EPIGAP Optronic GmbH Product Data Sheet PD UV EPD-150-0-2.5

EPIGAP Optronic GmbH
customized optoelectronics
Koepenicker Str. 325b, Haus 41
D-12555 Berlin
Fon: +49 (0)30 657637 60
Fax: +49 (0)30 657637 70
[email protected]
Product Data Sheet
PD UV
page 1 of 2
Rev. 01 aus 2011
EPD-150-0-2.5
Radiation
VUV
Type
Schottky Contact
Technology
GaP
Case
TO-39
Description:
Wide bandwidth and high sensitivity from VUV up
to the visible spectrum (150 nm - 550 nm),
mounted in hermetically sealed TO-39 package
with sapphire window
Application:
Medical engineering (dermatology), output check
of UV - lamps and oil or gas burner flame,
measurement and control of ecological
parameters, radiation control for a solarium, UV
water purification facilities
Maximum Ratings
Tamb= 25°C, unless otherwise specified
Parameter
Active area
Temperature coefficient of Iph
Symbol
Operating temperature range
Storage temperature range
Acceptance angle at 50% Sλ
Optical and Electrical Characteristics
Tamb= 25°C, unless otherwise specified
Parameter
1)
Breakdown voltage
Dark current
Peak sensitivity wavelength
Responsivity at λP
Sensitivity range at 1%
Spectral bandwidth at 50%
Shunt resistance
Noise equivalent power
Specific detectivity
Junction capacitance
Photo current at = 254nm1)
1)
Value
4.8
7.0
-40 to +125
-40 to +125
120
A
TC(IPh)
Tamb
Tstg
φ
Unit
mm2
%/ K
°C
°C
deg.
Unit
Test conditions
IR=10µA
VR=5V
VR=0V
VR=0V
VR=0V
VR=0V
VR=10mV
Symbol
VR
ID
λp
Sλ
λmin, λmax
∆λ0.5
RSH
λ = 440 nm
λ = 440 nm
NEP
D
1.3x10-14
1.7x1013
VR=0V
CJ
1000
pF
VR=0V
Ee=1mW/cm²
Iph
2.5
μA
Min
Typ
Max
15
440
0.13
40
5
0.1
150
80
550
180
100
V
pA
nm
A/W
nm
nm
GΩ
W/ Hz
cm ∙ Hz ∙ W
for information only
We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All
operating parameters must be validated for each customer application by the customer.
EPIGAP Optronic GmbH
customized optoelectronics
Koepenicker Str. 325b, Haus 41
D-12555 Berlin
Fon: +49 (0)30 657637 60
Fax: +49 (0)30 657637 70
[email protected]
Product Data Sheet
PD UV
EPD-150-0-2.5
page 2 of 2
Rev. 01 aus 2011
We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All
operating parameters must be validated for each customer application by the customer.