SUBMITTAL DATA SHEET SINGLE PIECE ECM AIR HANDLER SPLIT-SYSTEM COIL MODELS: AHV JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. PRODUCT DATA Cooling Performance Total Capacity*________________ MBH Sensible Capacity*_____________ MBH Temperature of Air Entering Indoor Coil________________°F (DB/WB Supply Air Blower Performance Total Supply Air_________________CFM Total Resistance External To Unit ______IWG Cooling Blower Speed Tap______RPM Motor Rating ____________________HP Electrical Data Power Supply ________/__/__ Total Unit Ampacity ____________AMPS Minimum Wire Size _____________AWG (Copper conductors) Maximum Overcurrent Device_______AMPS Fuses (Dual Element) Circuit Breaker (HACR) CONSTRUCTION: MODEL NO. FEATURES • • • • • • • • • • • Cooling or Heat Pump Applications Durable pre-painted galvanized steel cabinet Upflow/Horizontal (4 way Position) Multi-position models easily converted to Horizontal & Dowflow Composite drain pan for added strength and positive condensate removal. TXV refrigerant controls on all models (field installed) ECM motor, variable speed, Direct Drive Easy removal of blower and coil for service access Field installed electric heaters available (1 & 3 phase) 6HK Series Thermally insulated with 3/4” foil faced insulation (meet Florida requirements) Compatible with communicationg control FIELD INSTALLED ACCESSORIES Electric Heaters (#6HK____________________________) Capacity (@___________Volts) _____________MBH Power Input Requirement (Less Blower Motor) ______KW Thermal Expansion / Check Valve Kit (#____________) MATCHED OUTDOOR UNIT Unit Weight Total Operating Weight ________LBS (Including field-installed accessories) * Shown in Outdoor Unit Technical Guide Model Number (#_____________________________) Submittal Part Number (#________________________) CLEARANCES Front 24” Rear 0”* Sides 0”* * 0 Clearance allowed with or without Electric Heater. ISO 9001 Certified Quality Management System 1169651-USD-A-1114 DIMENSIONS & DUCT CONNECTION DIMENSIONS F J 13” K Blower Compartment Top Outlet Dimensions A Refrigerant Connections D Service Disconnect Panel Drain Connections for Upflow Applications 7-11/32” 20-5/16” C 1-1/2” E Bottom Inlet Dimensions B Drain Pan Connections for Horizontal Applications Filter Access A024-001 Dimensions Dimensions Models A B C Depth Wiring Knockouts D E F Height Width AHV18B3X(H,T)21 46” 17 1/2” 16 1/2” 13-29/32" 16 1/2” J K Power Control AHV24B3X(H,T)21 46” 17 1/2” 16 1/2” 13-29/32" 16 1/2” AHV30B3X(H,T)21 46” 17 1/2” 16 1/2” 13-29/32" 16 1/2” AHV36C3X(H,T)21 52” 21” 21 1/2” 17-13/32" AHV42D3X(H,T)21 57’ 24 1/2” 26” 20-29/32" 7/8" (1/2")1 20” 7/8" (1/2") 1-3/8"(1") 23-1/2” 1-23/32" (1-1/4") AHV48D3X(H,T)21 57” 24 1/2” 26” 20-29/32" 23-1/2” AHV60D3X(H,T)21 57” 24 1/2” 26” 20-29/32" 23-1/2” 21 1/2” Refrigerant Connections Line Size Liquid Vapor 3/4" 3/8" 7/8" 1. Actual size (Conduit size). Subject to change without notice. Published in U.S.A. Copyright © 2014 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 1169651-USD-A-1114 Supersedes: 824757-USD-B-0514
© Copyright 2024 ExpyDoc