Version: V2.0.8 Release Date: 2014-04-15 Copyright 2014, Builder: 2.3.0.0, Time: 08:36:01 LMT Vendor ID Vendor Name Vendor Text Vendor URL Device ID 310 d / 01 36 h ifm electronic gmbh www.ifm.com http://http://www.ifm.com/ifmgb/web/io-link-download.htm 370 d / 00 01 72 h Communication IO-Link Revision Bitrate Minimum Cycle Time SIO Mode Supported V1.1 COM2 2.300 ms Yes Features Block parametrization Data storage Yes Yes Device Variant LMT102 Electronic level sensor, 0...100 %, Length 38 mm LMT104 Electronic level sensor, 0...100 %, Length 153 mm LMT105 Electronic level sensor, 0...100 %, Length 253 mm LMT202 Electronic level sensor, 0...100 %, Length 28 mm LMT302 Electronic level sensor, 0...100 %, Length 38 mm LMC502 Electronic level sensor, 0...100 %, Length 31.6 mm, Process connection 1/2'' NPT Page 1 Process Data (Process Data Input) Total BitLength = 16 Name Description Datatype Bitoffset Bitlength Value Range Gradient Offset Unit Level Current level UIntegerT 2 14 0 to 100 1 Switchstate [OUT2]. State depends on [OU2] BooleanT 1 0 % (false) inactive (true) active Switchstate [OUT1]. State depends on [OU1] BooleanT 0 (false) inactive (true) active Page 2 Variables Name Standard Command Description Index Subindex DataType bitOffset 2 Sub 0 UIntegerT Length Access Default Rights 8 Bit wo Value Range Gradient Offset Unit (130) Restore Factory Setting (240) IO-Link 1.1 system test command 240, Event 8DFE will appear (241) IO-Link 1.1 system test command 241, Event 8DFE will disappear (242) IO-Link 1.1 system test command 242, Event 8DFF will appear (243) IO-Link 1.1 system test command 243, Event 8DFF will disappear (255) Command without effect, for internal use only Device Access Lock 12 Data Storage Lock Sub 0 RecordT 16 Bit bitOffs 1 BooleanT 1 Bit rw (0) Vendor Name 16 Sub 0 ro ifm electronic gmbh Vendor Text 17 Sub 0 ro www.ifm.com Product Name 18 Sub 0 ro Product ID 19 Sub 0 ro Product Text 20 Sub 0 ro Electronic level Page 3 Variables Name Description Index Subindex DataType bitOffset Length Access Default Rights Value Range Gradient Offset Unit sensor Serial Number 21 Sub 0 ro Hardware Version 22 Sub 0 ro Firmware Version 23 Sub 0 ro Application Specific Tag 24 Sub 0 Switch point 1, [SP1] shall be 67 greater than [rP1]. Please consider to the current [rP1] value. If the [SP1] will be set below [rP1] it will be refused. Sub 0 Sub 0 SP1 16 Byte rw IntegerT 16 Bit rw 62 4 to 98 1 0 % IntegerT 16 Bit rw 54 2 to 96 1 0 % The smaller the percentage of water within the medium, the smaller SP/rP shall be set. rP1 Reset point 1, [rP1] shall be 68 smaller than [SP1]. Please consider to the actual [SP1] value. If the [rP1] will be set above [SP1] it will be refused. Page 4 Variables Name Description Index OU1 Output configuration [OUT 1] 69 Subindex DataType bitOffset Sub 0 UIntegerT Length Access Default Rights 8 Bit rw Value Range Gradient Offset Unit (3) Hno / Hysteresis fct normally open (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (8) tch / Teach input SP2 Switch point 2, [SP2] shall be 70 greater than [rP2]. Please consider to the current [rP2] value. If the [SP2] will be set below [rP2] it will be refused. Sub 0 IntegerT 16 Bit rw 62 4 to 98 1 0 % Sub 0 IntegerT 16 Bit rw 54 2 to 96 1 0 % The smaller the percentage of water within the medium, the smaller SP/rP shall be set. rP2 Reset point 2, [rP2] shall be 71 smaller than [SP2]. Please consider to the actual [SP2] value. If the [rP2] will be set above [SP2] it will be refused. Page 5 Variables Name Description Index OU2 Output configuration [OUT 2] 72 Subindex DataType bitOffset Sub 0 UIntegerT Length Access Default Rights 8 Bit rw Value Range Gradient Offset Unit (4) Hnc / Hysteresis fct normally closed (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed FOU1 [OUT 1] behaviour in case of 77 fault Sub 0 UIntegerT 8 Bit rw (4) OFF (4) OFF (2) On dS1 Switch-On delay [OUT 1] 78 Sub 0 UIntegerT 16 Bit rw 0 0 to 100 0.1 0 s dr1 Switch-OFF delay [OUT 1] 79 Sub 0 UIntegerT 16 Bit rw 0 0 to 100 0.1 0 s FOU2 [OUT 2] behaviour in case of 80 fault Sub 0 UIntegerT 8 Bit rw (4) OFF (4) OFF (2) On dS2 Switch-On delay [OUT 2] 81 Sub 0 UIntegerT 16 Bit rw 0 0 to 100 0.1 0 s dr2 Switch-OFF delay [OUT 2] 82 Sub 0 UIntegerT 16 Bit rw 0 0 to 100 0.1 0 s P-n Output polarity for the switching outputs 85 Sub 0 UIntegerT 8 Bit rw (0) PnP (0) PnP (1) nPn Page 6 Variables Name Description Index Subindex DataType bitOffset Length Access Default Rights Value Range Gradient Offset Unit dFo Delay time of outputs after fault 86 Sub 0 UIntegerT 16 Bit rw 0 to 50 0.1 Commands Performs action on the sensor 241 Sub 0 UIntegerT 8 Bit wo 0 0 s (253) [rES] Reset to factory settings (1) [tSP1] Teach Switchpoint 1 is only available if [OU1] = Hno, Hnc (2) [tSP2] Teach Switchpoint 2 is only available if [OU2] = Hno, Hnc Events Code Name Type Description 20480 d / 50 00 h Device hardware fault Error Device Exchange 25376 d / 63 20 h Parameter error Error Check data sheet and values 30480 d / 77 10 h Short circuit Error Check installation 36032 d / 8C C0 h Signal fault Error Please check your application 36350 d / 8D FE h Test Event 1 Warning Event appears by setting index 2 to value 240, Event disappears by setting index 2 to value 241 36351 d / 8D FF h Test Event 2 Warning Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243 Page 7 Error Types ErrorCode Name Description 32768 d / 80 00 h Device application error - no details Service has been refused by the device application and no detailed information of the incident is available 32785 d / 80 11 h Index not available Access occurs to a not existing index 32786 d / 80 12 h Subindex not available Access occurs to a not existing subindex 32800 d / 80 20 h Service temporarily not available Parameter is not accessible due to the current state of the device application 32803 d / 80 23 h Access denied Write access on a read-only parameter 32816 d / 80 30 h Parameter value out of range Written parameter value is outside its permitted value range 32819 d / 80 33 h Parameter length overrun Written parameter length is above its predefined length 32820 d / 80 34 h Parameter length underrun Written parameter length is below its predefined length 32821 d / 80 35 h Function not available Written command is not supported by the device application 32822 d / 80 36 h Function temporarily unavailable Written command is not available due to the current state of the device application 32832 d / 80 40 h Invalid parameter set Written single parameter collides with other actual parameter settings 32833 d / 80 41 h Inconsistent parameter set Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed 32898 d / 80 82 h Application not ready Read or write service is refused due to a temporarily unavailable application 33025 d / 81 01 h Parameter hidden 33026 d / 81 02 h Parameter currently not available Page 8
© Copyright 2024 ExpyDoc