General arrangement drawing, vacuum pump

1
2
3
4
5
6
7
OUTLET
8
NOZZLE TABLE
N2
INLET
N1
AIR INLET
ANSI150# 5'' RF slip-on
615, 190, 1396
N2
AIR OUTLET
ANSI150# 5'' RF slip-on
995, 410, 1445
N3
PRESSURE SAFETY VALVE
ANSI150# 5'' FF slip-on
665, -250, 813
N4
MANUAL DRAIN VALVE
1/2 '' NPT
665, 190, 815
N1
A
X, Y, Z-VALUES
Baseplate position holes tolerance 5mm
Connections tolerance 10mm
12
6
4
584
N4
CAUTION
NOTE 3
CABLE ENTRY
1x 1/2'' NPT
Always use flexible couplings when
connecting to rigid pipes.
Protect the machine at least with a
shielding
roof when installing in the open air.
N3
NOTE 4
9
7
1455
1445
B
Foresee a clear area of at least 1m
around the group in order to permit
the disassembly and the maintenance.
1406
CABLE ENTRIES
2x M32x1,5
1x M20x1,5
A
3
B
600
550
10
813
2
M16/M18, A2-70
823
CoG Z: 750
5
1m
11
C
C
1
8
1000
DATUM POINT
50
100
10
100
1200
25
1m
550
10
DATUM POINT
1m
1200
1000
13
25
600
1m
25
M22 x4
FOR LIFTING
1150
25
25
MAINTENANCE AREA
FOOT PRINT
SCALE 1:20
10
70
CENTER OF GRAVITY
X
665
COG COORDINATES
Y
Z
265
750
E
EXAMPLE OF THE EQUIPMENT SUPPORT
ARRANGEMENT IN ONE CORNER
SCALE 1:6
CoG X: 665
250
25
DATUM POINT
20
CUBILITY SCOPE
YARD SCOPE
190
850
410
220
335
550
CoG Y: 265
E
40
D
190
D
535
615
380
205
PLANT
NOTES:
F
Drawing number
Rev. Drawing number
DRW10227
Rev.
01 1
2
DRAWING TITLE:
F
GENERAL ARRANGEMENT
DRAWING, VACUUM PUMP UNIT
MUD CUBE
01 15-08-14
3
-
1. WEIGHT: 420 KG, NO ITEM >25KG ARE TO BE REMOVED
FOR MAINTENANCE
2. USED FOR MAINTENANCE PURPOSES ONLY AND TO
CHECK FOR MOISTURE IN THE FILTER
3. TO BE COVERED WITH SAFETY GUARD MESH ACC. TO
GRADE IP20
4. NO LOADS ARE ADMISSIBLE FOR INLET, OUTLET AND
VACUUM RELIEF FLANGE OF THE TBT. PIPING HAS TO BE
SUPPORTED AND EXPANSION JOINT HAVE TO BE
INSTALLED BETWEEN PIPING AND TBT-FLANGES.
5. SURFACE COATING AND PROTECTION ARE IN
COMPLIANCE WITH NORSOK M-501
REV.
4
DATE
5
ISSUED FOR INFORMATION
LKW
REASON FOR ISSUE
SU
KH
1:10
SCALE
6
AT
A3
D370
11
SIZE
AREA
SYSTEM
7
-
DRAWING NUMBER
8
REV.