Cable Fault Location Systems Cable Testing and Diagnostics Determine failures in cable systems quickly and precisely by means of efficient pre-location and pin-point location BAUR Cable Fault Location System BAUR Cable Locator Underground cable networks are expensive. Condition-based maintenance is getting more important for operators methods. Cable fault location requires rugged, reliable, flexible equipment which can apply all the required methods Syscompact 2000 CL 20 of power cable networks. Precise knowledge about the condition of cable circuits becomes a competitive advantage. of identifying a fault. The Syscompact 2000 is a multifunctional With the CL 20 it is easy to trace long or cable fault location system designed for short cables. It can be used with differ- modular 19“ rack technology. Syscompact is a combination of ent tracing methods. Besides tracing it can also evaluate BAUR VLF High Voltage Test and BAUR VLF High Voltage Test BAUR TDR BAUR Surge Voltage Generators TDR IRG 2000, coupling devices for SM/MIM, ICM fault prelo- the depth of the cable. The CL 20 is perfect for construction Diagnostics Device Systems PHG 70 / PHG 80 IRG 2000 SSG 1100, 1500, 2100, 3000 cation methods and a powerful surge voltage generator SSG. workers to ensure the position of cable lines before they start frida / frida TD BAUR‘s fully automatic programmable The Pulse Reflection Test Set IRG 2000 is Surge voltage generators enable ac- Syscompact 2000 is available as portable solution or with 25 the excavation works. 70 to 80 % of cable lines are in a a portable, easy to use, single-phase unit curate location of high resistance, low m or 50 m cable drums for vehicle mounted version. Porta- voltage range of up to 20 kV. All these high-voltage generator PHG. ▪▪ VLF truesinus®, VLF square wave and DC in one device for cable fault prelocation using the Time Domain Reflection resistance and intermittent faults on high, medium and ble solutions are preferably equipped with 1100 J 8/16/32 BAUR Digital Receiver cables can be tested with frida TD easily and quickly. Ad- ▪▪ Max. test voltage 38 kVrms/54 kVpeak (PGH 70) (TDR) and other methods (e. g. SIM/MIM) on low, medium low voltage cables. The robust and powerful Surge Voltage kV surge generator. Vehicle mounted solution up to 3000 J, UL30 / BM30 ditionally the aging condition can be examined without Max. test voltage 57 kVrms/80 kVpeak (PGH 80) and high voltage cables. With its compact design it can Generators SSG 1100 (1100 Joule), SSG 1500 (1536 Joule), SSG 8/16/32 kV and optional 4 kV range available. UL30 is a digital multifunctional menu damage to cable. measure cables up to 65 km even in life lines up to 400 V and 2100 (2048 Joule) and SSG 3000 (3000 Joule) in a 19“ rack automatically display the fault distance. modular design are suitable as stand-alone units, or compo- BAUR Cable Fault Location System different pick-up devices this one single receiver can be used nents of the fault location systems Syscompact or Transcable. Syscompact 3000 for acoustic fault location also in pipes, step voltage The Syscompact 3000 is a multifunctional method, cable route tracing and twist method. For easy BAUR VLF High Voltage Test and operated receiver. In combination with BAUR TDR ▪▪ VLF cable testing, tan-δ-diagnostics and cable sheath Diagnosics Systems PHG 70 / 80 TD testing in one device and PHG 70 / 80 TD PD ▪▪ Max. test voltage 24 kVrms/34 kVpeak ▪▪ High precise tan-δ-measurement with an accuracy of The BAUR high voltage test and diagnostics device viola TD The testing and diagnostics IRG 3000 BAUR Burn Down Transformer cable fault location system. Combination pin-pointing of cable faults the digital Universal Locator UL For complex cable fault location the ATG 2, ATG 6000 of the computerized TDR IRG 3000, coupling devices for SIM/ 30 is used with the ground microphone BM 30 and a surge Echometer IRG 3000 is the right choice. It The burn down transformer ATG enables MIM, ICM fault prelocation methods and a powerful surge voltage generator (SSG/STG). Advanced signal pick-up of the user to change a high resistance fault voltage generator SSG up to 3000 Joules, 32 kV, 3 voltage magnetic and acoustic signal and distance to the fault indi- BAUR VLF High Voltage Test and voltage testing, dissipation factor measurement tan δ, cation. Diagnostics Device partial discharge level measurement and partial discharge viola / viola TD localization. is easy to use, fully computerized and offers unique features (1 * 10 -4) based on VLF-truesinus®-technology (frida TD) evaluation of cable condition. The systerms combine VLF of intelligent and automatic cable fault location, for example into a low resistance fault. Thus allowing a TDR to be used for ranges 8/16/32 kV, extendable with 4 kV range. The Syscom- the SIM/MIM method (in combination with a surge genera- low resistance fault pre-location. The power can be matched pact 3000 system can be extended with a highvoltage VLF or tor). With a measuring range of more than 200 km also faults due to the different voltage ranges up to 10 kV DC (15 kV DC DC test instrument in order to allow cable fault location also BAUR Cable Test Van in long cables can be detected and automatically localized. for ATG 6000) even at full load. in transmission cables. Transcable 3000 agnostics device viola TD offers high power in a compact The BAUR Transcable can be designed to design. With the output voltage of 42.5 kVrms (60 kVpeak), clients demands. Depending on the use the device is suitable for testing and diagnostics on cable The IRG 3000 is mostly build into a Cable Fault Location System (Syscompact or Cable Test Van) and can be used as a BAUR Cable Identification System BAUR Audio Frequency Transmitter one- or three phase system. It can also be used to control VLF KSG 100 TG 600 of the system it can include cable fault location, testing and Testing and Diagnostic Systems. The cable identification system KSG The audio frequency transmitter TG 600 diagnosis. Also the voltage level and energy class is choos- 100 is used for selection of single and is especially designed for accurate loca- en depending on the network. Transcable Systems can be BAUR Low Voltage Cable multicore cables from a cable bundle. The amplitude, time tion of cable faults and joints according to the twist method designed as single phased or 3 phased version. All Systems Fault Location System STG 600 and phase control (ATP) discriminator provides the user with as well as tracing the cable and depth evaluation. An audio are completed with the BAUR Software 3.3 which manages The low voltage cable fault location the utmost security of cable identification and allows even frequency based signal with up to 600 VA and two choosa- the control of all important measurement methods over the system STG 600 includes a surge genera- indentification of life cables up to 400 V. ble frequencies (standard 2 kHz, 10 kHz) is fed into the cable complete cable life cycle. tor, a high voltage source for testing and precise location of BAUR Sheath Fault Location functional cable fault locating set especially designed for low System shirla voltage power distribution networks. The BAUR high voltage test and di- ▪▪ Partial discharge diagnostics (PD) according to IEC 60270 vidually programmable testing in one device ▪▪ Max. test voltage 42 kVrms/60 kVpeak tracy induces a signal to a pre-located location (expected PD location) in the cable. In combination with a PD meas- Diagnostics System PD Portable urement system, e.g., PHG TD PD, the signal induced can be located and compared with the result of the partial discharge location. and depth evaluation of cables with a tial discharges is an add-on for VLF test to 50 VA. Using additional accessories, The Surge generator SSG 500 with its voltage method. Besides the sheath testing and fault location pin-point fault location is enabled by acoustic method, step voltage range up to 16 kV is perfect for features, the measuring bridge is the ideal back-up tool for voltage method, twist method, and acoustic propagation low and medium voltage networks. It can be used in com- conventional cable fault location systems. Various bridge ap- time measurement. It consists of a Audio Frequency Trans- bination with an IRG as a pre-location test set applying the plications allow using shirla on more than just cable sheath. mitter, digital menu operated receiver (UL30), Headphones, ICM Method. Combined with a Pin-Point listening set, it is the Groundmicrophone, Search Coil and different connection portable solution for cable fault loation. accessories. BAUR Prüf- und Messtechnik GmbH · Raiffeisenstraße 8 · A-6832 Sulz · T +43 55 22 49 41-0 · F +43 55 22 49 41-3 · [email protected] · www.baur.at BAUR Prüf- und Messtechnik GmbH · Raiffeisenstraße 8 · A-6832 Sulz · T +43 55 22 49 41-0 · F +43 55 22 49 41-3 · [email protected] · www.baur.at BAUR’s partial discharge inductor BAUR Partial Discharge sheath test acc. to IEC60229 up to 10 kV, portable audio frequency generator up Inductor tracy (1 * 10 -4) based on VLF-truesinus®-technology (viola TD) The Locator Set is used for route tracing Methods as well as fault pinpointing according to the step BAUR Partial Discharge ▪▪ High precise tan-δ-measurement with an accuracy of All in one – combined instrument for fault pre-location according to Murray and Glaser Bridge Max. test voltage 57 kVrms/80 kVpeak (PGH 80 TD/PD) ▪▪ VLF cable testing, tan-δ-diagnostics and cable sheath The portable system for locating par- SSG 500 ▪▪ Max. test voltage 38 kVrms/54 kVpeak (PGH 70 TD/PD ▪▪ High precise tan-δ-measurement and automated, indi- BAUR Cable Fault Locator Set BAUR Surge Voltage Generator ▪▪ For medium voltage cables up to 50 kV with a rated voltage up to 35 kV. which is picked up with a Search Coil. sheath and cable insulation faults. The STG 600 is a multi- systems PHG TD/PD is multifunctional and allows a reliable generators frida and viola. ▪▪ Non-destructive partial discharge diagnostics (PD) according to IEC 60270 ▪▪ Measures PD levels (from 20 pc onwards) and locates PD ▪▪ Very easy to maintain, precise PD source confirmation ▪▪ IP 54 protection class ▪▪ Suitable for cables and electrical equipment sources (1 % accuracy) reliably over the entire cable line ▪▪ Easy operation via BAUR’s multilingual diagnostics software BAUR Prüf- und Messtechnik GmbH · Raiffeisenstraße 8 · A-6832 Sulz · T +43 55 22 49 41-0 · F +43 55 22 49 41-3 · [email protected] · www.baur.at Cable Testing and Diagnostics BAUR Mobile DC High Voltage Insulating Fluid Testing Insulating fluids are a key component of many electrical equipment. Highly refined mineral oils, silicone fluids, vegeta- Technical data BAUR PGK Testing Device PGK 25 BAUR’s mobile cable testing device PGK 25 is used for DC voltage testing in low and medium voltage cables. It is characterised by its light weight of 16.5 kg, its user friendliness and solid design for on-site testing. ▪▪ Two continuously adjustable voltage ranges: 0 - 5 kV and 0 - 25 kV DC (negative polarity) ▪▪ Battery operated or mains operated ▪▪ Built-in rechargeable battery of 12 V 6.5 Ah – approx. 30 - 60 minutes of operation. ▪▪ Maximum discharge energy of 5000 Ws (16 μF/25 kV/ interval of 20 min) BAUR Mobile DC High Voltage Testing Device PGK50 and PGK80 Maintenance of paper-oil-insulated cable systems and their potential life ble oil (natural esters) and synthetic esters guarantee the operation of transformers, medical and safety or even radar Output current Type Output Voltage For max. output voltage Shortcircuit current PGK 25 0 - 25 kV DC 1 mA DC 3 mA DC PGK 50 0 - 50 kV DC 2 mA DC 25 mA DC PGK 80 0 - 80 kV DC 0,8 mA DC 20 mA DC PGK 70 HB 0 - 70 kV DC 3 mA DC 12 mA DC 0 - 55 kV ACrms 7 mA AC 20 mA DC 0 - 70 kV DC 20 mA DC 84 mA DC 0 - 55 kV ACrms 50 mA AC 117 mA AC 0 - 110 kV DC 5 mA DC 17 mA DC 0 - 80 kV ACrms 14 mA AC 30 mA AC 0 - 110 kV DC 22 mA DC 104 mA DC 0 - 80 kV ACrms 66 mA AC 137 mA AC 0 - 150 kV DC 4 mA DC 20 mA DC 0 - 110 kV ACrms 9 mA AC 23 mA AC PGK 70/2,5 HB PGK 110 HB PGK 110/5 HB PGK 150 HB PGK 150/5 HB 0 - 150 kV DC 18 mA DC 77 mA DC 0 - 110 kV ACrms 50 mA AC 108 mA AC PGK 260 HB 0 - 260 kV DC 4 mA DC 20 mA DC 0 - 190 kV ACrms 9 mA AC 20 mA AC expectancy of 50 or even 100 years justifies the need for technology devices. Insulating materials lose their insulating and cooling properties due to impurities and ageing. The consequences include damage and failures of equipment and systems, even catastrophic failures resulting in transformer fires and the consequent costs and environmental damage. The testing of insulating fluids is therefore legally stipulated and regulated through national and international standards. Equally important are the economic reasons for regular testing to include extended lifetime of equipment and optimal use of insulating oils to achieve enormous potential savings. BAUR breakdown voltage testers DPA 60 C, DPA 75 C and DTA 100 C The BAUR breakdown testers are available as a portable version with 60 kV, 75 kV and as a laboratory optimized version with 100 kV. ▪▪ F ully automatic testing of the breakdown strength in compliance with international and national standards ▪▪ Suitable for mineral or silicone oils and esther liquids ▪▪ Reliable, reproducible measurement results using the latest measurement technology ▪▪ Designed for mobile use on site as well as for daily continuous operation in laboratories testing devices for this cable type. BAUR’s PGK 50 and PGK 80 cable testing devices are especially handy in respect to BAUR Online PD Spot Tester BAUR tan delta oil analyser DTL C their test voltage up to 50 kV and 80 kV. liona The tan Delta measurement is the most valuable oil testing method used worldwide during oil liona is a portable online PD spot tester production, oil refining and of course in laboratories for oil condition measurements. The BAUR for measuring and locating partial dis- oil analyser DTL C uses a unique principal to measure tan Delta values up to 1 x 10 -6. ▪▪ DC testing of PILC low and medium voltage cables up to charges in cables and switchgear during normal mains 50/80 kV ▪▪ Maximum discharge energy of 8000 Ws ▪▪ Fully automatic measurement of international standards operation. (interval of 15 min) ▪▪ Voltage measurement at the HV-output, display accuracy of +/- 2.5 % ▪▪ Automatic PD detection during normal mains operation ▪▪ Extraordinarily powerful for continuous use in laboratory ▪▪ Several calibrators that ensure accuracy and reproducibility for decades (without switching off the cable route) ▪▪ With DeCIFer® technology: PD identifi cation based on BAUR AC/DC High Voltage Testing Devices PGK HB 500 million measurement results ▪▪ Precise online PD mapping with iPD transponder BAUR ITS Lite oil testing software Management of measured data becomes easy with the BAUR testing software ITS Lite that can BAUR Product Overview be used to import and to archive test results from the DPA 75 C, the DTA 100 C and the DTL C. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage testing BAUR DAC Testing Systems up to devices of the PGK HB series. They generate continuously 400 kV adjustable DC test voltages with positive or negative polarity or AC test voltage power frequencies. Networks are sensitive. We help you to protect them. ▪▪ DAC withstand testing close to AC power frequency conditions (50/60 Hz) with application of IEEE, IEC, CENELEC and CIGRE recommendations ▪▪ DC Testing of medium and high voltage cables up to 260 kV ▪▪ Integrated sensitive PD measurement (IEC 60270) incl. PD ▪▪ Easy to use and maintenance free two part design ▪▪ Compact and lightweight, stored in a few flight cases ▪▪ AC Testing (50 Hz) of switch gears and busbars up to 190 kVrms localisation and dissipation factor estimation ▪▪ Available for Medium and High Voltage Testing. BAUR Prüf- und Messtechnik GmbH · Raiffeisenstraße 8 · A-6832 Sulz · T +43 55 22 49 41-0 · F +43 55 22 49 41-3 · [email protected] · www.baur.at BAUR Prüf- und Messtechnik GmbH · Raiffeisenstraße 8 · A-6832 Sulz · T +43 55 22 49 41-0 · F +43 55 22 49 41-3 · [email protected] · www.baur.at Subject to change without notice. 04/2014 Art. no. 821-068
© Copyright 2025 ExpyDoc