IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IIECEX BAS 08.0122X issue No. :61 Status: ICurrent Date of Issue: 2014·02·18 Applicant: Topworx Incorporated Page 1 of 4 I ~~E~i!j~~!~_~_i_~!<?!Y~_h 3300 Fern Valley Road Louisville Kentucky 40213 United States of America Electrical Apparatus: Opffonalaccessorr: Series 7 Proximity Switches Type of Protection: Ex d, Ex tD Marking: Ex d IIC Gb T6 (-40°C or T4 (-40°C or T3 (-40°C ~Ta ~+50°C) with PVC leads with TEFLON leads ~+150°C) with PEEK leads ~Ta ~+100°C) ~Ta Ex tb IIiC Db T85°C (-40°C ~Ta ~+50°C) IP66 with PVC leads or T135°C (-40°C ~a ~+100°C) IP66 with TEFLON leads or T200°C (-40°C ~a ~+150°C) IP66 with PEEK leads Approved for issue on behalf of the IECEx Certification Body: R S Sinclair Position: General Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SGS Baseefa Limited Rockhead Business Park Staden Lane Buxton Derbyshire SK179RZ United Kingdom _ Issue NO.6 (2014-2-18) Issue NO.5 (2013-4-9) Issue NO.4 (2012-6-8) Issue NO.3 (2010-4-7) Issue NO.2 (2009-6-11) Issue No. 1 (2009-2-5) Issue No. 0 (2009-1-6) I I IECEx Certificate of Conformity Certificate No.: IECEx BAS 08.0122X Date of Issue: 2014·02·18 Issue No.: 6 Page 2 of4 Topworx Incorporated Manufacturer: 3300 Fern Valley Road Louisville Kentucky 40213 United States of America Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079·0 : 2011 Explosive atmospheres - Part 0: General requirements Edition: 6.0 IEC 60079·1 : 2007·04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Edition: 6 IEC 60079·31 : 2008 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure It' Edition: 1 This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/BAS/ExTR08.0252/00 GB/BAS/ExTR10'.0037/00 GB/BAS/ExTR13.0211/00 Quality Assessment Report: GB/SI R/QAR07. 0025/05 GB/BAS/ExTR09.0023/00 GB/BAS/ExTR12.0153/00 GB/BAS/ExTR09.0108/00 GB/BAS/ExTR13.0078/00 IECEx Certificate of Conformity Certificate No.: IECEx BAS 08.0122X Date of Issue: 2014-02-18 Issue No.: 6 Page 30f4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: or O.5Aand iTh-e Series7Proximfty Switches are rated upto i40V a~c,,-2A 24Vd~., camp-rise a-tubularstainless steel ~ :enclosure in a variety of body styles, with an 5/8 UNF, 1" UNS or M18 external male thread and a thin section wall at the front end. The rear end of the enclosure is a hexagonal section with a 1/2 NPT or M20 female thread for connection to conduit or a suitable cable entry device. The integral connection leads exit the enclosure via a potted seal assembly within ~he rear entry. i I IThe internal cavity contains a magnetically operated switch assembly. I lAn internal earth connection is provided by one of the integral conductors. External earth bonding may be achieved by either the external switch mounting thread or by the rear cable entry thread. I iVariation 0.1 An alternative Type 75 body style with a male %" NPT mounting thread at the rear. Variation 0.2 ,An alternative high temperature option (incorporating Teflon or PEEK insulated leads only) with a T3 Temperature o ;Classification for use in an ambient temperature range of -40°C to +150 C CONDITIONS OF CERTIFICATION: YES as shown below: termTnafecfli1a T:--"The integrarsup-plycables'"must be mech"anTcalTy protectecfand suitable ferminal or}unctio'n'faciiIty~-2~-An ;external earth bonding connection may be maintained by either the external mounting thread and/or the internal cable : gland/conduit entry thread. I lEe ~. IECEx Certificate of Conform ity EEx Certificate No.: IECEx SAS 08.0122X Date of Issue: 2014-02-18 Issue No.: 6 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): iV ariation6.1-- - - ----- - - - iTo permit a variation to the Type 73 Series Proximity Switch configured with IS' leads PVC and Insulcast 116 FR with a temperature range of -60°C to +50°C. l !This variant may be marked as follows:! ,Ex d lie T6 Gb (-60°C STa + 50°C) with B leads PVC 'Ex tb IIiC T85°C Db (-60°C STa + 50°C) IP66 with B leads PVC I Ivariation 6.2 o confirm that the Series 7 Proximity Switches are rated up to maximum values as follows:- SPOT Switch DPDT Switch Va.c. 240 120 240 120 - Vd.c. 24 24 A 2 4 3 2 3 1 'As the heat dissipated by the switch is a function of the switch passing current (P=1 2 R) rather than consuming current the maximum values stated above can be considered to include any values for current which dissipate less energy across the switch than the maximum listed above for example:- 125 V d.c / 0.5A I I I ExTR: GB/BAS/ExTR13.0211/00 L._._ File Reference: 13/0512
© Copyright 2024 ExpyDoc