Specifications The Frame At EFI, only the best materials are used to construct the building. Galvanized, steel studs, joists, and channels are used in the building framework. Optional wood framing is available. Custom Designed, Factory-Built Modular Structures Wall studs are 3-5/8” 20 gauge steel or 6” 20 gauge steel placed a maximum of 16” on center. Roof joists, placed 16” center, are aluminum 8”, 16 gauge steel. All of the openings in walls or roof are fully framed. By The Walls Enclosures For Industry Our walls are constructed by applying 3/4” exterior grade plywood to the inside of the wall framing. The plywood is nailed and screwed to the framing. Fiberglass Reinforced Plastic (FRP) pebble grain sheeting is glued to the entire interior wall and ceiling surface. Seam and corner moldings are used to finish the joints. Two part spray polyurethane insulation is applied in the wall cavaties forming an airtight seal. 1/2” exterior grade plywood is applied to the outside of the framing. No OSB or particle board is used in EFI construction. The Ceiling The ceiling of our EFI buildings are made the same as the walls. The roofing insulation has an R-28 value, and the roof can be flat or pitched. Ceiling joists are rated for various live and dead loads based on the site requirements and building use. The Floor In most applications, the floor is 1/4” steel plate on a structural steel frame. The entire floor and substructure is grit blasted and coated with two-part epoxy to a .008’ DFT. Exterior Finish The standard exterior finish is 3/16” fiberglass coating over all exterior surfaces, walls and roof. The roof and sidewalls have fiberglass applied from the outside to form a seamless exterior surface. Once the exterior surface has dried, a UV resistant gelcoat is applied. Multiple finish styles, colors and textures are available. Many other exterior finishes are available, vinyl, masonry, cement boards, etc. The Roof EFI buildings come standard with a fiberglass roof with a 1/2” :12” pitch. Optional roof structures and coverings are available including: - Shingled Roof, Fiberglass or Steel - Metal Standing Seam Roof - Roof Hatches - Trussed Roof System - Hip or Gable - Flat Roof for Field Installed Roof Structure The Doors and Hardware Single or double, aluminum or steel doors are provided flush or outset frames with lock sets, panic hardware, doors, windows and other options. Overhead doors are also an option Design Criteria - Minimum Design Loads for Buildings and Other Structures - ASCE 7-05 American Society of Civil Engineers - 2006 International Building Code - 2008 National Electrical Code R R - AISI - Standard for Cole-Formed Steel Framing General Provisions - Specific State Certifications/Approvals Are Available - AISI - Specification for the Design of Cold-Formed Steel Structural Members; 1996 Engineered Fluid, Inc. I F E y l On PO Box 723, Centralia, IL 62801 (618) 533-1351 Fax (618) 533-1459 www.engineeredfluid.com or [email protected] Multiple Compartments in One Building Double and Triple Connected Buildings Single Building Size up to 15 Ft x 52 Ft Placement on Slab or Foundation Wall With or Without Floors Code Constructed Electrical and Mechanical System Outfitted Various Exterior Finishes Various Roof Shapes and Materials EFI Building Cutaway for Construction Det ails and Materials Single Building Widths up to 15’ Wide Every Building Is Custom Designed 3 Buildings In One Single Building Lengths up to 52’ Long 1/2” CDX Exterior Plywood Roof Truss for 1/2”:12 Slope Field applied brick exterior with a standing seem metal roof Modular triplex with field applied brick and split face block exterior with faux windows and doors and a field applied gable roof 8” Roof Joist 8” Rim Joist 3 5/8” Stud Track .090” FRP Paneling with seam and corner strips Standard fiberglass/gelcoat exterior with a roof top HVAC unit Factory applied vinyl siding with windows and a shingled hip roof 3/4” CDX Interior Plywood 2 Buildings In One Foam-in-place Insulation (R-7 Per Inch) 1/2” CDX Exterior Plywood 3 5/8” Stud (Optional 6” Stud) ASTM Galvanized Steel Framing Members 3 5/8” Stud Track 6” x 2” x 1/4” Steel Tubing Three compartment building with Hardie Plank fiber cement siding and a shingled hip roof Modular duplex with standard Fiberglass/Gelcoat exterior and field applied shingled roof Vertical ribbed steel Siding with a 1/2:12” pitch fiberglass/gelcoat roof with HVAC Factory applied house wrap with provisions for brick exterior to be applied in the field and a standing seem metal roof *See back cover for building specs Log siding exterior with a shingled, hip roof Vertical ribbed, steel siding with a standing seam metal roof Aggregate panels with vertical ribbed pattern with a 1/2:12” pitch fiberglass/gelcoat roof with a skid extension for mounted generator Field applied brick in a staggered brick pattern with a shingled, hip roof Specifications The Frame At EFI, only the best materials are used to construct the building. Galvanized, steel studs, joists, and channels are used in the building framework. Optional wood framing is available. Custom Designed, Factory-Built Modular Structures Wall studs are 3-5/8” 20 gauge steel or 6” 20 gauge steel placed a maximum of 16” on center. Roof joists, placed 16” center, are minimum 8”, 16 gauge steel. All of the openings in walls or roof are fully framed. The Walls Our walls are constructed by applying 3/4” exterior grade plywood to the inside of the wall framing. The plywood is nailed and screwed to the framing. Fiberglass Reinforced Plastic (FRP) pebble grain sheeting is glued to the entire interior wall and ceiling surface. Seam and corner moldings are used to finish the joints. Two part spray polyurethane insulation is applied in the wall cavaties forming an airtight seal. 1/2” exterior grade plywood is applied to the outside of the framing. No OSB or particle board is used in EFI construction. By Enclosures For Industry The Ceiling The ceiling of our EFI buildings are made the same as the walls. The roofing insulation has an R-28 value, and the roof can be flat or pitched. Ceiling joists are rated for various live and dead loads based on the site requirements and building use. The Floor In most applications, the floor is 1/4” steel plate on a structural steel frame. The entire floor and substructure is grit blasted and coated with two-part epoxy to a .008’ DFT. Exterior Finish The standard exterior finish is 3/16” fiberglass coating over all exterior surfaces, walls and roof. The roof and sidewalls have fiberglass applied from the outside to form a seamless exterior surface. Once the exterior surface has dried, a UV resistant gelcoat is applied. Multiple finish styles, colors and textures are available. Many other exterior finishes are available, vinyl, masonry, cement boards, etc. The Roof EFI buildings come standard with a fiberglass roof with a 1/2” :12” pitch. Optional roof structures and coverings are available including: - Shingled Roof, Fiberglass or Steel - Metal Standing Seam Roof - Roof Hatches - Trussed Roof System - Hip or Gable - Flat Roof for Field Installed Roof Structure The Doors and Hardware Single or double, aluminum or steel doors are provided flush or outset frames with lock sets, panic hardware, doors, windows and other options. Overhead doors are also an option Design Criteria - Minimum Design Loads for Buildings and Other Structures - ASCE 7-05 American Society of Civil Engineers - 2006 International Building Code - 2008 National Electrical Code R R - AISI - Standard for Cole-Formed Steel Framing General Provisions - Specific State Certifications/Approvals Are Available - AISI - Specification for the Design of Cold-Formed Steel Structural Members; 1996 Engineered Fluid, Inc. I F E y l On PO Box 723, Centralia, IL 62801 (618) 533-1351 Fax (618) 533-1459 www.engineeredfluid.com or [email protected] Multiple Compartments in One Building Double and Triple Connected Buildings Single Building Size up to 15 Ft x 52 Ft Placement on Slab or Foundation Wall With or Without Floors Code Constructed Electrical and Mechanical System Outfitted Various Exterior Finishes Various Roof Shapes and Materials
© Copyright 2024 ExpyDoc