CERTIFICATE OF APPROVAL No CF 5239 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of ASTROFLAME (FIRESEALS) LIMITED Intumescent House, Unit 8 The IO Centre, Stephenson Road, Segensworth, Fareham, PO15 5RU Tel: 01329 844500 Fax: 0800 0197611 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: ______________________________________________________________________________ CERTIFIED PRODUCT TECHNICAL SCHEDULE ASTRO HPE SEALANT TS03 Penetration Sealing Systems & TS40 Linear Joint Systems Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Chairman - Management Council Issued: 15th April 2014 Valid to: 22nd November 2017 Page 1 of 5 This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429 CERTIFICATE No CF 5239 ASTROFLAME (FIRESEALS) LIMITED ASTRO HPE SEALANT 1. This approval relates to the use of ASTRO HPE intumescent sealant pipe closure system for fire protection where there are services penetrating walls. The detailed scope is given in the Approval Matrix included in this Certificate. This shows the acceptable configurations to provide fire resistance periods in accordance with BS EN 1366-3: 2009 of up to 120 minutes for differing services and elements of construction. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section 2 of the Technical Standards (Scotland), Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account.’ 3. The product is approved on the basis of: i) ii) iii) iv) v) Initial type testing Audit testing at the frequency specified in TS03 A design appraisal against TS03 Inspection and surveillance of factory production control Production surveillance under ISO 9001:2008 4. The masonry or concrete walls and drywalls shall be at least 100 mm thick and have at least the same fire rating as that required for the penetration seal. 5. The services which may be fitted through the seals are PVC, HDPE, ABS, insulated copper pipes and cables as detailed within the Approval Matrix included in this Certificate. 6. The approval relates to on-going production. Product and/or its immediate packaging is identified with the manufacturers’ name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. Further Information Further information regarding the details contained in this data sheet may be obtained from Astro Flame Ltd (Tel: 01329 844500). Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777, website: www.warringtonfire.net) Page 2 of 5 Signed th Issued: 15 April 2014 nd Valid to: 22 November 2017 This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429 CERTIFICATE No CF 5239 ASTROFLAME (FIRESEALS) LIMITED ASTRO HPE INTUMESCENT SEALANT Approval Matrix – ASTRO HPE SEALANT EN 1366-3 Pipe Size and Type PVC – 125mm Ø by 4.8-7.2 mm wall thickness PVC – 40mm Ø by 1.93 mm wall thickness HDPE – 90mm Ø by 9.2 mm wall thickness ABS – 90mm Ø by 6mm wall thickness Copper – 60mm Ø by 0.8-14.2mm wall thickness, with 32mm Armaflex insulation Copper –13 Ø by 0.87mm wall thickness, with 13mm Armaflex insulation Walls Application Technique: Service Coat-Back : Service Support Requirements: Resistance to Smoke: Acoustic Rating: Page 3 of 5 Signed ASTRO HPE Dimensions 16 mm annulus x 25mm deep Backing Material Integrity Insulation 120 minutes 120 minutes 120 minutes 90 minutes 120 minutes 120 minutes Stone wool 30mm deep nominal 3 80kg/m 10 mm annulus x 25mm deep 12.5 mm annulus x 25mm deep 12.5 mm annulus x 25mm deep 20 mm annulus x 25mm deep Minimum Wall Thickness 100 mm N/A 12 mm annulus x 25mm deep The walls shall be a minimum of 100 mm thick. Drywalls shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50 mm studs. Masonry/concrete walls shall have 3 a minimum density for concrete or brick of 780kg/m and for aerated 3 concrete blocks of 600kg/m . All walls shall have at least the same fire rating as that required for the pipe closure system. The hole for the pipe shall be drilled to suit the required annular space. The pipe shall then be positioned centrally within the hole and then the remaining annular space shall be in-filled to full depth (of the drywall skin) min 25mm, with the ASTRO HPE intumescent sealant material. Not U Value: Not required known Services should be rigidly supported via steel angles, hangars or channels, not further than 150 mm and 450 mm from the surface of the sealing system on both faces. Not Not evaluated by this Weather Capability: evaluated by approval this approval Not Not evaluated by this Movement Capability: evaluated by approval this approval th Issued: 15 April 2014 nd Valid to: 22 November 2017 This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429 CERTIFICATE No CF 5239 ASTROFLAME (FIRESEALS) LIMITED ASTRO HPE INTUMESCENT SEALANT Approval Matrix – ASTRO HPE SEALANT EN 1366-3 Pipe Size and Type ASTRO HPE Dimensions HDPE – 63mm Ø by 7.2 mm wall thickness with Cables up to Ø 21mm 300mm wide x 100mm high x 25mm deep Cables up to Ø 21mm Walls Application Technique: Service Coat-Back : Service Support Requirements: Resistance to Smoke: Acoustic Rating: Page 4 of 5 Signed Backing Material Minimum Wall Thickness Integrity Insulation N/A 100 mm 120 minutes 120 minutes 300mm wide x 100mm high x 25mm deep The walls shall be a minimum of 100 mm thick. Drywalls shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50 mm studs. Masonry/concrete walls shall 3 have a minimum density for concrete or brick of 780kg/m and for 3 aerated concrete blocks of 600kg/m . All walls shall have at least the same fire rating as that required for the pipe closure system. The hole for the pipe shall be drilled to suit the required annular space. The pipe shall then be positioned centrally within the hole and then the remaining annular space shall be in-filled to full depth (of the drywall skin) min 25mm, with the ASTRO HPE intumescent sealant material. Not U Value: Not required known Services should be rigidly supported via steel angles, hangars or channels, not further than 150 mm and 450 mm from the surface of the sealing system on both faces. Not Not evaluated by this evaluated Weather Capability: approval by this approval Not Not evaluated by this evaluated Movement Capability: approval by this approval th Issued: 15 April 2014 nd Valid to: 22 November 2017 This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429 CERTIFICATE No CF 5239 ASTROFLAME (FIRESEALS) LIMITED ASTRO HPE INTUMESCENT SEALANT Approval Matrix – ASTRO HPE EN 1366-4 Wall Installations ASTRO HPE Product Name Joint Width mm Depth 20 25 Backing Material Gap Face Material Integrity (mins) Insulation (mins) PE Backing AAC/DW 120 120 mm Application Technique Compress backing material into gap/joint to form a pocket of the correct depth for the sealant to finish flush with the surface of the wall, then infill with ASTRO HPE to a depth off 25mm. The seal is required to be formed on both faces/sides of the wall. Walls The walls shall be a minimum of 100 mm thick. Drywalls shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50 mm studs. 3 Masonry/concrete walls shall have a minimum density for concrete or brick of 780kg/m 3 and for aerated concrete blocks of 600kg/m . All walls shall have at least the same fire rating as that required for the pipe closure system. Resistance to Smoke: Not evaluated by this approval Weather Capability: Not evaluated by this approval Acoustic Rating: Not evaluated by this approval Movement Capability: Not evaluated by this approval AAC PE DW - Autoclaved aerated concrete Polyethylene Drywall Page 5 of 5 Signed th Issued: 15 April 2014 nd Valid to: 22 November 2017 This certificate is the property of Warrington Certification Limited, part of Exova (UK) Ltd. Registered office: Lochend Industrial Estate, Newbridge, Midlothian, EH28 8PL, UK. Registered in Scotland, No. SC 70429
© Copyright 2024 ExpyDoc