ARIA Lightpaths Raceway

ARIA Lightpaths Raceway - Selection Guide
Components
Page 1
DS-C-1
Revision date 06/23/2014
Overview
Lighpaths™ Fiber Protection System, ducting, or
raceway is the ideal system for routing and protecting
cables routed through exchanges, central offices, CATV
headends, data centers, collocation sights, hubs, shelters,
nodes, and customer premises.
Lighpaths™ maintains a 2” bend radius throughout the
system. Lighpaths™ is the only Halogen-free system on
the market, and the only system that exceeds Telcordia
GR-63 NEBS requirements as tested by an independent
third party test lab.
Mounting Hardware
The parts connecting the Lighpaths™ system do not
require mounting hardware. No other system on the
market can make this claim. Parts are assembled in
seconds with the new patented slide-on-joiner. Vertical
drops can be added in less than 5 minutes by snapping
them in place with no mounting hardware required. Drops
exit the side of the raceway in order to not interfere with
overhead ladder racking. Lighpaths™ is available in all
popular sizes to accomodate virtually any application.
Available Services
Mounting kits are available to affix the ducting to the ladder racking, threaded rod, cabinets, racks, and wall. Technical
application assistance and field support is provided to end-users, installers, and contractors. Installation services and
engineering services are also available.
Typical Installations
Colocation Sites or Central
Offices
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
CATV Headends or Data
Centers
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
Customer Premises, Hubs,
Shelters
Fiber Frame Management
ARIA Lightpaths Raceway - Selection Guide
Page 2
DS-C-1
Revision date 06/23/2014
Components
Capacity
Raceway Size (HxW)
2”x2”
(50mm x 50mm)
145
Max Patchcord
Capacity (3.0 mm OD)
4”x4”
(100mm x 100mm)
4”x8”
(100mm x 220mm)
4”x12”
(100mm x 300mm)
720
1100
1500
Solid Straight Sections
Solid straight sections are used for horizontal routes.
Standard length is 2 meters (6.5 feet). Lids are hinged,
providing easy accessibility.
Part Numbers
Size (HxW)
Body Part Number
Cover Part Number
2”x2” (50mm x 50mm)
TC1279-81
TC1279-80
4”x4” (100mm x 100mm)
TC1279-23NS
TC1279-24
4”x8” (100mm x 220mm)
TC1279-21NS
TC1279-22
4”x12” (100mm x 300mm)
TC1279-275NS
TC1279-276
Slotted Straight Sections
Slotted straight sections are used for vertical routes
bringing cables to equipment in racks or cabinets.
Slot trumpets provide bend radius protection (order
separate).
Slot Trumpets provide the
proper bend radius for
cables exiting
Part Numbers
Size (HxW)
Part Number
2”x2” (50mm x 50mm)
(includes mounting hardware & short lid)
TC1279-81SLAKit
Slot trumpets
(can be used with any slotted straight section)(10 per bag)
TC1279-212
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
ARIA Lightpaths Raceway - Selection Guide
Page 3
DS-C-1
Revision date 06/23/2014
Components
Horizontal Tees & Covers
Horizontal Tees are used to change directions
perpendicular to the main route.
Tees can also tee-off in a different size (i.e. 4”x 8” to 4” x
4”).
Use tees at corners where horizontal routes may
continue.
Part Numbers
Size (HxW)
Body Part Number
Cover Part Number
2”x2” (50mm x 50mm)
TC1279-75A
Supplied with body
4”x4” (100mm x 100mm)
TC1279-03NS
TC1279-04
4”x8” (100mm x 220mm)
TC1279-01NS
TC1279-02
4”x12” (100mm x 300mm)
TC1279-279NS
TC1279-280
Horizontal Crosses & Covers
Horizontal Crosses are used to change directions
perpendicular to the main route.
Part Numbers
Size (HxW)
Body Part Number
Cover Part Number
2”x2” (50mm x 50mm)
TC1279-139A
Supplied with body
4”x4” (100mm x 100mm)
TC1279-71
TC1279-70
4”x8” (100mm x 220mm)
TC1279-61
TC1279-62
4”x12” (100mm x 300mm)
TC1279-300
TC1279-300L
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
ARIA Lightpaths Raceway - Selection Guide
Components
Page 4
DS-C-1
Revision date 06/23/2014
Horizontal Elbows & Covers
Horizontal Elbows are used to change directions
perpendicular to the main route.
Elbows are ideal for use at corners where horizontal
routes will not continue.
30, 45, and 90 elbows are available.
Part Numbers
Angle
Size (HxW)
Body Part Number
Cover Part Number
30 Degree
2”x2” (50mm x 50mm)
TC1279-77-30A
Supplied with Body
30 Degree
4”x4” (100mm x 100mm)
TC1279-31-30
TC1279-32-30
30 Degree
4”x8” (100mm x 220mm)
TC1279-29-30
TC1279-30-30
45 Degree
2”x2” (50mm x 50mm)
TC1279-77-45A
Supplied with Body
45 Degree
4”x4” (100mm x 100mm)
TC1279-31-45
TC1279-32-45
45 Degree
4”x8” (100mm x 220mm)
TC1279-29-45
TC1279-30-45
45 Degree
4”x12” (100mm x 300mm)
TC1279-304
TC1279-305
90 Degree
2”x2” (50mm x 50mm)
TC1279-77A
Supplied with Body
90 Degree
4”x4” (100mm x 100mm)
TC1279-31
TC1279-32
90 Degree
4”x8” (100mm x 220mm)
TC1279-29
TC1279-30
End Caps
End Caps are used to close the end of a horizontal or
vertical route.
Some end caps are used with tubing to drop cables into
frames or cabinets.
Part Numbers
Size (HxW)
Body Part Number
2”x2” (50mm x 50mm)
TC1279-127D
4”x4” (100mm x 100mm)
TC1279-57
4”x4” (100mm x 100mm), with 2 ea 5 feet length tubes
TC1279-57B2Kit
4”x8” (100mm x 220mm)
TC1279-56
4”x12” (100mm x 300mm)
TC1279-288
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
ARIA Lightpaths Raceway - Selection Guide
Components
Page 5
DS-C-1
Revision date 06/23/2014
Vertical Elbows & Covers
Vertical Elbows are used to change directions upward or
downward to avoid obstacles.
45 and 90 elbows are available in most sizes.
Retro elbows are supplied with a slit in the body to
permit entrance of existing cables without the need to
disconnect.
Vertical Elbow
Retro Elbow
Part Numbers
Type and Angle
Size (HxW)
Body Part Number
Cover Part Number
Elbow Up 45 Degree
2”x2” (50mm x 50mm)
TC1279-143-45A
Supplied with Body
Elbow Up 45 Degree
4”x4” (100mm x 100mm)
TC1279-113-45A
Supplied with Body
Elbow Up 45 Degree
4”x8” (100mm x 220mm)
TC1279-125-45A
Supplied with Body
Elbow Up 45 Degree
4”x12” (100mm x 300mm)
TC1279-283
TC1279-284
Elbow Up 90 Degree
2”x2” (50mm x 50mm)
TC1279-143A
Supplied with Body
Elbow Up 90 Degree
4”x4” (100mm x 100mm)
TC1279-113A
Supplied with Body
Elbow Up 90 Degree
4”x8” (100mm x 220mm)
TC1279-125A
Supplied with Body
Elbow Up 90 Degree
4”x12” (100mm x 300mm)
TC1279-298
TC1279-284A
Elbow Down 45 Degree
2”x2” (50mm x 50mm)
TC1279-87-45A
Supplied with Body
Elbow Down 45 Degree
4”x4” (100mm x 100mm)
TC1279-111-45A
Supplied with Body
Elbow Down 45 Degree
4”x8” (100mm x 220mm)
TC1279-123-45A
Supplied with Body
Elbow Down 45 Degree
4”x12” (100mm x 300mm)
TC1279-285
TC1279-285L
Elbow Down 90 Degree
2”x2” (50mm x 50mm)
TC1279-87A
Supplied with Body
Elbow Down 90 Degree
4”x4” (100mm x 100mm)
TC1279-111A
Supplied with Body
Elbow Down 90 Degree
4”x8” (100mm x 220mm)
TC1279-123A
Supplied with Body
Elbow Down 90 Degree
4”x12” (100mm x 300mm)
TC1279-296A
TC1279-286A
Retro Elbow Down 90 Degree 4”x4” (100mm x 100mm)
TC1279-111R
Supplied with Body
Retro Elbow Down 90 Degree 4”x8” (100mm x 220mm)
TC1279-123R
Supplied with Body
Retro Elbow Up 90 Degree
4”x4” (100mm x 100mm)
TC1279-113R
Supplied with Body
Retro Elbow Up 90 Degree
4”x8” (100mm x 220mm)
TC1279-125R
Supplied with Body
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
ARIA Lightpaths Raceway - Selection Guide
Components
Flared Trumpets
Flared Trumpets are used to ensure proper bend radius
for cables exiting vertically from the horizontal route.
Part Numbers
Size (HxW)
Body and Cover Part Number
2”x2” (50mm x 50mm)
TC1279-93A
4”x4” (100mm x 100mm)
TC1279-218A
4”x8” (100mm x 220mm)
TC1279-289R
Downspouts
Downspouts are typically used for adding drops to an
existing horizontal route.
By exiting the side of the system, interference with ladder
racking and other objects, typically mounted above the
horizontal raceway, is avoided.
To use the downspout to add drops, a quick punch-out
is made in the side wall, and a bend-radius ramp and
downspout are snapped into place in a few seconds.
Part Numbers
Size (HxW)
Kit Part Number
2”x2” (50mm x 50mm) Punch Tool
TC1279-50
4”x4” (100mm x 100mm) Punch Tool
TC1279-231A
2”x2” (50mm x 50mm) Downspout
TC1279-93KIT
4”x4” (100mm x 100mm) Downspout
TC1279-111KIT
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
Page 6
DS-C-1
Revision date 06/23/2014
ARIA Lightpaths Raceway - Selection Guide
Components
Page 7
DS-C-1
Revision date 06/23/2014
Pre-assembled Downspouts
Pre-assembled Downspouts are horizontal tees
with vertical downspouts. By exiting the side of the
system, interference with ladder racking and other
objects, typically mounted above the horizontal
raceway, is avoided.
Kits can be supplied with downspouts preassembled on one or both sides of short straight
section. To use the downspout to add drops, just
assemble to a slide-on joiner which takes seconds.
Part Numbers
Size (HxW)
Body and Cover Part Number
4”x4” (100mm x 100mm) with 4”x4” drop
TC1279-4DROP-4
4”x4” (100mm x 100mm) with 2”x2” drop
TC1279-2DROP-4
4”x8” (100mm x 220mm) with 4”x4” drop
TC1279-4DROP-8
4”x8” (100mm x 220mm) with 2”x2” drop
TC1279-2DROP-8
4”x12” (100mm x 300mm) with 4”x4” drop
TC1279-4DROP-12
Vertical Tees & Covers
Vertical Tees are used to drop cables vertically from
horizontal routes into frames or cabinets directly
underneath raceway.
Vertical Tees have cable dividers.
Retro Tees are supplied with a slit in the body to
permit entrance of existing cables without the need to
disconnect.
Part Numbers
Type
Size (HxW)
Drop Size (HxW)
Body Part Number Cover Part Number
Vertical Tee
2”x2” (50mm x 50mm)
2”x2”
TC1279-145A
Supplied with Body
Vertical Tee
4”x4” (100mm x 100mm)
4”x4”
TC1279-63
TC1279-64
Vertical Tee
4”x8” (100mm x 220mm)
4”x4”
TC1279-11
TC1279-12
Vertical Tee
4”x12” (100mm x 300mm)
4”x8”
TC1279-277
TC1279-278
Retro Tee
4”x4” (100mm x 100mm)
4”x4”
TC1279-63R
Supplied with Body
Retro Tee
4”x8” (100mm x 220mm)
4”x4”
TC1279-111R
Supplied with Body
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
ARIA Lightpaths Raceway - Selection Guide
Components
Joiners/Junctions
Joiners are used to connect two parts together, and slide
on to parts with no tooling or hardware required.
Joiners connect in seconds. 1/4 turn locks parts together.
Part Numbers
Size (HxW)
Part Number
2”x2” (50mm x 50mm)
TC1279-73
4”x4” (100mm x 100mm)
TC1279-248A
4”x8” (100mm x 220mm)
TC1279-250A
4”x12” (100mm x 300mm)
TC1279-287A
Lightpaths to ADC Adapter kits
Adapters and Reducers are used to connect parts of
different sizes or brands.
Part Numbers
Size (HxW)
Body and Cover Part Number
100mm x 100mm to 100mm x 220mm 4” x 4” - 4” x 8” left
TC1279-07A
100mm x 100mm to 100mm x 220mm 4” x 4” - 4” x 8” right
TC1279-05A
100mm x 220mm to 100mm x 300mm 4” x 8” - 4” x 12”
TC1279-281A
100mm x 100mm to ADC 4” straight 4” x 4” - ADC 4”
TC1279-109KIT
100mm x 100mm to ADC 4” horiz tee 4” x 4” - ADC 4”
TC1279-173KIT
100mm x 220mm to ADC 6” straight 4” x 8” - ADC 6”
TC1279-149KIT
100mm x 220mm to ADC 6” straight 4” x 8” - ADC 6”
TC1279-150KIT
100mm x 220mm to ADC 6” horiz tee 4” x 8” - ADC 6”
TC1279-175KIT
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
Page 8
DS-C-1
Revision date 06/23/2014
ARIA Lightpaths Raceway - Selection Guide
Page 9
DS-C-1
Revision date 06/23/2014
Components
Storage Spools
Storage Spools are used to store excess cable slack up in the ducting
system where it is safe from mishandling and potential damage.
In-line Spools can be placed within or at the end of a horizontal run.
Spools are ideal for under-floor slack cable storage in data centers.
Part Numbers
Size (HxW)
Part Number
2”x2” (50mm x 50mm)
TC1279-209KIT (in-line)
4”x4” (100mm x 100mm)
TC1279-208KIT (in-line)
4”x8” (100mm x 220mm)
TC1279-207KIT (in-line)
4”x8” (100mm x 220mm)
TC1279-314-K (under floor)
4”x12” (100mm x 300mm)
TC1279-315-K (under floor)
Mounting Hardware
Mounting Hardware is available for
virtually any kind of installation. Kits
are available for mounting to ladder
racking, threaded rod, wall mounting,
and under floor pedestal mounting.
Under Floor Mount Trapeze Mount Ladder Rack Mount Threaded Rod Mount
Part Numbers
Size (HxW)
Mounting Kit Style
Part Number
2”x2” (50mm)
Ladder Rack
TC1279-203KIT
2”x2” (50mm)
Cabinet Mount
TC1279-168KIT
2”x2” (50mm)
Wall Mount
TC1279-168KIT
4”x4” (100mm)
Ladder Rack
TC1279-202KIT
4”x4” (100mm)
Threaded Rod 1/2 inch existing
TC1279-105KITC-1
4”x4” (100mm)
Threaded Rod 5/8 inch existing
TC1279-105KITD-1
4”x4” (100mm)
Under Floor Pedestal Mount
TC1279-197KITA
4”x4” (100mm)
Wall Mount
TC1279-14 -104KIT
4”x8” (220mm)
Ladder Rack
TC1279-184KIT
4”x8” (220mm)
Threaded Rod 1/2 inch existing
TC1279-105KITC-2
4”x8” (220mm)
Threaded Rod 5/8 inch existing
TC1279-105KITD-2
4”x8” (220mm)
Under Floor Pedestal Mount
TC1279-197KITA
4”x8” (220mm)
Wall Mount
TC1279-133KIT
4”x12” (300mm)
Trapeze Kit Threaded Rod 1/2 inch existing
TC1279-297BKIT
4”x12” (300mm)
Trapeze Kit Threaded Rod 5/8 inch existing
TC1279-297DKIT
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]