alla morsettiera posta sulla fiancata del ventilconvettore secondo lo schema selezionato e nel rispetto degli schemi elettrici. Per il collegamento tra termostato e ventilconvettore utilizzare cavi con sezione minima 0,75 mm2. After choosing the required functions, mount the control unit to the wall, taking care to position it on an inner wall in the room being air-conditioned at a height of about 1.5 m, away from sources of heat and currents of cold air. Connect terminal board M1-M2 on the electronic board to the terminal board located on the side of the fan coil, according to the selected layout and following the wiring diagrams. For the connection between the thermostat and the fan coil, use cables with a minimum cross-section of 0.75 mm2. Après avoir choisi les fonctions voulues, monter la commande murale en veillant à la placer sur le mur du local à conditionner à une hauteur de 1,5 m environ, sur une cloison et loin de sources de chaleur et de courants d’air froid; connecter le bornier M1-M2 placé sur la carte électronique au bornier placé sur le flanc du ventilo-convecteur selon le schéma sélectionné et en respectant les schémas électriques. Pour la connexion entre thermostat et ventilo-convecteur utiliser des câbles de section minimum 0,75 mm2. Nachdem die gewünschten Funktionen eingestellt wurden, das Steuergerät an einer Innenwand in einer Höhe von zirka 1,5 m und fern von Wärmequellen und Kaltluftströmen montieren; die Klemmleiste M1-M2 an der Elektronikplatine gemäß des gewählten Schemas und unter Einhaltung der Schaltpläne mit der Klemmleiste an der Seite des Lüftungskonvektors verbinden. Für die Verbindung zwischen Thermostat und Lüftungskonvektor Drähte mit einem Querschnitt von min. 0,75 mm2 benutzen. Después de haber elegido las funciones deseadas, montar el mando de pared poniendo atención en colocarlo en la pared del local a acondicionar a una altura de 1,5 m aproximadamente, en un tabique y lejos de las fuentes de calor y de las corrientes de aire frío; conectar la caja de bornes M1-M2 situada sobre la tarjeta electrónica a la caja de bornes situada en el lado del ventilador convector según el esquema seleccionado y respetando los esquemas eléctricos. Para la conexión entre el termostato y el ventilador convector usar cables con una sección mínim de 0,75 mm2. Na de functies te hebben gekozen, de bediening aan de muur bevestigen. Er aandacht aan besteden dat hij gemonteerd wordt op de wand van het lokaal, dat moet verwarmd/ afgekoeld worden, op een hoogte van circa 1,5 meter en ver van warmtebronnen en koude luchtstromingen; het klemmenbord M1-M2 op de gedrukte schakelingen verbinden met het klemmenbord op de zijkant van de ventilatorconvector volgens het gekozen schema en de elektrische schema’s. Voor de verbinding tussen de thermostaat en de ventilatorconvector, kabels gebruiken met een minimumdoorsnede van 0,75 mm2. aria calda warm air air chaud warme luft aire caliente warme lucht aria fredda cold air air froid kalte luft aire frio koude lucht TME 230Vac 50Hz L N MC1 1 2 3 4 5 6 1 2 1 2 MC2 MC3 CH Q1 PE L L (230Vac) N BU BU GNYE BK 6 BU 7 8 9 10 11 12 13 La eventuale sonda di minima ac- Any TME minimum water probe qua TME deve essere collegata must be connected to terminal board M3. alla morsettiera M3. 15 GNYE M A 14 BK 5 RD 4 BU BK GNYE N OG MFC PE L 230V 50Hz Il comando può gestire le seguenti funzioni: TME 230Vac 50Hz L N MC1 1 2 1 2 3 4 5 6 1 2 MC2 L (230Vac) 6 BU 7 8 9 10 11 M 13 14 15 E GNYE B 12 BK 5 OG 4 RD N BU BK GNYE Das Steuergerät kann die folgenden Funktionen verwalten: El mando puede gestionar las siguientes funciones: 230V 50Hz TME 230Vac 50Hz L N - Accensione e spegnimento del - Turning the fan coil on and off. ventilconvettore. - Mise en marche et arrêt du - Ein- und Ausschalten des Lüft- - Encendido y apagado del venti- - In- en uitschakeling van de ventilo-convecteur. ungskonvektors. lador convector. ventilatorconvector. - Impostazione della temperatura - Setting and reading the required ambiente desiderata (SET). room temperature (SET). - Programmation de la température - Einstellung der gewünschten - Introducción de la temperatura - Instelling van de gewenste kamerambiante voulue (SET). temperatuur (SET). Raumtemperatur (SET). ambiente deseada (SET). - Selezione manuale delle tre ve- - Manual selection of the three locità del ventilatore. fan speeds. - Sélection manuelle des trois - Manuelle Einstellung der drei - Selección manual de las tres - Manuele selectie van de drie vitesses du ventilateur. versnellingen van de ventilator. Ventilatordrehzahlen. velocidades del ventilador. - Selezione automatica delle tre - Automatic selection of the three velocità del ventilatore in funziofan speeds according to the difference between the set ne dello scostamento esistente fra la temperatura impostata cotemperature and the room temperature. me set e quella ambiente. - Sélection automatique des trois - Automatische Einstellung der drei - Selección automática de las tres - Automatische selectie van de drie vitesses du ventilateur en fonction Ventilatordrehzahlen entsprechend velocidades del ventilador en versnellingen van de ventilator de l’écart existant entre la tempéder Abweichung zwischen einfunción de la diferencia existente in functie van de deviatie tussen rature programmée et la tempéentre la temperatura introducida de ingestelde temperatuur en gestellter Set Temperatur und de kamertemperatuur. rature ambiante. der effektiven Raumtemperatur. como set y la temperatura ambiente. - Comando termostatico di aper- - In both summer and winter cycle, tura o chiusura (ON-OFF), sia nel thermostatic control of opening ciclo estivo che in quello inverand closing (ON/OFF) of the water nale, della valvola acqua (impianvalve (two-pipe installation) or the to a due tubi) o delle due valvole two valves (four-pipe installation). (impianto a quattro tubi). - Commande thermostatique d’ou- - Thermostatsteuerung des Wasser- - Mando termostático de abertura - Thermostatische regeling (ONverture ou de fermeture (ON-OFF), ventils (ON-OFF) bei 2-Leitero cierre (ON-OFF), tanto en el OFF), zowel in de zomer- als in en cycle été comme en cycle hiver, Systemen, oder der beiden Wasserciclo de verano como en el de de wintercyclus, van de waterklep de la vanne eau (installation à ventile bei 4-Leiter-Systemen in (installatie met 2 leidingen) of invierno, de la válvula de agua deux tubes) ou des deux vannes (instalación con dos tubos) o de van de twee kleppen (installatie Kühl- und Heizbetrieb. (installation à quatre tubes). las dos válvulas (instalación con met 4 leidingen). cuatro tubos). MC1 1 2 3 4 5 6 1 2 MC2 1 2 MC3 CH L (230Vac) N BU BU BK GNYE 7 8 9 10 11 12 13 14 15 GNYE BK 6 BK 5 OG 4 BU BU GNYE GNYE N RD MFC PE L M E 230V 50Hz C De bediening kan de volgende functies in werking stellen: GNYE MFC Q1 PE L La commande peut gérer les fonctions suivantes: N BU BU PE L Si on installe une sonde de tempé- Die eventuelle Mindesstandsonde La eventual sonda de mínima agua De eventuele elektronische waterrature minimale eau TME, elle doit TME wird an die Klemmleiste M3 TME se tiene que conectar a la sonde TME moet verbonden zijn être raccordée au bornier M3. angeschlossen. caja de bornes M3. met het klemmenbord M3. MC3 CH Q1 PE L The control unit can manage the following functions: TMO-T-AU N L PE MP B1 27 27A - Collegando la sonda di minima - In the winter cycle only, if a (accessorio TME posta tra le minimum sensor is connected alette della batteria di scambio (TME accessory located between termico), nel solo ciclo invernale, the fins of the heat exchange coil), il ventilatore entrerà in funzione the fan coil will start up only if the solamente se la temperatura delwater temperature rises above l’acqua è superiore a 42°C e ver42°C and shut down when water rà fermato quando quest’ultima temperature drops below 38°C. è inferiore a 38°C. COMMUTAZIONE %34!4%).6%2./ Commutazione estate/inverno locale Local summer/winter switching Sommer/Winterumschaltung in der bedienung Commutation été/hiver locale Conmutación Verano/Invierno local Plaatselijke zomer/winter-omschakeling 2-3 Commutazione estate/inverno remota Remote summer/winter switching Sommer/Winter Ferm-Umschaltung Commutation été/hiver à distance Conmutación verano/invierno remota Zomer/winter-omschakeling op afstand 35--%27).4%2 SWITCHING - Possibilità di selezionare il ciclo - Selecting the summer or winter di funzionamento estivo o inveroperating cycle directly from the nale direttamente dalla pulsancontrol keypad, via an electric tiera del comando, oppure, con signal from the heating plant, or un segnale elettrico, dalla cenautomatically using a CHANGEOVER in two-pipe systems, based trale termica o, negli impianti a due tubi, in modo automatico traon the setting selected by a mite un CHANGE-OVER in base Jumper (J1) inside the control alla impostazione selezionata unit. di un Jumper (J1) interno al comando. - En connectant la sonde de tem- - Durch Anschließen der Mindest- - Conectando la sonda de mínima - Door de elektronische waterpérature minimale (accessoire sonde (Zubehör TME zwischen (accesorio TME situado entre las sonde, enkel in de wintercyclus, TME placée entre les ailettes de den Lamellen des Wärmetauscheraletas de la batería de cambio te verbinden (accessoire TME térmico), en el ciclo invernal, el tussen de ribben van de reeks la batterie d’échange thermique), registers, wird der Ventilator nur en cycle hiver seulement, le veneingeschaltet, wenn die Wasserventilador entrará en función úniwarmtewisselaars geplaatst) wordt tilateur ne se mettra en marche temperatur über 42°C beträgt, camente si la temperatura del de ventilator enkel ingeschakeld agua es superior a 42°C y se que si la température de l’eau est und ausgeschaltet, wenn sie bis indien de temperatuur van het cerrará cuando esta última sea supérieure à 42°C et s’arrêtera unter 38°C absinkt. water meer dan 42°C bereikt en inferior a 38°C. quand celle-ci est inférieure à zal uitgeschakeld worden wanneer 38°C. ze lager dan 38°C is. COMMUTATION ²4²()6%2 3/--%27).4%2 OMSCHAKELING CONMUTACIÓN 6%2!./).6)%2./ OMSCHAKELING :/-%27).4%2 - Possibilité de sélectionner le cycle - Möglichkeit des Einstellens von - Posibilidad de seleccionar el - Mogelijkheid van cyclusselectie de fonctionnement été ou hiver Sommer- oder Winterbetrieb direkt ciclo de funcionamiento verano van zomer- of winterfunctie d.m.v. directement à partir du tableau an der Schalttafel oder, über ein o invierno directamente desde het knopbord op de bediening, de commande, ou, avec un signal elektrisches Signal, an der Heizung, el teclado del mando, o bien, con ofwel met een elektrisch signaal, électrique, à partir de la centrale oder, bei 2-Leiter- Systemen, una señal eléctrica, de la central uit de thermische centrale of in thermique ou, dans les installations térmica o, en las instalaciones de installatie met twee leidingen, automatisch mittels CHANGEcon dos tubos, de forma autoà deux tubes, de façon automatique OVER, auf Grundlage der Einin automatisch d.m.v. een CHANGEpar un inverseur CHANGE-OVER stellung eines in der Steuerung mática mediante un CHANGEOVER volgens de ingestelde selon la configuration sélectionnée befindlichen Jumpers (J1). OVER en base a la programación selectie van een interne Jumper d’un Jumper (J1) à l’intérieur de seleccionada por un Jumper (J1) (J1). la commande. situado dentro del mando. &UNZIONIIMPOSTABILIAMEZZO Dip Switch &UNCTIONSCANBESETUSING THEDIPSWITCHES &ONCTIONSPROGRAMMABLES ËLAIDEDU$IPSWITCH ÃBER$IP3WITCHEINSTELLBARE Funktionen &UNCIONESPROGRAMABLES AMEDIO$IP3WITCH &UNCTIESDIEDOOREEN DIMSCHAKELAARKUNNENWORDEN INGESTELD $)0 DIP 2 ON ON Termostatazione sul ventilatore Thermostatic control on the fan Thermostat sur le ventilateur Temperaturregelung am Ventilator Termostatación sobre el ventilador Thermostatische regeling ventilator ON OFF Termostatazione contemporanea delle valvole e del ventilatore Simultaneous thermostatic control on the valves and fan Thermostatation simultanée des vannes et du ventilateur Gleichzeitige Temperaturregelung der Ventile und des Ventilators Termostatación de las válvulas y los ventiladores al mismo tiempo Gelijktijdige thermostatische regeling kleppen en ventilator OFF ON Termostatazione sulle valvole e funzionamento continuo del ventilatore Thermostatic control on the valves and continuous fan operation Thermostatation sur les vannes et fonctionnement continu du ventilateur Temperaturregelung der Ventile und Dauerbetrieb des Ventilators Termostatación sobre las válvulas y funcionamiento contínuo del ventilador Thermostatische regeling kleppen en constante werking van de ventilator 28 28A TYPE CODE TMO-T-AU + SEL-CVP 9060164 + 9025302 SENZAVALVOLEnWITHOUTVALVES SANSVANNESn/HNEVENTILE SINVÈLVULASn:ONDERKLEPPEN L N Q1 TME TMO-T-AU 230Vac 50Hz L MC1 PE 1 2 3 4 5 6 N 1 2 MC2 Fitted to the frame of the fan coil, this enables up to eight units to be cotrolled by the signal from a single remote control unit. TMO-T-AU avec SEL-CVP – Code 9025302 TMO-T-AU with SEL-CVP – Art. Nr. 9025302 SELECTEUR DE VITESSE RECEPTEUR DREHZAHLWÄHLSCHALTER EMPFÄNGER Appliqué sur la structure des ventilo-convecteurs, permet de contrôler plusieurs appareils (8 maxi) sur signal d’une seule commande à distance. Diese Vorrichtung wird an der Struktur der Gebläsekonvektoren angebracht und gestattet die Steuerung meherer (max. 8) Geräte mit dem Signal einer einzigen Fernbedienung. TMO-T-AU con SEL-CVP – Cód 9025302 TMO-T-AU met SEL-CVP – Code 9025302 SELECTOR DE VELOCIDAD RECEPTOR SNELHEIDSSCHAKELAAR ONTVANGER Aplicado en la structura de los fan coils permite controlar varios aparatos (como máximo 8) mediante la señal de un único mando a distancia. Gemonteerd op de structuur van de ventilatorconvectors, voor de bediening van meerdere apparaten (max 8) via een signaal afkomstig van één enkele afstandsbediening. CH BK Applicato sulla struttura dei ventilconvettori, consente il controllo di più apparecchi (Max 8) su segnale di un unico comando remoto. RD SPEED SELECTOR RECEIVER OG SELETTORE DI VELOCITÀ RICEVENTE BN TMO-T-AU with SEL-CVP – Code 9025302 7 8 9 10 11 12 BU TMO-T-AU con SEL-CVP – Cod. 9025302 1 2 3 4 5 6 BU BU GNYE BK 6 BU 7 9 10 11 12 13 14 15 GNYE BK 8 BK 5 RD 4 BU GNYE N OG MFC PE L M 230V 50Hz 7 8 9 10 11 12 BU BN BK RD OG 1 2 3 4 5 6 GNYE BK BU BU BK 7 8 9 10 11 12 13 M 230V 50Hz 29 14 GNYE BU 6 BK 5 OG 4 BU GNYE N RD MFC PE L 1 2 MC3 29A 15 L (230Vac) TYPE CODE TMO-T-AU + SEL-CVP 9060164 + 9025302 CONVALVOLAnWITHVALVE AVECVANNEnMIT6ENTIL CONVÈLVULAnMETKLEP TYPE CODE TMO-T-AU + SEL-CVP 9060164 + 9025302 L N L N TME 1 2 3 4 5 6 L N 1 2 1 2 MC2 1 2 3 4 5 6 MC1 1 2 3 4 5 6 MC3 7 8 9 10 11 12 1 2 3 4 5 6 L (230Vac) RD BN GNYE BU BU GNYE BK 14 MFC PE L 15 M N 4 5 6 BU 7 BK 12 13 14 15 E MP B1 7 8 9 10 11 12 BN BU GNYE BU BU BK RD OG 1 2 3 4 5 6 BK OG 11 M 7 8 9 10 11 12 1 2 3 4 5 6 RD 10 230V 50Hz N L PE BN 9 E 230V 50Hz BU 8 GNYE 13 BK 12 RD 11 OG 10 BU 9 GNYE BK 8 GNYE GNYE BU 7 BK 6 RD 5 OG 4 BU GNYE N BU BU GNYE BK MFC 12 13 14 M 15 PE L N 4 5 BU BK 6 7 8 9 10 11 12 13 M E 230V 50Hz E 230V 50Hz N L PE 30 14 GNYE 11 BK 10 OG 9 BU 8 GNYE BK 7 BK BU 6 OG 5 RD 4 BU GNYE N RD MFC PE L N 1 2 MP 1 2 MC3 CH MFC PE L L MC2 BK CH BU BU TME PE BU BU BN RD OG 7 8 9 10 11 12 TMO-T-AU 230Vac 50Hz BK MC1 PE Q1 OG TMO-T-AU 230Vac 50Hz GNYE GNYE Q1 CONVALVOLAEPOMPAnWITHVALVEANDPUMP AVECVANNEETPOMPEnMIT6ENTILUNDPOMPE CONVÈLVULAYBOMBAnMETKLEPENPOMP B1 30A 15 L (230Vac) T2T – Cod. 9060174 TYPE CODE T2T 9060174 230Vac 50Hz L N 8 9 10 11 12 13 230V 50Hz 230Vac 50Hz L N N 3 9 7 8 6 11 10 N BU BU GNYE 7 8 9 10 11 12 13 M 15 To guarantee correct sensor sensitivity, the control unit with thermostat must be positioned at a height of about 1.5 m on a wall of the room to be air conditioned, away from heat sources and currents of cold air. Pour une bonne sensibilité de la sonde, la commande avec thermostat doit être placée sur la paroi du local à climatiser, à une hauteur d’environ 1,5 m et loin de toute source de chaleur ou de courants d’air froid. Für eine gute Ansprechempfindlichkeit der Sonde muss die Steuerung mit Thermostat an der Wand des Raumes, der klimatisiert werden soll, angebracht werden, und zwar in einer Höhe von etwa 1,5 Meter und nicht in der Nähe von Wärmequellen und Zugluft. Para una buena sensibilidad de la sonda es preciso colocar el control con termostato en la pared del cuarto a climatizar, a una altura de aproximadamente 1,5 m y lejos de fuentes de calor y de corrientes de aire frío. Voor een correcte werking van de sonde, moet de bediening van de thermostaat worden geplaatst aan de wand van het lokaal dat moet worden verwarmd/ afgekoeld, op een hoogte van circa 1,5 meter en ver verwijderd van warmtebronnen en koude luchtstromen. Pour la connexion entre thermostat Für die Verbindung zwischen Thermostat Para la conexión entre el termostato et ventilo-convecteur utiliser des câ- und Lüftungskonvektor Drähte mit y el ventilador convector usar cables bles de section minimum 0,75 mm2. einem Querschnitt von min. 0,75 mm2 con una sección mínim de 0,75 mm2. benutzen. Voor de verbinding tussen de thermostaat en de ventilator-convector, gebruik draden met een minimale doorsnede van 0,75 mm2. Pas utilisable avec les répétiteurs. Nicht mit Mehrfach-Steuerrelais No utilizable con los repetidores. verwendbar. Niet toepasbaar met versterkers. Cannot be used with repeaters. La commande peut gérer les fonc- Das Steuergerät kann die folgenden El mando puede gestionar las si- De bediening kan de volgende functies beheren: tions suivantes: Funktionen verwalten: guientes funciones: - Accensione e spegnimento del - Turning the fan coil on and off. ventilconvettore. - Mise en marche et arrêt du ventilo- - Ein- und Ausschalten des Lüftungs- - Encendido y apagado del venti- - In- en uitschakelen van de ventilatorconvecteur. konvektors. convector. lador convector. - Impostazione della temperatura - Setting and reading the required room temperature (SET). ambiente desiderata (SET). - Programmation de la température - Einstellung der gewünschten Raum- - Introducción de la temperatura - Instelling van de gewenste omgevingsambiante voulue (SET). temperatur (SET). temperatuur (SET). ambiente deseada (SET). - Possibilità di selezionare il ciclo di - Selecting the summer or winter funzionamento estivo o invernale operating cycle directly from the direttamente dalla pulsantiera del control keypad. comando. - Possibilité de sélectionner le cycle - Möglichkeit des Einstellens von - Posibilidad de seleccionar el ciclo - De mogelijkheid de winter- of zomerde fonctionnement été ou hiver Sommer- oder Winterbetrieb direkt de funcionamiento verano o invierno cyclus te kiezen rechtstreeks met directement à partir du tableau de an der Schalttafel oder. directamente desde el teclado del de knoppen van de bediening of. commande. mando. - Selezione manuale delle tre velo- - Manual selection of the three fan cità del ventilatore. speeds. - Sélection manuelle des trois vites- - Manuelle Einstellung der drei ses du ventilateur. Ventilatordrehzahlen. - Termostatazione contemporanea - Simultaneous thermostatic control delle valvole e del ventilatore (C). on the valves and fan (C). - Thermostatation simultanée des - Gleichzeitige Temperaturregelung - Termostatación de las válvulas y los - Gelijktijdige thermostatische regeling vannes et du ventilateur (C). der Ventile und des Ventilators (C). ventiladores al mismo tiempo (C). kleppen en ventilator (C). - Termostatazione sulla valvola - Thermostatic control on the valve e funzionamento continuo del and continuous fan operation ventilatore (B). (B). - Thermostatation sur la vanne - Temperaturregelung der Ventil und - Termostatación sobre la válvula - Thermostatische regeling klep en et fonctionnement continu du Dauerbetrieb des Ventilators (B). y funcionamiento contínuo del continue werking ventilator (B). ventilateur (B). ventilador (B). Idoneo per il controllo termostatico For the thermostatic control (ON(ON-OFF) della valvola acqua. OFF) of water valve. Adaptée au contrôle thermostatique Geeignet für die Thermostatsteuerung Apto para el control termostático Geschikt voor de thermostatische (ON-OFF) de la vanne à eau. (ON-OFF) der Wasserventil. (ON-OFF) de la válvula del agua. regeling (ON-OFF) de waterklep. Q1 PE L N 9 10 11 12 13 14 BU BU 15 M E GNYE M 230V 50Hz GNYE 11 12 13 14 MFC PE L 15 N 4 5 BU BK 6 7 B + +MP N L PE MP 8 9 10 11 12 13 14 15 BK 10 RD 9 OG 8 BU 7 BK BK 6 RD 5 OG 4 BU M E E 230V 50Hz 230V 50Hz C BK GNYE 8 N GNYE GNYE 7 N BU GNYE GNYE PE L BK 6 OG 5 RD 4 BU BU N 3 9 7 8 6 11 10 MFC GNYE MFC BK BK N N - Selección manual de las tres velo- - Manuele selectie van drie snelheden cidades del ventilador. voor de ventilator. N 3 9 7 8 6 11 10 BU BU GNYE 230Vac 50Hz L N N 3 9 7 8 6 11 10 BU BU PE L ELEKTROMECHANISCHE THERMOSTAAT Il comando può gestire le seguenti The control unit can manage the following functions: funzioni: Q1 PE L Q1 PE L – Code 9060174 Per una buona sensibilità della sonda, il comando con termostato deve essere posizionato sulla parete del locale da climatizzare, all’altezza di circa 1,5 m e lontano da fonti di calore e da correnti d’aria fredda. 230Vac 50Hz L N 230Vac 50Hz L N T2T TERMOSTATO ELETTROMECCANICO GNYE E 230V 50Hz B 14 BK 6 OG 5 RD 4 BU BK N BU MFC PE L – Cód. 9060174 PANEL DE MANDOS CON TERMOSTATO ELECTRÓMECÁNICO GNYE GNYE Q1 PE L 15 GNYE M A 14 BK 7 RD 6 OG 5 BU 4 BU BK N T2T – Art. Nr. 9060174 GNYE MFC PE L T2T – Code 9060174 FERNBEDIENUNG MIT ELEKTRISCHOHEMECHANISCHEM THERMOSTAT N BK T2T PANNEAU DE COMMANDE AVEC THERMOSTAT ÉLECTROMÉCANIQUE Per il collegamento tra termostato For the connection between the e ventilconvettore utilizzare condut- thermostat and the fan coil, use cables tori con sezione minima 0,75 mm2. with a minimum cross-section of 0.75 mm2. N 3 9 7 8 6 11 10 BU BU GNYE – Code 9060174 CONTROL PANEL WITH ELECTROMECHANICAL THERMOSTAT Non utilizzabile con i ripetitori. Q1 PE L GNYE T2T B1 C + +MP N L PE MP B1 ! TMO-503-SV2 TMO-503-SV2 TMO-503-SV2 TMO-503-SV2 TMO-503-SV2 TYPE CODE Cod. 9060173 Code 9060173 Code 9060173 Art. Nr. 9060173 Cód. 9060173 Code 9060173 TMO-503-SV2 9060173 COMANDO ELETTRICO CON TERMOSTATO ELETTRONICO ELECTRIC CONTROL UNIT WITH ELECTRONIC THERMOSTAT COMMANDE ELECTRIQUE AVEC THERMOSTAT ELECTRONIQUE ELEKTRISCHE STEUERUNG MIT ELEKTRONISCHEM THERMOSTAT CONTROL ELÉCTRICO CON TERMOSTATO ELECTRÓNICO ELEKTRISCHE BEDIENING MET ELEKTRONISCHE THERMOSTAAT Dopo aver scelto le funzioni desiderate, montare il comando a parete facendo attenzione a posizionarlo sulla parete del locale da condizionare all’altezza di circa 1,5m, su una parete intermedia e lontano da fonti di calore e da correnti d’aria fredda; collegare la morsettiera posta sulla scheda elettronica alla morsettiera posta sulla fiancata del ventilconvettore secondo lo schema selezionato e nel rispetto degli schemi elettrici. After choosing the required functions, mount the control unit to the wall, taking care to position it on an inner wall in the room being air-conditioned at a height of about 1.5 m, away from sources of heat and currents of cold air. Connect terminal board on the electronic board to the terminal board located on the side of the fan coil, according to the selected layout and following the wiring diagrams. Après avoir choisi les fonctions voulues, monter la commande murale en veillant à la placer sur le mur du local à conditionner à une hauteur de 1,5 m environ, sur une cloison et loin de sources de chaleur et de courants d’air froid; connecter le bornier placé sur la carte électronique au bornier placé sur le flanc du ventilo-convecteur selon le schéma sélectionné et en respectant les schémas électriques. Nachdem die gewünschten Funktionen eingestellt wurden, das Steuergerät an einer Innenwand in einer Höhe von zirka 1,5 m und fern von Wärmequellen und Kaltluftströmen montieren; die Klemmleiste an der Elektronikplatine gemäß des gewählten Schemas und unter Einhaltung der Schaltpläne mit der Klemmleiste an der Seite des Lüftungskonvektors verbinden. Después de haber elegido las funciones deseadas, montar el mando de pared poniendo atención en colocarlo en la pared del local a acondicionar a una altura de 1,5 m aproximadamente, en un tabique y lejos de las fuentes de calor y de las corrientes de aire frío; conectar la caja de bornes situada sobre la tarjeta electrónica a la caja de bornes situada en el lado del ventilador convector según el esquema seleccionado y respetando los esquemas eléctricos. Na de keuze van de gewenste functies, wordt de bediening gemonteerd aan de muur. Voor een correcte werking, moet de bediening van de thermostaat worden geplaatst aan de wand van het lokaal dat moet worden verwarmd/ afgeloed, op een hoogte van circa 1,5 meter en ver verwijderd van warmtebronnen en koude luchtstromen; sluit het klemmenbord op de elektronische fiche aan op het klemmenbord op de zijkant van de ventilator-convector, overeenkomstig het geselecteerd schema en de schakelschema’s. Per il collegamento tra termostato For the connection between the e ventilconvettore utilizzare condut- thermostat and the fan coil, use cables tori con sezione minima 0,75 mm2. with a minimum cross-section of 0.75 mm2. Pour la connexion entre thermostat Für die Verbindung zwischen Thermostat Para la conexión entre el termostato et ventilo-convecteur utiliser des câ- und Lüftungskonvektor Drähte mit y el ventilador convector usar cables bles de section minimum 0,75 mm2. einem Querschnitt von min. 0,75 mm2 con una sección mínim de 0,75 mm2. benutzen. Voor de verbinding tussen de thermostaat en de ventilator-convector, gebruik draden met een minimale doorsnede van 0,75 mm2. Il comando può gestire le seguenti The control unit can manage the funzioni: following functions: La commande peut gérer les fonc- Das Steuergerät kann die folgenden El mando puede gestionar las si- De bediening kan de volgende tions suivantes: Funktionen verwalten: guientes funciones: functies beheren: - Accensione e spegnimento del - Turning the fan coil on and off. ventilconvettore. - Mise en marche et arrêt du ventilo- - Ein- und Ausschalten des Lüftungs- - Encendido y apagado del venti- - In- en uitschakelen van de ventilatorconvecteur. konvektors. convector. lador convector. - Impostazione della temperatura - Setting and reading the required ambiente desiderata (SET). room temperature (SET). - Programmation de la température - Einstellung der gewünschten Raum- - Introducción de la temperatura - Instelling van de gewenste omgevingsambiente deseada (SET). ambiante voulue (SET). temperatur (SET). temperatuur (SET). - Possibilità di selezionare il ciclo di - Selecting the summer or winter funzionamento estivo o invernale operating cycle directly from the direttamente dalla pulsantiera del control keypad. comando. - Possibilité de sélectionner le cycle - Möglichkeit des Einstellens von - Posibilidad de seleccionar el ciclo - De mogelijkheid de winter- of zomerde fonctionnement été ou hiver Sommer- oder Winterbetrieb direkt de funcionamiento verano o invierno cyclus te kiezen rechtstreeks met directement à partir du tableau de an der Schalttafel oder. directamente desde el teclado del de knoppen van de bediening of. commande. mando. - Selezione manuale delle tre velo- - Manual selection of the three fan cità del ventilatore. speeds. - Sélection manuelle des trois vites- - Manuelle Einstellung der drei Ventilatordrehzahlen. ses du ventilateur. - Selezione automatica delle tre ve- - Automatic selection of the three fan locità del ventilatore in funzione speeds according to the difference dello scostamento esistente fra la between the set temperature and temperatura impostata come set the room temperature. e quella ambiente. - Sélection automatique des trois - Automatische Einstellung der drei - Selección automática de las tres - Automatische selectie van de drie vitesses du ventilateur en fonction Ventilatordrehzahlen entsprechend velocidades del ventilador en fun- snelheden voor de ventilator, in de l’écart existant entre la tempé- der Abweichung zwischen eingestellter ción de la diferencia existente entre functie van het bestaand verschil rature programmée et la tempéra- Set Temperatur und der effektiven la temperatura introducida como set tussen de ingestelde temperatuur ture ambiante. Raumtemperatur. y la temperatura ambiente. (SET) en de omgevingstemperatuur. - Termostatazione contemporanea - Simultaneous thermostatic control della valvola e del ventilatore. on the valve and fan. - Thermostatation simultanée de - Gleichzeitige Temperaturregelung - Termostatación de la válvula y - Gelijktijdige thermostatische la vanne et du ventilateur. der Ventile und des Ventilators. los ventiladores al mismo tiempo. regeling waterklep en ventilator. - Termostatazione sulla valvola e - Thermostatic control on the valve funzionamento continuo del ven- and continuous fan operation. tilatore. - Thermostatation sur la vanne - Temperaturregelung der Ventile - Termostatación sobre la válvula - Thermostatische regeling wateret fonctionnement continu du und Dauerbetrieb des Ventilators. y funcionamiento contínuo del klep en continue werking ventilator. ventilateur. ventilador. Idoneo per il controllo termostatico For the thermostatic control (ON(ON-OFF) della valvola acqua. OFF) of water valve. Adaptée au contrôle thermostatique Geeignet für die Thermostatsteuerung Apto para el control termostático Geschikt voor de thermostatische (ON-OFF) de la vanne à eau. (ON-OFF) der Wasserventile. (ON-OFF) de la válvula del agua. regeling (ON-OFF) de waterklep. La eventuale sonda di minima ac- Any TME minimum water probe qua TME deve essere collegata alla must be connected to terminal board. morsettiera. Si on installe une sonde de tempé- Die eventuelle Mindesstandsonde La eventual sonda de mínima agua De eventuele uitschakelthermostaat rature minimale eau TME, elle doit TME wird an die Klemmleiste TME se tiene que conectar a la caja TME moet aangesloten zijn op het angeschlossen. être raccordée au bornier. de bornes. klemmenbord. Collegando la sonda di minima (accessorio TME posta tra le alette della batteria di scambio termico), nel solo ciclo invernale, il ventilatore entrerà in funzione solamente se la temperatura dell’acqua è superiore a 42°C e verrà fermato quando quest’ultima è inferiore a 38°C. En connectant la sonde de température minimale (accessoire TME placée entre les ailettes de la batterie d’échange thermique), en cycle hiver seulement, le ventilateur ne se mettra en marche que si la température de l’eau est supérieure à 42°C et s’arrêtera quand celle-ci est inférieure à 38°C. 230Vac 50Hz L N Q1 PE L 1 2 3 4 5 6 7 8 9 10 N BK BU BU GNYE 6 BU 7 8 9 10 11 12 13 230V 50Hz 230Vac 50Hz L N Q1 PE L 15 GNYE M A 14 BK 5 RD 4 BU BK GNYE N OG MFC PE L 1 2 3 4 5 6 7 8 9 10 N BU BU GNYE 6 BU 7 8 9 10 11 M 13 Q1 PE L 15 E 230V 50Hz 230Vac 50Hz L N 14 GNYE B 12 BK 5 OG 4 BU BK GNYE N RD MFC PE L TMO-503-SV2 - Selección manual de las tres velo- - Manuele selectie van drie snelheden cidades del ventilador. voor de ventilator. 1 2 3 4 5 6 7 8 9 10 N BU BU GNYE BK 7 8 9 10 M 12 E 230V 50Hz C 11 13 14 GNYE BK 6 BK 5 OG 4 BU BU GNYE GNYE N RD MFC PE L N L PE MP B1 15 32 In the winter cycle only, if a minimum sensor is connected (TME accessory located between the fins of the heat exchange coil), the fan coil will start up only if the water temperature rises above 42°C and shut down when water temperature drops below 38°C. Durch Anschließen der Mindestsonde (Zubehör TME zwischen den Lamellen des Wärmetauscherregisters, wird der Ventilator nur eingeschaltet, wenn die Wassertemperatur über 42°C beträgt, und ausgeschaltet, wenn sie bis unter 38°C absinkt. Conectando la sonda de mínima (accesorio TME situado entre las aletas de la batería de cambio térmico), en el ciclo invernal, el ventilador entrará en función únicamente si la temperatura del agua es superior a 42°C y se cerrará cuando esta última sea inferior a 38°C. 32A Wanneer de uitschakelthermostaat in de wintercyclus (accessoire TME tussen de polen van de batterij voor de warmtewisseling), treedt de ventilator alleen in werking wanneer de temperatuur van het water 42°C overschrijdt en schakelt uit wanneer de temperatuur van het water onder 38°C zakt. TYPE CODE TMO-503-SV2 + SEL-CVP 9060173 + 9025302 TMO-503-SV2 L N Q1 SENZAVALVOLEnWITHOUTVALVES SANSVANNESn/HNEVENTILE SINVÈLVULASn:ONDERKLEPPEN 230Vac 50Hz 1 2 3 4 5 6 7 8 9 10 N L PE Applicato sulla struttura dei ventilconvettori, consente il controllo di più apparecchi (Max 8) su segnale di un unico comando remoto. Fitted to the frame of the fan coil, this enables up to eight units to be cotrolled by the signal from a single remote control unit. BU BU BU GNYE BK TMO-503-SV2 with SEL-CVP – Art. Nr. 9025302 6 BU 7 BK 8 9 10 11 12 13 14 15 GNYE Diese Vorrichtung wird an der Struktur der Gebläsekonvektoren angebracht und gestattet die Steuerung meherer (max. 8) Geräte mit dem Signal einer einzigen Fernbedienung. 5 BK Appliqué sur la structure des ventilo-convecteurs, permet de contrôler plusieurs appareils (8 maxi) sur signal d’une seule commande à distance. 4 RD DREHZAHLWÄHLSCHALTER EMPFÄNGER GNYE SELECTEUR DE VITESSE RECEPTEUR N OG MFC PE L BU TMO-503-SV2 avec SEL-CVP – Code 9025302 BK SPEED SELECTOR RECEIVER RD SELETTORE DI VELOCITÀ RICEVENTE 7 8 9 10 11 12 1 2 3 4 5 6 OG TMO-503-SV2 with SEL-CVP – Code 9025302 BN TMO-503-SV2 con SEL-CVP – Cod. 9025302 M 230V 50Hz SNELHEIDSSCHAKELAAR ONTVANGER Aplicado en la structura de los fan coils permite controlar varios aparatos (como máximo 8) mediante la señal de un único mando a distancia. Gemonteerd op de structuur van de ventilatorconvectors, voor de bediening van meerdere apparaten (max 8) via een signaal afkomstig van één enkele afstandsbediening. 1 2 3 4 5 6 7 8 9 10 11 12 BN BU BK SELECTOR DE VELOCIDAD RECEPTOR OG TMO-503-SV2 met SEL-CVP – Code 9025302 RD TMO-503-SV2 con SEL-CVP – Cód 9025302 BK BU BU GNYE BK 7 8 9 10 11 12 M 230V 50Hz 33 13 14 GNYE BU 6 BK 5 OG 4 BU GNYE N RD MFC PE L 33A 15 TYPE CODE TMO-503-SV2 + SEL-CVP 9060173 + 9025302 L N Q1 CONVALVOLAnWITHVALVE AVECVANNEnMIT6ENTIL CONVÈLVULAnMETKLEP TYPE CODE TMO-503-SV2 + SEL-CVP 9060173 + 9025302 TMO-503-SV2 TMO-503-SV2 L N 230Vac 50Hz Q1 CONVALVOLAEPOMPAnWITHVALVEANDPUMP AVECVANNEETPOMPEnMIT6ENTILUNDPOMPE CONVÈLVULAYBOMBAnMETKLEPENPOMP 230Vac 50Hz 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 PE N N PE BN BK RD BK GNYE BU BU BU BU GNYE BK MFC 14 M MFC PE L 15 N 4 5 6 BU 7 BK 15 15 4 5 BU 7 GNYE BK 6 BK OG 8 9 10 11 12 M E E 230V 50Hz 230V 50Hz N L PE 34 13 14 GNYE 14 N BK 13 GNYE BK OG 12 B1 BU BU BU 11 BK 10 M 14 MFC PE L GNYE GNYE 9 OG 8 RD BU BK 7 MP RD BU GNYE BU BU 6 13 7 8 9 10 11 12 BN BK OG RD BN BU GNYE 5 12 E 1 2 3 4 5 6 MFC 4 11 M 7 8 9 10 11 12 1 2 3 4 5 6 BU 10 230V 50Hz N L PE N 9 E 230V 50Hz PE L 8 GNYE 13 BK 12 RD 11 OG 10 BU 9 GNYE BK 8 RD BU 7 GNYE GNYE 6 BK 5 RD 4 OG N BU GNYE PE L L 7 8 9 10 11 12 1 2 3 4 5 6 BU BU BN RD OG 7 8 9 10 11 12 OG 1 2 3 4 5 6 L MP B1 34A 15 TME – Cod. 3021091 TME SONDA DI MINIMA – Code 3021091 TME TME – Art. Nr. 3021091 MINDESTTEMPERATURFÜHLER – Cód. 3021091 SONDA DE MÍNIMA TME – Code 3021091 UITSCHAKELTHERMOSTAAT Abbinabile ai comandi: 4-/44-/4!5 Associable aux commandes: 4-/44-/4!5 For use with control units: 4-/44-/4!5 Kombinierbar mit den Combinable con los Steuerungen: 4-/44-/4!5 dispositivos de accionamiento: 4-/44-/4!5 Combinerend met de bedieningen: 4-/44-/4!5 Per il collegamento al comando, il When connecting the control, the cavo della sonda TME deve essere TME probe cable must be separated separato dai conduttori di potenza. from the power supply wires. Pour le raccordement à la commande, Für den Anschluss an die Steuerung Para la conexión al mando, el cable Voor de aansluiting op de besturing, le câble de la sonde TME doit être muss das Kabel des Fühlers TME von de la sonda TME debe separarse moet de kabel van de TME-sonde séparé des câbles de puissance. den Leistungsleitungen getrennt sein. de los conductores de potencia. gescheiden zijn van de stroomdraden. Durante il funzionamento invernale arresta l’elettroventilatore quando la temperatura dell’acqua è inferiore ai 38°C, e lo fa ripartire quando questa raggiunge i 42°C. Pendant le fonctionnement hiver arrête le ventilateur quand la température de l’eau est inférieure à 38°C et le fait repartir quand elle atteint 42°C. SONDA DI MINIMA During winter operation stops the fan when the water temperature drops below 38°C and starts it up again when the temperature reaches 42°C. TMM – Code 9053048 LOW TEMPERATURE CUT-OUT THERMOSTAT TMM – Code 9053048 SONDE DE TEMPÉRATURE MINIMUM Der Fühler hält bei Winterbetrieb den Ventilator an, wenn die Temperatur des Wassers unter 38°C ist, und setzt ihn wieder in Betrieb, wenn sie 42°C erreicht hat. TMM Durante el funcionamiento en invierno para el electroventilador cuando la temperatura del agua es inferior a 38°C y lo vuelve a poner en marcha cuando esta alcanza los 42°C. TMM – Art. Nr. 9053048 MINDESTTEMPERATURFÜHLER – Cód. 9053048 SONDA DE MÍNIMA Tijdens de wintercyclus schakelt hij de elektroventilator uit als de temperatuur van het water minder dan 38°C bedraagt, en opnieuw inschakelt als de temperatuur 42°C bereikt. TMM – Code 9053048 UITSCHAKELTHERMOSTAAT Da posizionare in contatto con il tubo di alimentazione. Position in contact with the water supply pipe. Doit être placée en contact avec le tuyau d’alimentation. Diese Sonde wird in Kontakt mit dem Zuleitungsrohr angebracht. A colocar en contacto con el tubo Moet in contact met de voedingsde alimentación. leiding geplaatst worden. Abbinabile ai comandi: -/6#24 For use with control units: -/6#24 Associable aux commandes: -/6#24 Kombinierbar mit den Steuerungen: -/6#24 Combinable con los dispositivos de accionamiento: -/6#24 Arresta l’elettroventilatore quando la temperatura dell’acqua è inferiore ai 30°C, e lo fa ripartire quando questa raggiunge i 38°C. CH 15-25 – Cod. 9053049 CHANGE-OVER Combinerend met de bedieningen: -/6#24 Valide pour des appareils fonction- Gültig nur für den Heizbetrieb. nant uniquement en hiver. Vale para aparatos que funcionan Alleen van toepassing voor apparaten sólo en inverno. die alleen op wintercyclus werken. Stops the fan when the water temperature drops below 30°C and starts it up again when the temperature reaches 38°C. Arrête le ventilateur quand la température de l’eau est inférieure à 30°C et le fait repartir quand elle atteint 38°C. Stoppt den Elektroventilator, wenn die Wassertemperatur unter 30°C liegt und setzt ihn wieder in Gang, wenn sie 38°C erreicht. Detiene el electro-ventilador cuando la temperatura del agua es inferior a los 30°C y lo pone de nuevo en marcha cuando la temperatura alcanza los 38°C. CH 15-25 CH 15-25 CH 15-25 Valido per apparecchi funzionanti Valid for winter mode operation unicamente in inverno. only. CH 15-25 RD TME SONDE DE TEMPÉRATURE MINIMUM Doit être placée entre les ailettes Diese Sonde wird zwischen den A colocar entre las aletas de la Te plaatsen tussen de ribben van de la batterie d’échange thermique. Leitlamellen der Wärmetauscher- batería de intercambio térmico. de warmtewisselaars. Batterie angebracht. TMM – Cod. 9053048 BN – Code 3021091 LOW TEMPERATURE CUT-OUT THERMOSTAT Da posizionare fra le alette della Position between the fins of the batteria di scambio termico. heat exchanger coil. TMM RD TME – Code 9053049 CHANGE-OVER – Code 9053049 CHANGE-OVER – Art. Nr. 9053049 CH 15-25 CHANGE-OVER – Cód. 9053049 CHANGE-OVER Schakelt de elektroventilator uit wanneer de watertemperatuur minder dan 30°C bedraagt, en schakelt hem weer in als de temperatuur 38°C bereikt. CH 15-25 – Code 9053049 CHANGE-OVER Cambio stagionale automatico da Automatic summer/winter switch to posizionare in contatto con il tubo be installed in contact with the water di alimentazione. circuit (for 2-tube installations only). Commutateur saisonnier automa- Automatischer Saisonwechsel, in Cambio estacional automático que Automatische seizoenwisseling die tique à installer en contact avec le Kontakt mit dem Wasserrohr zu se tiene que colocar en contacto in contact met de voedingsleiding tube d’alimentation. installieren. con el conduco de alimentación. moet worden geplaatst. Solamente per impianti a due tubi Only for 2 pipe installations (not (non utilizzabile con la valvola a to be used with 2 way valve). 2 vie). Uniquement pour installations à Nur für 2-Leiter-Anlagen (nicht Solo con instalaciones con 2 tubos Enkel voor installaties met twee 2 tubes (non compatible avec la verwendbar mit dem 2-Wege-Ventil). (no se puede utilizar con la válvula leidingen (not to be used with 2 vanne à 2 voies). de dos vías). way valve). Abbinabile ai comandi: 4-/44-/4!5 Associable aux commandes: 4-/44-/4!5 For use with control units: 4-/44-/4!5 Kombinierbar mit den Combinable con los Steuerungen: 4-/44-/4!5 dispositivos de accionamiento: 4-/44-/4!5 BK 35 35A Combinerend met de bedieningen: 4-/44-/4!5 Cod. / Code Code / Art. Nr. Cód. / Code 9025309 POMPA DI EVACUAZIONE CONDENSA 1 2 CONDENSATE PUMP POMPE D’EVACUATION DES CONDENSATS KONDENSATPUMPE BOMBA DE EVACUATIÓN DE CONDENSADOS 5 6 Mandata pompa Condensate Discharge Refoulement pompe Austrittseite der Pumpe Impulsion de la bomba Pompblok Ø6 3 4 36 CONDENSWATERPOMP 7 36A Ø i6 PULIZIA, MANUTENZIONE, RICAMBI ATTENZIONE! PRIMA DI QUALSIASI PULIZIA E MANUTENZIONE, TOGLIERE L’ALIMENTAZIONE !,,!00!2%##()/ CLEANING, MAINTENANCE AND SPARE PARTS IMPORTANT! BEFORE CARRYING OUT CLEANING OR MAINTENANCE, MAKE SURE THE POWER TO THE UNIT )3452.%$/&& NETTOYAGE, REINIGUNG, ENTRETIEN ET PIECES WARTUNG UND DE RECHANGE ERSATZTEILE ATTENTION! AVANT TOUTE OPERATION DE NETTOYAGE ET D’ENTRETIEN, COUPER L’ALIMENTATION $%,!00!2%), LIMPIEZA, MANTENIMIENTO Y REPUESTOS ACHTUNG! VOR BEGINN VON REINIGUNGS- UND WARTUNGSEINGRIFFEN MUSS DIE STROMZUFUHR ZUM GERÄT 5.4%2"2/#(%.7%2$%. ATENCIÓN! ANTES DE EFECTUAR CUALQUIER OPERACIÓN DE LIMPIEZA Y MANTENIMIENTO CORTAR LA ALIMENTACIÓN 0!2!%,!0!2!4/ SCHOONMAAK, ONDERHOUD, WISSELSTUKKEN OPGELET! VOOR ELKE SCHOONMAAK- EN ONDERHOUDSBEURT, DE STEKKER VAN HET APPARAAT UIT HET 34/0#/.4!#442%++%. Solo personale addetto alla manu- Maintenance of the unit must be tenzione e precedentemente ad- carried out by trained maintenance destrato, può intervenire sulle ap- personnel only. parecchiature. Seul le personnel chargé de l’entretien Nur das mit der Wartung betraute et ayant été formé dans ce but peut und vorher entsprechend geschulte intervenir sur les appareils. Personal darf Eingriffe an den Geräten vornehmen Sólo personal encargado del mante- Wend u uitsluitend tot opgeleid nimiento y previamente capacitado onderhoudspersoneel voor het puede efectuar operaciones sobre onderhoud van het apparaat. los aparatos. FAN: ELETTROVENTILATORE: Non richiede alcun tipo di manu- No maintenance required. tenzione. ELEKTROVENTILATOR: VENTILATEUR: Ne nécessite aucun type d’entretien. Dieser bedarf keinerlei Wartung. ELEKTROVENTILATOR: VENTILADOR: No requiere ninguna clase de Vergt geen enkel type onderhoud. mantenimiento. HEAT EXCHANGER COIL: BATTERIA: Non richiede alcun tipo di ordina- No ordinary maintenance required. ria manutenzione. BATTERIE: BATTERIE: BATERÍA: "!44%2)J Ne nécessite aucun type d’entretien. Diese bedarf keiner ordentlichen No requiere ninguna clase de Vergt geen enkel type gewoon ordinaire. Wartung. mantenimiento ordinario. onderhoud. FILTRO: Con l’ausilio di un utensile, sganciare il profilo portafiltro ed estrarre il filtro dalle guide. FILTER: Using a suitable tool, unhook the filter holder strip and extract the filter from the guides. FILTRE: Au moyen d’un outil, décrocher le profilé porte-filtre et retirer le filtre de ses guides. FILTER: Mit Hilfe eines Werkzeugs das Filter-Halteprofil aushängen und den Filter aus den Führungen nehmen. FILTRO: Con el auxilio de una herramienta, desenganchar el perfil porta-filtro y retirar el filtro de las guías. FILTER: Met behulp van gereedschap, haakt u de filterhouder los en haalt u hem uit zijn zitting. Si pulisce periodicamente usando Clean regularly with a vacuum un’aspirapolvere oppure percuo- cleaner or shake lightly. tendolo leggermente. Doit être nettoyé périodiquement Der Filter wird regelmäßig mit Se limpia periódicamente usando Maak de filter regelmatig schoon à l’aide d’un aspirateur ou en le einem Staubsauger oder durch una aspiradora o golpeándolo lige- met een stofzuiger of door er zacht vorsichtiges Ausklopfen gesäubert. ramente. op te kloppen. frappant légèrement. Sostituirlo nel caso non si possa When it can no longer be cleaned, più pulire. replace. Le remplacer lorsqu’il n’est plus Wenn er sich nicht mehr reinigen Si no es posible limpiarlo sustituirlo. Vervang de filter indien hij niet kan possible de le nettoyer. lässt, muss er ersetzt werden. worden schoongemaakt. RICAMBI: Per l’ordinazione delle parti di ricambio citare sempre il modello dell’apparecchio e la descrizione del componente. SPARE PARTS: To order spare parts, always give the model of appliance and a description of the component. PIECES DE RECHANGE: Pour la commande des pièces de rechange, indiquer toujours le modèle de l’appareil et la description du composant. ERSATZTEILE: Bei Ersatzteilbestellungen immer das Gerätemodell und die Bezeichnung des Teils angeben. REPUESTOS: Para pedir piezas de repuesto indicar siempre el modelo del aparato y la descripción del componente. WISSELSTUKKEN: Bij de bestelling van de wisselstukken, vermeld u steeds het model van het apparaat en beschrijft u het onderdeel. ATTENZIONE! RIMONTARE SEMPRE IL FILTRO DOPO ,!35!05,):)! IMPORTANT! ALWAYS REPLACE THE FILTER !&4%2#,%!.).' ATTENTION! APRES L’AVOIR NETTOYE, NE JAMAIS OUBLIER DE REMONTER ,%&),42% ACHTUNG! NICHT VERGESSEN, DEN FILTER NACH DER REINIGUNG 7)%$%2%).:5"!5%. ATENCIÓN! DESPUÉS DE LIMPIARLO VOLVER A MONTAR SIEMPRE EL FILTRO %.353)4/ OPGELET! HERPLAATS DE FILTER STEEDS NA EEN 3#(//.-!!+"%524 37 37A RICERCA GUASTI TROUBLESHOOTING DEPANNAGE FEHLERSUCHE INVESTIGACIÓN DE AVERÍAS OPSPOREN DEFECTEN GUASTO 1 - Il motore non gira o gira in modo non corretto. PROBLEM 1 - The motor does not rotate or rotates incorrectly. DEFAUT 1 - Le moteur ne tourne pas ou tourne de manière incorrecte. STÖRUNG 1 - Der Motor dreht nicht oder dreht nicht korrekt. AVERÍA 1 - El motor no gira o gira de modo incorrecto. DEFECT 1 - De motor draait niet of op niet correcte wijze. RIMEDIO - Controllare che l’alimentazione sia inserita. REMEDY - Make sure the power to the unit is on. ACTION CORRECTIVE - Contrôler que l’alimentation est branchée. ABHILFE SOLUCIÓN - Kontrollieren, ob die Spannungs- Verificar que esté conectado a la toma de corriente. versorgung zugeschaltet ist. OPLOSSING - Controleer of de stekker in het stopcontact zit. - Verificare il collegamento corretto dei fili, osservando gli schemi elettrici. - Make sure the wires are correctly connected, referring to the wiring diagram. - Vérifier le bon raccordement des conducteurs à l’aide des schémas électriques. - Auf Grundlage der Schaltpläne den korrekten Anschluss der Drähte prüfen. - Verificar la correcta conexión de los hilos, observando los esquemas eléctricos. - Controleer de correcte aansluiting van de draden, conform de schakelschema’s. - Verificare la posizione dell’interruttore generale, del commutatore stagionale e del termostato. - Control if the main switch, the seasonal commutator and the thermostat are in the right position. - L’interrupteur général et le commutateur saisonnier soient dans la position correcte. - Die Position des Hauptschalters, des Umschalters der Betriebsart und des Thermostats kontrollieren. - Verificar la posición del interruptor general, del conmutador estacional y del termostato. - Controleer de positie van de hoofdschakelaar, de seizoensschakelaar en de thermostaat. GUASTO 2 - L’apparecchio non scalda/raffredda più come in precedenza. PROBLEM 2 - The unit does not heat/cool as before. DEFAUT 2 - L’appareil ne chauffe ou ne refroidit plus comme avant. STÖRUNG 2 - Das Gerät heizt/kühlt nicht mehr wie zuvor. AVERÍA 2 - El aparato ya no calienta/enfría como con anterioridad. DEFECT 2 - Het apparaat verwarmt/koelt niet meer af zoals voordien. RIMEDIO - Controllare che il filtro sia sufficientemente pulito. REMEDY - Make sure the filter is clean. ACTION CORRECTIVE - Contrôler que le filtre est suffisamment propre. ABHILFE - Kontrollieren, ob der Filter sauber genug ist. SOLUCIÓN - Verificar que el filtro esté bien limpio. OPLOSSING - Controleer of de filter voldoende schoon is. - Verificare sfiatando la batteria che non sia entrata aria nel circuito idraulico. - Make sure the hydraulic circuit is free from air by venting the heat exchanger. - Vérifier, en purgeant la batterie, que de l’air n’est pas entré dans le circuit hydraulique. - Durch Entlüften des Registers kontrollieren, ob Luft in den Wasserkreis eingedrungen ist. - Verificar purgando la batería que no haya entrado aire en el circuito hidráulico. - Tap de batterij af en ga de aanwezigheid na van lucht in het hydraulisch circuit. GUASTO 3 - L’apparecchio perde acqua. PROBLEM 3 - The appliance leaks water. DEFAUT 3 - L’appareil perd de l’eau. STÖRUNG 3 - Das Gerät verliert Wasser. AVERÍA 3 - El aparato pierde agua. DEFECT 3 - Er lekt water uit het apparaat. RIMEDIO - Controllare che l’inclinazione sia in direzione dello scarico condensa. REMEDY - Make sure it is sloping in the direction of the condensate drain. ACTION CORRECTIVE - Contrôler que l’évacuation des condensats est inclinée dans la bonne direction. ABHILFE - Kontrollieren, ob die Schräge in Richtung des Kondensatabflusses verläuft. SOLUCIÓN - Controlar que esté inclinado en dirección a la evacuación del agua de condensación. OPLOSSING - Controleer of de helling in de richting van de afvoerbuis voor het condensatievocht loopt. - Controllare che lo scarico condensa non sia ostruito. 38 - Make sure the condensate drain is not clogged. - Contrôler que l’évacuation des condensats n’est pas bouchée. - Kontrollieren, ob der Kondensatabfluss frei ist. - Controlar que la evacuación del agua de condensación no esté obstruida. 38A - Controleer of de afvoerbuis voor het condensatievocht niet verstopt is. PERDITE DI CARICO LATO ACQUA - PRESSURE DROP TABLE PERTES DE CHARGE CÔTE EAU - DRUCKVERLUSTE WASSER PÉRDIDAS DE CARGA LADO AGUA - WATERLEKKEN Dp - kPa Batteria a 2 ranghi 60 ROWBATTERY Batterie à 2 rangs 50 Register mit 2 Rohrreihen "ATERÓADElLAS 40 "ATTERIJMETRIJEN 30 20 10 0 0 100 200 300 400 500 600 700 Portata acqua (l/h) - Water flow (l/h) - Débit d’eau (l/h) Wasserdurchflussmenge (l/h) - Caudal de agua (l/h) - Waterdebiet (l/h) La perdita di carico si riferisce ad una temperatura media dell’acqua di 10°C; per temperature diverse, moltiplicare la perdita di carico per il coefficiente K riportato in tabella. The table indicates the pressure drop for a mean water temperature of 10°C For different water temperatures multiply by the correction factors + La perte de charge se référe à une température moyenne d’eau de 10°C Pour une température différente, multiplier la perte de charge par le coefficient K de le table suivante. Der Druckverlust bezieht sich auf eine durchschnittliche Temperatur des Wassers von 10°C; für abweichende Temperaturen den Druckverlust mit dem Koeffizienten K der Tabelle multiplizieren. La pérdida de carga se refiere a una temperatura media del agua de 10°C; para temperaturas distintas multiplicar la pérdida de carga por el coeficiente K que figura en la tabla. Het energieverlies verwijst naar een gemiddelde watertemperatuur van 10°C; bij verschillende temperaturen vermenigvuldigt u het energieverlies met de coëfficiënt K die u in de tabel vindt. °C 20 30 40 50 60 70 80 K 0,94 0,90 0,86 0,82 0,78 0,74 0,70 39 NOTES NOTES NOTES
© Copyright 2024 ExpyDoc