Series 100 Pen D13 Tile Hook with Flat Tile

NOTES:
REVISION:
- 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURAL MEMBERS / RAFTERS
5
SNAPNRACK
STANDARD RAIL
- TORQUE ALL 16" HARDWARE TO THE FOLLOWING:
- SILVER S.S. 10-16 FT-LBS
- BLACK S.S. 7-9 FT-LBS
- RAILS CAN MOUNT TO EITHER SIDE OF TILE HOOK (UPSLOPE VS. DOWNSLOPE)
- RAILS CAN BE LEVELED UP TO 1.25" USING THE SLOT IN THE TILE HOOK
SNAPNRACK
STANDARD RAIL
5
16
SNAPNRACK
CHANNEL NUT
5
16
-18 X 1.25" STAINLESS BOLT
WITH SPLIT LOCK WASHER
SNAPNRACK
CHANNEL NUT
2 QTY.
5
16"
-18 X 1.25" STAINLESS
BOLT WITH SPLIT LOCK
WASHER
SNAPNRACK
TILE HOOK
5
2 QTY. 16" LAG BOLTS WITH
3
4"
WASHERS. ENSURE 2.5"
MINIMUM EMBEDMENT INTO
RAFTER
LAG BOLTS WITH
3
4"
WASHERS. ENSURE 2.5"
MINIMUM EMBEDMENT INTO
RAFTER
2.5" MINIMUM
EMBEDMENT
INTO RAFTER
SEAL PENETRATIONS
AND UNDER BASE
WITH APPROPRIATE
ROOF SEALANT
SNAPNRACK
TILE HOOK
SEAL PENETRATIONS
AND UNDER BASE
WITH APPROPRIATE
ROOF SEALANT
FLAT ROOF TILE, TYP.
ROOF DECKING,
TYP.
ROOF DECKING,
TYP.
RAFTER OR STRUCTURAL
ROOF MEMBER
RAFTER OR STRUCTURAL
ROOF MEMBER
MAINSTREAM ENERGY CORP.
775 FIERO LANE, SUITE 200 SAN LUIS OBISPO, CA 93401 USA
PHONE (805) 528-9705 FAX (805) 528-9701
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION,
DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF
MAINSTREAM ENERGY CORPORATION.
COMPLETED INSTALLATION
DESIGNER:
G McPheeters
DRAFTER:
D Ryan
SCALE:
DATE:
APPROVED BY:
DNS
PART NUMBER:
S100 PEN D13
120113
DESCRIPTION:
REV
PEN DETAIL 13, TILE HOOK WITH FLAT
TILE
F