SalvisLab Coolingcenter CIC – Cooling Incubator with

SalvisLab Coolingcenter CIC –
Cooling Incubator with Swiss Precision
SalvisLab Coolingcenter CIC – reliable and
powerful
The cooled Incucenter
SalvisLab Coolingcenter CIC150 is our solution for cooled incubation processes. Coolingcenter
stands for incubation of microbiological cultures and for reproducible results in every routine
test in the laboratory - especially by high batch througtputs during long-term operation. The
CIC is built to last, in typical SalvisLab Swiss Quality. The exclusive EasyMenu controller from
SalvisLab provides an uniform and constant level of temperature conditions at any and all
location within the chamber.
Swiss quality and design
SalvisLab Coolingcenter are setting
standards in quality and design. The
units are manufactured in typical
Swiss quality and convince of
accuracy, dependability and design.
Safety through
cleanliness
SalvisLab Coolingcenter are
easy to clean.
High payload
Each Incubator comes
with two grid shelves as
standard equipment. They
are designed for high
payload and their grid
design allow unimpeded
air convection.
Established
technology
SalvisLab uses the well
known compressor
technology. This
together with our
intelligent controlling
system reduces the
energy consumption.
Full control with the
SalvisLab EasyMenu
SalvisLab developed the EasyMenu which leads you through
operation and programming of
the Coolingcenter in plain
steps. The illuminated LCD
display of the PID controller
features fuzzy logic capabilities
and keeps you informed of all
required data during the full
process cycle. Serial interface
RS 232. SalvisLab software
«STS» is optional available for
programming and data logging
according to 21 CFR part 11
(GLP/GMP/FDA conform).
Technical Data SalvisLab Coolingcenter CIC
D
W
w
H
h
d
Coolingcenter CIC
Outside dimensions (WxHxD)
Inside dimensions (wxhxd)
Clearance distance from back/side wall
Internal volume
Shelves
Shelf dimension (WxD)
Distance between shelves
Max. load per shelf
Max. load per CIC
Weight (empty) CIC
Temperature Range
Temperature variation1)
Temperature fluctuation2)
Heating up time3)
Recovering time after 30 sec door opening3)
Power supply (±10%) 50/60 Hz
Heating power / Cooling power, at 20°C
Energy consumption
Microprocessor controller with LCD display
Timer
RS 232 Interface
Adjustable print interval
Programming
Refrigerant
Safety class
1)
2)
3)
at 5/25/37°C
at 5/25/37°C
to 23 - 37°C
at 5/25/37°C
at 20/37°C
mm
mm
mm
l
standard/max.
mm
mm
kg
kg
kg
°C
±°C
±°C
min.
min.
volt
watt
watt/hours
hours/min.
program/step
class
measured with 3 temperature probes on horizontal level / divides in 1/3 of the chamber size
maximum temperature deviation in time for one temperature probe
to 98% of set temperature
We reserve the right to alter technical specifications at any time without prior notice.
Manufacturer:
Renggli AG
Industrie-Ost
CH-6343 Rotkreuz (Switzerland)
Phone +41 (0)41 798 14 14
Fax
+41 (0)41 798 14 40
[email protected]
www.salvislab.com
CIC150
685x860x755
490x495x595
100/100
150
2/13
450x555
20
20
100
75
5 - 60
0.4/0.4/0.4
0.1/0.1/0.1
5
2/1/4
230/115
900/200
370/60
yes
999/59
yes
yes
50/15
R134a
3.1