Range TIME Wall hung condensing boilers ErP 2015 Ready Solar compatible 18 kW 27 kW 35 kW Time Comfort and energy saving 2 ErP 2015 Ready Italtherm Time boilers have been designed to meet the requirements set out by the new ERP (Energy Related Products) European regulation, that will come into force in 2015. Power modulation 1:10 Low NOx emissions (class 5) STAINLESS steel condensing exchanger High efficiency according to regulation 92/42/EEC Fully electronic modulation pump Intelligent electronic temperature control 3 Benefits of Italtherm condensing boiler Italtherm solution to maximise comfort and energy saving ITALTHERM’S NEW CONDENSING BOILERS, designed in compliance with the future ERP REGULATION, ARE THE IDEAL SOLUTION for anyone requiring A HIGH-EFFICIENCY CENTRAL HEATING SYSTEM, WITH THE POSSIBILITY OF DELIVERING LARGE AMOUNTS OF DOMESTIC HOT WATER. STRONG POINTS: 1 New combustion unit with 1:10 modulation Gas savings of up to 40%. The stainless steel condensing exchanger allows to recover the latent heat existing in the flue, considerably increasing the energy efficiency; the innovative mixer provides a wide modulation range, up to 1:10. Flue safety thermostat To protect the flue outlet system Special burner Optimised profile for perfect combustion at all power levels Primary exchanger vent valve Built-in Mixer It allows modulation up to 1:10 2 Fully electronic modulation pump Energy savings of up to 50% The fully electronic modulation pump optimises the pump power absorption according to the system heat demand, improving even considerably the overall efficiency of the thermal module. 4 Main exchanger Stainless steel 3 New hydraulic unit Maxi insulated DHW exchanger (K models only) • 22 plates for the model 27 K Transducer and gouge of CH system pressure • 28 plates for the model 35 K • Indication of water pressure on the display DHW flow switch • DHW flow rate available on the display • Optimal flame’s modulation • Analogic indication in case of power supply’s loss Draining tap Easy to be gained DHW probe Immersion probe DHW inlet filter By-pass Filling electrovalve manual / automatic with in-built check valve and filter 4 Inspection from the front nut • Adjustable and can be excluded Flow regulator DHW flow adjustable • Outside the DHW exchanger for prevent scale appearance ACQUA STEP (K model) and SPA (KR model) functions For maximum DHW comfort The Acqua Step function can be used to pre-heat the water in the maxi heat exchanger so that hot water is always available. It can be programmed on a daily or weekly basis, with three different temperature settings. The SPA function heats the tank to the maximum temperature for 1 hour, to deliver unrivalled DHW comfort. 5 Control panel The control panel, featuring simple, intuitive commands, is used to control all the main boiler and system functions, including the management of solar panels if present and/or management of mixed low and high temperature systems. Practical + and – buttons for heating temperature selection Large and comprehensive display Info button, providing direct access to all the current operation information Practical + and – buttons for domestic hot water temperature selection Clock button for DHW Schedule selection RESET button for fault reset on/off and operating mode selection button Plus button to activate the ACQUA STEP function (K model) or the quick tank heating function and SPA function (KR model) * the availability or functionality of the controls and DHW temperatures depend on the presence of the relative system components, outside the boiler. 5 Time K Central heating and domestic hot water 27 K 35 K 6 Time 27 K, 35 K Condensing boilers for central ErP 2015 Ready heating and instantaneous supply of DHW with maxi heat exchanger The use of condensing technology, the Solar compatible innovative mixer, the new improved burner for perfect combustion at all power outputs, the fully electronic modulating circulating pump and 1:10 modulation mean that these boilers boilers approved by guarantee particularly high performance across all operating ranges. Main features •ACQUA STEP DHW pre-heating function with three different programmable temperatures •Insulated stainless steel DHW maxi exchanger •Easy-to-remove water inlet filter •DHW flow detector for optimised modulation •Power modulation 1:10 •Pump with high efficiency fully electronic modulation (ERP ready) •External by-pass, can be excluded •Analogue and digital indication of heating circuit pressure •Automatic system filling •Can be installed indoors or in a partially protected place outdoors (temperature 0÷60°C) •Pre-engineered for remote control •Dual temperature control, ideal for mixed systems •Multi-function backlit LCD display •Protection rating IP X5D •Brass hydraulic unit •“Holiday program” function D.H.W. at ∆T 25°C Code (Methane/G31*) WxHxD (mm) Weight (kg) El.pow. (W) Qn/Qmin (kW) η at Qn (%) ** η at 30% Qn (%) ** Time 27 K 301001104 MET 301003105 G31 450 x 41.6 110 26/2.6 104.7 107.6 14.4 Time 35 K 301001106 MET 301003107 G31 43.5 118 33/3.4 105.1 107.6 18.4 Model 837 x 382 l/min Legend: W x H x D = width x height x depth • El.pow. = maximum absorbed electric power • Qn/Qmin = maximum/minimum rated heat intput η = efficiency • D.H.W. = supply of Domestic Hot Water. * LPG supply is only available using G31 Commercial Propane (containing no G30 Butane). ** With boiler running in condensing mode (delivery 50°C; return 30°C). 7 Time Kr Central heating with external storage 18 KR 27 KR 35 KR 8 Time 18 KR, 27 KR, 35 KR Condensing boilers for CH, DHW ErP 2015 Ready production by external storage The use of condensing technology, the innovative mixer, the new improved burner for Solar compatible perfect combustion at all power outputs, the fully electronic modulating circulating pump and a modulation ratio of 1:10 mean that these boilers guarantee particularly high performance across boilers approved by all operating ranges. Main features •DHW tank timer •Easy-to-remove water inlet filter •Power modulation ratio 1:10 •Pump with high efficiency fully electronic modulation (ERP ready) •External by-pass, can be excluded •Three-way electrical valve in the boiler •Direct management of the solar panel system using the additional card (optional) •Can be installed indoors or in a partially protected place outdoors (temperature 0÷60°C) Model Code (Methane/G31*) Time 18 KR 301001110 MET* Time 27 KR 301001112 MET 301003113 G31 Time 35 KR 301001114 MET 301003115 G31 WxHxD (mm) 450 x 837 x 382 •Analogue and digital indication of heating circuit pressure •Pre-engineered for remote control •Dual temperature control, ideal for mixed systems •Multi-function backlit LCD display •Automatic system filling •“Holiday program” and “SPA” function •Protection rating IP X5D •Brass hydraulic unit Weight (kg) El.pow. (W) Qn/Qmin (kW) η at Qn (%) ** η at 30% Qn (%) ** 38.0 105 17.8/1.7 105.6 107.5 39.6 110 26/2.6 104.7 107.6 41.5 118 33/3.4 105.1 107.6 Legend: W x H x D = width x height x depth • El.pow. = maximum absorbed electric power • Qn/Qmin = maximum/minimum rated heat intput η = efficiency * LPG supply is only available using G31 Commercial Propane (containing no G30 Butane). ** With boiler running in condensing mode (delivery 50°C; return 30°C). 9 Accessories Description Code Hydraulic fitting kit This contains the quick hydraulic fittings for connecting the boiler to the system. It comprises: 1 gas cock compliant with legal requirements; 1 water cock; 5 pipes (6 for the Kr model) for the gas, DHW and CH system hydraulic couplings; appropriate fittings. All components, on the boiler side, are push-fit couplings and are complete with hexagonal swivel collars (swivel nuts) and the corresponding seals. Re-usable template (in galvanised sheet metal) This allows the installer to position the wall-hung hydraulic fittings in exactly the right place 401010015 401010016 401020009 401020010 Kit for high + low temperature systems This kit allows an Italtherm condensing boiler to manage a low and high temperature CH system. When the request is from low temperature areas only, the condensing boiler runs in low temperature mode. When there are mixed requests from both circuits, the boiler runs in high temperature mode and the flow to the low temperature system is managed by the kit, by mixing the return low temperature circuit flow with part of the high temperature circuit flow 401100001 Remote control with climate regulator The remote control: optimises boiler operation, interfacing with the relevant electronics. It includes a comprehensive weekly climatic regulator, easy to set-up and user-friendly. It replicates all the boiler controls and provides Technicians with diagnostic information and additional functions. Easy to install, it replaces the Room Thermostat. It is powered by the boiler at very low voltage, therefore no batteries are required. 401080001 Weekly scheduling digital chronothermostat Weekly programming with 3 temperature levels. Available in 3 versions: • Wired connection version code 401080002 it is connected to the boiler Room Thermostat line. • GSM version code 401080004 Turn heating on and off with a phone ring! Also send an SMS to remotely manage heating and receive an SMS in case of fault. • RF version code 401080005 No cables or troughs are required to connect it to the boiler. The supply includes the radio receiver for the boiler. 401080002 401080004 401080005 CH multi zones interface PCB The Kit allows to manage the heating of the main zone controlled by the remote control and of other additional secondary zones, through room thermostats and zone solenoid valves. 401110001 Outdoor temperature sensor This kit lets the heating system run in “flow temperature” mode; that means the delivery temperature will vary automatically according to the outside temperature (measured by the temperature sensor) and to the “coefficient of dispersion” of the building. 10 401060001 Flue systems TIME supports multiple flue configurations: C43 C53 C83 C93 C13 coaxial systems C33 Example of vertical (C33) and horizontal (C13) coaxial systems 00047 00 Example of split pipes system (C43 / C83) SC 00046 00 LCV AS Ø80 Ø60 Ø80 Ø60 1300 split pipes systems* Ø125 LCO Ø100 /Ø60 Ø100 135 /Ø60 127 Mod. 127 (Ø80) 197 (Ø60)** 00049 00 153 (Ø80) 223 (Ø60) ** Genuine*** Ø80mm split system AS+SC min÷max (m) SC max (m) 18 KR 2 ÷ 51 50 27 K/KR 2 ÷ 51 35 K/KR 2 ÷ 51 Mod. Genuine*** Ø60/100 mm coaxial system LCO min÷max (m) LCV min÷max (m) 18 KR 1÷8 1 ÷ 10 50 27 K/KR 1÷8 1 ÷ 10 50 35 K/KR 1÷8 1 ÷ 10 Genuine*** Ø60mm split system 18 KR 2 ÷ 11 10 27 K/KR 2 ÷ 11 10 35 K/KR 2 ÷ 11 10 * Remark: Split pipes allow to make also C13 and C33 flue systems. ** The dimensions on the duct axis are referred to the upper edge of the boiler’s body, close to the mouth of the first 90° bend. The difference of level due to the slopes are not considered. *** IMPORTANT: the table refers to genuine flue accessories. If you use any NON-genuine flue accessories (certified for condensation, whose use is allowed by the boiler’s C6‑type certification) please refer to the relevant technical documents.. 11 Pump heads Time 27 K - 35 K ERP ready electronic variable speed pump 7 00236 00 6 27K 5 pressure (m H2O) pressure (m H2O) (The graph is referred to the head available to the system) 7 00149 02 6 35K 5 4 4 3 3 2 MIN by-pass auto 1 MAX MAX 2 by-pass closed MIN by-pass auto 1 by-pass closed 0 0 0 200 400 600 800 1000 1200 0 1400 200 400 600 800 1000 1200 1400 flow (l/h) flow (l/h) Nota: the diagram MAX is referred to the maximum working power of the pump, the diagram MIN depends on electronics. The pump is continuous electronic modulation type and therefore it can work on any point between them. Time 18 KR - 27 KR - 35 KR ERP ready electronic variable speed pump In each diagram, the correct and incorrect working range for the boiler-storage system, is shown. We recommend to avoid a flow below 850 litres per hour because, if so, the production of hot water could require longer time. pressure (m H2O) (The graph is referred to the head available to the system) 7 00235 A 00 6 18KR 5 4 3 MAX 2 Nota: the diagram MAX is referred to the maximum working power of the pump, the diagram MIN depends on electronics. The pump is continuous electronic modulation type and therefore it can work on any point between them. MIN by-pass auto 1 by-pass closed 0 0 200 400 600 800 1000 1200 1400 7 00236 A 00 6 27KR 5 pressure (m H2O) pressure (m H2O) flow (l/h) 7 6 4 3 3 MIN by-pass auto 1 MAX 400 600 800 1000 1200 1400 flow (l/h) 12 MIN by-pass auto 1 by-pass closed 200 MAX 2 0 0 35KR 5 4 2 00149 A 02 by-pass closed 0 0 200 400 600 800 1000 1200 1400 flow (l/h) Dimensions Time 27 K - 35 K 382 382 232 218 120 3 2 2 1 3 120 36 382 382 36 front view - 36 00140 0000140 00 14 20 left side view hydraulic connections on the boiler 837 837 77 77 3 770 770 hydraulic connections on the boiler M C M C 3 20 TA 33 35 L M C G F 33 35 TA RL M SC C G F 77 65 83 83 65 R 77 SC = = 77 65 83 83 65 77 218 =232 = 20 36 20 front view hydraulic connections on the wall (with optional fitting kit) 20 SC 65 SC = 65 = G G F 83 F 83 83 83 TA / L TA / L 65 = 65 = R R 77 77 G MCR G 175 M CR 197 175 197 F F 154 154 223 223 793 793 450 20 14 450 1 Legend: 1Flue outlet upper view (modd. K) 2Air inlet for coaxial system 3Air inlet for split-pipe system GGas: connection on the boiler (¾”); on the wall, using the optional original fitting kit (½”) RSystem return (¾”) MSystem flow (¾”) CHot water outlet (½”) FFresh water inlet (½”) TA/L Indicative position for electrical power supply and room thermostat wirings TARoom thermostat wiring LElectrical power supply wiring SCIndicative position for the condensate drain 13 Dimensions Time 18 KR - 27 KR - 35 KR 36 20 8 382 382 3 2 2 upper view 1 1 3 120 382 20 left side view hydraulic connections on the boiler 837 RB TA / L 837 MB F G 3 8 M R 3 MB F G TA / L MSC RB 75 50 50 50 83 65 R 77 = = SC 75 50 50 50 83 65 77 = = 8 20 770 770 00141 00 front view hydraulic connections 36 36 on the boiler 20 TA 33 35 L M G RB R TA 33 35 L SC MB F 75 M50 50 50 G83 RB65 77 = = R SC 75 5023250 50 83 218 65 77 = = 120 232 218 MB F 36 MB F M RB R G MB F 175 M RB R G 175 154 154 223 223 front view hydraulic connections on the wall (with optional fitting kit) 8 793 793 450 382 20 00141 00 14 20 14 450 Legend: 1Flue outlet 2Air inlet for coaxial system 3Air inlet for split-pipe system (modd. KR) GGas: connection on the boiler (¾”); on the wall, using the optional original fitting kit (½”) RSystem return (¾”) MSystem flow (¾”) FFresh water inlet (½”) RBReturn from storage coil (¾”) MBFlow to storage coil (¾”) TA/L Indicative position for electrical power supply and room thermostat wirings TARoom thermostat wiring LElectrical power supply wiring SCIndicative position for the condensate drain 14 Technical data Description CE certification Category Type Operating temperature (min÷max) Reference Gas Max heat input Min heat input Max heat output 60°/80°C Min heat output 60°/80°C Max heat output 30°/50°C Min heat output 30°/50°C NOx Class Corrected CO at 0% O2 (Qn) CO2 at Qn Flue temperature (Qn) Flue mass flow rate (at 60/80°C and at Qn) u. m. Time 27 K Time 35 K Time 18 KR Time 27 KR Time 35 KR 0694 CM 3400 II2H3P B23 - B23P - C13 - C33 - C43 - C53 - C63 - C83 - C93 0 ÷ +60 G20 °C kW kW kW kW kW kW 26.0 2.6 25.1 2.4 27.2 2.7 33.0 3.4 32.0 3.1 34.7 3.4 26.0 2.6 25.1 2.4 27.2 2.7 33.0 3.4 32.0 3.1 34.7 3.4 176.1 9.3 78.6 53.0 17.8 1.7 17.1 1.6 18.8 1.8 5 176.8 9.2 83.0 28.9 ppm % °C kg/h 165.3 9.2 84.0 42.2 165.3 9.2 84.0 42.2 176.1 9.3 78.6 53.0 % % % % 96.6 100.8 104.7 107.6 97.0 101.2 105.1 107.6 96.2 100.7 105.6 107.5 96.6 100.8 104.7 107.6 97.0 101.2 105.1 107.6 EFFICIENCY Nominal efficiency at 60°/80°C Efficiency at 30% load at 60°/80°C Nominal efficiency at 30°/50°C Efficiency at 30% load at 30°/50°C HEATING High/low temperature selection range (min÷max) Sec. zone temperature selection range (min÷max) Expansion vessel Expansion vessel pressure Max operating pressure Max system temperature °C °C l bar bar °C 30÷80 / 25÷45 25÷80 10 1 3 85 DOMESTIC HOT WATER Flow rate at 25°C temperature rise Flow rate at 30°C temperature rise Min water flow (for DHW request activation) Min supply pressure (for DHW request activation) Max supply pressure (boiler only) Temperature selection range (min÷max) l/min l/min l/min bar bar °C 14.4 12.0 1.5 0.5 6 30÷55 18.4 15.3 1.5 0.5 6 30÷55 — — — — 6 30÷60 — — — — 6 30÷60 — — — — 6 30÷60 110 IP X5D 118 IP X5D 220÷240 / 50 (230V) 105 IP X5D 110 IP X5D 118 IP X5D 41.6 43.5 450 x 837 x 382 38.0 39.6 41.5 2.75 0.27 3.49 0.36 ELECTRICAL CHARACTERISTICS Voltage / frequency (nominal voltage) Power consumption Degree of protection V/Hz W DIMENSIONS Width - Height - Depth Weight mm kg CONNECTIONS Hydraulic and gas connections Coaxial inlet/outlet pipe diameter Min ÷ max length of coaxial inlet/outlet system Split inlet and outlet pipes diameter Min ÷ max length of split system Fan head loss mm m mm m Pa See page 10 100/60 See page 11 80 o 60 See page 11 30 ÷ 130 mbar mbar 20 17 ÷ 25 GAS SUPPLY PRESSURES Nominal pressure Inlet pressure (min÷max) GAS CONSUMPTION Qmax Qmin m³/h m³/h 2.75 0.27 3.49 0.36 1.88 0.18 15 987000011 rev. 05 09/12/2014 ITALTHERM Srl Via S. D’Acquisto, 10 • 29010 Pontenure (PC) - IT Tel. (+39) 0523.575611 • Fax (+39) 0523.575600 www.italtherm.it • e-mail: [email protected] Corporate Video All data contained in this document must be considered indicative and not binding. ITALTHERM reserves all the rights to modify the contents without any notice. www.italtherm.it
© Copyright 2025 ExpyDoc