Trust this warmth... touch for eco-friendly heating... 4-pass Construction Solid Fuel Manual Loading Flue Gas Measure Point (Optional) 16 kW - 93 kW fuel saving I N V E RTER BOILER 0,6 kg hour fuel saving 864 kg annual fuel saving NOTE: Inverter is optional. 1 www.termodinamik.com.tr 4 pass solid fuel boilers of EKY series are produced in 6 different heating capacities. EKY boiles are outstanding with its easy operation, high efficiency and long life due to thickness of materials applied to production. 4-pass structure allows to minimize harmful impact of the emission gases on the environment. Optionally it's possible to install additional water heater (boiler) for use hot water supply. Electronic control panel ensures control over the operation of the boiler at any stage. Circulation Pump (for EKY 17-25-40-60 models): Three-speed circulation pump of wet motor type. Operates very silently. Special shaft and stainless steel closed type rotor prevent blockage in the pump. Three-speed motor, which provides energy save, ensures full matching of the pump to the system and removes the hydraulic noise. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the EKY boilers and contributes to the long life of the boiler. Flue Damper: EKY boilers are equipped with flue damper in order to achieve fuel saving for high draught flues. It can be adjusted easily by the user due to its position visible from outside. Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Fuel Warning: Unnecessary fan operation is prevented by run-out-of-fuel indicator on the electronic panel. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed to prevent smoke’s escape. L øG E J H Watered Pipe (EKY 17): The temperature of flue gas conveys to the water of boiler In smoke box. F J H H By this means, the exhaust gas is temperature less in the chimney and the efficiency of boiler will increase. This boiler will be getting more heat with less fuel. J L C A C D B D EKY 25-100 Side View EKY 17-100 Front View EKY 17 Side View Capacity (Pellet) Kw EKY 17 Test Operating Pressure Pressure (bar) (bar) 16 23 37 56 75 93 Water Volume 60 95 115 156 170 180 Weight kg 183 255 300 420 450 470 G Flue Fuel Loading L (Boiler J (Safety H (Boiler Diameter Filling-Discharge) Input-Output) Lid Dimensions Input-Output) (mm) (mm) EKY 17 715 715 715 890 890 890 560 820 1100 1225 130 190x390 We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 2 Solid Fuel 4-pass Construction Manual Loading 23 kW NEW PRODUCT AU T O NITION M ATIC IG Resistance type automatic ignition is applied to the boilers. The resistance increases temperature with the help of electrical energy. This heat energy is transmitted from resistance to fuel by the air generated by the fan. Automatic ignition feature is optional. 3 www.termodinamik.com.tr Pellet boiler which is a solid-fired boiler that can use pellet and wood chip as fuel has three passes. Design of the pellet boiler is made by taking into considerations for the aim that is maximum boiler efficieny . Steel material thicknesses of the pellet boilers’s are more than the other pellet boilers. This provides long lifetime for users. In addition, It is easy to use and has high efficieny value. Pellet boiler is a full-automatic boiler and contains automatic feeding system, automatic ignition system, automatic ash-removal system and automatic tube cleaning system. These system are optional. An forced draft fan is used in the pellet boiler. This prevents smoking from covers of boiler or fuel tank. High-technology control panel can be used easily and can control all of the components very effectively. Circulation Pump: Three-speed circulation pump of wet motor type. Operates very silently. Special shaft and stainless steel closed type rotor prevent blockage in the pump. Three-speed motor, which provides energy save, ensures full matching of the pump to the system and removes the hydraulic noise. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the pellet boilers and contributes to the long life of the boiler. Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Fuel Sensor (optional): By means of a sensor placed in the bunker, when fuel decrease, the boiler stops feeding and electronic panel gives warning. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed to prevent smoke’s escape. Adjusting Fuel Feeding Time: Fuel feeding regulation is made by two buttons on the control panel. One button sets the waiting F H B D J G L E A Capacity Operating Test (pellet) Pressure Pressure (bar) (bar) kW 25.000 23 4.5 C F Flue Diameter (mm) 715 560 815 1100 130 G Heating H Heating Input (mm) Output(mm) J Safety Input-Output (mm) L Discharge Pipe 130 We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 4 Solid Fuel 4-pass Construction Automatic Loading Round Oven Flue Gas Measure Point (Optional) Fuel Sensor (Optional) 16 kW - 93 kW AU T O NITION M ATIC IG Resistance type automatic ignition is applied to the boilers. The resistance increases temperature with the help of electrical energy. This heat energy is transmitted from resistance to fuel by the air generated by the fan. Automatic ignition feature is optional. fuel saving I N V E RTER BOILER 0,6 kg hour fuel saving 864 kg annual fuel saving NOTE: Inverter is optional. 5 www.termodinamik.com.tr Circulation Pump (for EKY/S 17-25-40-60 models):Three-speed circulation pump of wet motor type. Operates very silently. Special shaft and stainless steel closed type rotor prevent blockage in the pump. Three-speed motor, which provides energy save, ensures full matching of the pump to the system and removes the hydraulic noise. Burner: Combining and implementing burning conditions of different fuels; newly designed oven is capable to burn different solid fuels without oven replacement and modification. Manual Loading (Optional): Automatic feeding boilers additionally can be equipped with removable grille to burn firewood in manual mode. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the EKY/S boilers and contributes to the long life of the boiler. Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Fuel Warning: Unnecessary fan operation is prevented by run-out-of-fuel indicator on the electronic panel. Fuel Sensor (optional): By means of a sensor placed in the bunker, when fuel decrease, the boiler stops feeding and electronic panel gives warning. Watered Pipe (EKY 17): The temperature of flue gas conveys to the water of boiler In smoke box. By this means, the exhaust gas is temperature less in the chimney and the efficiency of boiler will increase. This boiler will be getting more heat with less fuel. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed F to prevent smoke’s escape. J J J G G H H C C EKY/S 17 Side View EKY/S 25-100 Side View Capacity (Pellet) Kw EKY/S 17 16 МODEL EKY/S 25 23 37 EKY/S 40 EKY/S 60 56 EKY/S 80 75 93 EKY/S 100 Model EKY/S 17 EKY/S 25 EKY/S 40 EKY/S 60 EKY/S 80 EKY/S 100 B K E E Model 120 øD øD A J F Fuel Tank Capacity (Pellet) Fuel Loading Lid Dimensions (mm) 82 kg 82 kg 82 kg 122 kg 122 kg 122 kg 310 x 590 310 x 590 310 x 590 360 x 640 360 x 640 360 x 640 K (mm) A B C ØD (mm) ØE (mm) (mm) (mm) (mm) Flue Cover is Open 1095 940 560 1125 940 635 1125 940 835 1235 1085 985 1235 1165 1060 1235 1165 1060 130 200 200 200 200 200 1335 1440 1600 1900 2000 2000 K (mm) Shaft Removal Distance 1445 1640 1640 1800 2030 2020 We are reserved the right to make changes in dimensions and appearance. EKY/S 17-100 Front View Water Test Operating Volume Weight Pressure Pressure kg (bar) (bar) 60 95 115 156 170 180 210 288 334 456 494 503 F (Heating G (Heating Input) Output) R1˝ R1˝ R1˝ R1 1/4˝ R1 1/2˝ R1 1/2˝ R1˝ R1˝ R1˝ R1 1/4˝ R1 1/2˝ R1 1/2˝ 3 3 3 3 3 3 4.5 4.5 4.5 4.5 4.5 4.5 H (Filling Discharge Output) R 1/2˝ R 1/2˝ R 1/2˝ R 1/2˝ R 3/4˝ R 3/4˝ J (Safety Input-Output) R 3/4˝ R 3/4˝ R1˝ R1˝ R1 1/4˝ R1 1/4˝ www.termodinamik.com.tr 6 Solid Fuel 4-pass Construction Manual Loading Flue Gas Measure Point (Optional) 23 kW - 93 kW fuel saving I N V E RTER BOILER 0,6 kg hour fuel saving 864 kg annual fuel saving NOTE: Inverter is optional. 7 www.termodinamik.com.tr 4 pass solid fuel boilers of TBK series are produced in 5 different heating capacities. TBK boiles are outstanding with its easy operation, high efficiency and long life due to thickness of materials applied to production. 4-pass structure allows to minimize harmful impact of the emission gases on the environment. Optionally it's possible to install additional water heater (boiler) for use hot water supply. Electronic control panel ensures control over the operation of the boiler at any stage. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the TBK boilers and contributes to the long life of the boiler. Fuel Warnings: TBK boiler prevents unnecessary operation of the fan indicating the burnout due to equipment displaying out-of-fuel warning on the control panel. Flue Damper: TBK boilers are equipped with flue damper in order to achieve fuel saving for high draught flues. It can be adjusted easily by the user due to its position visible from outside. Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed to prevent smoke’s escape. Safety Input( J) Input ( H) G Safety Output H N F Filling Discharge E J S P R I M C Heating Output A B D Model TBK 25 TBK 40 TBK 60 TBK 80 TBK 100 Flue Pipe Capacity A B C D E F GDiameter H (Boiler (Pellet) (mm) (mm) (mm) (mm) (mm) (mm) Input-Output) (mm) Kw 23 37 56 75 93 625 870 600 1080 625 870 600 1080 705 1020 850 1370 750 1070 950 1470 800 1120 1100 1615 Model L (Boiler Filling Discharge) J (Safety Input-Output) TBK 25 TBK 40 TBK 60 TBK 80 TBK 100 R 1/2˝ R 1/2˝ R 1/2˝ R 1/2˝ R 3/4˝ R 3/4˝ R1˝ R1˝ R1 1/4˝ R1 1/4˝ Grille Grille Depth M Length N (mm) (mm) 468 468 745 845 995 320 420 434 434 390 1270 1370 1490 1490 1490 1410 1510 1635 1655 1635 Grille Width P (mm) Door Width R (mm) 440 440 490 550 590 470 470 520 570 620 R1˝ R1˝ R1 1/4˝ R1 1/2˝ R1 1/2˝ 200 200 200 200 200 Door Operating Test Length S Pressure Pressure (bar) (bar) (mm) 330 330 350 350 350 3 3 3 3 3 4.5 4.5 4.5 4.5 4.5 Weight kg 250.5 259.5 405 430 465 We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 8 Solid Fuel 4-pass Construction Fuel Sensor (Optional) Manual Loading Watered Grill Flue Gas Measure Point (Optional) 23 kW - 93 kW NEW PRODUCT AU T O NITION M ATIC IG Resistance type automatic ignition is applied to the boilers. The resistance increases temperature with the help of electrical energy. This heat energy is transmitted from resistance to fuel by the air generated by the fan. Automatic ignition feature is optional. fuel saving I N V E RTER BOILER 0,6 kg hour fuel saving 864 kg annual fuel saving NOTE: Inverter is optional. 9 www.termodinamik.com.tr 4 pass solid fuel boilers of TBK series are produced in 5 different heating capacities. TBK/S boiles are outstanding with its easy operation, high efficiency and long life due to thickness of materials applied to production. 4-pass structure allows to minimize harmful impact of the emission gases on the environment. Optionally it's possible to install additional water heater (boiler) for use hot water supply. Electronic control panel ensures control over the operation of the boiler at any stage. Circulation Pump (for TBK/S 17-25-40-60 models):Three-speed circulation pump of wet motor type. Operates very silently. Special shaft and stainless steel closed type rotor prevent blockage in the pump. Three-speed motor, which provides energy save, ensures full matching of the pump to the system and removes the hydraulic noise. Adjusting Fuel Feeding Time: Fuel feeding regulation is made by two buttons on the control panel. One button sets the waiting Manual Loading (Optional): Automatic feeding boilers additionally can be equipped with removable grille to burn firewood in manual mode. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the EKY/S boilers and contributes to the long life of the boiler. Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Fuel Warning: Unnecessary fan operation is prevented by run-out-of-fuel indicator on the electronic panel. Fuel Sensor (optional): By means of a sensor placed in the bunker, when fuel decrease, the boiler stops feeding and electronic panel gives warning. Watered Grill: TBK/S boilers can burn coal, pellet and pomace. With grill pipes, it can also be burned wood. TBK/S boilers can work as both automatic and manual feeding. As boiler water passes throught boiler pipes, strength of the pipes, boiler efficiency and capacity increase. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed to prevent smoke’s escape. Model TBK/S 25 TBK/S 40 TBK/S 60 TBK/S 80 TBK/S 100 Model TBK/S 25 TBK/S 40 TBK/S 60 TBK/S 80 TBK/S 100 H G L J H L K C F D Fuel Loading Flue Pipe Capacity A B C D E F K GDiameter H (Boiler Lid Dimensions (Pellet) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Input-Output) (mm) (mm) Kw 23 520 520 37 642 56 75 642 642 93 L (Boiler Filling Discharge) R 1/2˝ R 1/2˝ R 1/2˝ R 3/4˝ R 3/4˝ 965 965 1130 1130 1130 635 835 935 1010 1010 1565 1765 1913 1990 1990 J (Safety Input-Output) R 3/4˝ R1˝ R1˝ R1 1/4˝ R1 1/4˝ 1252 1252 1410 1410 1410 1170 1360 1536 1610 1610 1645 1645 1870 1870 1870 Grille Grille Depth M Length N (mm) (mm) 530 730 830 905 905 180 180 230 230 230 200 200 200 200 200 R1˝ R1˝ R1 1/4˝ R1 1/2˝ R1 1/2˝ Grille Width P (mm) Fuel Tank Capacity (Coal) Fuel Tank Capacity (Pellet) 390 390 515 515 515 96 96 135 135 135 80 80 120 120 120 330 x 390 330 x 390 330 x 515 330 x 515 330 x 515 E Operating Test Pressure Pressure (bar) (bar) 3 3 3 3 3 4.5 4.5 4.5 4.5 4.5 A B We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 10 Solid Fuel 4-pass Construction Automatic Loading BACK SIDE FUEL TANK 23 kW - 37 kW AU T O NITION M ATIC IG Resistance type automatic ignition is applied to the boilers. The resistance increases temperature with the help of electrical energy. This heat energy is transmitted from resistance to fuel by the air generated by the fan. Automatic ignition feature is optional. fuel saving I N V E RTER BOILER 0,6 kg hour fuel saving 864 kg annual fuel saving NOTE: Inverter is optional. 11 www.termodinamik.com.tr Optionally it's possible to install additional water heater (boiler) for use hot water supply. 4 pass solid fuel boilers of EKY/S back side fuel tank series are produced in 2 different heating capacities. F 120 Circulation Pump: Three-speed circulation pump of wet motor type. Operates very silently. Special shaft and stainless steel closed type rotor prevent blockage in the pump. Three-speed motor, which provides energy save, ensures full matching of the pump to the system and removes the hydraulic noise. J A J G H Adjusting Fuel Feeding Time: Fuel feeding regulation is made by two buttons on the E control panel. One button sets the waiting time between fuel supply, another button sets the fuel feeding time. The values are adjusted with the help of digital screen. Due to this advantage, it’s possible to set the feeding time with desired accuracy. B Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the EKY boilers and contributes to the long life of the boiler. Electronic Control Panel: Electronic control panel ensures very simple and efficient operation of the EKY boilers and contributes to the long life of the boiler. C K Safety: The boiler water temperature is set with thermostat on the electronic control panel. In case of water temperature increase to 100 ˚C due to any reason, limit thermostat which can be reset manually engages and stops the operation of the fan. Fuel Warning: EKY/S boiler prevents unnecessary operation of the fan indicating the burnout due to equipment displaying out-of-fuel warning on the control panel. Flue Gas Measure Point (Optional): With Termodinamik new optional feature, flue gas value can be measured by means of a hole in the chimney. When measure is not conducted, the discharge of chimney is closed to prevent smoke’s escape. Model EKY/S 25 EKY/S 40 Model EKY/S 25 EKY/S 40 Capacity Fuel Tank Capacity (Pellet) Kw (Pellet) 23 37 82 kg 82 kg Water Weight A B C Volume (mm) (mm) (mm) kg (L) 95 288 115 334 K (mm) F (Heating Shaft Removal Output) Distance 2500 2670 R1˝ R1˝ 1125 1125 520 520 635 835 Ø (mm) E (mm) Flue Cover is Open 200 200 1430 1635 Operating J (Safety Pressure Input - Output) (bar) G (Heating Input) H (Filling Discharge) R1˝ R1˝ R 1/2˝ R 3/4˝ 3 R 1/2˝ R1˝ 3 Operating Test We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 12 Elegant Design High Efficiency www.termodinamik.com.tr 13 Panel surfaces, water channels and convectors of Termodinamik Panel Radiators are designed to ensure maximum heating. Panel Radiators occupy less space and has a beautiful appearance thanks to elegant design. For having high thermal power and efficiency, they heat the environment in the shortest time and provides fuel saving. Termodinamik panel radiators, with their height 300-400-500-600-900 mm and length from 400 mm to 3000 mm increasing in 100 mm ranges, ensure to choose the radiators with the most appropriate dimensions for the heating need and decorative design of the environment. For the purpose of preventing from shocks and healthy transportation, Termodinamik Panel Radiators are packed in carton box as supported with balloon and shrink nylon. TECHNICAL SPECIFICATIONS TYPE 22 PKKP HIGH H (mm) AXIS RANGE A (mm) DEPTH K (mm) HIGH OF CONVECTOR B (mm) WATER VOLUME L WEIGHT kg LENGTH L (mm) 300 250 72 200 3 15.50 400 - 3000 400 350 72 300 4 20.38 400 - 3000 500 450 72 400 5 25.23 400 - 3000 600 550 72 500 6 30.62 400 - 3000 900 850 72 800 9 45.13 400 - 3000 INSTALLATION TABLE HEIGHT H (mm) MENSOL DISTANCE C (mm) MENSOL TOP AND BOTTOM DISTANCE TO PANEL D-E (mm) CONSOLE WIDTH N (mm) MENSOL WIDTH F (mm) MENSOL WIDTH F (mm) MONTAGE HEIGHT P(mm) 300 93 91 33 - 45 25 50 Min 100 400 193 91 33 - 45 25 50 Min 100 500 218 128.5 33 - 45 25 50 .Min 100 600 318 128.5 33 - 45 25 50 Min 100 900 618 25 50 Min 100 128.5 45 Operating 33 -Test . We are reserved the right to make changes in dimensions and appearance. www.termodinamik.com.tr 14 Trust this warmth... TERMODİNAMİK MAK. SAN. ve TİC. A.Ş. Atatürk Mah. 80 sok. No:10 35170 Ulucak Kemalpaşa / İZMİR Tel: 0232 877 12 12 Faks: 0232 877 08 67 www.termodinamik.com.tr
© Copyright 2024 ExpyDoc