accoLED 5 Elements Specification

accoLED5
recessed
accoLED 5
elements
direct
recessed 3"
3.375”
2.25”
Delivered Lumens Pending Test Results.
Available Light Platforms:
LED
2
Available Mounting:
controls
friendly
recessed
w w w.al i ghts .c om
a·light
project
type
quantity
interior
Mounting:
Flush Gypsum/Hard Lid Ceiling or Wall: “Flangeless” appearance for gyp or other
hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum
flange must be attached to blocking (by others), mudded over and painted by
ceiling contractor for flangeless appearance.
1” Regressed Gypsum/Hard Lid Ceiling or Wall: Same as above except regressed
flange raises lens 1” into ceiling resulting in a 4.5” height. Interior 1" regressed
portion is exposed raw aluminum and visible on both sides unless finish is chosen.
Contractor should apply ceiling paint if finish is not chosen.
Trim Flange: 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/
wall that requires a minimal flange covering the ceiling cut-out edge. Choose finish
color for trim flange.
T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw
aluminum flange sits on T-Bar, is not visible and is not painted.
4” Armstrong Techzone™ / USG Logix™ or other 4” Utility Systems: Suitable for
use in 4” on-center standard or slot T-Bar systems. Raw aluminum flange sits on
T-Bar, is not visible and is not painted. N4 is regressed, T4 is flush.
Lengths:
All length dimensions are nominal, used for general length identification purposes.
Actual lengths may vary by several inches. Lengths to 12' are individual fixtures
and do not connect. Lengths beginning with "R" designate standard, nominal rows
comprised of 4' and/or 8' sections.
Specify all modifications with the “integrations” specification sheet: nominal lengths
other than the standards available here, rows longer than 24', exact lengths,
patterns, shadowmolding or other mount types.
LED:
5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen
table for specifications per foot. All specifications are subject to change.
Construction:
60% recycled aluminum extruded housing. Steel endcap for T-Bar flanges, milled
aluminum endcap for gyp or trim flange.
Finish:
Electrostatically applied powder coat finish. Finish applies to MR16 module plates
and XP trim flange.
Listing:
UL/CUL. Damp Location.
Wet Label:
Specify in Options. Lens required.
Family Luminaires:
ACL1 suspended, ACL2 suspended/ceiling/wall, ACL3 suspended/ceiling/wall,
ACL4 wall
Companion Luminaires:
D6 recessed, D3 wall/suspended/ceiling, D7 recessed wall wash
Legend:
1.
Emergency ballast not applicable on lengths 3ft or less.
2.
Contact Factory for available Multi-circuit options.
3.
Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter.
4.
Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight
harvesting. Requires 0-10V dimming ballast.
5.
The N4 mounting requires the housing to sit on top of the slot T-Bar creating a slight
regress and will not sit flush to ceiling tile.
elements
exterior
Series:
ACL 5
Dimension:
nominal 2’ 1 2
nominal 3’ 1 3
nominal 4’
4
nominal 8’
8
nominal 12’
12
nominal 16’ row
R16
nominal 20' row
R20
nominal 24’ row
R24
Mounting:
flush gyp/hard lid - no finish
G
1" regressed gyp - optional finish
RG
trim flange - choose finish
XP
t-bar 9/16” - no finish
T
t-bar 15/16” - no finish
X
t-bar 9/16” slot - no finish
N
4” on center standard t-bar - no finish
T4
4” on center slot t-bar - no finish 5 N4
LED Output:
LED standard output
LS
LED high output
LH
LED Temp:
3000k
30
3500k
35
4000k
40
Optics:
HTLO™ lens
H
HTLO™ vertical
HV
HTLO™ vertical + horizontal
HVH
WISP™ lens (recommended)
S
Voltage:
universal 120V - 277V
U
120V
1
277V
2
347V
3
Finish:
a∙lightanium™
T
satin white
W
satin black
B
other - specify RAL#
O
no finish (t-bar or gyp)
Options:
dimming - specify manufacturer, model/series and voltage
D
emergency - specify model/series or lumens with remote transformer 1 E
w w w.al i ghts .c om
Version | Nov 2014
external fusing
multi-circuit
new york city code
chicago plenum code
occupancy sensor
photocell/daylight sensor
natatorium application
wet label
2
3
4
recessed
accoLED 5
F
M
N
C
O
P
K
Q
3