Data Centre Cooling Technologies 1 Jon Pettitt, EMEA DataCenter Business Development Manager Munters Group – Key facts • 3.000 Employees • Global DC Support • 30 Countries • 25+ Data Centers • Turnover of €470 M • 95 MW+ Cooling • HQ in Sweden • 455 Installed units • Founded1955 Munters – Your Perfect Climate 2 Global Manufacturing & Logistics Support Manufacturing plants Logistic & assembly hubs 16 Manufacturing Plants 5 Logistic & Assembly Hubs 53 Sales & Service Centres Munters Data Centre Installations to May 2013 • Challenges in DC Development no. 8 Key Challenges & Drivers Impacting the Data Centre Industry • Reliability/Uptime • SLA’s • Contamination • Energy Costs • Carbon Emissions • Modularity Air Contamination Infrastructure • Power Supplies • Data Centre size is often restricted by availability of power to site. • By reducing cooling power consumption, more power becomes available for critical processes and server operations. • Space • Land cost • Availability • Planning Consents • Water • Availability • Cost • Cooling Technologies no. 18 Indirect Evaporative Cooling no. 19 Oasis IEC Video Munters Oasis Final English.wmv video runs here Oasis Indirect Evaporative Cooler Using Polymer Tube HX Exhaust Outside 23°C 35°C Three Modes of Operation • Mode 1 – Cold Ambient – Operation:- DRY MODE – Air to Air Heat exchanger only • Mode 2 – Warm Ambient – Operation:- EVAP MODE – Indirect Evaporative Cooling only • Mode 3 – Very Warm/Hot Ambient (above approx 22°C WB) – Operation:- EVAP + DX MODE – Indirect Evaporative Air Cooling only + DX Cooling circuit Polymer Heat Exchanger ● Flexible Polymer Tubes ● 2.44 meters length ● 75-80% approach to outdoor scavenger air wet bulb temp ● 55% dry heat recovery • Scale Limiting design • Corrosion Resistant • Independently tested • UL 900 Class II • Flame retardant (UL94-V0) 14 Water Spray Operation Oasis wetted EPX Video no. 27 Beneath the Heat Exchanger 16 Legionella Risk Analysis • The Risk Assessment of the OASIS unit confirms that the risks of causing growth and spread of Legionella bacteria are negligible. • If the temperature is below 25°C, no risk of occurrence of Legionella in the system, which is the case most of the time. • In the operating conditions for water above 25°C, the system is designed so that water flows continuously in the circuit so that there is no stagnation of water and no risk of emergence of bacteria. • The Oasis IEC has an automatic emptying system that starts if installation is at standstill for agreed hours. Therefore no risk of proliferation of legionella in the water recovery pan. OASISTM IEC Range Oasis 100 < 100 kW 18.000m3/h 22.000m3/h Oasis 200 < 200 kW 36.000m3/h 44.000m3/h Oasis 300 < 310 kW 54.000m3/h 66.000m3/h 1 block 1 block 2 prefab blocks 6.9 x 1.4 x 3.6 / 9.4 m2 6.9 x 2.6 x 3.6 / 17.8m2 6.9 x 3.94 x 3.6 / 27.2m2 2.8 Ton 6.6 Ton 8.8 Ton • #5: Performance & Cost Comparisons no. 33 Section 5 Independent Performance Verification Oasis™ Indirect Evaporative Cooler Energy savings vs Chillers Oasis™ Indirect Evaporative Cooler Energy savings vs Chillers Results of Independent Engineering Review Benefits of Oasis™ IEC Cooling over high efficiency free-cooling chillers: • Lower capital costs • Reduced Infrastructure • 40% lower annual operating cost • Low partial PUE Source: Cundall Product Engineering Review. Based on 1MW data centre (N+1) Hours pa that Oasis IEC can provide 23°C without Mechanical Cooling Based on Hot Aisle return air temperature of 35DegC Hours run with EPX only Hours run with EPX and supplementary cooling Hours of operation per year Hours pa that Oasis IEC can provide 27°C without Mechanical Cooling Based on Hot Aisle return air temperature of 39DegC Hours run with EPX only Hours run with EPX and supplementary cooling Hours of operation per year Existing Installations no. 39 DCO2 Belgium – 5 MW ● Winner Datacenter Dynamics leadership award – 'Green Datacentre' 2011 & European Code of Conduct Award for new Data Centre 2011 ● With free cooling system: dust & pollution from surrounding farmland caused - Frequent replacement of filters - Required man power & frequent inspection - Caused pressure drop & increased fan power Solution: Munters Oasis Indirect Evaporative Cooler replaced full free cooling system DataInn, Lithuania – Oasis IEC key to advanced cost efficiency “Munters cooling solutions enable us to achieve an annual PUE of 1.3 or less, which will make us very cost-effective and competitive in the market. Every 0.01 reduction in our PUE represents an energy saving of approximately 210,000 kWh in our data centre.” • Secure, reliable data hall climate • Data centre air fully separated from outside air • 65% lower energy than common free cooling solutions • 25% reduction in refrigeration, switchgear, generator sets 28 Data Inn Development Manager Edvinas Bakanas, says: “The Lithuanian electric energy sector, data communication operators and biggest banks need their data to be safe and accessible without interruptions, as well as cost –effective and eco friendly. The high efficiency and innovative design were our main reasons for choosing Munters’ Oasis™ IEC” “The proven technology fits well with the climate conditions in Vilnius and offers a high degree of flexibility, operating in different cooling modes – depending on weather conditions.” DigiPlex Oslo – Largest Indirect Evaporative Cooled DC in Europe Energy efficiency of 1.12 PUE • • • • Annual pPUE of 1.06 Data centre air fully separated from outside Lower capital costs on refrigeration/switchgear 52 Oasis IEC 200’s Greg MCCulloch DigiPlex’s Chief Operating Officer: “Driving energy efficiency in our industry is a major focus for us and this system halves the amount of energy used to keep our servers working at an ideal temperature. This not only helps save our customers thousands of pounds in energy costs but also ensures that our facilities are amongst the most sustainable in the sector” 29 Australia T5 El Segundo, CA. Sabey Intergate Quincy no. 46 Sabey Case Study Oasis Sabey Quincy Video runs here 33 Data Centre Test Facility – Dison Belgium Benefits Oasis™ IEC Systems • Contamination Control • • • • Supply and outdoor airflow do not mix Corrosion Prevention: No added moisture/humidity to supply Usable for any kind of sweet water Rain water harvesting Eliminating DX cooling 100% IEC Cooling in some regions IEC efficiency can increase further As allowable supply air temperature to server inlet increases, Thank you Questions? no. 52
© Copyright 2024 ExpyDoc