accoLED5 recessed accoLED 5 elements direct recessed 3" 3.375” 2.25” Delivered Lumens Pending Test Results. Available Light Platforms: LED 2 Available Mounting: controls friendly recessed w w w.al i ghts .c om a·light project type quantity interior Mounting: Flush Gypsum/Hard Lid Ceiling or Wall: “Flangeless” appearance for gyp or other hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum flange must be attached to blocking (by others), mudded over and painted by ceiling contractor for flangeless appearance. 1” Regressed Gypsum/Hard Lid Ceiling or Wall: Same as above except regressed flange raises lens 1” into ceiling resulting in a 4.5” height. Interior 1" regressed portion is exposed raw aluminum and visible on both sides unless finish is chosen. Contractor should apply ceiling paint if finish is not chosen. Trim Flange: 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/ wall that requires a minimal flange covering the ceiling cut-out edge. Choose finish color for trim flange. T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw aluminum flange sits on T-Bar, is not visible and is not painted. 4” Armstrong Techzone™ / USG Logix™ or other 4” Utility Systems: Suitable for use in 4” on-center standard or slot T-Bar systems. Raw aluminum flange sits on T-Bar, is not visible and is not painted. N4 is regressed, T4 is flush. Lengths: All length dimensions are nominal, used for general length identification purposes. Actual lengths may vary by several inches. Lengths to 12' are individual fixtures and do not connect. Lengths beginning with "R" designate standard, nominal rows comprised of 4' and/or 8' sections. Specify all modifications with the “integrations” specification sheet: nominal lengths other than the standards available here, rows longer than 24', exact lengths, patterns, shadowmolding or other mount types. LED: 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. Construction: 60% recycled aluminum extruded housing. Steel endcap for T-Bar flanges, milled aluminum endcap for gyp or trim flange. Finish: Electrostatically applied powder coat finish. Finish applies to MR16 module plates and XP trim flange. Listing: UL/CUL. Damp Location. Wet Label: Specify in Options. Lens required. Family Luminaires: ACL1 suspended, ACL2 suspended/ceiling/wall, ACL3 suspended/ceiling/wall, ACL4 wall Companion Luminaires: D6 recessed, D3 wall/suspended/ceiling, D7 recessed wall wash Legend: 1. Emergency ballast not applicable on lengths 3ft or less. 2. Contact Factory for available Multi-circuit options. 3. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. 4. Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight harvesting. Requires 0-10V dimming ballast. 5. The N4 mounting requires the housing to sit on top of the slot T-Bar creating a slight regress and will not sit flush to ceiling tile. elements exterior Series: ACL 5 Dimension: nominal 2’ 1 2 nominal 3’ 1 3 nominal 4’ 4 nominal 8’ 8 nominal 12’ 12 nominal 16’ row R16 nominal 20' row R20 nominal 24’ row R24 Mounting: flush gyp/hard lid - no finish G 1" regressed gyp - optional finish RG trim flange - choose finish XP t-bar 9/16” - no finish T t-bar 15/16” - no finish X t-bar 9/16” slot - no finish N 4” on center standard t-bar - no finish T4 4” on center slot t-bar - no finish 5 N4 LED Output: LED standard output LS LED high output LH LED Temp: 3000k 30 3500k 35 4000k 40 Optics: HTLO™ lens H HTLO™ vertical HV HTLO™ vertical + horizontal HVH WISP™ lens (recommended) S Voltage: universal 120V - 277V U 120V 1 277V 2 347V 3 Finish: a∙lightanium™ T satin white W satin black B other - specify RAL# O no finish (t-bar or gyp) Options: dimming - specify manufacturer, model/series and voltage D emergency - specify model/series or lumens with remote transformer 1 E w w w.al i ghts .c om Version | Nov 2014 external fusing multi-circuit new york city code chicago plenum code occupancy sensor photocell/daylight sensor natatorium application wet label 2 3 4 recessed accoLED 5 F M N C O P K Q 3
© Copyright 2024 ExpyDoc