17 18 Specification Sheet DESIGNATION- 250S125-33 ICC ER-4943P Galvanization G60 Web 2.5 In Flange 1.25 In Weight 0.0346 in Design Thickness 0.600 Lb/ft. Yield Strength 33 KSI Mils 33 Mils Gauge 20 0 Section Properties Gross Section Properties Cross Sectional Area A 0.176 in^2 Moment of Inertia about the X-X axis Ixx 0.178 in^4 Radius of Inertia about the X-X axis Rx 1.006 in Moment of Inertia about the Y-Y axis Iyy 0.033 in^4 Radius of Gyration about the Y-Y axis Ry 0.431 in Distance from Shear Center to Neutral Axis Xo 0.04 in St. Venant Torsion Constant J x 1000 399 in^4 Warping Constant Cw 0.07 in^6 Radii of Gyration Ro 0.532 in Torsional Flexural Constant ß 1.408 Moment of Inertia about the X-X Axis Ixx 0.175 in^4 Effective Section Modulus about the X-X Axis Sx 0.125 in^3 Allowable Bending Moment Ma 2.480 in-k Torsional Section Properties Effective Section Properties Interior Non-Structural Composite Spacing o.c. 5 psf (in) 12 16 24 10 psf 7.5 psf L/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360 19' 8" 17' 11" 15' 8" 15' 8" 14' 3" 12' 5" 13' 8" 12' 5" 10' 10" 17' 3" 15' 8" 13' 8" 13' 8" 12' 5" 10' 10" 11' 11" 10' 10" 9' 5" 15' 8" 14' 3" 12' 4" f 12' 5" 11' 3" 9' 10" 10' 10" 9' 10" 8' 4" L/360 L/120 TABLE NOTES: 1. f: Flexural stress controls allowable height 2. 5/8" Gypsum Board both sides full height 3. Tested per 2008 ICC ES Acceptance Criteria AC-86 4. Galvanizing to be G-40 minimum for 5 PSF or less & G-60 minimum for Greater than 5 PSF Lateral Loads Interior Non-Structural Non-Composite Spacing o.c. 5 psf (in) L/120 L/240 7.5 psf L/360 L/120 L/240 10 psf L/240 L/360 12 16 24 TABLE NOTES: 1. End lateral bearing - 1 inch minimum 2. Heights based on steel properties only 3. Limiting heights based on 1/2" minimum gypsum wall board attached to each face to within 4 feet of the end of the stud OR 1/2" gypsum wall board attached to one face and the unsheated flange laterally braced at 4 foot o.c. for the length of the stud Steel Construction Systems Corporation ("Steel Construction Systems") Disclaimer: All data, specifications and detail contained in this publication are intended as a general guide for using Steel Construction Systems’s products. These products should not be used in design or construction without an independent evaluation by a qualified engineer or architect. Steel Construction Systems assumes no liability for failure resulting from the use or misapplication. Steel Construction Systems reserves the right to make modifications and/or change materials of any of their products without prior notice or obligation.
© Copyright 2024 ExpyDoc