Savio Sun RP60 supplied by Bongioanni Caldaie S.r.l. Borgo San

Number
KIP-083601/01
Replaces
80537/01
Issued
25-06-2014
Scope
Expiry date
08-12-2018
Contract number
KIP TH 610
Report number
130902692
Page
1 of 1
EN 12975-1:2006 + A1:2010,
EN 12975-2:2006,
Solar Keymark Specific
Scheme Rules V21.00
Kiwa hereby declares that the thermal solar collector, type
Savio Sun RP60
supplied by
Bongioanni Caldaie S.r.l.
Borgo San Dalmazzo (CN), Italy
Is entitled to use the Solar Keymark label.
The compliance is based on examination to:
EN 12975-1:2006 + A1:2010, EN 12975-2:2006 and the
Specific Keymark Scheme Rules for Solar Thermal Products V21.00
A description of the test results is given in the appendix to this certificate.
Kiwa Italia S.p.a.
Sede Legale:
Via C. Goldoni, 1
20129 Milano
Sede Amministrativa e operativa:
Via Treviso, 32/34
31020 San Vendemiano (TV)
www.1kiwa.com
Bouke Meekma
Kiwa
034
Page 1/2
Flat plate collector - glazed
No
Yes
m²
Collector name
SavioSun RP60
2.26
Performance test method
Performance parameters related to aperture
Units
Test results - Flow rate and fluid see note 1
Bi-directional incidence angle
Incidence angle modifiers Kθ(θ)
Incidence angle modifier not bidirectional - leave fields blank
No
Angle
Kθ(θ)
Angle
Kθ(θL)
Gross
area (AG)
Collector Type (flat plate glazed/un-glazed; evacuate tubular)
Thermal / photo voltaic hybid collector? (PVT collector)
Integration in the roof possible ? (manufacturers declaration)
Gross
height
Country Italy
Website www.bongioannicaldaie.it
E-mail [email protected]
Tel/Fax
39 0171-687816
Gross
width
Company holding the
Bongioanni
Brand (optional)
Street, street number
Via Piave 14
Postal Code / City, province
12010 Borgo San Dalmazzo (CN)
Gross
length
Licence Number
Issued
Aperture
area (Aa)
Summary of EN 12975 Test Results,
annex to Solar KEYMARK Certificate
mm
2,290
mm
1,090
mm
105
m²
2.50
Power output per collector module
G = 1000 W/m²
Tm-Ta
0K
10 K
30 K
50 K
70 K
W
W
W
W
W
1,700 1,623 1,456 1,273 1,074
-
Glazed liquid heating collector - steady state - outdoor
η0
a1
a2
W/(m²K) W/(m²K²)
0.753
3.327 0.0091
0.200 0.000 0.000
10°
1.00
10°
1.00
CERTNO-80537/1
KIP-083601/01
2013-09-12
2014-06-25
1.000
Kθ values are obligatory for 50°.
30°
40°
50°
60°
70°
0.98
0.96
0.91
0.82
0.67
30°
40°
50°
60°
70°
0.98
0.97
0.94
0.90
0.81
20°
1.00
20°
0.99
80°
0.42
80°
0.52
Stagnation temperature - Weather conditions see note 2
Tstg
197
°C
Effective thermal capacity
ceff = C/Ag
4.66
kJ/(m²K)
Max. intende operation temperature - see note 3
Tmax,op
200
°C
Max. operation pressure - see note 3
pmax,op
1000 kPa
90°
0.00
90°
0.00
Pressure drop table - for a collector family, the values shall be for the module with highest ΔP per m² aperture area
Flow rate
kg/(s m²)
Pressure drop, ΔP
Pa
Optional weather data
Location
Testing Laboratory
Website
Test report id. number
Link
TestLab Solar Thermal Systems, Fraunhofer ISE
www.collectortest.com
Date of test report
ktb-2008-54-k2
During the test GDIF/GTOT was always between
<0,3
and
2010/02/17
<0,3
Comments of testing laboratory:
Pressure drop was not determined.
Water
Note 1 Flow rate
0.020 kg/(s m²) Fluid
Note 2 Irradiance, G = 1000 W/m²; Ambient temperature , Ta=30 °C
Note 3 Given by manufacturer
Datasheet version: 4.05, 2013-11-07
Kiwa
Italia S.p.A.
Via
Treviso 32/34
31020
Vendemiano
(TV) - Italy
Kiwa Nederland
BV- ●
Wilmersdorf
50 ●-7327
ACSan
Apeldoorn
● The Netherlands
Tel:
+39
411755
+39
0438
- E-Mail:
[email protected]
- www.kiwa.it
Tel:
+31
55 0438
5393 393
● Fax:- Fax:
+31 55
5393
39022428
● E-Mail:
[email protected]
● www.kiwa-eup.com
Page 2/2
Annual collector output based on EN 12975 Test Results,
annex to Solar KEYMARK Certificate
Licence Number
Issued
CERTNO-80537/1
KIP-083601/01
9/12/2013
25-06-2014
Annual collector output kWh/module
Location and collector temperature (Tm)
Athens
Davos
Stockholm
Würzburg
Collector name
25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C
SavioSun RP60
2,663 1,945 1,331 2,053 1,469
Collector mounting: Fixed or tracking
985 1,502 1,017
654 1,628 1,094
693
Fixed; slope = latitude - 15° (rounded to nearest 5°)
Overview of locations
Latitude °
Gtot
kWh/m²
Ta
°C
Collector orientation or tracking mode
Athens
38
1,765
18.5
South, 25°
Davos
47
1,714
3.2
South, 30°
Stockholm
59
1,166
7.5
South, 45°
Würzburg
50
1,244
9.0
South, 35°
45
1900
4
Location
South, -15°
South/Süden/Sud, 30°
Gtot Annual total irradiation on collector plane
kWh/m²
Ta
Mean annual ambient air temperature
°C
Tm
Constant collector operating temperature (mean of in- and outlet temperatures)
°C
The calculation of the annual collector performance is performed with the official Solar Keymark spreadsheet
tool ScenoCalc. The collector output is calculated hour by hour according to the efficiency parameters from the
Keymark test using constant collector operating temperature (Tm). A detailed description of the calculations is
available at http://www.sp.se/en/index/services/solar/ScenoCalc/Sidor/default.aspx.
Kiwa Italia S.p.A. - Via Treviso 32/34 - 31020 San Vendemiano (TV) - Italy
BV ●- Fax:
Wilmersdorf
50 22428
● 7327 -AC
Apeldoorn
● The Netherlands
Tel:Kiwa
+39 Nederland
0438 411755
+39 0438
E-Mail:
[email protected]
- www.kiwa.it
Tel: +31 55 5393 393 ● Fax: +31 55 5393 390 ● E-Mail: [email protected] ● www.kiwa-eup.com
Datasheet version:
4.05, 2013-11-07
ScenoCalc version:
Ver. 4.05 (Nov, 2013)